574 Septic Inspection Form 2003 COMMONWEALTH OF MASSACHUSEI 1 S
EXECUTIVE OFFICE OF ENVIRONMENTAL AFFAIR
DEPARTMENT OF ENVIRONMENTAL PROTECTI
TITLE 5
OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM FORM
PART A
CERTIFICATION
Property Address: 574 Havdenville Road, Northampton, MA
Owner's Name: John Zak, Executor
Owners Address: 94 Marine St. . Farmingdale, NY 11735
Date of Inspection: 8/6/03
Copy to: Board of Health, Northampton; Phil Pless
Witness: Number: SS0S-825
Name of Inspector: Thomas S. Leue
Company Name: Homestead Inc.
Mailing Address: 1§AL Cape St. . Williamsburg. MA 01096
Telephone Number. (413) 628-4533
AUG 1 2 R 2003
"iAMpToN
87;;;;,..
OAF00E HEAITF!
CERTIFICATION STATEMENT
I certify that I have personally inspected the sewage disposal system at this address and that the information
reported below is true, accurate and complete as of the time of the inspection. The inspection was performed
based on my training and experience in the proper function and maintenance of on-site sewage disposal
systems. I am a DEP approved system inspector pursuant to Section 15.340 of Title 5 (310 CMR 15.000).
The septic system condition must be evaluated and classified into one of the following four conditions:
Passes
Conditionally Passes
Needs Further Evaluation by the Local Approving Authority
Fails
The system condition: Passes
Inspector's Signature:
Date: 8uauat 7 . 2001
The System Inspector shall submit a copy of this inspection report to the Approving Authority(Board of Health
of DEP)within thirty (30)days of completing this inspection. If the system is a shared system or has a design
flow of 10,000 gpd or greater,the inspector and the system owner shall submit the report to the appropriate
regional office of the DEP. The original should be sent to the system owner and copies to the buyer, if
applicable and the approving authority.
Notes and Comments
****This report only describes conditions at the time of inspection and under the conditions of use at that
time.This inspection does not address how the system will perform in the future under the same or
different conditions of use.
Title 5 Inspection Form 6/15/2000
page 1 of 9
Homestead Inc.
OFFICIAL INSPECTION FORM • NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM FORM
PART A
CERTIFICATION
Property Address: 574 Havdenville Road Northampton. MA
Owner: John Zak. Executor
Date of Inspection: 8/6/03
Inspection Summary: Check A,B,C,I)or E/ALWAYS complete all of Section D:
A. System Passes:
Y 1 have not found any information which indicates that any of the failure criteria as described in 310
CMR 15303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below.
Comments: _
B] System Conditionally Passes:
N One or more system components as described in the "Conditional Pass"section need to be replaced or
repaired. The system, upon completion of the replacement or repair, as approved by the Board of
Health, will pass. Answer yes,no,or not determined(Y,N, or ND) in the for the following
statements. If"not determined"please explain.
(1) N The septic tank is metal and over 20 years old* or the septic tank(whether metal or not) is
structurally unsound, exhibits substantial infiltration or exfiltration, or tank failure is imminent. The system will
pass inspection if the existing septic tank is replaced with a complying septic tank as approved by the Board of
Health. *A metal septic tank will pass inspection if it is structurally sound,not leaking and if a Certificate of
Compliance indicating that the tank is less than 20 years old is available.
ND explain:
(2) N Observation of sewage backup or break out or high static water level in the distribution box due
to broken or obstructed pipe(s)or due to a broken, settled or uneven distribution box. System will pass
inspection if(with approval by the Board of Health). broken pipe(s)are replaced
obstruction is removed
distribution box is levelled or replaced
ND explain:
(3) N The system required pumping more than four times a year due to broken or obstructed pipe(s).
The system will pass inspection if(with approval of the Board of Health):
broken pipe(s) are replaced
obstruction is removed
ND explain:
(4) N Other: explain: _
C] Further Evaluation is Required by the Board of Health:
N Conditions exist which require further evaluation by the Board of Health in order to determine if the
system is failing to protect the public health, safety or the environment:
1) System will pass unless Board of Health determines in accordance with 310 CMR 15.303(1)(6) that
the system is not functioning in a manner which will protect public health, safety and the environment:
Cesspool or privy is within 50 feet of a surface water.
Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh.
Title 5 Inspection Form 6/15/2000
page 2 of 9 Homestead Inc.
OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM FORM
PART A
CERTIFICATION (continued)
Property Address: 574 Haydenville Road Northampton MA
Owner: John Zak, Executor
Date of Inspection: 8/6/03
2) System will fail unless Board of Health (and Public Water Supplier,if any) determines that the
system is functioning in a manner that protects the public health, safety and environment:
The system has a septic tank and soil absorption system(SAS)and the SAS is within 100 feet of a
surface water supply or tributary to a surface water supply.
The system has a septic tank and SAS and the SAS is within a Zone I of a public water supply.
The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well.
The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a
private water supply well** Method used to determine distance
** This system passes if the well water analysis, performed at a DEP certified laboratory,for coliform bacteria
and volatile organic compounds indicates that the well is free from pollution from that facility and the presence
of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria
are triggered.A copy of the analysis must be attached to this form.
3) Other:
D] System Failure Criteria applicable to all systems:
You must indicate either"Yes" or"No"as to each of the following for au inspections:
YES (Y) or NO(N)
N Backup of sewage into facility or system component due to an overloaded or clogged SAS or cesspool.
N Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or
clogged SAS or cesspool.
N Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or
cesspool.
N Liquid depth in cesspool is less than 6"below invert or available volume less than 1/2 day flow.
N Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s).Number
of times pumped
N Any portion of the SAS, cesspool or privy is below high ground water elevation.
N Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface
water supply.
N Any portion of cesspool privy is within a Zone I of a public well.
N Any portion of cesspool or privy is within 50 feet of a private water supply well.
N Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water
supply with no acceptable water quality analysis. [This system passes if the well water analysis,
performed at a DEP certified laboratory, for coliform bacteria and volatile organic compounds
indicates that the well is free from pollution from that facility and the presence of ammonia
nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria
are triggered.A copy of the analysis must be attached to this form]
N The system fails. I have determined that one or more of the above failure criteria exist as defined in 310
CM 15.303, therefore the system fails. The system owner should contact the Board of Health should be
contacted to determine what will be necessary to correct the failure.
Title 5 Inspection Form 6/15/2000
page 3 of 9
Homestead Inc.
OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM FORM
PART A
CERTIFICATION (continued)
Property Address: 574 Haydenville Road, Northampton, MA
Owner: John Zak Executor
Date of Inspection: 8/6/03
E] Large Systems:
To be considered a large system the system must serve a facility with a design flow of 10,000 to 15,000 gpd.
You must indicate either "Yes" or`No"as to each of the following:
The following criteria apply to large systems in addition to the criteria above:
YES (Y) or NO(N)
N the system is within 400 feet of a surface drinking water supply
N the system is within 200 feet of a tributary to a surface drinking water supply
N the system is located in a nitrogen sensitive area(Interim Wellhead Protection Area-IWPA) or a
mapped Zone II of a public water supply well)
If you answered "yes" to any question in Section E the system is considered a significant threat, or answered
"yes"in Section D above the large system has failed.The owner or operator of any large system considered a
significant threat under Section E or failed under Section D shall upgrade the system in accordance with 310
CMR 15.304. The system owner should contact the appropriate regional office of the Department.
PART B• CHECKLIST
Check if the following have been done. You must indicate "ves" or "no" as to each of the following,
YES (Y) or NO (N)
Y Pumping information was provided by the owner,occupant or Board of Health.
• Were any of the system components pumped out in the previous two weeks?
• Has the system received normal flows in the previous two week period?
N Have large volumes of water been introduced to the system recently or as part of the inspection?
N/A, Were as built plans of the system obtained and examined? (If they are not available note as N/A)
• Was the facility or dwelling was inspected for signs of sewage back up?
• Was the site was inspected for signs of break out?
Y Were all system components,excluding the SAS,located on site?
Y Were the septic tank manholes uncovered,opened,and the interior of the septic tank inspected for the
condition of the baffles or tees,material of construction,dimensions,depth of liquid,depth of sludge and depth of scum?
