8 Septic Inspection Form 1996 UON SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION Address of property: 8 SHEPHERD'S HOLLOW, NORTHAMPTON Owner: GREGORY & SYLVIA ZAKRZEWSKI Date of Inspection: 1-25-96 Inspector: James A. Gracia, PE 99 Glendale Street Easthampton, MA 01027 413-527-5290 Certification Statement I certify that I have personally inspected the sewage disposal system at this address and that the information reported below is true, accurate, and complete as of the time of inspection. The inspection was performed based on my training and experience in the proper function and maintenance of on-site sewage disposal systems. The system: XXX Passes Conditionally Passes Needs Further Evaluation by the Local Approving Authority(Bd. Of Health) Fails Inspectors Signature 4 J de The system inspecto shall submit a copy of this inspection report to the Approving Authority within thirty(30) days of completing this inspection. If the system is a shared system or has a design flow of 10,000 gallons per day or greater, the inspector and system owner shall submit the report to the appropriate Regional Office of the Department of Environmental Protection. The original should be sent to the system owner and copies sent to the buyer and approving authority. Date: S�9 INSPECTION SUMMARY: A. System Passes: XX I have not found any information which indicates that the system violates any of the failure criteria as defined in 310 CMR 15.303. Any failure criteria not evaluated are indicated below. 2 B. System Conditionally Passes: One or more system components need to be replaced or repaired. The system, upon completion of the replacement or repair, passes inspection. (Indicate yes, no, not determined (Y, N, or ND). Describe basis of determination in all instances. If"not determined", explain why not.) Septic tank is metal, cracked, structurally unsound, shows substantial infiltration or exfiltration, or tank failure is imminent. The system will pass inspection if the existing septic tank is replaced with a conforming septic tank as approved by the Board of Health. Sewage backup or breakout or high static water level observed in the distribution box is due to broken or obstructed pipe(s) or due to a broken, settled, or uneven distribution box. The system will pass inspection if(with the approval of the Board of Health): broken pipe(s) are replaced obstruction is removed distribution box is leveled or replaced The system required pumping more than four times a year due to broken or obstructed pipe(s). The system will pass inspection if(with approval of the Board of Health): broken pipe(s) are replaced obstruction is removed C. Further Evaluation is Required by the Board of Health: Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect the public health, safety, and the environment. 1. System will pass unless Board of Health determines that the system is not functioning in a manner which will protect the public health and safety and the environment: Cesspool or privy is within 50' of a surface water Cesspool or privy is within 50' of a bordering vegetated wetland or a salt marsh 2. System will fail unless the Board of Health (and public water supplier, if appropriate) determines that the system is functioning in a manner that protects the public health and safety and environment: The system has a septic tank and soil absorption system and is within 100' of a surface water supply or tributary to a surface water supply. 8 Shepard's Hollow, Northampton 3 The system has a septic tank and soil absorption system and is within a Zone I of a public water supply well. The system has a septic tank and soil absorption system and is within 50' of a private water supply well. The system has a septic tank and soil absorption system and is less than 100'but more than 50' from a private water supply well, unless a well water analysis for coliform bacteria and volatile organic compounds indicates that the well is free from pollution from that facility and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm. D. System Fails: I have determined that the system violates one or more of the following failure criteria as defined in 310 CMR 15.303. The basis for this determination is identified below. The Board of health should be contacted to determine what will be necessary to correct the failure. Backup of sewage into facility or system component due to an overloaded or clogged SAS or cesspool. Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool. Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool. Liquid depth in cesspool is less than 6" below the invert or available volume is less than Ya day flow. Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Number of times pumped Any portion of the soil absorption system (SAS), cesspool or privy is below the high groundwater elevation. Any portion of a cesspool or privy is within 100' of a surface water supply or tributary to a surface water supply. Any portion of a cesspool or privy is within a Zone I of a public water supply well. Any portion of a cesspool or privy is within 50' of a private water supply well. Any portion of a cesspool or privy is less than 100'but more than 50' from a private water supply well with no acceptable water quality analysis. If the well has been analyzed to be acceptable, attach copy of well water analysis for coliform bacteria, volatile organic compounds, ammonia nitrogen and nitrate nitrogen. E. Large System Fails: The following criteria apply to large systems in addition to the criteria above: The design flow of system is 10,000 GPD or greater and the system is a significant threat to the public health and safety and the environment because one or more of the following conditions exist: 8 Shepard's Hollow,Northampton 4 The system is within 400' of a surface drinking water supply. The system is within 200' of a tributary to a surface drinking water supply. The system is located in a nitrogen sensitive area(Interim Wellhead Protection Area or a mapped Zone II of a public water supply well). The owner or operator of any such system shall bring the system and facility into full compliance with the groundwater treatment program requirements of 314 CMR 5.00 and 6.00. Please consult the local regional office of the Department of Environmental Protection for further information. PART B: CHECKLIST X Pumping information was requested of the owner, occupant, and/or BOIL X None of the system components have been pumped for at least two weeks prior to inspection and the system has been receiving normal flow rates during that period. Large volumes of water have not been introduced into the system recently or as part of this inspection. X As-built plans have been obtained and examined. Note if not available with N/A. X The facility or dwelling was inspected for signs of sewage back-up. X The site was inspected for signs of breakout. X All system components, excluding the SAS, have been located on the site. X The septic tank manholes were uncovered, opened, and the interior of the septic tank was inspected for condition of baffles or tees, material of construction, dimensions, depth of liquid, depth of sludge, depth of scum. X The size and location of the SAS on the site has been determined based on existing information or approximated by non-intrusive methods. X The facility owner(and occupants if different from owner)were provided with information on the proper maintenance of Sub-surface Sewage Disposal Systems. 8 Shepard's Hollow, Northampton PART C: SYSTEM INFORMATION FLOW CONDITIONS Residential: Design Flow: 495 Gallons per Day Number of bedrooms: 3 Number of current residents: 4 Garbage disposal: Yes Laundry connected to system: Yes Seasonal use: No Water meter readings, if available: N/A (Private Well) If vacant, last date of occupancy: N/A Commercial/Industrial: Type of Establishment: Design Flow: Gallons per Day Grease Trap present: Industrial Waste Holding Tank present: Non-sanitary waste discharged to the Title 5 system: Water meter readings, if available: Last date of occupancy: Other: (Describe) Last date of occupancy: GENERAL INFORMATION Pumping records and source of information: System last pumped in August 1995, per owner and pumper. System pumped as part of inspection: YES If yes, volume pumped: 1500 Gallons 5 8 Shepard's follow, Northampton 6 Type of system X Septic tank/distribution box/SAS Single cesspool Overflow cesspool Privy Shared system(If Yes, attach previous inspection reports, if any) Other Approx. age of all components/Date installed/Source of info: System installed new in 1987 per owner and Board of Health records. Sewage odors detected when arriving at the site: No SEPTIC TANK: OK Depth below grade: 15" Material of construction: CONCRETE Volume: 1500 GALLONS Dimensions: 5' W x 10' L x 4' D 2" sludge depth 33" distance from top of sludge to bottom of outlet tee or baffle 0" scum thickness(minimal scum due to recent pumping) 6" distance from top of scum to top of outlet tee or baffle 15" distance from bottom of scum to bottom of outlet tee or baffle Comments: Tank in good condition. No signs of deterioration. Center access cover has been extended to grade. 8 Shepard's Hollow, Northampton 7 GREASE TRAP: N/A Depth below grade: Material of construction: Volume: Dimensions: Comments: scum thickness distance from top of scum to top of outlet tee or baffle distance from bottom of scum to bottom of outlet tee or baffle TIGHT TANK or HOLDING TANK: N/A Depth below grade: Material of construction: Volume: Dimensions: Design Flow: Alarm Level: Comments: DISTRIBUTION BOX: N/A Depth of liquid level above outlet invert: Comments: PUMP CHAMBER: N/A Pump(s)in working order: Comments: 8 Shepard's Hollow, Northampton 8 SOIL ABSORPTION SYSTEM (SAS): OK If not located on site, explain: Type&Dimensions: Leaching Pit, Chamber, or Gallery: 4' W x 8' L x 36" D plus stone around and under pit Leaching trenches Leach field Overflow cesspool Comments: Leach Pit in good condition. CESSPOOL: N/A Number& configuration Depth: top of liquid to inlet invert Depth of solids layer Depth of scum layer Dimensions of cesspool Materials of construction Indication of groundwater inflow(during pumping) Comments: PRIVY: N/A Materials of construction Dimensions Depth of solids layer Comments: 8 Shepard's Hollow, Northampton KES A. GRACIA, PE aendale Street, Easthampton, MA 01027 :OUNDWATER ESTIMATED TO BE BELOW EACH SYSTEM BASED ON TOPOGRAPHY AND ORIGINAL ['ERG TEST REPORT EXISTING WELL 100' K 1500 GALLON SEPTIC TANK I15 BELOW GRADE) EXISTING LEACH PIT 4' W X 8' L X 36 p 2r BELOW GRADE 75't WET AREA >,L 8 SHEPHERD'S HOLLOW NORTHAMPTON, MA SEPTIC INSPECTION PLAN (NOT TO SCALE/ 1 -25 -96