Loading...
32A-177 (9) Orli) 14\66r 7 File R MP-2016-0052 Q APPLICANT/CONTACT PERSON PIONEER CONTRACTORS Vet' 3f. 4 iJ cc ADDRESS/PHONE PO Box 1 145 (413)586-5491 PROPERTY LOCATION 74 BRIDGE ST MAP 32A PARCEL 177 001 ZONE URCp OOV THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DAT ZONING FORM FILLED OUT �77�� 0 Fee Paid Building Permit Filled out Fee Paid Typeof Construction: ZPA-ADD 3 SEASON PORCH New Construction Non Structural interior renovations Addition to Existing Accessory Structure Buntline Plans Included: Owner/Statement or License 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION PRESENTED: _Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER: § Intermediate Project: Site Plan AND/OR Special Permit with Site Plan Major Project: Site Plan AND/OR Special Permit with Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received& Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability _ Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MCL 40A. Contact the Office of Planning& Development for more information. OEG \ 82015 File No. A , t ° e• PERMIT APPLICATION 010.2) lir 1 e or print all information and return this form to the Building Inspector's Office with the$30 filing fee(check or money order)payable to the City ofNorthampton ,(�� .i�.� 1. Name of Applicant: ,) i£ ��I.tdk_4- / -ayteQ,f(.CM 10doiss ___.... Address: ctC^ // '' iII ��tt�f_ •011Y ' Imo} t/hY.t�&Telephone: 'fl3' ha-72&7 2. Owner of Property: (Anil u,P, t�Y1f�I4-1 1L( / tc 1. /-',afi�,.u- 7-333-1- 3. Address: 1 4 �3�. 91' s !!! P"\ O'M'7:. \. Telephone: '7 I3 ' G 3 t - 33-1 , {_,.- 3. Status of Applicant: Owner 1iContract Purchaser Lessee__Other (explain) Coi D:t- 4. Job Location: /�. AS Parcel Id: Zoning Map# - Parcel# District(s): In Elm Street District In Central Business District (TO BE FILLED IN BY THE BUILDING DEPARTMENT) 5. Existing Use of Structure/Property: B ;Twin to • 6. Description of Proposed) Use/Work/Project/Occupation: (Use additional sheets if necessary): r P1. [� 3 J(gen!, Po-AL-- ' . as PcDwS 7. Attached Plans: Sketch Plan V Site Plan Engineered/Surveyed Plans 8. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO DONT KNOW V YES_...._. IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO DONT KNOW YES IF YES: enter Book Page and/or Document It 9.Does the site contain a brook, body of water or wetlands? NO / DONT KNOW YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained , date issued: (Form Continues On Other Side) W\Documents\FORMS\original\Building-Inspccmrtoning-Permit-Applicatiompassive.doc K/48004 10. Do any signs exist on the property? YES NO V IF YES, describe size, type and location: Are there any proposed changes to or additions of signs intended for the property? YES NO '"" IF YES, describe size, type and location:. 11. Will the construction activity disturb (clearing, grading, excavation, or filling)over 1 acre or is it part of a common plan of development that will disturb over 1 acre? YES NO ✓ IF YES, then a Northampton Storm Water Management Permit from the DPW is required. 12. ALL INFORMATION MUST BE COMPLETED,or PERMIT CAN BE DENIED DUE TO LACK OF INFORMATION This column reserved for use by the Building Department EXISTING PROPOSED REQUIRED BY ZONING Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Building Square Footage %Open Space: (lot area minus building&paved parking�_�, #of Parking Spaces #of Loading Docks Fill: (volume ft location) 13. Certification: I hereby certify that the information contained herein is true and accurate to the best of my knowledge. Date: I ziLl/fS Applicant's Signature Al "sil ._ NOTE:Issuance of a zoning permit does not relieve an applicant's burden to comply with all zoning requirements and obtain all required permits from the Board of Health,Conservation Commission, Historic and Architectural Boards,Department of Public Works and other applicable permit granting authorities. W:DocumentstFORMSbriginal\Building-InspecwdZoning-Permit-Appliwtionpassive.doc 8/4/2004 NUM MOTYMiat get 4rlu—L-_ -!_ --MOPERiY LINE 4. +—+—+—+ -I, +—Io RT sms E YARD SET enc _ y- GRASS TO BE I BUILDING is sr TALL 1 PROTECTED&I M q MAINTAINED DURING I CONSTRUCTION AII�' r i I I I MI - EXISTING BUILDING ° II wm 1 1— Iw .. -. .... EXISTING BUILDING- - Oy NO WORN HERE C 1 _- 11.1111111. SPUNNE BEA, ■ mo._._.