Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
29-084 (3)
I 1 ACREBROOK DR BP-2016-1181 GIs#: COMMONWEALTH OF MASSACHUSETTS Map-Block:29-084 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) CateUorv: SOLAR PANELS BUILDING PERMIT Permit# BP-2016-1181 Project# JS-2016-002033 Est. Cost: $10000.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: SOLARCITY CORP 107663 Lot Size(sq. ft.): 12980.88 Owner: JENNISON KIMBERLY Zoning: Applicant: SOLARC'ITY CORP AT. 11 ACREBROQK DR Applicant Address: Phone: Insurance: 604 SILVER ST (978)215-2369 (1 Workers Compensation AGAWAMMA01001 ISSUED ON:4/13/2016 0:00:00 TO PERFORM THE FOLLOWING WORK:INSTALLROOF MOUNTED 3.9 KW SOLAR ARRAY POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy §ignature: FeeType: Date Paid: Amount: Building 4/13/2016 0:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner File#BP-2016-1181 APPLICANT/CONTACT PERSON SOLARCITY CORP ADDRESS/PHONE 604 SILVER ST AGAWAM01001 (9'X8)215-2369() PROPERTY LOCATION 11 ACREBROOK DR MAP 29 PARCEL 084 001 ZONE THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out - Fee Paid Typeof Construction: INSTALLROOF MOUNTED 3.9 KW$OLAR ARRAY New Construction Non Structural interior renovations Addition to Existing Accessory Structure - Building Plans Included• Owner/Statement or License 107663 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFO ATION PRESENTED: pproved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR _ Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street CommissionPermit DPW Storm Water Management Demolition Delay kip. ure of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of Planning&Development for more information. �� Rte•^ - Department Use only :,Ditsr '1190m on Statue f P trnit .. Building Dep rtm nt btAriveway Permit APR �82AMn tre Sewo � k abillty� Room 1 0 Water/ ellAvailabl A 0 060 Twa 5 ��r-0 Plans 3-587-1272 Plo 6tol r'Plan' Other Specify.. APPLICATION TO CONSTRUCT,ALTER,REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office 11 Acrebrook Dr Map Lot unit Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Kimberly Jennison 11 Acrebrook Dr,Florence MA 01062 Name(Print) Current Mailing Address: 413-330-3274 Telephone Signature 2.2 Authorized Agent: SolarCity CorpNictoria Junck 604 Silver St Agawam MA 01001 Name(Prin Current Mailing Address: 978-215-2367 Si ature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building 3,000 (a)Building Permit Fee 2. Electrical (b)Estimated Total Cost of 7,000 Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical (HVAC) 5. Fire Protection 6. Total=0 +2+3-+4+5) 10,000 1 Check Number 117 41 /5 This Section For qfficial Use Only Building Permit Number: bate Issued: Signature: Building Commissioner/Inspector of Buildings Date �� K P Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to befilled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage % Open Space Footage % (Lot area minus bldg&paved parking) #of Parking Spaces Fill: volume&Location A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO DON'T KNOW YES IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO DON'T KNOW YES IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained , Date Issued: C. Do any signs exist on the property? YES NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing, grading, excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES NO IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House Addition Replacement Windows Alterations) Roofing Or Doors Accessory Bldg. Demolition New Signs '[ ] Decks [ j Siding[ ] Other r7 Brief Description of Proposed Work: Install solar electric panels to roof of existing home to be interconnected with home's electrical system Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a. If New and or addition to existinca housing.�omplete the following: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Kimberly Jennison as Owner of the subject property hereby authorize SOLARCITY to act on my behalf, in all matters relative to work authorized by this building permit application. 04/07/2016 Signature of Owner Date SOLARCITY CORPNICTORIA JUNCK as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. SOLARCITY CORPNICTORIA JUNCK Print Name 04/07/2016 Sign re o er/Agent Date SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Hoiden:SOLARCITY/CRAIG ELLS 107663 License Number 604 SILVER ST AGAWAM MA 01001 8/29/17 Address Expiration Date 0- " t. 978-875-1698 0 Signature Telephone 9 Registered Borne Improvement Contractor Not Applicable ❑ SOLARCITY CORP/VICTORIA JUNCK 168572 Company Name Registration Number 604 SILVER ST AGAWAM MA 01001 03/08/2017 Address Expiration Date elephone 978-215-2367 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... ❑ No...... ❑ 11 - Nome Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780 Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature The Commonwealth of Massachusetts xr�, ,Department of IndustrialAceidents Y Office of Investigations I Congress Street,Suite 100 7�'r Boston,MA 02114-2017 tvlvw.mossgovIdia Workers'Compensation Insurance Affidavit:Builders/Contractors/Clectriciansf.plu tubers Applicant nfarm tion Please Print Le ibl Namc(Busineworganizationlindividual): SO1..ARCITY CORP Address:3455 CLEARVIEW WAY City/State/Zip:SAN MATEO,CA 94402 Pltotte#:888-765-2489 Are you an employer?Check Ute appropriate box: Type of project(required): 1.9 I am a employer with 5000 4. ❑ 1 am a general contractor and i ctrlployces(full and/or part-time), have hired)the sub-contractors 6. New Jelin rcrion 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑Remodeling ship and have no employees These sub-contractors have 8. 0 Demol9tion workingfor me in an capacity. employees and have workers' Y9. [}Building addition [No workers'comp.insurance comp.insurance.; re uired. S. We are a corporation and its 10.❑Electrical repairs or additions q officers have exercised ter I I.❑Plumbing 3.❑ I stn a homeowner doing ail work t;repairs or additions myself [No workers' comp. right of exemption per MG1.. 12_[]Roof repairs insurance required.]t c. 152,§1(4),and we have no SOLAR 1 PV employees.[No workers' 13.