Loading...
18C-180 (2) 70 HATFIELD ST SM-2017-0026 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON GIS#: 12178 ° °. Map: 18C Block Lot:: O 80 SHEETMETAL PERMIT Permit: SHEETMETAL Category: SHEETMETAL Permit# SM-2077-0026 PERMISSION IS HEREBY GRANTED TO: Per m Project# IJS-2017-000622 --_ _- Contractor: cense: IEst.Cost: $10,00o0.0. CttLi 0 Expires: Fee Charged:$25.00 ROCK VALLEY HVAC Sheetmetal-2626 04/28/2016 Balance Due:.,$.00 Owner: L P AUDETTE BUILDERS INC #of Fixtures: Applicant: ROCK VALLEY HVAC DigSafe# _ FAT: 70 HATFIELD ST UseGroup ConstClass - _--- ISSUED ON: AMENDED ON: 02-Nov-2016 EXPIRES ON: TO PERFORM THE FOLLOWING WORK: UNIT A-COMPLETE HVAC SYSTEM,ALL DUCTS SEALED&INSULATED TO ENERGY STAR STANDARDS THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fee Type: Receipt No: Date Paid: Check No: Amount: Sheetmetal REC-2017-001786 01-Nov-16 1245 $25.00 212 Main Sheet,Phone:(413)587-1240,Fax:(413)587-1272,Email:Ihasbrouck@northamptooma.gov GeoTMS®2016 Des Lauriers Municipal Solutions,Inc. File#SM-2017-0026 APPLICANT/CONTACT PERSON ROCK VALLEY HVAC ADDRESS/PHONE 7 APPLEWOOD LN (413)535-7804 PROPERTY LOCATION 70 HATFIELD ST MAP 18C PARCEL 180 ZONE THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paidig -07/6 26 C" .6 Building,Permit Filled out L1 `�/ Fee Paid Tvoeof Construction: UNIT A-COMPLETE HVAC SYSTE ALL DUCTS SEALED&INSULATED TO ENERGY STAR STANDARDS New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 2626 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INF9Rft7-ATION PRESENTED: /Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER: § Intermediate Project: Site Plan AND/OR Special Permit with Site Plan Major Project: Site Plan AND/OR Special Permit with Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received& Recorded at Registry of Deeds Proof Enclosed _Other Permits Required: Curb Cut from DPW _ Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee it • • Elm Street Commission _ Permit DPW Storm Water Management —tit—idalliaealliiiiiiiiiiiiiii IL More of Building 0 t ial Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact the Office of Planning& Development for more information. F-11:1-;, ' r . 1 Commonwealth of Massachusetts fei — Sheet Metal Permit �/ )'3afe 10/24/2046 Permit#�YI'1'7 u6 Estimated Job Cost: $ 10,000 Permit Fee: $ (/6 Plans Submitted: YES J NO Plans Reviewed: YES NO Business License# Applicant License# SK/12626 Business Information: Property Owner/Job Location Information: Name: Rock Valley HVAC Name: L.P.Audette Builders Inc. Street: P.O.Box 1162 Street: 70 Hatfield Street Unit A City/Town: Easthampton, Ma City/Town: Northampton Telephone: 413-535-7804 Telephone: 413-539-7381 Photo I.D. required/ Copy of Photo I.D. attached: YES NO_ Staff Initial J-1 /M-1-unrestricted license J-2 /M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less Residential: 1-2 family Multi-family Condo/ Townhouses J Other Commercial: Office Retail Industrial Educational Institutional Other Square Footage: under 10,000 sq. ft. J over 10,000 sq. ft. Number of Stories: 2 Sheet metal work to be completed: New Work: Renovation: HVAC V Metal Watershed Roofing Kitchen Exhaust System Metal Chimney/Vents Air Balancing Provide detailed description of work to be done: Complete HVAC system, all ducts sealed and insulated to energy star standards INSURANCE COVERAGE: J I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L.Ch.112 Yes'p No 0 If you have checked Yes,indicate the type of coverage by checking the appropriate box below: A liability insurance policy Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement Check One Only