18C-181 (3) 74 HATFIELD ST SM-2017-0024
COMMONWEALTH OF MASSACHUSETTS
CITY OF NORTHAMPTON
CIS k. 12180
Map: 18C
tck 181 g Ij!lSHEETMETAL PERMIT
Permit: ''SHEETMETAL
Category: SHEETMETAL
Pe m t# SM-2017-0024 PERMISSION IS HEREBY GRANTED TO:
Project# ITS-2017-000623
Est.Cost $10,00000 Contractor: License: Expires:
Fee Charged: ROCK VALLEY HVAC Sheetmetal-2626
Charged:F5.00 04/28/2016
Balance Due $.o0 Owner: L P AUDETTE BUILDERS INC
#of Fixtures: Applicant: ROCK VALLEY HVAC
�pigSafe# AT:I74 HATFIELD ST
�UseGroup
ConstClass
ISSUED ON: AMENDED ON: 02-Nov-2016 EXPIRES ON:
TO PERFORM THE FOLLOWING WORK:
UNIT B-COMPLETE HVAC SYSTEM,ALL DUCTS SEALED&INSULATED TO ENERY STAT STANDARDS
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Signature:
Fee Type: Receipt No: Date Paid: Check No: Amount:
Sheetmetal REC-2017-001784 01-Nov-16 1245 $2500
212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,Email:lhasbrouck®northamptonma.gov
GeoTMSi 2016 Des Lauriers Municipal Solutions,Inc.
File#SM-2017-0024
APPLICANT/CONTACT PERSON ROCK VALLEY HVAC
ADDRESS/PHONE 7 APPLEWOOD LN (413)535-7804
PROPERTY LOCATION 74 HATFIELD ST
MAP 18C PARCEL 181 ZONE
THIS SECTION FOR OFFICIAL USE ONLY:
PERMIT APPLICATION CHECKLIST
ENCLOSED 5 REQUIRED DATE
ZONING FORM FILLED OUT
Fee Paid ��j ����
Building Permit Filled out
Fee Paid
Typeof Construction: UNIT B-COMPLETE HVAC SYSTEM,ALL DUCTS SEALED&INSULATED TO
ENERY STAT STANDARDS
New Construction
Non Structural interior renovations
Addition to Existing
Accessory Structure
Building Plans Included:
Owner/Statement or License 2626
3 sets of Plans/Plot Plan
THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON
INFORjIATION PRESENTED:
frIjiproved Additional permits required(see below)
PLANNING BOARD PERMIT REQUIRED UNDER: §
Intermediate Project: Site Plan AND/OR Special Permit with Site Plan
Major Project: Site Plan AND/OR Special Permit with Site Plan
ZONING BOARD PERMIT REQUIRED UNDER: §
Finding Special Permit Variance*
Received&Recorded at Registry of Deeds Proof Enclosed
Other Permits Required:
Curb Cut from DPW Water Availability Sewer Availability
Septic Approval Board of Health Well Water Potability Board of Health
Permit from Conservation Commission Permit from CB Architecture Committee
P 't from Street Co si Permit DPW Storm Water Management
Signature of Building cia
-1/4(Date
Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning
requirements and obtain all required permits from Board of Health,Conservation Commission,Department
of public works and other applicable permit granting authorities.
* Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact the Office of
Planning&Development for more information.
Commonwealth of Massachusetts
1 I — I
Sheet Metal Permit
Date: 10/24/2016 Permit#SftJ-J 7- 24-,/
Estimated Job Cost: $ 10 000 Permit Fee: $
Plans Submitted: YES J NO Plans Reviewed: YES NO
Business License # Applicant License # SM2626
Business Information: Property Owner/Job Location Information:
Name: Rock Valley HVAC Name: L.P.Audette Builders Inc.
Street: P.O.Box 1162 Street: 74 Hatfield Street Unit B
City/Town: Easthampton, Ma City/Town:diskaharntaton _.
Telephone: 413-535-7804 Telephone: 413-539-7381
Photo I.D. required/Copy of Photo I.D.attached: YES NO
Stall Initial
J-11 M-1-unrestricted license
J-2/M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq.ft. /2-stories or less
Residential: 1-2 family Multi-family Condo/ Townhouses Vt Other
Commercial: Office Retail Industrial Educational
Institutional Other
Square Footage: wider 10,000 sq. ft. 1r over 10,000 sq. ft. Number of Stories: 2
Sheet metal work to be completed: New Work: Renovation:
HVAC NIT Metal Watershed Roofing Kitchen Exhaust System
Metal Chimney/ Vents Air Balancing
Provide detailed description of work to be done:
Complete HVAC system, all ducts sealed and insulated to energy star standards
INSURANCE COVERAGE: J
I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L.Ch.112 Yesllp No 0
if you have checked Yes,indicatetthe type of coverage by checking the appropriate box below:
A liability insurance policy y� Other type of indemnity ❑ Bond ❑
OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the
Massachusetts General Laws,and that my signature on this permit application waives this requirement
Check One Only
AD
Owner Agent ❑
Signature of Owner or Owner's Agent
By checking this box❑,I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and
accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be
in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws.