®Other comp.insurance required.] Any applicant that checks box#1 must also fill Dill the section Ildmi!shotving their workers'compensation policy information. t/Homeowners who submit this affidavit indicating iltey are doing all wwk and then hire outside contraOlors must submit a new affidavit indicating such. fConlractors that check this box must atisehed an additional sheet shawhrg tim narne al'the sub-contractors and state whether or not those entities have employees. Irthesub-contractors have amployess,litcy must provide their work-crs'comp.policy number, I ant an employer float is providing workers'conipensalior►insurance for my emproyem. Below fs the policy and Jab site Information. Insunrice Company Name, Zurich American Insurance Company Policy it or Self-ins. Lie. th WC0182014-00_ � Expiration[late: 09/01/2016 Job Site Address: I Ia o' n o c 0- . City/slate/zip: ft- Attach a copy of lite workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL e, 152 can lead to lite imposition of criminal penalties of a fine up to 51,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under Ike pains and panoldes of perJerrli 11#41 the hi formrafiust provider!)above is true/and correct. S' naturg: �-�'`- ��" [ .:_.... ._ l)atr " o-7/1 lX Phone H; Official use orriy. Do not write in 11tis area,to 6e completed by city or town official. City or Town: PermittLicense# Issuing Authority(circle one): 1. is orHealth 2.Building Department 3.City/Towp Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: 7 ® DATE(MMODNYYY) A40 RU CERTIFICATE OF LIABILITY INSURANCE F0811712015 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER,THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such andarsement(s). CONTACT PRODUCER _NAME;. MARSH RISK&INSURANCE SERVICES PHONE FAx 345 CALIFORNIA STREET,SUITE 13DO (AIC HQ-Ext)L ....... ..liArc No1_.- CALIFORNIA LICENSE NO.0437153 E-MALL SAN FRANCISCO,CA 94104 DRESS_ Attn:Shannon Scott 415-743.8334 tNsv_RE�S)AFFORDING COVERAGE.___. __ NAtc _ - S98301_STND-GAWUE-15-16 _ INSURER A:Zurich American insurance Company 1 _.-.. NIA INSURED INSURER 5:NIA +... SolarCity Corporation 3055 Clealview Way INSURER C:NIA NIA San Mateo,CA 94402 INSURER D.__American Zurich insurance Company 40142 ENSURERU,,. _.... -._ ___ . ........ .__... {._. .. INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-002713836.08 REVISION NUMBER:4 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE - ADDC SUER POLICY NUMBER —� PONIfuODY/YYYY�MFO!l ODNYYYY�—— — LIMITS LTR A IX !COMMERCIAL GENERAL LIABILITY �GL00182016-00 098)12015 �091Q112016 EACHOCCURRENCE S 3.000,000 jx —.— CLAWS-MADE1OCCUR I i PR�14!SlSs(Eaoccurrence) .,.. . .. ..3000,000 SIR:$250,000 i MED EXP(Any o person)._- S.._ 5,000 _.. I PERSONAL&ADVINJURY 5 3,000,000 i GEN'L AGGREGATE LIMIT APPLIES PER f GENERAL AGGREGATE $ 6 000,000 _. X POLICY ]PRO j (LOC }PRODUCTS COMPIRPAGG,+S 6000000 OTHER: I is A kUTOMOBILELIABCOMBINED SINGLE LIMIT iBAPa182017.00 091012015 1098)12016 5 .,._. 500,000 X .I ANY AUTO BODILY INJURY(Per person) $ : I X'ALL OVBdED X SCHEDULED BODILY INJURY(Per accident) S 'AUTOS ._._ AUTOS j i ._... .. .. .... ......... NON-OWNED PROPERTYOAMAGE S HIREDAUTOS .x-, AUTOS -LPer acatlenl.................. COMPICOLL DED: S $5,000 UMBRELLA LIAO I OCCUR ! i EACH OCCURRENCE S IIII _. EXCESS LIARAGGR ,CLAIMS-MAOEI : EGATE T6, TT -...... _. .._ ...... DED I I RETENTIONS I S Q WORKERS COMPENSATION WC0182014.ap(AOS) 09,012015 0910112016 X STATUTE RH AND EMPLOYERS'LIABILITY YIN IWC0182015-a0 MA 0981112015 09101/2016t 1000 ODO A ANY PROPMETORIPAR7NERIEXECunvE ❑ ( E L EACH ACCIDENT 5 OFFICERlMEMSEA EXCLUDED? IMandatary In NH) N N 7 A IWC DEDUCTIBLE:$500,000 t E L.DISEASE. EA EMPLOYE S l ODD DDD Iryyes,tlescnhe under j E_L.DISEASE•POLICY LIMIT $ 1,000,000 IDESCRiPTION OF OPERATIONS balaw 1 DESCRIPTION OF OPERATIONS f LOCATIONS I VEHICLES(ACORD 1121,Additional Remarks Schedule,may be attached K more space Is requiredl Evidence of insurance. CERTIFICATE HOLDER CANCELLATION SolarCily Corporation SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 3055 Clearview Way THE EXPIRATION DATE THEREOF, NOTICE MOLL BE DELIVERED IN San Mateo.CA 99402 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh Risk&Insurance Services Ctlarles Martnolejo -- i 01988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2D14101) The ACORD name and logo are registered marks of ACORD DocuSign Envelope ID:OD1000D8-236D-49E3-A17B-F1364DC05159 SolarCity IPPA i Customer Name and Address Installation Location Date Kimberly Jennison 11 Acrebrook Dr 3/23/2016 11 Acrebrook Dr Florence,MA 01062 Florence,MA 01062 Here are the key terms of your Power Purchase eeme t: I'L 3 7`0 2 =myrs System installation cost Electricityratsr kWh' Agreement Term Initial h�re Initial here The SolarCity Promise °S •We guarantee that if you sell your Home,the buyer will qualify to assume your Agreement. .... _. ..___.. Initial here •We warrant all of our roofing work. •We restore your roof at the end of the Agreement. •We warrant, insure, maintain and repair the System. . .. _........ initial her,.[: •We fix or pay for any damage we may cause to your property. •We provide 24/7 web-enabled monitoring at no additional cost. •The rate you pay us will never increase by more than 2.90%per year. •The pricing in this Agreement is valid for 30 days after 3/23/2016. Your SolarCity Power Purchase Agreement Details Your Choices at the End of the Initial Options for System Purchase: Amount due at contract signing Term: •At certain times,as specified in $0 •SolarCity will remove the System at no the Agreement,you may Est':amount due at installation cost to you. purchase the System. $0 •You can upgrade to a new System with •These options apply during the 20 the latest solar technology under a new year term of our Agreement and Est.amount due at building inspection $O contract. not beyond that term. •You may purchase the System from Est.first year production SolarCity for its fair market value as 4,155 kWh specified in the Agreement. .You may renew this Agreement for up to ten(10)years in two(2)five(5)year increments. 