332 Title 5 Report 2016 • Commonwealth of Massachusetts
Owner
information is
required for
every page.
Important:
When filling out
forms on the
computer,use
only the tab key
to move your
cursor-do not
use the return
key.
4 lm
MVP
(Sins•3/13
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
Gary Warner
Property Address
332 North Farms Road
Owners Name
Northampton MA 01062 May 13, 2016
City/Town State Zip Code Date of Inspection
Inspection results must be submitted on this form. Inspection forms may not be altered in any
way. Please see completeness checklist at the end of the form.
A. General Information
1. Inspector:
Timothy E. Maginnis
Name of Inspector
Company Name
70 Montague Road
Company Address
Westhampton
City/Town
(413)527-5291
Telephone Number
MA
State
SI 1039
License Number
01027
Zip Code
B. Certification
I certify that I have personally inspected the sewage disposal system at this address and that the
information reported below is true, accurate and complete as of the time of the inspection. The inspection
was performed based on my training and experience in the proper function and maintenance of on site
sewage disposal systems. I am a DEP approved system inspector pursuant to Section 15.340 of
Title 5(310 CMR 15.000).The system:
® Passes
❑ Conditionally Passes ❑ Fails
❑
N _ aluation by the Local Approving Authority
May, 17, 2016
Date
Th-', } I I submit a copy of this inspection report to the Approving Authority(Board
of H ,1 tt.'X30 days of completing this inspection. If the system is a shared system or
has a dA 000 gpd or greater, the inspector and the system owner shall submit the
report to the appropriate regional office of the DEP. The original should be sent to the system owner
and copies sent to the buyer, if applicable, and the approving authority.
****This report only describes conditions at the time of inspection and under the conditions of use
at that time.This inspection does not address how the system will perform in the future under
the same or different conditions of use.
Title 5 Official In
ion Form Subsurface Sewage Disposal System•Page 1 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
Gary Warner
Property Address
332 North Farms Road
Owner Owners Name
information is Northampton required for P MA 01062 May 13, 2016
every page. City/Town State Zip Code Date of Inspection
tans o 113
B. Certification (cont.)
Inspection Summary: Check A,B,C,D or E/always complete all of Section D
A) System Passes:
® I have not found any information which indicates that any of the failure criteria described
in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are
indicated below.
Comments:
N/A
B) System Conditionally Passes:
❑ One or more system components as described in the"Conditional Pass°section need to be
replaced or repaired. The system, upon completion of the replacement or repair, as approved by
the Board of Health, will pass.
Check the box for"yes", "no"or"not determined"(Y, N, ND)for the following statements. If"not
determined," please explain.
The septic tank is metal and over 20 years old*or the septic tank(whether metal or not) is
structurally unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System
will pass inspection if the existing tank is replaced with a complying septic tank as approved by the
Board of Health.
•A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of
Compliance indicating that the tank is less than 20 years old is available.
❑ Y ❑ N
N/A
❑ ND(Explain below):
Title S Official InapeGion Fenn Subsurface Sewage Disposal Sys
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
Gary Warner
Property Address
332 North Farms Road
Owner Owners Name
information is Northampton required for P MA 01062 May 13, 2016
every page. City/Town State Zip Code Date of Inspection
15ins•3113
B. Certification (cont.)
❑ Pump Chamber pumps/alarms not operational. System will pass with Board of Health approval if
pumps/alarms are repaired.
B) System Conditionally Passes(cont.):
❑ Observation of sewage backup or break out or high static water level in the distribution box due
to broken or obstructed pipe(s)or due to a broken, settled or uneven distribution box. System will
pass inspection if(with approval of Board of Health):
❑ broken pipe(s)are replaced
❑ obstruction is removed
❑ distribution box is leveled or replaced
N/A
❑ Y ❑ N ❑ ND(Explain below):
❑ Y ❑ N ❑ ND(Explain below):
❑ Y O N O NO (Explain below):
❑ The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The
system will pass inspection if(with approval of the Board of Health):
❑ broken pipe(s)are replaced ❑ Y ❑ N ❑ ND(Explain below):
❑ obstruction is removed ❑ Y ❑ N ❑ ND(Explain below):
N/A
C) Further Evaluation is Required by the Board of Health:
❑ Conditions exist which require further evaluation by the Board of Health in order to determine if
the system is failing to protect public health, safety or the environment.