___—. _'_—__._' —_—_--------_-- . — _ / TROPERi" nc_ I =. L-1.0 r PLANTING & I \ FEATURE LEGEND O nh' I PERENNIAL m I � FLOWER BED F II ,AV, 12FT TALL I I ..1,-,„ FLOWS FLOWERING 1 \ DECIDUOUS TREE I Oy 9 .,1 2 12FT TALL FLOWERING pG Flap°c I . FRUIT TREE 1 FF c0GN I 1 00 vomo + 1i BFT TALL 1 AE 6nam 1 aJ ORNAMENTAL GRASS I Zr _ '±�1± 1 6) 6FT TALL I :El- 1 EVERGREEN SHRUB I n NO _ (. 3FT TALL 17 ORNAMENTAL GRASSI Or el '. '?: 3FTTAIL I "n% . � - EVERGREEN SHRUB ' kr[�ytt SFT TALL FLOWERING -11 •• DEOIDUOU53HRUB 1 a��-JJ• 00"SMO• ..„ I V 1 T Tl STONE WALK/WALL I a IS/A IONOG,III OR PLANTER I -1 'I II .e1. , I I Li I 11 ig 8 11111% 1 0E1 I Fz 1I --1 lia x� i ,, Y i1 # A ®,� 1� � 1 J I Eli / Lk I N, i. I I It=— '—i--.---1I I 1 i 111 1 ma B L I I[ .1 ] -.:91 fYl + 1 - $ BRIDGE STREET SIDEWALK t 9'.°I . 1 a 1 I t Jai i,"'� HI I! am 1 illy mx �! __. 111111 am - ..,,==,_.._ nnnnaml== u _z, nnn t _ I ...I...I Inh. ® cage cane I=11=1 o - o _ ._ - _- ' Q ExImNG PLANS•NORTH ELEVATION E-1.0 0E,-.7:...w-s- - - r.:s. oPt Tyre '„,i c,„liIi,i sib r ffi mg \ IllalliSal Ilill a ell Si II r-=-.. r- g .....••• Sas pm A1�” - JF i e& Inn ba.n -- .-------— \ a1 .1—L: 1 _ _ --- :=1`...,"':=1`...,"'wn y a LJ �� is�� ..'w ° -- gia - 1 _ ! o _, IL _ I - _ .gra — azcwao NEM —® HI ieeoi C - .. _ :__ ern 1 n b IVO 1 - - V o_ l-lp1I I - �� _ III' i iTitac °911111 r II a � I� r ......."'"..... - - _IIIIN�IIIIIII IIN SECT EN iiiiii Cr �: DEC(PORDI :_ ,ilir,IIIA i9I g _ O, mos En.xx _- -.1 a6 0 ,. �zN M-2.0 Code Review Thomas Douglas Architects Inc 74 Bridge Street,Northampton,MA 196 Pleasant St. Northampton,MA 413-585-0641 CODE REVIEW December 15, 2.015 74 Bridge Street, Northampton,MA The Historic College Inn of Northampton Applicable Building Code: MA 780 CMR Eighth Addition IBC, IEBC International EXISTING Building Code, zoos, ZONING DISTRICT: URC PROPOSED RENOVATIONS: PROJECT DESCRIPTION: • Addition of a 3 season porch • Addition of a new side deck • Addition of a new 4 story residential elevator • Renovations of the building will include t. New bridge framing and opmneings where elvstor accesses each floor level. z. Roof: small area of over roofing and new TPO roof sheathing Use Groups,Section aro • Rz. Non Transient Boarding House-No Changes proposed Construction Type • 58 Sprinkler System • The building is, or will be will be fully sprinkled with a NEPA i3 R system. • No changes are proposed other than new coverage in new areas Fire and Smoke Alarm&Detection • A manual fire alarm system and an automatic smoke detection system will be installed throughout the building. • An independent Fire Alarm Vendor will supply the final alarm plans and device specifications. Seismic Zone • See structural code review 1 of 7 Code Review Thomas Douglas Architects Inc 74 Bridge Street,Northampton,MA 196 Pleasant St. Northampton,MA 413-585-064t According to the IEBC this renovation is being reviewed as: Prescriptive Compliance Method, Chapter 3 303 Alterations:Alterations to any building or structure shall comply with the requirements of the IBC code for new construction. 303.3 Existing Structural elements:see attached structural review. Maximum Allowable Height/Area(section 5o3-5o6) • Section 504.2,Automatic sprinkler increase, states that for Group R buildings equipped throughout with an approved sprinkler system in accordance with Section 903.3.1.2 (an NFPA 13R system) the maximum building height is increased by 20 feet and maximum number of stones is increased by r story but shall not exceed 4 stories and 6o ft. • Section 506.3 does not allow an area increase for 13R systems.Type 513 construction allows a building up to 7,00o square feet per floor. The largest floor of this building is 2,057 square feet and complies with maximum areas. • The total allowable building area is calculated using the formula in section 506.4.1. For buildings 3 stories or more above grade, multiply the allowable building area per story from 506.1 by 3. The calculation is:7,000 sq ft per story x 3=za,000 square feet maximum building area.We propose a maximum building size of 7,688 square feet and complies with maximum areas. Maximum Allowable Height/Area Type 513 With NFPA 13R (section 503-506) Use: Rz sprinklers Maximum Height Allowed z story, 40 feet Maximum Area Allowed PER 7,000 FLOOR Height Increase per 506 (new Sprinklers&frontage 3 stories, 6o feet allowed) Note: the basement does not count as a story above grade.