3055 CI earvi ew Way, San Mateo,©, CA 94402 888.755.2489 solarcity.com 16$6252 Power Purchase Agreement,version 9.1.1,February 15,2016 SAPC/SEFA Compliant Contractors License MA HIC 168572/EL-1136MR Document generated on 3/23/2016 Copyright 2008-2015 SolarCity Corporation,All Rights Reserved DocuSign Envelope ID:OD1000D8-23BD-49E3-A17B-F1364DC05159 23. NOTICE OF RIGHT TO CANCEL. I have read this Power Purchase Agreement and the Exhibits in YOU MAY CANCEL THIS CONTRACT AT ANYTIME PRIOR their entirety and I acknowledge that I have received a TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE complete copy of this Power Purchase Agreement. DATE YOU SIGN THIS CONTRACT.: SEE EXHIBIT 1,THE ATTACHED NOTICE OF CANCELLATION FORM FOR AN Customer's Name: Kimberly Jennison EXPLANATION OF THIS RIGHT. L6.,ky� usigMsa by: 24. ADDITIONAL RIGHTS TO CANCEL Signature: h S81n. IN ADDITION TO ANY RIGHTS YOU MAY HAVE TO CANCEL . �J Wbf— THIS PPA UNDER SECTION 23,YOU MAY ALSO CANCEL THIS PPA AT NO COST AT ANY TIME PRIOR TO Date: 3/23/2016 COMMENCEMENT OF CONSTRUCTION ON YOUR HOME. 25. Pricing The pricing in this PPA is valid for 30 days after 3/23/2016. Customer's Name: If you don't sign this PPA and return it to us on or prior to 30 days after 3/23/2016,SolarCity reserves the right to reject this PPA unless you agree to our then current pricing. Signature: Date: Power Purchase Agreement SolarCit approved Signature: Lyndon Rive, CEO Date: 3/23/2016 r 1 �� � Version#55.3-TBD = _ SolarCity, April 6, 2016 RE: CERTIFICATION LETTER Project/Job # 0102036 Project Address: Jennison Residence 11 Acrebrook Drive Northampton, MA 01062 AH] Northampton SC Office Springfield Design Criteria: -Applicable Codes = MA Res. Code, 8th Edition,ASCE 7-05, and 2005 NDS - Risk Category = II -Wind Speed = 90 mph, Exposure Category C -Ground Snow Load =40 psf - MPI: Roof DL = 10 psf, Roof LL/SL = 28 psf(Non-PV Areas), Roof LL/SL = 28 psf(PV Areas) - MP2: Roof DL = 10 psf, Roof LL/SL = 28 psf(Non-PV Areas), Roof LL/SL = 28 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.22424 < 0.4g and Seismic Design Category(SDC) = B < D To Whom It May Concern, A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from SolarCity. Structural evaluation was based on site observations and the design Criteria listed above. Based on this evaluation, I certify that the existing structure directly supporting the PV system is adequate to withstand all loading indicated in the design criteria above based on the requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval. 2� K. Sincerely, Digitally signed by Humphrey z RIUKI v ST UCTURAL N Humphrey Kariuki, P.E. Ka rl u kl NO.s1933 Professional Engineer GISTEa�� T: 443.451.3515 Date: 2016.04.06 22:08:11 -04'00' ss�ava. email: hkariuki@solarcity.com "teal :. Way `an Kjt r" i- 04'10, 0; nZ.R 1028 t8M"Ol. Version#55.3-TBD SolarCity. . HARDWARE DESIGN AND STRUCTURAL ANALYSIS RESULTS SUMMARY TABLES Landscape Hardware-Landscape Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MPi 64" 24" 39" NA Staggered 44.8% M132 64" 24" 39" NA Staggered 44.9% Portrait Hardware-Portrait Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MPi 48" 17" 65" NA Staggered 55.9% MP2 48" 18" 65" NA Staggered 56.0% Mounting Plane Framing Qualification Results Structure Type Spacing Pitch Member Evaluation Results MPI Stick Frame @ 16 in.O.C. 220 Member Analysis OK MP2 Stick Frame @ 16 in.O.C. 24° Member Analysis OK Refer to the submitted drawings for details of information collected during a site survey. All member analysis and/or evaluation is based on framing information gathered on site.The existing gravity and lateral load carrying members were evaluated in accordance with the IBC and the IEBC. STRUCTURE ANALYSIS - LOADING SUMMARI AND MEMBER CHECK - MP1 Member Pro rties Summary MPl 0 `zontal Member' ns Rafter Pro es j;rnal ng 0.32 ft Actual W 1.50" Roof stem Pro rt-es, 10.45 ft Actual D 5.50" Number of Spans w/o Overhang) 1 Span 2 Nominal Yes Roofing Material Camp RoofSp n 3 A 8.25 in.^2 Re-Roof No Span 4 S. 7.56 in.^3 Plywood Sheathin Yes Spin 5 1 1 20.80 in.^4 Board Sheathing None Total R ke Span 1 11.62 ft TL DefPn Limit 120 Vaulted Ceiling Na PV 11 Start 3.75 ft Wood Species SPF Ceiling Finish 1/2"Gypsum Board PV I End 10.00 ft Wood Grade #2 Rafter Slope 220 PV 2 Start Fb 875 psi Rafter Spacing 16"O.C. PV End F„ 135 psi Top Lat Bracing Full PV 31 Start I E 1400000 si Bot Lat Bracing At Supports PV 3 End I I Emin 510000 psi Member Loa4ing Summary Roof Pitch 5/12 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 10.0 psf x 1.08 10.8 psf 10.8 psf PV Dead Load PV-DL 3.0 psf x 1.08 3.2 psf Roof Live Load RLL 20.0 psf x 0.95 19.0 psf Live/Snow Load LL SL"z 40.0 psf x 0.7 1 x 0.7 28.0 psf 28.0 psf Total Load Governin LC TL 38.8 psf 42.0 DSf Notes: 1. ps= Cs*pf; Cs-roof, Cs-pv per ASCE 7[Figure 7-21 2. pf= 0,7(Cj(Cj(Ij p9; Ce=0.9,Ct=1.1, I5=1.0 Member sign S` mma (per NDS Governin Load Comb CD CL` + CL CF Cr D+S 1.15 1. 0 0.63 1.3 1.15 Member Analysis esults Summary Governing Analysis Max Demand 0 L tion Capacity DCR Result Bending + Stress 1190 psi 5.0 ft 1 1504 psi 1 0.79 Pass CALCULATION OF DESIGN WIND LOADS - MPI Mounting Plane Information Roofing Material Comp Roof PV System Type SolarCity SleekMountTm Spanning Vents No Standoff ..Attachment Hardware Comp Mount Type C Roof Slope 22°16"O.C. Rafter Spacing Framing Type/ Direction Y-Y Rafters NA X-X Purlins Only Purlin Spacing Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only NA ,Standing Seam/Trap Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 90 mph Fig. 6-1 Exposure Category C Section 6.5.6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height h 25 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.95 Table 6-3 Topographic Factor Krt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 16.7 psf Wind Pressure Ext. Pressure Coefficient(Up) GC (up) -0.88 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down G Dow„ 0.45 Fig.6-11B/C/D-14A/B Design Wind Pressure p p = qh (GC ) Equation 6-22 Wind Pressure Up p„ -14.6 psf Wind Pressure Down 10.0 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 64" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 17 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -224 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 44.8% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever Portrait 17" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -280 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 55.9% STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK - MP2 Member PropIntal es Summary MP2 Ho Member Spans Rafter Properties Overhang 0.32 ft Actual W 1.50" Roof System Pro es S n 1 11.05 ft Actual D 5.50" Number of Spans w/o Overhang) 1 Span 2 Nominal Yes Roofing Material Comp Roof §p#n 3 A 8.25 in.