1. System will pass unless Board of Health determines in accordance with 310 CMR
15.303(1)(b)that the system is not functioning in a manner which will protect public health,
safety and the environment:
❑ Cesspool or privy is within 50 feet of a surface water
❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh
Title 5 Official Inspection Fanr Subsurface Sewage Disposal System•Page 3 of 17
Owner
information is
required for
every page.
thins•3/13
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
Gary Warner
Property Address
332 North Farms Road
Owners Name
Northampton MA 01062 May 13, 2016
City/Town State Zip Code Date of Inspection
B. Certification (cont.)
2. System will fail unless the Board of Health(and Public Water Supplier,if any)
determines that the system is functioning in a manner that protects the public health,
safety and environment:
❑ The system has a septic tank and soil absorption system (SAS)and the SAS is within
100 feet of a surface water supply or tributary to a surface water supply.
❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water
supply.
❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water
supply well.
❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or
more from a private water supply well!*.
Method used to determine distance: N/A
•• This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal
coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal
to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis must
be attached to this form.
3. Other:
N/A
D) System Failure Criteria Applicable to All Systems:
You must indicate"Yes"or"No"to each of the following for all inspections:
Yes No
❑ ® Backup of sewage into facility or system component due to overloaded or
clogged SAS or cesspool
❑ ® Discharge or ponding of effluent to the surface of the ground or surface waters
due to an overloaded or clogged SAS or cesspool
❑ ® Static liquid level in the distribution box above outlet invert due to an overloaded
or clogged SAS or cesspool
❑ ® Liquid depth in cesspool is less than 6" below invert or available volume is less
than%day flow
rIle s Official inspection Form:Subsurface Sewage Deposal System•Page a N 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
Gary Warner
Property Address
332 North Farms Road
Owner Owner's Name
required for1S Northampton MA 01062 May 13, 2016
every page. City/Town State Zip Code Date of Inspection
,Sins•3/13
B. Certification (cont.)
Yes No
❑ ® Required pumping more than 4 times in the last year NOT due to clogged or
obstructed pipe(s). Number of times pumped:
❑ ® Any portion of the SAS, cesspool or privy is below high ground water elevation.
❑ ® Any portion of cesspool or privy is within 100 feet of a surface water supply or
tributary to a surface water supply.
❑ ® Any portion of a cesspool or privy is within a Zone 1 of a public well.
❑ ® Any portion of a cesspool or privy is within 50 feet of a private water supply
well.
❑ ® Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet
from a private water supply well with no acceptable water quality analysis. [This
system passes if the well water analysis, performed at a DEP certified
laboratory,for fecal coliform bacteria indicates absent and the presence
of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,
provided that no other failure criteria are triggered.A copy of the analysis
and chain of custody must be attached to this form.]
The system is a cesspool serving a facility with a design flow of 2000gpd-
10,000gpd.
The system fails. I have determined that one or more of the above failure
criteria exist as described in 310 CMR 15.303, therefore the system fails. The
system owner should contact the Board of Health to determine what will be
necessary to correct the failure.
❑ El
E) Large Systems: To be considered a large system the system must serve a facility with a
design flow of 10,000 gpd to 15,000 gpd.
For large systems, you must indicate either"yes" or"no"to each of the following, in addition to the
questions in Section D.
Yes No
❑ ® the system is within 400 feet of a surface drinking water supply
❑ ® the system is within 200 feet of a tributary to a surface drinking water supply
❑ ® the system is located in a nitrogen sensitive area(Interim Wellhead Protection
Area—IWPA)or a mapped Zone II of a public water supply well
If you have answered "yes"to any question in Section E the system is considered a significant threat,
or answered"yes" in Section D above the large system has failed. The owner or operator of any large
system considered a significant threat under Section E or failed under Section D shall upgrade the
system in accordance with 310 CMR 15.304. The system owner should contact the appropriate
regional office of the Department.
TiOe 5 Ofri al Inspection Form Subsurface Sewage Disposal System•Pape 5 0117
Owner
information is
required for
every page.
%sins•3113
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
Gary Warner
Property Address
332 North Farms Road
Owners Name
Northampton MA 01062 May 13, 2016
City/Town State Zip Code Date of Inspection
C. Checklist
Check if the following have been done. You must indicate"yes°or"no"as to each of the following:
Yes No
Pumping information was provided by the owner, occupant, or Board of Health
Were any of the system components pumped out in the previous two weeks?
Has the system received normal flows in the previous two week period?
Have large volumes of water been introduced to the system recently or as part of
this inspection?
Were as built plans of the system obtained and examined?(If they were not
available note as N/A)
Was the facility or dwelling inspected for signs of sewage back up?
