Lot 26, Title 5 Perc Test, 1991 CONSULTANTS , INC.
• Land Surveying
• Civil Engineering
•Septic Systems
• Land Development
August 27 , 1991
TO: Peter McErlain
Board of Health
210 Main Street
Northampton, MA 01060
The
at
data
P.O. Box 60189• Florence MA •01060-0189• (413) 586-7794
thq perc results from the tests taken
dad on 8/27/91 :
Test hole "A" : soak start - 9: 33
12" - 9: 48
11" - 10 :00
10" - 10 : 16
9" - 10. 36
- >1"/30min - FAi4
Test hole "B" : soak start - 1: 11
12" - 1 : 27
11" - 1 : 29
10" - 1 : 31
9" - 1 : 34 : 15
8" - 1: 37 : 30
7" - 1:41 : 30
6" - 1 :46:00
1"/5min
Note the design engineer should use the slowest results
available for the perc rate . Also, both locations have been
staked with perc date noted to allow proper position of leach
field .
Sincerely,
Steven J . Frederick, C .E.
SJF/rlo
cc: M. Howard
A229. 1