^2 Re-Roof No Span 4 SX 7.56 in.^3 Plywood Sheathing Yes S n 5 I 20.80 in.^4 Board Sheathing None Total R ke Span 12.45 ft TL DefTn Limit 120 Vaulted Ceiling No PV 11 Start 4.58 ft Wood Species SPF Ceilino Finish 1/2"Gypsum Board PV I End 1 10.75 ft Wood Grade #2 Rafter Slope 240 PV 2 Start Fb 875 psi Rafter Spacing 16"O.C. PV2 End I F„ 135 psi Top Lat Bracing Full PV 3 Start E 1400000 psi Bot Lat Bracing At Supports PV 3 End Emig 510000 psi Member Loa ing mary Roof Pitch 6/12 In ial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 10.Q psf x 1.09 10.9 psf 10.9 psf PV Dead Load PV-DL 3.0 psf x 1.09 3.3 psf Roof Live Load RLL 20.Q psf x 0.93 18.5 psf Live/Snow Load LL SLi1Z 40.1 psf x 0.7 x 0.7 28.0 psf 28.0 psf Total Load(Governing LC I TL 1 38.9 psf 42.2 DO Notes: 1. ps = Cs*pf; Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0 7(Ce)(Ct)(IS)pg; Ce=0.9,Ct=1.1, I5=1.0 Member Desi n S mma r NDS Governing Load Comb CD CL + CL - CF Cr D+ S 1.15 1. 0 0.60 1 1.3 1.15 Member Analysis Results Summary Governing Analysis Max Demand 1 0 Lo ation Capacity DCR Result Bending + Stress 1328 psi 5.9 ft 1504 psi 0.88 Pass CALCULATION OF DESIGN WIND LOADS - MP2 Mounting Plane Information ` Roofing Material Comp Roof PV System Type SolarCity SleekMountTm Spanning Vents No Standoff Attachment Hardware Comp Mount Type C Roof Slope 240 Rafter Spacing 16"O.C. Framing Type/ Direction Y-Y Rafters Purlin Spacing X-X Purlins Only NA Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only NA ,Standing Seam/Trap Spacing SM Seam Only NA Wind Desian Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 90 mph Fig. 6-1 Exposure Category C Section 6.5.6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height h 25 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure K, 0.95 Table 6-3 Topographic Factor Krt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 qh = 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 Velocity Pressure qh 16.7 psf Wind Pressure Ext. Pressure Coefficient(U ) GC,(up -0.88 Fig.6-11B/C/D-14A/B Ext.Pressure Coefficient(Down) GC Down 0.45 Fig.6-11B/C/D-14A/B Design Wind Pressure p p = qh (GC ) Equation 6-22 Wind Pressure Up p„ -14.6 psf Wind Pressure Down down 10.0 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 64" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 17 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -225 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand Ca aci DCR 44.9% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever Portrait 18" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -280 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR, 56.0% ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A� AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GECGALVANIZED ELECTRODE CONDUCTOR HAZARDS. EACHEUNGROUND690.17. UNGROUNDED CONDUCTOR OF THE CITY OF NORTHAMPTON GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY BUILDING DEPARTMENT HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. 1 CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(6). These plans have been reviewed Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER And app kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR roved. kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN Date (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE S i g n atu r PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL OPS UNNTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINIIGHT PV1 COVER SHEET PV2 PROPERTY PLAN PV3 SITE PLAN PV4 STRUCTURAL VIEWS UPLIFT LICENSE GENERAL NOTES PV6 THREE LINECULATIONS DIAGRAM GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION Cutsheets Attached ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: AHJ: Northampton REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: National Grid USA (Massachusetts Electric) PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: — \ CONTAINED SHALL NOT BE USED FOR THE JB 0102036 00 KIMBERLY JENNISON Cod Whitinga ' Kimberly Jennison RESIDENCE Y e son E v BENEFIT OF ANYONE EXCEPT SOLARCITY INC., 71 �•.,� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ACREBROOK DRIVE i ,SolarCit • Com Mount Type C 11 3.9 KW PV ARRAY � Y PART TO OTHERS OUTSIDE THE RECIPIENT'S P YP ORGANIZATION, EXCEPT IN CONNECTION 1MTH MODULES NORTHAMPTON, M A 01062 24 St. Martin Drive, Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (15) TRINA SOLAR # TSM-260PDO5.18 PAGE NAME: SHEET. REV: DAIS Marlborouc , MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T. (650)638-1028 F: (617 638-1029 PERMISSION of SOLARCITY INC. SOLAREDGE SE3800A—USOOOSNR2 COVER SHEET PV 1 4/6/2016 (BBB)—SOL-CITY(765-2489) www.sdarcitycom PROPERTY PLAN Scale:l" = 20'-0' _ 0 20' 40' 3 JB010 2 0 3 6 O O PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: CONTAINED SHALL NOT BE USED FOR THE KIMBERLY JENNISON Kimberly Jennison RESIDENCE Cody Whiting � SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: w'.` NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 11 ACREBROOK DRIVE 3.9 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: NORTHAMPTON MA 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Martin Drive, Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (15) TRINA SOLAR # TSM-260PDO5.18 SHEET: REV: DATE Marlborough, MA 01752 SONRCITY E4JIPMENT, WITHOUT THE WRITTEN PAGE NAME T: (650) 638-1026 F: (650)638-1029 PERMISSION+.:.�F SOLARCITY INC. INVERTER: PROPERTY PLAN PV 2 4/6/2016 (666)—SOL—CITY(765-2469) www.solarcity.com SOLAREDGE SE380OA—USOOOSNR2 PITCH: 22 ARRAY PITCH:22 +' MP1 AZIMUTH:70 ARRAY AZIMUTH:70 P F!