Was the site inspected for signs of break out?
Were all system components, excluding the SAS, located on site?
Were the septic tank manholes uncovered, opened, and the interior of the tank
inspected for the condition of the baffles or tees, material of construction,
dimensions, depth of liquid, depth of sludge and depth of scum?
Was the facility owner(and occupants if different from owner) provided with
information on the proper maintenance of subsurface sewage disposal systems?
The size and location of the Soil Absorption System(SAS)on the site has
been determined based on:
Existing information. For example, a plan at the Board of Health.
Determined in the field (if any of the failure criteria related to Part C is at issue
approximation of distance is unacceptable)[310 CMR 15.302(5)]
D. System Information
Residential Flow Conditions:
Number of bedrooms(design):
Unknown
Number of bedrooms(actual):
DESIGN flow based on 310 CMR 15.203(for example: 110 gpd x#of bedrooms):
4
440 gpd
Title 5 Official Inspection Fenn Subsurface Sewage Dispal System Page 6 of 9
Owner
information is
required for
every page.
bins•3/13
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
Gary Warner
Property Address
332 North Farms Road
Owners Name
Northampton MA 01062 May 13, 2016
City/Town State Zip Code Date of Inspection
D. System Information
Description:
1,500 gallon septic tank and a leaching pit. This is a large pit. It's top is about 12 below grade. It
measures 7'deep.
Number of current residents:
Does residence have a garbage grinder?
Is laundry on a separate sewage system? (Include laundry system inspection
information in this report.)
Laundry system inspected?
Seasonal use?
Water meter readings, if available(last 2 years usage(gpd)):
Detail:
Current meter reading !
4
❑ Yes ® No
❑ Yes ® No
❑ Yes ❑ No
❑ Yes ® No
0059-14446
Sump pump?
Last date of occupancy:
Commercialllndustrial Flow Conditions:
Type of Establishment:
Design flow(based on 310 CMR 15.203):
Basis of design flow (seats/persons/sq.ft., etc.):
Grease trap present?
Industrial waste holding tank present?
Non-sanitary waste discharged to the Title 5 system?
Water meter readings, if available:
❑ Yes ® No
Currently
occupied
N/A
N/A
Gallons per day(gpd)
N/A
❑ Yes ❑ No
❑ Yes ❑ No
❑ Yes ❑ No
N/A
Title 5 Official Inspection Form.Subsurface Sewage Disposal System•Page 7 of 17
Owner
information is
required for
every page.
15ins•3113
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
Gary Warner
Property Address
332 North Farms Road
Owners Name
Northampton MA 01062 May 13, 2016
City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Last date of occupancy/use:
Other(describe below):
N/A
Date
General Information
Pumping Records:
Source of information:
Was system pumped as part of the inspection?
If yes, volume pumped:
How was quantity pumped determined?
Reason for pumping:
Type of System:
Owner: Gary Warner
N/A
gallons
N/A
N/A
❑ Yes ® No
❑ Septic tank, distribution box, soil absorption system
❑ Single cesspool
❑ Overflow cesspool
❑ Privy
❑ Shared system(yes or no)(if yes, attach previous inspection records, if any)
❑ Innovative/Alternative technology.Attach a copy of the current operation and
maintenance contract(to be obtained from system owner)and a copy of latest
inspection of the I/A system by system operator under contract
❑ Tight tank. Attach a copy of the DEP approval.
Other(describe):
No Distribution box
Tele 5O Official Inspection Form Subsurface Sewage Disposal System•Page 8 of 17
Owner
information is
required for
every page.
thins 3113
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
Gary Warner
Property Address
332 North Farms Road
Owner's Name
Northampton MA 01062 May 13,2016
City/Town State Zip Code Date of Inspection
D. System Information (cant.)
Approximate age of all components, date installed (if known) and source of information:
The septic tank was installed in 2008 by Bob Wade. The leaching pit was installed in 1976. Source
of information is Gary Warner, owner.
Were sewage odors detected when arriving at the site?
Building Sewer(locate on site plan):
Depth below grade:
Material of construction:
❑ cast iron
®40 PVC ❑ other(explain):
❑ Yes ® No
2.5+
feet
Distance from private water supply well or suction line: N/A-This site is served by municipal
water supply.
Comments(on condition of joints, venting, evidence of leakage, etc.):
Pipes appeared to be sound. There is no evidence leakage and venting is proper.