The size and location of the Soil Absorption System(SAS) on the site has been determined based on:
N a) Existing information. For example, a plan at the Board of Health.
Y b) Determined in the field (if any of the failure criteria related to Part C is at issue
approximation of distance is unacceptable) (15.302(3)(6)].
N The facility owner(and occupants, if different from owner)were provided with information on
proper maintenance of Subsurface Sewage Disposal Systems(SSDS).
RESOURCES:
Department of Environmental Protection,Western Regional Office,436 Dwight St., Springfield, MA
01103, (413) 784-1100;Title 5 Hotline-(800) 266-1122
Tide 5 Inspection Form 6/15/2000
page 4 of 9 Homestead Inc.
OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM FORM
PART C: SYSTEM INFORMATION
Property Address: 574 Haydenville Road, Northampton, MA
Owner: John Zak, Executor
Date of Inspection: 8/6/03
RESIDENTIAL
FLOW CONDITIONS
DESIGN flow based on 310 CMR 15.203 (gallons/day)
Number of bedrooms(design)
Number of bedrooms(actual)
Number of current residents
Is there a garbage grinder?(Y or N) _
Is there a Laundry Hookup?(Y or N)
Is the Laundry a separate system?(Y or N) (If yes, separate inspection required)
Seasonal use (Y or N)
Water meter readings, if available(last two years usage) (gallons per day)
Sump Pump(Y or N)_
Date of last occupancy_
COMMERCIAL/INDUSTRIAL
Type of establishment: welding shop
Design flow (based on 310 CMR 15.203): 60 gpd
Basis of design flow (seats/persons/sqft, etc.): 15 gallons Der person, 4 people ( ? )
Grease trap present(yes or no): no
Industrail waste holding tank present(yes or no): no
Water meter readings, if available: N/A
Last date of occupancy/use: about 60 days
OTHER(describe):
GENERAL INFORMATION
Pumping Records
Source of information: No information
Was system pumped as part of the inspection (Y or N)
If yes,volume pumped: gallons --How was quantity pumped determined?
Reason for pumping:
Comment:
TYPE OF SYSTEM:
X Septic tank, distribution box, soil adsorption system.
Single cesspool
Overflow cesspool
Privy
N Shared system (Y or N) (if yes, attach previous inspection records, if any)
Innovative/Altemative technology. Attach copy of the current operation and maintenance contract(to
be obtained from system owner)
Tight tank(Attach a copy of the DEP approval)
Other(describe):
N Were sewage odors detected when arriving at the site(Y or N)
Title 5 Inspection Form 6/15/2000
page 5 of 9 Homestead Inc.
OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM FORM
PART C:
SYSTEM INFORMATION(continued)
Property Address: 574 Havdenville Road Northampton, MA
Owner: John Zak, Executor
Date of Inspection: 8/6/03
APPROXIMATE AGE All components, date installed, and source of information
Septic plan: estimated to be 1984 systet
Source of Information Board of Health
BUILDING SEWER (located on site plan)
20 Depth below grade (inches) estimated Average
20 Distance in feet from private water supply well or suction line
cast iron Materials of Construction
Comments:
SEPTIC TANK (located on site plan)
Concrete Materials of Construction
20 Depth below grade (inches)
O Riser depth (inches)
56 Septic tank width (inches)
100 Septic tank length (inches)
57 Septic tank height (inches)
1,385 Calculated gross volume (gallons calculated
11 Air space in tank (inches)
1,100 Net Volume (gallons Calcul ated
29 Baffle depth (inches)
8 Sludge thickness (inches) Average
O Scum thickness (inches) Average
20 Top Sludge : Bottom Baffle (inches) calculated
18 Bottom Scum : Bottom Baffle (inches) cat cut atea
9 Top Scum : Top Baffle (inches) calculated
Comments:
Tank appears OK.
Recommendations:
PUMP CHAMBER
N Pump part of septic system: (Y or N)
Pumps in working order: (Y or N)
Alarms in working order: (Y or N)
Comments:
Tide 5 Inspection Form 6/15/2000
page 6 of 9
Homestead Inc.
OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM FORM
PART C:
SYSTEM INFORMATION(continued)
Property Address: 574 Haydenville Road Northampton MA
Owner: John Zak, Executor
Date of Inspection: 8/6/03
[ISTRIBUTION BOX (located on site plan) (°D-box")
D-box part of septic system: (Y or N)
Depth of liquid level above outlet invert
Some debris removed (old shirt) , but otherwise clean.
0
Comments:
Round d-box.
SOIL ADSORPTION SYSTEM (SAS): Technology Used (located on site plan by estimate):
leaching pits & number:
leaching chambers and number:
leaching galleries and number:
leaching trenches, number, length:
Y leaching fields, number, dimensions: estimated at 20• x 32'
overflow cesspool, number:
innovative/alternative system,Type:
Comments: (note soil conditions, signs of hydraulic failure, level of ponding, condition of vegetation, etc.)
No problems seen on surface.
If SAS not located
explain why:
TIGHT OR HOLDING TANK (tank must be pumped
N Tight tank part of system: (Y or N)
Depth below grade (inches)
Tank width (inches)
Tank length (inches)
Tank height (inches)
Calculated gross volume (gallons
Materials of construction
Design flow: gallons/day
Pumps in working order: (Y or N)
Alarms in working order: (Y or N)
Date of last pumping
Comments: (conditions of inlet tees, condition of alarm and float switches, etc.)
at time of inspection)
Measured
From Plan
From Plan
From Plan
Calculated
PRIVY
N
Comments:
(locate on site plan,if any)
Privy part of system: (Y or N.
Materials of construction:
Dimensions:
Depth of solids:
(soil conditions, signs of hydraulic failure, level of ponding, cond
ion of vegetation, et(
Title 5 Inspection Form 6/15/2000
page 7 of 9
Homestead Inc.
OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM FORM
PART C:
SYSTEM INFORMATION(continued)
Property Address: 574 Haydenville Road Northampton, MA
Owner: John Zak, Executor
Date of Inspection: 8/6/03
CESSPOOLS (cesspool must be pumped as part of inspection)
N Cesspool part of system: (Y or N)
Number and configuration:
Depth-top of liquid to inlet invert
Depth of solids layer
Depth of scum layer
Dimensions of cesspool
Materials of construction
Indication of groundwater inflow(cesspool must be pumped as part of inspection)
Comments: (note soil conditions, signs of hydraulic failure, level of ponding, condition of vegetation
GREASE TRAP (Usually present in certain commercial systems)
N Grease Trap part of system: (Y or N)
Materials of construction:
Depth below grade (inches) Measured
Dimensions:
Depth of solids layer
Depth of scum layer
Top of scum to top outlet calculated Inched
Date of last pumping
Bottom of scum to outlet. calculated Inches
Scum thickness (inches) 8veraae
Comments: (recommendation and conditions)
SITE EXAM (Source of Information)
Slope
Surface water
Check Cellar
Shallow wells
>48 Estimated depth to ground water (inches)
Please indicate(check) all the methods used to determine high groundwater elevation:
Obtained from system design plan on record
Date of design plan reviewed
Y Observed site (abutting property/observation hole within 150 feet of SAS)
Y Checked with local Board of Health-explain:
(Information: Information based on 1983 perc test.
Title 5 Inspection Fonn 6(15/2000
page 8 of 9
Homestead Inc.
Note: No known drinking water sources within 100' radius.
Outline of building
\b
ti
(0
Field, approximate layout coo ,
septic tank
1111111111 m 11 ili 1m [:� 59'
Distribution box ®�3g 1/2'
North
COMMENTS:
Recommend pumping on a 3 to 5 year schedule. Also, a cony of this plan posted in the
basement/utility area would keep this information accessible in future years for maintenance.
As-Built Drawing Date: Owner: HOMESTEAD INC.
Existing Septic System $/6/03 John Zak, Executor Thomas S. Leue R.S.
574 Haydenville Roa. 1664 Ca se
Scale: 1 : 20' Revision Date:
Florence, MA 01062 / / Williamsburg,1413]6 MA 01096
Except as Noted yg 14131628-4533