� MATERIAL:Comp Shingle STORY: 2 Stories PITCH: 24 ARRAY PITCH:24 02 K. MP2 AZIMUTH:250 ARRAY AZIMUTH: 250 Z R1 KI MATERIAL: Comp Shingle STORY: 2 Stories v ST UCTURAL No.51933 GIs Front SS�ONA1.. Front Of House STAMPED & SIGNED Digitally signed by Humphrey Kariuki Date: 2016.04.06 A 22:07:41 -04'00' LEGEND (E) UTILITY METER & WARNING LABEL Inv FG INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS Dc DC DISCONNECT & WARNING LABELS AC Tdkl © AC DISCONNECT & WARNING LABELS O DC JUNCTION/COMBINER BOX & LABELS ---- �D DISTRIBUTION PANEL & LABELS AC ,,,- U P2 ' r�=-1 LG LOAD CENTER & WARNING LABELS or� D \1 O DEDICATED PV SYSTEM METER STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR B CONDUIT RUN ON INTERIOR — GATE/FENCE O HEAT PRODUCING VENTS ARE RED r,�-1 1k 11 INTERIOR EQUIPMENT IS DASHED L-'J SITE PLAN Scale: 1/8" = 1' a 01' 8' 16' �co 1 011110 3 CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: JB-0102036 00 CONTAINED SHALL NOT BE USED FOR THE KIMBERLY JENNISON Kimberly Jennison RESIDENCE Cody Whiting BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: � NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 11 ACREBROOK DRIVE 3.9 KW PV ARRAY i�solarCity. PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES NORTHAMPTON M A 0106 2 ORGANIZATION, EXCEPT IN CONNECTION HATH 24 St. Martin Drive, Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (15) TRINA SOLAR # TSM-260PD05.18 PAGE NAME SHEET: REV. DATE Marlborough, MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T: (650)638-1026 F. (617 638-1029 PERMISSION of sotARaTY INC. SOLAREDGE # SE3800A-USOOOSNR2 SITE PLAN PV 3 4/6/2016 (888)—SOL—CITY(765-2489) www.solarcity.com S1 S1 4" 10'-10" (E) LBW (E) LBW SIDE VIEW OF MP2 NTS SIDE VIEW OF MP1 NTS B A MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MIDI X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 64" 24" STAGGERED LANDSCAPE 64" 24" STAGGERED PORTRAIT 4811 18" PORTRAIT 48" 1711 RAFTER 2X6 @ 16" OC ROOF AZI 250 PITCH 24 STORIES: 2 RAFTER 2x6 @ 16 OC ROOF AZI 70 PITCH 22 STORIES: 2 ARRAY AZI 250 PITCH 24 ARRAY AZI 70 PITCH 22 C.J. 2x6 @16" OC Comp Shingle C.J. 2X6 @16" OC Comp Shingle PV MODULE IF 5/16 BOLT WITH INSTALLATION ORDER FENDER WASHERS �° K. LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT 0 S1 ucTu33 HOLE. No.,51933 ZEP ARRAY SKIRT (6) �0 'F 00r SEAL PILOT HOLE WITH c�sTE (4) (2) POLYURETHANE SEALANT. SS�p�� ti ZEP COMP MOUNT C _ — ZEP FLASHING C (3) (3) INSERT FLASHING. �°A M f'I '- & S I G P E Cr (E) COMP. SHINGLE (4) PLACE MOUNT. (E) ROOF DECKING (2) INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH WITH SEALING WASHER (6) BOLT & WASHERS. (2-1/2" EMBED, MIN) (E) RAFTER STANDOFF CONFIDENTIAL— THE INFORMATION HEREIN NUMBER: JB-0102036 0 0 PREMISE ONNER: DESCRIPTION: DESIGN: JOB CONTAINED SHALL NOT BE USED FOR THE KIMBERLY JENNISON Kimberly Jennison RESIDENCE Cody Whiting ty BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 11 ACREBROOK DRIVE 3.9 KW PV ARRAY ,SolarCi PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: NORTHAMPTON MA 01062 ORGANIZATION, SALE AND USEEPT OF INCONNECTION RESP RESPECTIVE TRINA SOLAR TSM-260PD05.18 ' 24 St. Martin Drive Building unit it THE (15) � E S PAGE NAME- REV: DATE Marlborough, MA 017522 SOVRCITY EQUIPMENT, WTHOUT THE WRITTEN INVERTER: T: (650)638-1028 F. (650)638-1029 PERMISSION SOLARCITY INC. SOLAREDGE SE3800A—USOOOSNR2 STRUCTURAL VIEWS PV 4 4/6/2016 (888)—SOL—CITY(765-2489) www.solarcity.com + UPLIFT CALCULATIONS SEE SEPARATE PACKET FOR STRUCTURAL CALCULATIONS. CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: JB-0102036 00 CONTAINED SHALL NOT BE USED FOR THE KIMBERLY JENNISON Kimberly Jennison RESIDENCE Cody Whiting • BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM:WH .j;,SOIarCIty. NOR SHALL IT BE DISCLOSED IN OLE OR IN Comp Mount Type C 11 ACREBROOK DRIVE 3.9 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES. NORTHAMPTON M A 0106 2 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Martin Drive, Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (15) TRINA SOLAR # TSM-260PDO5.18 PAGE NAME SHEET: REV: DATE: Marlborough, MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T: (650) 638-1028 F: (650)638-1029 PERMISSION Of SOLARCITY INC. SOLAREDGE # SE380OA—USOOOSNR2 UPLIFT CALCULATIONS PV 5 4/6/2016 (888)-SCI-CITY(765-2489) www.solarcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number:LC204OB1100 Inv 1: DC Ungrounded INV 1 —(1)SOLAREDGE# SE380OA—USOOOSNR2 LABEL: A —(15)TRINA SOLAR TSM-260PDO5.18 GEN #168572 ODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:74567166 Tie—In: Supply Side Connection Inverter; 38o0W, 240V, 97.570. w/Unifed Disco and ZB,RGM,AFCI PV Module; OW, 236.9W PTC, 40MM, Black Frame, H4, ZEP, 1000V ELEC 1136 MR Underground Service Entrance INV 2 Voc: 38,2 Vpmax: 30.6 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 100A MAIN SERVICE PANEL E 100A/21P MAIN CIRCUIT BREAKER Inverter 1 (E) WIRING CUTLER—HAMMER Disconnect CUTLER—HAMMER 100A/2P 3 Disconnect 2 SOLAREDGE A 20A 13 SE380OA—USOOOSNR2 A L1 F270 6 L2 N 1 (E) LOADS GND _ ____ GND _—_____-___-_—___-------- - GEC TNDCL DC+ Dc. MP1,MP2: 1x15 r---_j GND __ EGC--------------------------------------- EGC-----------------tj I 4EGNCIGEC � I 1 I I I I - GEC TO 120/240V SINGLE PHASE 1 I I UTILITY SERVICE I I I I I I I I I I I PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP OI (2)Groy rAL Roo A (1)CUTLER—HAMMER #DG222NRO /�� PV (15)SOLAREDGE#P300-2NA4AZS D� 5 8 x 8, C per Disconnect; 60A, 24OVac, Fusible, NEMA 3R /� PowerBox ptlmizer, 30OW, H4, DC to DC, ZEP —(2)ILSCO #IPC 470—/6 1 CUTLER—HAMMER DG221UR6 (1)AWG #6, Solid Bare Copper Insulation Piercing Connector; Main 4/0-4, Tap 6-14 B ( ) n� Disconnect; 30A, 24OVac, Non—Fusible, NEMA 3R —(1)Ground Rod; 5/8" x 8', Copper SCSUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE _(0 CUTLER— AMMER N DG03ONB AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. Ground)Neutral Kit; 30A, General Duty(DG) I(N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL ;ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE 3 .......... __.__._._----_ -_ ....... . -- (1)AWG¢6, THWN-2, Black I AWG#10, THWN-2, Red Black I=L(�)AWG u t K d3 4 r _.. _ ..