Septic Tank(locate on site plan):
Depth below grade:
Material of construction:
12"
feet
®concrete ❑ metal ❑fiberglass ❑ polyethylene ❑other(explain)
This tank was installed in 2008 and is a 1,500 gallon tank. It is structurally sound and there are no
leaks into or out of it.
If tank is metal, list age:
N/A
years
Is age confirmed by a Certificate of Compliance? (attach a copy of certificate)
Dimensions: N/A
Sludge depth: N/A
❑ Yes ❑ No
This s Dniaal Inspavcn Form:ou.v(race Sewage Disposal System.Page eat 17
Owner
information is
required for
every page.
151ns•3113
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
Gary Warner
Property Address
332 North Farms Road
Owners Name
Northampton MA 01062 May 13, 2016
City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Septic Tank(cont.)
Distance from top of sludge to bottom of outlet tee or baffle
Scum thickness
N/A
N/A
Distance from top of scum to top of outlet tee or baffle N/A
Distance from bottom of scum to bottom of outlet tee or baffle N/A
How were dimensions determined? N/A
Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity,
liquid levels as related to outlet invert, evidence of leakage, etc.):
This tank was pumped on March 26, 2016 and therefore a negligable amount of scum and sludge
was present The inlet and outlet tees are pvc and in good working order. The liquid level was even
the outlet invert. There was no signs of failure or leakage. This tank is in sound condition.
Recommend pumping at least every three years. THERE IS AN EFFLUENT FILTER ON THE
OUTLET END OF THE TANK. It was removed, cleaned and replaced as a result of this inspection.
IT SHOULD BE CLEANED AT LEAST ONCE PER YEAR.
Grease Trap(locate on site plan):
Depth below grade: N/A
feet
Material of construction:
❑concrete ❑ metal ❑fiberglass ❑ polyethylene ❑other(explain):
Dimensions:
Scum thickness
Distance from top of scum to top of outlet tee or baffle
Distance from bottom of scum to bottom of outlet tee or baffle
Date of last pumping:
N/A
N/A
N/A
N/A
N/A
Date
Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 10 at 17
Owner
information is
required for
every page.
Wins•Y1
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
Gary Warner
Property Address
332 North Farms Road
Owner's Name
Northampton MA 01062 May 13, 2016
City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity,
liquid levels as related to outlet invert, evidence of leakage, etc.):
N/A
Tight or Holding Tank(tank must be pumped at time of inspection) (locate on site plan):
N/A
Depth below grade:
Material of construction:
❑ concrete ❑ metal
❑fiberglass ❑ polyethylene ❑ other(explain):
Dimensions:
Capacity:
Design Flow:
Alarm present:
Alarm level:
Date of last pumping:
N/A
N/A
N/A
gallons
N/A
gallons per day
❑ Yes ❑ No
Alarm in working order: ❑ Yes ❑ No
N/A
Date
Comments(condition of alarm and float switches, etc.):
N/A
Attach copy of current pumping contract(required). Is copy attached? ❑ Yes ❑ No
Titles Official In•petllon Form Subsurface sewage Disposal system.Page 11 of 17
Owner
information is
required for
every page.
t5ins•3/13
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
Gary Warner
Property Address
332 North Farms Road
Owners Name
Northampton MA 01062 May 13,2016
City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Distribution Box(if present must be opened)(locate on site plan):
N/A
Depth of liquid level above outlet invert
Comments (note if box is level and distribution to outlets equal, any evidence of solids carryover, any
evidence of leakage into or out of box, etc.):
NO DISTRIBUTION BOX FOR THIS SYSTEM.
Pump Chamber(locate on site plan):
Pumps in working order:
Alarms in working order:
❑ Yes ❑ No`
❑ Yes ❑ No`
Comments(note condition of pump chamber, condition of pumps and appurtenances, etc.):
N/A
If pumps or alarms are not in working order, system is a conditional pass.
Soil Absorption System(SAS)(locate on site plan, excavation not required):
If SAS not located, explain why:
The SAS is approximately 40 years old. It was installed in 1976 and is good working order. At the
time of this inspection there was about 6"of sludge and about 6"liquid in the bottom of the leaching
pit. The cover is about 12" below grade and the pit itself is 7'deep. No groundwater infiltration.
rifle 5 foal Inspection Form Subsurface Sewage Disposal System•Page 12 of 17
Owner
information is
required for
every page.
