16A-020 (9) 507 FAIRWAY VLG BP-2017-0884
GIS#: COMMONWEALTH OF MASSACHUSETTS
MwBlock: 16A-020 CITY OF NORTHAMPTON
Lot: -000 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
Category: woodstove BUILDING PERMIT
Permit# BP-2017-0884
Pro iect# JS-2017-001499
Est.Cost $6200.00
Fee: $40.00 PERMISSIONIS HEREBY GRANTED TO:
Const.Class: Contractor: License:
Use Grouu: THE FIRE PLACE 180477
Lot Size(so. ft.): Owner: GRECO DENNIS S
Zoni= URA(102)/WP(17)/WSP(15)/ Applicant: THE FIRE PLACE
AT. 507 FAIRWAY VLG
ApplicantAddress: Phone: Insurance:
P O BOX 606 (413)397-3463 O WC
WHATELYMA01093 ISSUED ON:1/23/20170:00:00
TO PERFORM THE FOLLOWING WORK:HARMON ABSOLUTE PELLET - INSTALLING
PELLET VENT THROUGH THE ROOF
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter:
Footings:
Rough: Rough: House# Foundation:
Driveway Final:
Final: Final:
Rough Frame:
Gas: Fire Department Fireplace/Chimney:
Rough: Oil: Insulation:
Final: Smoke: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Certificate of Occupancy Signature:
FeeTYpe: Date Paid: Amount:
Building 1/23/2017 0:00:00 $40.00
212 Main Street,Phone(413)587-1240, Fax: (413)587-1272
Louis Hasbrouck—Building Commissioner
City of Northampton
x
Massachusetts
{`p DEPARTMENT OF BUILDING INSPECTIONS
S
l�a6R Sy^j4' 212 Mein Street • MYnlCipal Building
Morthaini MA 01060
r>
60'/7 - e/
SINGLE OR TWO FAMILY SOLID FUEL APPLIANCE PERMIT APPLICATION
� - FOR WOOD, COAL, PELLET,CORN,STRAW O�yy�IlIMII)LAR STOVES./OR FIREPLACES
Check# /I _ $Ll(
Please fill in all appropriate information dd
1 rco`A. t aM ht /
A✓ ess 106 0/043 Telephone- ¢13 373'14
Owner a=Prone^y _ _ -_Dennis S. Greco
A:'- ,,Es, 507 Fairway Village, Leeds, MA 01053 Talephone 413-320-1968
S' + is a Np{,li srn Owner Contractor
.LL ;, UL/���. Ile f*+/`11 1 rd
stin,ate_icc„t
;2 00 00 rpO
If applicant is not the homeowner. ��++
C` ¢nrt r�,a a �eo?lIj �A)PZ-C Email '. rlo,- 1 u 611A.rd SA'n '1!1r 115e Cera
s.tr s L rmoi,e Number �40� _ Expiration Date
n rrr:r., r , .:ockauo, Registration Number /J-6 77 Expiration Date
All Applicants must complete a Workers Compensation Insurance Affidavit before we can issue a permit
C, I f i ,!i or h ea r: :;ertifc that the information contained herein is true and accurate i, the Lest cf my
unoviedge.
OAI E /' 79-7;7 APPLICANTS SIGNATURE —z� --
DhTE 12/21/2016 HOMEOWNERS SIGNATURE
APPROVED 9
DA' "` BUILDING OFFICIA
-" The Commonwealth of Massaclut.selts
Department of lnduslrial Accidents
- / Congress Street,Suite 100
Boston, MA 02114-2017
www.mussgot✓dia
C\I rk"''(umpensation Insurance Affidavit: Builders/(ontractors/Electricia os/Plumbers.