___ �_....... AWG (2) 60OV, Black Voc* =500 VDC Isc =15 ADC (1 AWG 16, THWN-2, Red O 3 ( ) #1 1 R #6 Copper EGC Vmp =350 VDC Imp=11 ADC Lr' (1)AWG /6, THWN-2, White NEUTRAL VmP =240 VAC Imp=16 AAC (11 AWG#10, THWN 2, White NEUTRAL Vmp =240 VAC Imp 16 AAC (.)Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -(i)AWG }6,.Solid Bare.Copper. GEC. . .—(1)Conduit.Kit;.3/4',EMT. . . . . . . , , .I . . . . . .-(1)AWG �8,.TFLWN-2,.Green . . EGC/GEC.-(1)Conduit.Kit;.3/4',EMT. . . . . . . . 1 I JB-0102036 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: \�\! ■ CONTAINED SHALL NOT BE USED FOR THE KIMBERLY JENNISON Kimberly Jennison RESIDENCE Cody Whiting ..;,,S��a�C�}" BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: w t.y® NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 11 ACREBROOK DRIVE 3.9 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: NORTHAMPTON MA 01062 ORGANIZATION, EXCEPT IN CONNECTION NTH 24 St. Martin Drive,Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (15) TRINA SOLAR # TSM-260PDO5.18 SHEET: REV: DATE Marlborough, MA 01752 SO�ARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: T: (650)638-1028 F. (650)638-1029 (R� INVERTER: PE MISSION of SOLARCITY INC. SOLAREDGE SE380OA—USOOOSNR2 THREE LINE DIAGRAM 4/6/2016 (888)—SOL—CITY(765-2489) www.solarcitycom CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 11 Acrebrook Drive UTILITY SERVICE AC r--� DISCONNECT L------------J AC I---------, DISCONNECT L---------J I -i INVERTER AND DC DISCONNECT ------------------------- SOLAR PHOTOVOLTAIC ARRAYS) i L--------------------------J PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN FAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V 3B-0102036-00 CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: PREMISE OyMER: DESCRIPTION: DESIGN: JB-0102036 00 CONTAINED SHALL NOT BE USED FOR THE KIMBERLY JENNISON KimberlyJennison RESIDENCE Cody Whiting SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 11 ACREBROOK DRIVE 3.9 KW PV ARRAY ►JA PART TO OTHERS OUTSIDE THE RECIPIENTS Moou�s NORTHAMPTON MA 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (15) TRINA SOLAR # TSM-260PD05.18 24 St. Matin Drive, Binding 2 unit t1 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE Marlborough, MA PERMISSION OF SOLARCITY INC. INVERTER: T. (650)636-1028 F. (6550)0) 638-1029 SOLAREDGE SE3800A—USOOOSNR2 SITE PLAN PLACARD PV 8 4/6/2016 (888)-sa—CITY(765-2489) www.sdarcity.cam WARNING:PHOTOVOLTAIC ROWER SOURCE Label Location: • .'• • .Label • • Code:Per WARNING ._ � WARNING -- r Code: NEC •'1 ELECTRIC SH�7CF HAZARJ3 690.17.ETHE DC CONDUOTORS OF THIS 690.35(F) USED WHEN DO NOTTL)I)CJ•J TERMINALS Label Location: TERMINALS(7N BOTH LIME AND PHOTOVOLTAIC SYSTEM ARE TO : LOAD SipES MAY BE ENERGZEp UNGROUNDED AND PHOTOVOLTAIC DC JN THE CIPEN POSJTJON'' MAY BE ENERGIZED ■UNGROUNDED NEC DISCONNECTPer Code: ••1 Label Label • • J'HOTOVOLTAIC POINT OF -• MAXIMUM POWER D INTERCONNECTION Per A WARNING: ELECTRIC SHOCK POINT CURRENT(Imp) Per Code: HAZARD. DO NOT TOUCH NEC 690.17.4; NEC 690.54 MAXIMUM POWER-� POINT VOLTAGE,(Vmp) VNEC 690.53 TERMINALS.TERMINALS ON BOTH THE LINE AND LOAD SIDE MAXIMUM SYSTEM V MAY BE ENERGIZED 1N THE OPEN VOLTAGE(Voc) POSITION FOR SERVICE SHORT-CIRCUIT- DE-ENERGIZE BOTH SOURCE CURRENT(Isc) A AND MAIN BREAKER.' PV POWER SOURCE. MAXIMUM AC A OPERATING CURRENT - MAXIMUM AC V Label Location: OPERATING VOLTAGE - WARNING Per ..- ELECTRIC SMOCK HAZARD 690.5(C) IF A GROUND FAULT IS INDICATED NORMALLY GROUNDEDLabel L• • CONDUCTORS MAY BE CAUTION ■ UNGROUNDED AND ENERGIZED DUAL POWER SOURCE Per ••- SECOND SOURCE IS NEC690.64.13.4 PHOTOVOLTAIC SYSTEM Label • • INARNN L N G T Location: ELECTRICAL SHOCK HAZARD 690.17(4) CAU 1 I ON DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE ANO Per Code: LOAD SIDES MAY BE ENERGIZED PHOTOVOLTAIC SYSTEM 690.64.B.4•1 • iN THE OPEN POSITION CIRCUIT IS BACKFEO DC VOLTAGE iS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT Label • • WARNING '• Per ..- INVERTER OUTPUT Label • - • CONNECTION NEC 690.64.B.7 Disconnect PHOTOVOLTAIC AC - - DO NOT RELOCATEAC THIS OVERCURRENT • • DISCONNECT DEVICE (CB): Combiner Box Distribution Panel Interior(DC): DC Disconnect • • Label Location: (INV): Inverter With Integrated DC Disconnect MAXIMUM AC A ' -•I) (LC): Load Center OPERATING CURRENT Per Code: AC VNEC 690.54 -• Point of • • OPERATING VOLTAGE - 1 1 1• / / 1 1 1 1 3055 aearview WaySan Mateo,CA 0 11 1 \1 1 1 _., ^SOlaf�lty ZepSolar Next-Level PV Mounting Technology ','SOlarCity ZepSolar Next-Level PV Mounting Technology Components Zep System for composition shingle roofs i _ ..... - ................ f, Leveling Foot 9j $ItertOCtl Ground Zep �ewct§tpFaot — Part No.850-1172I _ - ETL listed to UL 467 l II Zep ComRatNtle PV Module Zep Gr�e r. Rad Attachment Array$1001t ,: Comp Mount Part No.850-1382 Listed to UL 2582 v' Mounting Block Listed to UL 2703 Aft �COMPAT,e �F Description ! PV mounting solution for composition shingle roofs rFo \�� Works with all Zep Compatible Modules CoMPP, Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" �L LISTED Interlock Ground Zep V2 DC Wire Clip Specifications Part No.850-1388 Part No.850-1511 Part No.850-1448 Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to UL 1565 • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Array Skirt, Grip, End Caps Part Nos.850-0113,850-1421, zepsolar.com zepsolar.com Listed o L 156567 Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspals.com, responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM solar=ee Solar` ' r SolarEdge Power Optimizer Module Add-On for North America P300 / ?350 ( P400 SolarEdge Power Optimizer P300 P350 -P400 „ Module Add-On For North America (forodule1 PV (formodules PV (formodules-cell PV �j++''��(rgg rr�� [ �}3 (q ( ry/1(p(� modules) ,... modules)„ .modules) ...... __. P300 300 1 f 350 ( f ` 00 • Rated Input DC Power('_ . 