Sins.3.13
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
Gary Warner
Property Address
332 North Farms Road
Owners Name
Northampton MA 01062 May 13, 2016
City/Town State Zip Code Date of Inspection
D. System Information (coot.)
Type:
❑ leaching pits number:
❑ leaching chambers number:
❑ leaching galleries number:
❑ leaching trenches number, length:
❑ leaching fields number, dimensions:
❑ overflow cesspool number:
❑ innovative/alternative system
1 (47 7'deep
Type/name of technology:
Comments(note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition of
vegetation, etc.):
No evidence of ponding, damp soil or hydraulic failure. The vegetation is normal lawn grass.
Cesspools(cesspool must be pumped as part of inspection) (locate on site plan):
N/A
Number and configuration
Depth—top of liquid to inlet invert
Depth of solids layer
Depth of scum layer
Dimensions of cesspool
Materials of construction
Indication of groundwater inflow
N/A
N/A
N/A
N/A
N/A
❑ Yes ❑ No
Tills 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 13 or 1/
Owner
information is
required for
every page.
bins 3/13
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
Gary Warner
Property Address
332 North Farms Road
Owners Name
Northampton MA 01062 May 13, 2016
City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Comments(note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation,
etc.):
N/A
Privy(locate on site plan):
Materials of construction:
Dimensions
N/A
N/A
Depth of solids N/A
Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation,
etc.):
N/A
Title 5 Official Inspec,on Form Subsurface savage Disposal system.Page 14 of 17
Owner
information is
required for
every page.
Sins•3/13
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form- Not for Voluntary Assessments
Gary Warner
Property Address
332 North Farms Road
Owner's Name
Northampton
Cityrtown
MA 01062 May 13, 2016
State Zip Code Date of Inspection
D. System Information (cont.)
Sketch Of Sewage Disposal System: Provide a view of the sewage disposal system, including ties to
at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate
where public water supply enters the building. Check one of the boxes below: •
❑ hand-sketch in the area below
® drawing attached separately
SeE N E >C7 rAck
Title 5 Official Inspection Form Sub
Sewage Disposal System Page 15 of 17
NORTH FARMS ROAD \ FLORENCE, MASSACHUSETTS
Existing leaching pi
Leaching pit cover ("D"
(12" to cover — 7' deep)
4° pvc solid pipe
Existing 1,500 gal. septic tank
(12" to cover)
Pumpout man—hole ("C
4" pvc solid pipe for laundry wastewate
AS-BUILT DIMENSIONS
Title-5
Inspection plan
332 N. Farms Rd.
Florence, MA
May 13, 2016
'A' to 'C'
=
23'-5'
'B' to 'C' =
23'-6'
'A' to 'D'
=
37'-0'
'B' to 'D' =
51'-6'
Title-5
Inspection plan
332 N. Farms Rd.
Florence, MA
May 13, 2016
Owner
information is
required for
every page.
'Sins•3/13
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form- Not for Voluntary Assessments
Gary Warner
Property Address
332 North Farms Road
Owner's Name
Northampton MA 01062 May 13, 2016
City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Site Exam:
E Check Slope
E Surface water
E Check cellar
E Shallow wells
>8'
Estimated depth to high ground water: feet
Please indicate all methods used to determine the high ground water elevation:
❑ Obtained from system design plans on record
If checked, date of design plan reviewed: Date
• Observed site (abutting property/observation hole within 150 feet of SAS)
❑ Checked with local Board of Health -explain:
• Checked with local excavators, installers-(attach documentation)
❑ Accessed USGS database-explain:
You must describe how you established the high ground water elevation:
-observed no infiltration into septic tank.
-The bottom of the leaching pit is about 8' below grade and no infiltration of groundwater
was observed
-reviewed USDA Soil Survey
-observed no water stains in the basement. The foundation wall is constructed of field stone.
Before filing this Inspection Report, please see Report Completeness Checklist on next page.
Tales ONcual Inspection Form Subsurface Sewage Disposal System•Page 16 N 17
Owner
information is
required for
every page.
t5ins•113
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
Gary Warner
Property Address
332 North Farms Road
Owner's Name
Northampton
City/Town
MA 01062 May 13, 2016
State Zip Code Date of Inspection
E. Report Completeness Checklist
Inspection Summary: A, B, C, D, or E checked
® Inspection Summary D(System Failure Criteria Applicable to All Systems)completed
El System Information—Estimated depth to high groundwater
El Sketch of Sewage Disposal System either drawn on page 15 or attached in separate file
Title 5 Official Inspection Form Subsurface Sewage Disposal System•Page 17 of 17