Owner Irl Agent ❑ Signature of Owner or Owner's Agent By checking this boxl],I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Duct inspection required prior to insulation installation:YES_NO Progress Inspections Date Comments Final Inspection Date Comments Type of License: By Master Ttle ❑ Master-Restricted City/Town ❑Joumeyperson Signature of Licensee Permit# ❑Journeyperson-Restricted License Number: SM2626 Fee S ❑ Check at www.mass.govldpl Inspector Signature of Permit Approval N I' tvei4r2 1 fr11} �rys 7_0(g;1 c%S ;&.',.,s/ "�'�y2/ L'infa''gi !s! Room8 A- /a7 71 rc • a r s/"S 7ajs! 4 "2- /an= >_i P"P ens- 1i,+/ c^5 Jis/ Performed for. Rock Valley HVAC Scale= 1 45 Page 1 LarryAudete PO-Box1162 Rig ht-Suit®UnheraaI2017 74 Hatfield StreetUnhB Eashampbn,Ma 01027 17.0.10 RSU24598 Northampbn,Ma 01060 Phone 413-535-7804 2016-0d-311225-07 Phone 413-539-7381 www.rodaaalle#ecmm Rodoelleyhvaogyahoo.mm _eat badd68 Hatfield Streetrup audb1950@gmaiI m N Lev4„,..„„....,..,..„,,,,, el 1 7 �� „,.::,,.....,,,,,,„s, 4 x Wash/Bath Kitchen — n u Stairs N - x Living Room Entry ------r rj ii I I Job #: Rock Valley HVAC Scale: I 45 Performed for Paget LarryAudetle PO.Box1162 Right-Sum Unhersa12017 74 Hatfield StreetUniB Ea5hampbn,Ma 01027 17.0.10 RSU24598 Northampton,Ma 01060 Phone 413-535-7804 2016-063112:1748 Phone 413-539-7381 www.rodcalleyhacom Rodalleyhtec@tehoocom _eatloads58 Hatfield Streetrup audla1950@gmail.com N Level 2 Bath Bed Q HaIV Stairs WIC Bed 2 WIC 2 r A. .lob x Rock Valley HVAC Scale 1 : 45 Performed for Page LarryAudetb PO.Box1162 Rght-SLhe®Unnersa12017 74 Hatfield StreetUnhB Easihampbn,Ma 01027 17.0.10 RSU24598 Northampton,Ma 01060 Fhone:413-535-7804 2016-Oct-31 12:17'45 Phone:413-539-7381 www rodc lleyhvacmm Rodaalleyhnroaphoowm ..eatbads58 Hateb Streetrup audIa1950@gmadmm wrightsoft° Project Summary Date: Ju125,2016 Entire House Dy: Rock Valley HVAC P.O.Boa 1162,Easthampton,Ma 01027 Phone'.413-535-7804 Email:Rcckvalleyevac yahoo.com Web:www.mekvalleynvac.cwn Project Information For: Larry Audette 70 Hatfield Street Unit A, Northampton, Ma 01060 Phone: 413-539-7381 Email: audla19n50@gmail.com �/ V/5 Notes: FL rn c°cc.-Antxr1'can S4nice d $9 Y a$erJ�K 3 P SH A q� it; le, /- %/JLcr ; can Sfavld7eic/ NTXC&0031,55 NIA /. c-y. 44-<lacer-Ree el 5fe,rind/ 017490(84/oGe/9 iY seer Desi e n Information Weather: Springfield, Westover AFB(Worchester Dd), MA, US Winter Design Conditions Summer Design Conditions Outside db 0 °F Outside db 87 °F Inside db 70 °F Inside db 72 °F Design TD 70 T Design TD 15 °F Daily range M Relative humidity 50 Moisture difference 31 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 32576 Btuh Structure 12005 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 32576 Btuh Use manufacturer's data n Rate/swing multiplier 0.92 Infiltration Equipment sensible load 11045 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 1 (Average) Structure 758 Btuh Ducts 0 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 1224 1224 Equipment latent load 758 Btuh Volume(fa) 10491 10491 Air changes/hour 0.50 0.21 Equipment total load 11802 Btuh Equiv.AVF (cfm) 88 37 Req. total capacity at 0.70 SHR 1.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80 AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 647 cfm Actual air flow 647 cfm Air flow factor 0.020 cfm/Btuh Air flow factor 0.054 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.94 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ 2016-Oct-24 1s 50:1J wright'Soft Right-Suttee Universal 201717-0.10 RSU2459e Page 1 ACCN ._s\Wes\Desktop\Heal loads168 HaOIel Street.mp Cale=MJB Front Door raises. N