300 350 400 W INPUT ® Absolute Maximum Input Voltage(Voc at lowest temperature) 48 60 80 Vdc I.. f y "x 'K MPPT Operating Range 8-48 8-60 : 8-80 Vdc Maximum Short Circuit Current(Isc) 10 Adc �, % rMaximum DC Input Current 12.5 Adc Maximum fficiency I, Weighted e Categor1 011 y y 9915 Ove g r W R11 15 gi OUTPUT ODURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Adc WN Maximum utput Current i5 �# x� Maximum Output Voltage 60 Vdc OUTPUT DURING STANDBY)POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) T STANDARDSafety Voltage COMPLIANCE Power Optim¢er 1 - Vdc - _ EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(class II safety),U1.1741 RoHS Yes I INSTALLATION SPECIFICATIONS 1111,11 '41,47, ';y.., Maximum Allowed System Voltage 1000 Vdc Dimensions(W x L x H) 141 x,212 x 40.5/5.55 x 8.34 x 1.59 mm/in a Weight(including cables) 950/2.1 gr/Ib v p Input Connector MC4/Amphenol/Tyco Output Wire Type/Connector Double Insulated;Amphenol Output Wire Length 0.95/30 1.2/3-9 m/ft Operating Temperature Range -40-+85/-40-.185 'C/'E Protection Rating IP65/NEMA4 - Relative Humidity 0-100 Rated STCpowerorlle,n dull.Moduleofupt.,5%powertoleranceallowed. . . PV SYSTE.MDESIGN USING A 50LAREDGE.... . .._. _..T H REE PHASE THREE PHASE SINGLE PHASE .._. _ -- - INVERTER 208V 480V C}2fiTlZat®f1 d ) ;. Minimum String Length(Power Optimizers) 8 10 18 oll Maximum String Length(Power Optimizers) 25 25 50 +++ tJpto 259&more energy, Maximum Power per String 5250 6000 12750 W *^ Superior efficiency(99.5%) Parallel Strings of Different lengths or Orientations Yes ® Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading flexible system design for maximum space utilization . Fast installation with a single bolt - Next generation maintenance with module-level monitoring — Module-level voltage shutdown for installer and firefighter safety I .. ;IRr P.,' "A C' 'RP,N,t - 1Ar ANP, s.A,. r _TRn -v vjw.S t;3 rt d,,'..US THE Trinamount P00DULE TSM-PD05.18 Mono Multi Solutions DIMENSIONS Of PV MODULE E"ECTIR-C AL DATA,4 SIC UnWrom, Peak Power Watts-P-(Wp) 245 250 255 260 941 Power Output Toterance-P.AA(7.) 0-+3 -TION Maximum Power Voltage-Vmp(V) 29.9 30.3 30.5 30.6 o L�"o A Maximum ower urren--PP TH E TrinalwNI-%lount NAMEPLATE I Open Circuit Voltage-Voc(V) 37.8 38.0 38.1 38.2 HOLE Short Circuit Current-Isc(A) 6.75 8.79 8.88 9.00 INStAU1NGM Module Efficiency rl,-, 15.0 15.3 15.6 15.9 STC Irradiance l000 w/nh'.Cell Temperature 25°C,Air Mass AMI,5 according to EN 09o,4-3.'11-� L-ju LE Typical efficiency reduction of 4.5%a1200 W/m2 according to FIN 60904-1 EC.-1i DATA:�"NOCT Maximum Power-P-(WP) 182 186 190 193 60 CELL Maximum Power Voltage-Vmp(V) 27.6 28.0 281 28.3 MULTICRYSTALLINE MODULE E-04 3 GROUNNNG HOLE Maximum Power Curreri(A) 6.59 6.65 6.74 6.84 /U WITH TRINAMOUNT FRAME -.A.N If A- -A Open Circuit Voltage(V)-Voc(V) 35.1 35.2 35.3 35.4 Short Circuit Current(A)-Isc(A) 7.07 7.10 7.17 7.27 NOCT:Irradiance at 800 W/ml,Ambient Temperature 20°C,Wind Speed I ri 245-260wvv PD05.18 Back View POWER OUTPUT RANGE MECHANICAL DATA 11 Solar cells multicrystolline 156 x 156 mm(6 inches) Fast and simple to install through drop in mounting solution Cell orientation 60 cells(6-10) 15 Module dimensions 1650 x 992 x 40 mm(64.95 x 39.05 x 1.57 inches).970 --------------- ------------ Weight 21.3 kg(47.0 lbs) MAXIMUM EFFICIENCY Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass ISOCKSne Good aesthetics tor residential applications Frame Black Anodized Aluminium Alloy with Trinamount Groove I-V CURVES OF PV MODULE(245W) J-Box 1?65 or IP 67 rated Oo-*o+3'7o Cables Photovoltaic Technology cable 4.0 MM2(0.006 inches'). ........... 1200 mm(47.2 inches) POWER OUTPUT GUARANTEE9wi 1222EA-.2 Fire Raring Type'2 Highly reliable due to stringent quality control 7. 6.1 6000WjrW 5.- As leaciii g4.- 40OWW TEMPERATURE RATINGS MAXIMUM RATINGS 3.- nroduc'3 kDsl bel;eve-- - 2�-1 200wim Nominal Operating Cell - ' Operational Temperature -40-85"C 44C(±2C) cor,peratincf-w th n oa.llner-. Temperature(NOCT) Maximum System I OOOV DC(IEC) Temperature,Coefficient of Pm. -0.41%/'C Voltage IGOOVDC(UL) 0.. to.- 30 crific"'i fc" 20 .- 40.m ence VoIage(V) Temperature Coefficient of Voc -0.32%/'C Max Series Fuse Rating 15A C 6 "T 11"srvi;:6 Certified to withstand challenging environmental Temperature Coefficient of Isc 0.05%/*C D j0o 1 t;t- n i v v conditions rci 0: t Ine h"'Ck"gi Tri WA RRANI Y 10 year Product Workmanship Warranty 01 i,ote- m i V 25 year Linear Power Warranty dT>v r r''.; (Please refer to product warranty for details) and p�j"r-,r s as t! CERTIFICATION j �r t.""g, ThCr. LINEAR PERFORMANCE WARRANTY VK=al NG C04FILEqATION ...........---------- L�L .@us callus --------- ....... ....... 10 Year Product Warranty-25 Year Linear Power Warranty Modules per box:26 pieces Trino Solar Lfrinled - ............-..............I..........11....... .......... modules per 40'container:728 pieces a EL-WEEE COMPT 90M fna,SoIcIrs line, r fy CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. oMPAr, THnasolar 9 2014 Trina Solar Limited.All rights reserved.Specifications included in this claf-heef are subject to Trin-asolar change without notice. Smart.Enemy Together Years 5 10 15 20 25DMPP THE Trinamount MODULE TSM-PDO5.18 Mono Multi Solutions DIMENSIONS OF PV MOD jI I ELECTRICAzl DATA;4,STC. umi:nlm Peak Power Watts-PMAX(Wp) 250 255 260 265 941 Power Output TolerdnCe-P-x(%) 0-+3 Maximum Power VoLlci(V) 30.3 30.5 30.6 30.8 THE JUNCTION R. Maximum Power Cvrrei(A) 8,27 6,37 8.50 8.61 AMEPLATE MA rinamou' ' nt Open Circuit Voltage-Voc(V) 38.0 38.1 38.2 38.3 ' Short Circuit Curren lac JA) 8,79 8.88 9,00 9.10 Module Efficiency rfr,(%) 15.3 15.6 15.9 16.2 STC:Irradiance 1000 W/m',Cell Temperature 25*C,Air Mass AM1.5 according to FIN 60904-1 MODULE Typical efficiency reduction of 4.5%at 200 WIm,according to EN 60904-1. T, ELECTRICAL LIATA#NOCT Maximum Power-PIAX(Wp) 186 190 193 197 6' 0 Cli E L L Maximum Power Voltogei-Vmp(V) 28.0 28.1 28.3 28.4 Maximum Power Current-l-P(A) 6.65 6.74 6.84 6.93 MULTICRYSTALLINE MODULE 10 1 3 GROUNDING HOLE A- -A Open Circuit Voltage(V)-Vac(V) 35.2 35.3 35,4 35.5 WITH TRINAMOUNT FRAME PD05.18 Short Circuit Current(A)-lsc[A) 7.10 7.17 7.27 7.35 NOCT:Irradiance at 800 W/m'.Ambient Temperature 20°C,Wind Speed I m/s 812 180- 250-265"AwBack ViewMECHANICAL DATA POWER OUTPUT RANGE Solar cells Multicrystalline 156 x 156 mrin(6 inches) Fast and simple to install through drop in mounting solution I Cell orientation 60 cells 16-10) Module dimensions 650 x 992 x 40 Firm(64.95 x 39.05 x 1.57 inches) UeA Weight �9,6 kg(43.12 lbi ------------------- Glass 3.2 Firm(0.13 inches),High Transmission,AR Coated Tempered Glass 16.4 MAXIMUM EFFICIENCY A-A Backsheet White Frame Black Anodized Aluminium Alloy Good aesthetics for residential applications J-Dox IP 65 or IP 67 rated Cables Photovoltaic Technology cable 4.0 MM2(0.006 inches'), 1200 mm(47.2 inches) .........