(50z.1) Area Increase per floor from 506 Sprinklers&frontage o (new allowed) Proposed Areas by Floor, gross Basement: 1991 First Floor 2014_ Second Floor 2057 Third Floor 1626 2 of 7 Code Review Thomas Douglas Architects Inc 74 Bridge Street,Northampton,MA 196 Pleasant St. Northampton,MA 413-585-0641 TOTAL 7,688 Proposed Height Rz space 3 story, 45'-4" tall Fire Resistive Required Types of Building Element Type 5B Construction,Table Gm&Goa Primary Structural o Frame Bearing walls, Exterior o Bearing walls, Interior o Nonbearing walls and o partitions, exterior Nonbearing walls and o i_ partitions, interior Floor construction and o secondary members Roof construction and o secondary members 508.4 7073.8 Separated Occupancies There is only one proposed type of occupancy in this building.There are no separated occupancies. 5o8.4.z lllowable building area: 506.1 Building area modifications:Building areas from Table 5o3 shall NOT be permitted to be increased due to frontage and sprinklers. FIRE SEPARATIONS: Table 508.2.5 Incidental Accessory Occupancies • Furnace room:Where any piece of equipment is over 400,000 BTU per hour input,a t hour fire separation or sprinklers are required. • Laundry rooms over too square feet:a i-hour fire separation or sprinklers are required. Table 508.4 Required Separation of Occupancies • With a NFPA 13R sprinkler system and type 5B construction: • 42,0.2 Separation Walls:Walls separating dwelling units in the same building shall be constructed as fire partitions. • 709.1 Fire partitions,709.3,toi8a,Fire Resistance rating, 3 of 7 Code Review Thomas Douglas Architects Inc 74 Bridge Street,Northampton,MA 146 Pleasant St. Northampton,MA 413-5854)641 • r. Corridors:Corridor walls shall have a i-hour rating because of the NFPA 13R system.The exception allowed by table ro18.1 is not in effect. • Dwelling unit and sleeping unit separations in buildings of type 2B,3B and 5B construction shall have fire resistance ratings of not less than i hour in buildings equipped with an NFPA 13R automatic sprinkler system. • 712.3 Horizontal Assemblies, Fire resistance rating: • Fire separations required between R use and R use: None Required • Interior Stairway enclosures.see Exit enclosures,roan below. 707.8 Penetrations:permitted by section 1022.4 1022.4 Penetrations into and openings through an exit enclosure are prohibited except for required exit doors, equipment and duct work necessary for independent ventilation or pressurization, sprinkler piping, standpipes, and electrical raceways serving the exit enclosure. 1207 Sound Transmission • 1207.2 Mr-borne sound:Walls,partitions,and floor/ceiling assemblies separating dwelling units from each other or from public or service areas will be constructed to have required STC value of 5o.See the construction drawings for code compliant assemblies. • 1207.3 Structure-borne sound: Floor/ceiling assemblies separating dwelling units from each other or from public or service areas will be constructed to have required impact insulation class (IIC) rating of not less than 5o. See the construction drawings for code compliant assemblies. • See drawings for STC wall details and ratings. Means of Egress Section mood prescribes that the width of an interior stairway cannot be less than 44 inches. No changes to existing. 1118.z Corridor Width The required corridor width for this project (with an occupancy of less than 5o) is 36".Widths of corridors in this project vary,but the most narrow corridor in this project is 3'-8". No changes to existing. ror8.4 Dead ends 4 of 7 Code Review Thomas Douglas Architects Inc 74 Bridge Street,Northampton,MA 196 Pleasant St. Northampton,MA 413-585-0641 With an NFPA 13R automatic sprinkler system, dead end corridors are limited to 20 feet.This project does not have dead end corridors exceeding zo feet. No changes to existing. 1015 Exit and Exit Access Doorways,ion Number of exits and continuity In group Rz and R3 occupancies,one means of egress is permitted within and from individual dwelling units with a maximum occupant load of 20 where the dwelling unit is equipped throughtout with an automatic sprinker system of NEPA 13 and 13R systems. 