10 BE FIELD 111111 TLE.PERAIITII]G U 110R1'11.
\pplir:ud Infiannal inn Plevse Print Le_ibN
\anx uo.rl...I n_aai.ntrom holh, dar,ll:THE FIRE PLACE
,%ddre" 106 STATE RD
(
it, Stale /ip WHATELY, MA 01093 Phone #:413-397-3463
fro urian rnnl.n ee l u.rL nip npp""prl.ne nn.: _
` Type of prnjeet (required):
10 .......,nm.nJ1 nndm'p-tara') 7N,,,
❑I ,d..l - a mplq .asmp ter—ar g- ❑ Relnodeho-
I• . dl
❑ - duan,.. 9. ❑Deonnl t1 n
ny mlh'
I,, ❑I d II k prp.m I,.11 10❑ B Id Ihlilion
%-k— ,,a...., _ raore or are sole II.❑Iifeet, a apmr,of odAitlons
12.❑Plumbinp q.;dl3 or additions
Il.o. h'.111 11t I'ted h m.hed 11hee.
II Iln.vnrkn ' onp_-nsum„cc 13.❑R lr pain
❑\t C r_n _ d - - It Pt per MGI.c. i❑Other _.
_ re . . A ,A.n crarp_ aaran.e,tyu..ofI
LJ.'shoe"aaee kr.. ..aryicf pll..llhmvum,
_... f.n:.,. u.J. n,..areJar all .,k and her I- n.d—,rs ulna ; , Ir.I., , .uch
(, ... I .I . ..r.,11,1djoalojisheei anora the Mme l,n ,ol ,oaca ardoonolacflo, .... ,.,Iroe
I e..l--„ r.ne.r.l o,n cmplr — lI,, our,armide nreir w.rkc, aaan lmh.z a her.
l u
it enprb,re-ohal i,pro,Wine o"A",'campensntion insnrance jor ml eroplo,ees. Be/mr A the I th i rmdjoh site
ml...mlodnn.
"'ooar a [nntpom \omc:(VIA RETAIL MERCHANTS WC GROUP
014005033601116 _ Evptrntlon Date: 1-1-18
lot site .vddre SQA /-Cirafay V/ la-�-c Chv/Smte/Lip:_ �Tzs /xA 0105,3
Waeh a co py of the wurherC compensation olicV declaration page showing __.,__
1. I P P S ( the policy number and es pi ra[imp Atte).
I-:d are to.acu«-eoccr�c o.rnluiied under MGL e. 152_§25A is a criminal violation Imnishable be a I!,,, up to S l iO0.00
.Ind or ono-�.ar ilnpri>onmenl.as ,.cll as civil penalties in the form of a S I OP WORK ORDER and a Ilne A up to S'- 0.00 it
das :.-mast the, olator. .A cop, of ,hisxlalement may be forwarded to the OITce oflmestisotiolu of the DI A It”insu'ance
clnec s ri0caGen_
/
to,herehi "fill/i'+(nr/er if,,,Indus and ped lQties�nf perjure•that the information proriderr nbnre is true mid rorrecl.
ti'itturc: S' ''l _ �— 6Date- z
I'hunc=.413-397-3463
O/liriul ase e n i. D„mol o mr-in this area,m he campleted bl'cin or anvo r jfic'inl.
in IIr l'Imn: Permit/License
Iew7ne lothm5t) Ici vele unel:
J. 13nard rel llcalth 2. hoihtuo, Depmtmeat 3.CityrFown Clerk 4. Electrical Inspector S. Plumhine lnspeetor
6. Other
( ontnct Person: Phone#c
B. Non-Combustible Materials Specification
Material which will not Ignite and burn. Such materials are ,
those consisting entirely of steel, iron, brick, tile, concrete, _ 2"f57mm)
slate,glass or plasters,or any combination thereof.
Materials that are reported as passing ASTM E 135, `-
Standard Test Method for Behavior of Materials in
a Vertical Tube Furnace at 750" C and UL763 shall be
considered non-combustible materials. ---- 5"(152mm)
C. Combustible Materials Specification
Materials made of or surfaced with wood, compressed
paper,plant fibers, plastics,or other material that can ignite ..
and burn, whether flame proofed or not, or plastered or un-
plastered shall be considered combustible materials.
D. Clearances to Combustibles s^la5omm)
When selecting a location for the appliance il is important to
consider the required clearances to walls(see Figure 3.2).