Duct inspection required prior to insulation installation:YES NO
Progress Inspections
Date Comments
Final Inspection
Date Comments
Type of License:
By Master
Title ❑ Master-Restricted —�'
City/Town
❑Joumeyperson Signature of Licensee
Permit#
❑Joumeyperson-Restricted License Number: SM2626
Fee$
Check at www.mass.gov/dpl
Inspector Signature of Permit Approval
N
ks el
AIF—
Basement
rt
"D'-W
I " "1s/ 7A,,s,
Room11
/
�`v�� /fr !'bi
\v
c
wni 7 id (.
siasost
Job#: Rock Valley HVAC
Scale'
1 : 50
Performed for:
LarrySadeR PO Box 1162 Right-Suikk®Universa12017
74 Haleld StreetU6613 Easthampton, Ma 01027 17.010 RSU24598
Northampton,Ma 01060 2016-04-31 12 52 26
Phone 413-539-7381 Rhone, 41353571304 _eat load968 Hatfield Sreetup
audta1950@gmadtmm WWW rockvalleyhvac.com Rochvalleyhvac@yahoo.00m
N
1'9‘
Level 1
Kitchen Wash/Bath
•
J
Living Room
. Entry
Job ft: Rock HVAC Scala. 1 : 50
Performed for: Page
Larry Auclelb P0. BIM 1162 Rght-Silt®Universa12017
74 Hated n,Ma 0 nRB 170.10 RSU24598
Nornampbn,Ma 01060
Easthampton: 413- Ma 01027 2016-0¢-31 125226
Phone 413-539-7381 Phone 41&535-7804 _eatdatl368 Hated S reetrup
audla1950@gmail o]m akmv rockvalleyhvac.can ROCkvalleyhvaa(gyahm.Cpm
N
Level 2
Bath
Bed
WIC Entry/ Stairs
Master M Bath
Wit
j
Job#' Rock Valley HVAC Scala. 1 : "0
Performed for: Page 1
LarryPude@ PO Bat 1162 Ryht-Sine Univers&201➢
68 Hatheki Street Easthampton, Ma 0'1027 17010 RSU24598
ortha 13-53a 01060 2016-Oct-24162956
Phone:413-539-7381 ac ca 4R13 kvailL4�0 eatbadd68 Halfieb Steetrup
audb1950(@gmadcom vmrw rockvelleyhvac.can Rockvallehvac(tgyahoo.arn
wrightsoft Project Summary Date: Jul 25,2016
Entire House By:
Rock Valley HVAC
P.O.Box 1162 Easthampton,Ma 01027 Phone-013-535-7804 Email:Rcckvalleyhvacamahoocon,Web.www.rockvalleyhvac.com
Project Information
For: Larry Audette
74 Hatfield Street Unit B. Northampton, Ma 01060
Phone: 413-539-7381
Email: audIa1950@gmail.com
Notes. 4tt c -t�.✓U-17can sfar.ct& �
r �' 54 v.) c,Nc.ti P5A1q 9GYC• VA-
Cot
ne
r l- A/I&Lcc.cct✓1 5f4:0d-ie�qVrx(Zoo 3L�55 He k i. 5-7-0,-,4/c - 4/id1-cscn `>fc4J7a.cf q/47A7/vfel_7coo R /5/SEE,C
Desi. n Information
Weather: Springfield, Westover AFB(Worchester Dd), MA, US
Winter Design Conditions Summer Design Conditions
Outside db 0 °F Outside db 87 °F
Inside db 70 °F Inside db 72 °F
Design TD 70 °F Design TD 15 °F
Daily range M
Relative humidity 50
Moisture difference 31 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 32576 Btuh Structure 12005 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 32576 Btuh Use manufacturer's data n
Rate/swing multiplier 0.92
Infiltration Equipment sensible load 11045 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 1 (Average) Structure 758 Btuh
Ducts 0 Btuh
Healing Cooling Central vent(0 cfm) 0 Btuh
Area(ft2) 1224 1224 Equipment latent load 758 Btuh
Volume(ft') 10491 10491
Air changes/hour 0.50 0.21 Equipment total load 11802 Btuh
Equiv.AVF (cfm) 88 37 Req. total capacity at 0.70 SHR 1.3 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make
Trade Trade
Model Cond
AHRI ref Coil
AHRI ref
Efficiency 80AFUE Efficiency 0 SEER
Heating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 °F Total cooling 0 Btuh
Actual air flow 647 cfm Actual air flow 647 cfm
Air flow factor 0.020 cfm/Btuh Air flow factor 0.054 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.94
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
_
20100H-24 16:5200
wrightsoft' Right-Sua m Universal 2017 17M 10 RSU24598
Page 1
, CCN s\Wes\Desktap1Heat ioadsls8 Hatfield Streel.rup Calc=MAI Front Door faces: lu