1o16.1 Travel Distance • Exit access travel distance(1016.1) 250 feet,but modified by 1o21.2 below. This distance is the same for NFPA 13 and 13R systems. • No changes to existing. Travel With NO With sprinkler Proposed max travel Distance sprinkler System distance (ro26.1) System Attic space 250' 74 feet from attic corner to 2"d floor exit stair razz Exit Enclosures Interior exit stairways and interior exit ramps shall be enclosed with Fire Barriers constructed in accordance with 707. Exit enclosures shall have a fire resistance rating of not less than 1 hour where connecting less than 4 stories. No changes to existing. This building has an existing interior and exterior exit stair less than 4 stories and we estimate that the interior walls have a fire resistance of 1 hour.The rating of the existing doors is unknown. No changes to existing. Exception: Stairs in apartments:Stairways serving and contained within a single residential dwelling unitor sleeping unit in Group R1, R2,or R3 are not required to be enclosed. No changes to existing. uo&z Minimum Ceiling Height requirements 5 of 7 Code Review Thomas Douglas Architects Inc 74 Bridge Street,Northampton,MA 196 Pleasant St. Northampton,MA 413-585-0641 Minimum required ceiling height:7-6" If any room in a building has a sloped ceiling, the prescribed ceiling height for the room is required in % of the area.Any portion of the room measuring less than 5 feet from the finished floor to the ceiling shall not be included in any computation of the minimum area thereof. No changes to existing. 1029 Emergency Escape and Rescue Exception t in section ia29 allows sprinkler systems (NFPA 13 and 13R systems) to be used in lieu of emergency escape and rescue openings. 805.2 Means of Egress Lighting Means of egress lighting will be installed throughout the entire building 805.3 Exit signs Means of egress throughout the entire building will have exit signs installed, 705.4.2 Door swing. All means of egress doors will swing in the direction of travel. too8a.ro,705.4.4 Panic hardware: Not required since this is not an A or E or H use. Chapter 9 Fire Protection Systems: 903.2.8 Group R: An NFPA 13R automatic sprinkler system shall be provided throughout all buildings with a Group R fire area. The fire alarm vendor will supply a fire alarm narrative. 7rr Energy Conservation Required values according to the MA stretch code for this Existing building: MA:climate zone 5A All existing ceilings, walls or floor cavities of the building envelope exposed or accessible during construction will be filled with insulation that meets or exceeds an R-value of R-3.5 per inch. The roof will be insulated and air sealed. Any new replacement windows will have a maximum U value of 04 Any new entrance doors will have a maximum U value of o.8 Level 3 alterations are permitted without requiring the entire building to comply with the International Energy Conservation Code. Alterations (new construction) shall comply with the International Energy Conservation Code. A building that undergoes Level 3 alterations is required to meet a certain level of energy compliance. 6 of 7 Code Review Thomas Douglas Architects Inc 74 Bridge Street,Northampton,MA 196 Pleasant St. Northampton,MA 413-585-0641 Any new element within the work area is required to meet the International Energy Conservation Code. Elements within the building that are not being affected do not heed to be evaluated and do not nee to comply with the energy provisions. Essentially the entire building is not required to meet the energy provisions; only a degree of possible improvement in the energy performance of the building is intended to be achieved by making the new elements meet the IECC. In certain cases where the reconfiguration of the space might have resulted in the creation of new spaces the newly created space should be evaluated as a whole for compliance with the energy provisions even though some of the element within the space might actually not have been altered. Likewise, in a case where an existing mechanical system is being extended to other areas or new ductwork is being installed to reconfigure and reroute the ducts to various spaces, it is only required to have the new elements meet the energy provisions and not the entire system. 8o6 Accessibility CMR 521 The work is within a private dwelling unit &thus does not need to be in compliance with CMR 521 • End of Document 7 of 7