- ................... I-VI-URVi OF PV MODULEk'26OW1 Connector H4 Ampherhol POSITIVE POWER TOLERANCE IoDo coo Fire Type UL 1703 Type 2 for Solar City Highly reliable due to stringent quality control 8G. ROOW FDO 6'Do 4ATINGS PA A X U,',0 AA R A 9 ..................... ai kea6!ig g:oo-.:'snor ufoct,..rc�I 5DD C'J nextr qeneitz-'4'q' Operational Temperature 40-+g5°C o :Do IN Nominal Operating Cell 44°C(±2'C) -7 "", - -C) p?a rz e o e!i��v sa C 0 e 4,001W GO Temperature(NOCT) Maximum System 1000VEIC(IIE .............- ........................ .......... 2.11 Temperature Coefficient of Pwi� 0.41%/'C Voltage JOOOVDCJUL) ese nd the - I�oo Temperature Coefficient of Vac 0.32%/'C Max Series Fuse Rating 15A pr 7-ice alo: e, "Mie to provioe exceptional e ry ae o 30 so Temperature Coefficient of lso Q;O5�.1°C I o e a h u.St.o t n c r �a c I-,-r,a I k,e Certified to withstand challenging environmental von-"M conditions x d ;ve, felkable prnduct� ith lrie bC,-','ktiic4 24-0 lrbnn<cole WARRANTY ,.I r ri arr,comm r d 10 year Product Workmanship Warranty CERTIFICATION airig smci-'aic,anit IV 25 year Linear Power Warranty i ;'iciol col1ofi vJth C& ®ushoUG (Please refer to product warranty for details) < R --- d of ,c pi orias litle FM d ,vin c r I-,o, c,9y T,:�ge 1 h e I, LINEAR PERFORMANCE WARRANTY PACKAGING CONFIGURATION .......... .................--.-............ .......... COMMANT 10 Year Product Worronty-25 Year Linear Power Warranty Modules per box:26 pieces ................................. Tir!na Solar Limited Modules per 40'container:728 pieces R 100% Adefiri"'a 111 from Trina sofar's 90%a fine- CAUTION READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE P1C.1CT- ot4PAP, 6 0 2015 Trino Solar Limited.All righk,use-c!Specificationstions md,ded in this dotashoot __'joc".80% olar change without notice. I ggr THh'alsolar f3 Trin-as srnort'-?1erqv Togeth"r Year' 5 10 15 20 25 MPP solar=@eSingle Phase Inverters for North America soIar - • • - SE300CA-IIS,,SE38GOA-11S/SE500OA-ESS/SE5o00A-US SE7500A-ES 1 SE1000;fA-JS I SEI 1400A-US SE3000A-US SE380OA-US SESOOOA-US ':SE600OA-US' SE760OA-US_ SE10000A-USI SE1140OA-US OUTPUT SolarEdge Single Phase Inverters - --- _ _ _ 1D000@240V Nominal AC Power Output 3000 38D0 5000 5000 7600 9980 @ 208V 11400 VA 5400 @ 208V 10800 @ 208V For North America Max.AC Power Output 3300 4150 5450 @240V 6000 8350 . 10950 @240V 12000 VA AC Output Voltage Min.-Nom.Max° _ ✓ _ ✓ _ 183-208-229 Vac SE300OA-US/SE330OA-US/SE500OA-US/SE600OA-US r AC Output Voltage Min.-Nom.Maxlt ✓ ✓ ✓ ✓ ✓ ✓ ✓ SE760OA-US f SEIOOOOA-US! SE1140OA-US 211-240-264 Vac AC Frequency Min.-Nom."Max ui 59.3"60-60.5(with HI country setting 57 60-60.5) 11z 24 @ 208V 48 @ 208V Max Continuous Output Current 12.5 16 2 25 32 47.5 A h }' C 40V 2 @ 240V " f � GFDI Threshold 1 - A jrc ,,., Utility Monitoring,Islanding Protection,Country Configurable Thresholds 1 -Yes ,..,... ... Yes r2 �z +� ��� INPUT - i '. r Maximum DC Power(STC) 4050 5100 6750 8100 ....10250 13500 15350 W Transform 7 " ansform ei-less,Ungrounded Yes Max.input Voltage 500 Vdc Nom.DC Input Voltage 325 @ 208V/350 @ 240V Vdc 16.5 @ 208V 33 @ 208V a¢!S4 Max.Input Current 9.5 1318 23 34.5 Adc 1.5.5 @ 240V 30.5 @ 240V 3" - Max Input Short Circuit Current 45 Adc - �' Reverse Polarity Protection. Yes -PliP �a ��' ,��.•-�,,. - �F Ground-Fault Isolation Detection 600ks Sensitivity MM Maximum Inverter Efficiency 97.7 98.2 98.3 98.3 98 98 98 fi.� t. < 9'/5 @ 208V 97 @208V B . --�` CEC Weighted Efficiency 97.5 98 97.5 97,5 97 5 98 @ 240V 97 @ 240V r 'A`z , " Nighttime Power Consumption <2.5 __.. ....... _.... <4 :_.. W .............. ...... _.... _... �2 3 ADDITIONAL FEATURES Supported _._ .._. RS4M,RS232,Ethernet,ztgBee.(optionaq.... -- _. _.. . -.. r --- 1I t Revenue Grade Data,ANSI C12.1 = Optional"' _:� _ _ �;, Rapid Shutdown NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit is installed(4) '- " - - - 21117 CSA 22.2 STANDARD COMPLIANCE Safe 998,ULi9 , T 4` UI.16 98 C Grid Connection Standards IEEE1547 '. Emissions __. __. -_. ...__ _.. FCC.pari15 class B....... ".. __ _.._ ..... _. % INSTALLATION SPECIFICATIONS 1.. AC output conduit size/AWG range 3/4"minimum/16-6 AWG 3/4"minimurn/8-3 AWG DC input conduit size J#of strings/ 3/4"minimum(1-2 strings/ 3/4"minimum/1-2 strings/1.6-6 AWG 3 AWG range 14-6 AWG f Dimensions with Safety Switch30.5 x 12.5 x 10.5/ in/ s 3C.5x12.5x7.2/"775x315x184 (HxWxD) 775 x315x260 rim Weight with Safety Switch 51.2%23.2 54.7/24.7 88 A/40.1 Ib/kg Natural - .... ... .. - convection Cooling Natural Convection and internal Fans(user replaceable) far.(user The best choice for 5otarEd a enabled sy Stems replaceable) Noise <25 <50 dBA • integrated arc fault protection(Type 1)for NEC 2011690,11 Compliance Min.-Max.Operating Ternpe,attire Range -13 to+140/-25 to 160(-40 to+60 version available"') "F J'C Superior efficiency(98%) {. y ,y y, Protection Rating NEMA 3R r Small lightweight and easy to install 1n provided bracket For other regional settings please contact SolarEdge support. �y A higher current source may be used;the inverter ill limit its input current m the values stated. ® Built-in module-level monitoring Revenue grade inverter P/N.SExxx.A US0001,41,1112(for 760OW inverter sE7600A U5002NNR2) Rapid shutdown kit P/N:SE1000-Il 1. Wireless yrc Internet connection through Ethernet or -40 version P/N:SE...xA-US000NNU4(for 760OW nverter SE7600A-U5002NNU4(- Outdoor and indoor installation Fixed voltage inverter,DC/AG conversion only Pre-assembled Safety Switch for faster installation Optional-revenue grade data,ANSI C12.1 �, ROHS C P1k.° Y -"....,C:E n L: t.?t"JA x. f °I.; ;,; f:rC ` .7 'S: .?E. www..solare ge.us