WARNING
s.zs
RISK OF FIRE OR BURNS! Provide adequate (159mm)
clearance around air openings and for service
access. Due to high temperatures, the appliance should / t,
be located out of traffic and away from furniture and
draperies.
NOTICE.'Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.Actualinstaflation may vary dueu m
i
to individual design preference. 3 N
Place the stove away from combustible walls at least as far 3
as shown in Figure 3.2.
Note thatthe clearances shown are minimum for safety but do
not leave much room for access when cleaning or servicing.
Please take this into account when placing the stove.
When installing the unit into an alcove it is important to NOTE: Top of unit must be a minimum of 12'(305mm)to
consider the required clearances listed below. Iceiling
Figure 3.2
CAUTION
I THIS APPLIANCE MUST BE VENTED 70 THE OUTSIDE.
z
NOTICE: Clearances may only be reduced by means
7 approved by the regulatory authority having jurisdiction.
_ Due to high temperatures, the stove should be placed away
from traffic,furniture and draperies.
36"Wide Children and adults should be alerted 10 the hazards of high
surface temperatures and should stay away to avoid burns
to skin andtor clothing.
Young children should be carefully supervised when they are
in the same room as the stove.
FiggM1t=82".Witl[h=38,aepm•2b'
Clothing and other Flammable materials should not be placed
on or near this unit.
8 Heonan® -Aboi�te43 fta a vibwn Marvel R5 • 2015 00115 3 90-66778;
E. Floor Protection Comer to edge dimension for corner installation floor protection.
Place the stove on a noncombustible floor or floor protector -- - —
that extends a minimum of 6 inches (152mm) to the front
of the load door opening.6 inches(152mm)to the sides of 4'
the door opaning, and 1 inches to the rear. Floor protection
must also extend 2 inches(51mi beyond each side of any
horizontal flue pipe. The minimum floor protector material
is 20 gauge Sheet metal. Other floor protector materials are
ceramic tile,stone, brick.etc. Figure 3.3
NOTE for Canadian installation only: Per ULC-S627-00,
if installed on a combustible floor, the need to provide a
noncombustible floor protector covering the area beneath
the space heater and extending at least 17.72"(450mm)on
the firing side and at least 7.87"(200mm)on the other aides.
In Canada, you may follow the smaller U.S. floor
protection requirements ONLY if the user agrees to
completely shut-down the appliance,and allow it to cool \—
to where all fire is extinguished and the combustion
blower and Its indicator light shuts off, prior to opening _
the firebox door or ash door.
Minimum Size floor protection (USA)is 25-7/8"wide By 28' Alternate floor protector dimension may be used as long
deep(658mm X 711 ri as they satisfy, the measurement requirements shown
"Floor protection dimensions for the front and sides are below.
measured from fie appliance door opening in The United Minimum size fleor protection for a comer installation
States.In Canada,the side dimension is measured from the hearth pad is 36"x 36"(USA ONLY).Note:Floorprotector
widest part of the appliance. WILL NOT touch the wall.
----...J--- -- ---- L F. Mobile Home Installation
L When Installing this unit in a mobile home, several
- - requirements must be followed:
1. The unit must be bolted to the floor in places. This can
be done using 1/4"lag screws through the skid bolt down
holes located at the base of the unit.Note: Lag bolt must
be installed from the bottom up.
2. The unit must be connected to an outside combustion
air inlet. Proper supports and spark arresters must be
considered when installing venting, See "Termination
Location and Vent information"Section D.
3. Floor protection and clearances must be followed as
shown.
-- -� 4. Unit must be grounded to the metal frame of the mobile
hi
J CANADA
USA
K
Figure 3.3
Floor Protection U3, caramits
Reuiram4hts a o
J Sides 6" 200mm
K Front 6" 450mm
L Rear 1" 25mm
Note:Measurement"L"is even with the rear of the hopper in the oust 114-lag bells here
US ONLY
Note: Measurement "K' is measured from the glass in the US
ONLY
9 Hamenh , Absdute43instaillhon Manual R5 2015- • he115 390007Tei