Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
29-103 (9)
ON APR 9 N16 SolarCity DE 0 �r�zas tin.: i'c;, t,r^,v1C,Ci0 April 14, 2016 NORTHAMPTON BUILDING/ELECTRICAL DEPT Enclosed is a re-design update for: Clay Cummings 454 Ryan Rd Florence, MA 01062 Per engineering and design, system has been redesigned to incorporate all MP's. Changes: • System redesigned to incorporate all MP's. Modules added to MP5, 6, 7, 9. System Size: 6.5 kW Please add the new drawings to the permit numbers issued for this address: If anything else is needed, please contact me directly. Sincerely„ Victoria Junck Permit Coordinator SolarCity ------------------------------------------------------------------------ t: 978.215.2367 m- 413.454.9753 604 Silver Street,unit#3,Agawam,MA 01001 T (888)SOL-CITY solarcity.com AL 05500,AR M-8937.AZ ROC 243771/ROC 245450,CA CSLB 888104,CO EC8041.CT HIC 0632778/ELC 0125305.DC 410514000080/ECC902585,DE 2011120386/Tl-6032.FL EC13006226.HI CT-29770.IL 15-0052,MA HIC 168572/ EL-1136MR.MD HIC 12894 8/11805.NC 30801-U.NH 0347C/12523M.NJ NJHIC#13VH06160600/34EB01732700,NM EE98-379590,NV NV20121135172/C2-0078648/82-0079719,OH EL.47707.OR CB180498/C562.PA HICPA077343,RI AC004714/Reg 38313.TXTECL27006.UT 8726950-5501.VA ELE2705153278,VT EM-05829.WA SOLARC'91901/SOLAARC"905P7,Albany 439,Greene A-486.Nassau H2409710000,Putnam PC6041.Rockland H-11864-40-00-00.Suffolk 52057-H.Westchester WC-26088-1-113.N.Y.0#2001384-0CA.SCENYC-N.Y.C.Licensed Electrician.#12610.#004485.155 Water St.6th FI..Unit 10,Brooklyn,NY T1201,#2013966-DCA.All loans provided by SolarCity Finance Company,LLC. CA Finance Lenders License 6054796,SolarCity Finance Company.LLC is licensed by the Delaware State Bank Commissioner to engage In business in Delaware under license number 019422.MD Consumer Loan License 2241,NV Installment L oan License ILT1023/1111024,Rhode Island Licensed Lender#20115,310111,TX Re®stered Creditor 1400050963-202404.V-Lender License#6766 solar=@@ Single Phase Inverters for North America SoIar - • • - . SE300OA-US;SE3860A-US/SE50i0DA-US/SE6000A-US SF7660A-LiS,%Si=100017A-US/SF114iCIA-US _. ...... _..... SE3000A-US SE380OA-US SESOOOA-US SE6000A-US SE760OA-US SE10000A-US '.. SE1140OA-US ... ....... OUTPUT SolarEdge Single Phase Inverters . 10000 @240V 9980 @ 208V Nominal AC.Power Output 3600 3800 5000 6000 7600 11400 V.4 5400 @ 208V 10800 @ 208V For North America Max.AC Power Output 3300 41St} 5450 @240V 6060 8 10950 @240V 12060 VA AC Output Voltage Min.-Nom.-Max 11 - ✓ - ✓ 1.83-208-229 Vac SE300OA- S SE330OA-US/SE500 A-US r SE600OA-US! ACOutput Voltage Min.-Nam.-Max' ✓ ✓ ✓ ✓ ✓ ✓ ✓ SE 60OA-USi SE1000 A-US SE11 0OA-US z11-240-264 Vac AC Frequency Min.-Nom:Max.(11 59.3-50-60.4(with hit country setting 57-60-61 Hz Max.Continuous Output Current 125 16 24 @ 208V 25 32 48 @ 208V 47 A 21 @ 240V _ 42 @ 240V GFDI Threshold A Utility Monitoring,Islanding Protection,County Configurable Thresholds Yes yes INPUT kerter '„ Maximum DC Power(SIC) 4050 5100 6750 8100 10250 13500 15350 W Transfo r mer-less,Ungrounded Yes Max.Ma Input Voltage 500 Vdc �y Waft Norn.DC Input Voltage 325 @ 208V/350 @ 240V Vdc p _ _ 523 @ 70R V Max.Input Currentln 9 5 13 1 .5 7 18 40V 3023 34.5 Adc .5 @ Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600ku Sensitivity '.., Maximum inverter Efficiency ! 97.7 98.2 98.3 98.3 98 98 98 % 97.5 @ 208V 97 @ 208V CEC Weighted Efficiency 97 5 98 98 @ 240V j 97.5 97.5 97.5 @ 240V 97.5 Nighttime Power Consumption <2.5 <4 W . ADDITIONAL FEATURES Supported Communication Interfaces RS485,RS232,Ethernet,ZigBee(optional) Revenue Grace Data,ANSI C12-1 Optional"' Rapid Shutdown--NEC 2014 690.12 _ t unctionality anabled when_SolarEdge.rapid shutdown kit is instaheritn STANDARD COMPLIANCE Safety L111741,UL1699B,UL1998,CSA 22.2 Grid Connection Standards ILLE1547 _ Emissions _. FCC part75 class ti INSTALLATION SPECIFICATIONS AC output conduit size/AWG range 3/4"minimum/i6-6 AWG 3/4"rninimum/8-3 AWG DC input conduit size/4 of strings/ 3/4' minimum/ 2 strings/ "s/f"minimum/1-2 strings/16-6 AWG a AWG range _ 14-6 AWG .. ,,,...- Dimensions with Safety Switch 30.5 x 12.5 x 1U.S/ in/ (HxWxD) 305 x 12S x 7.2/775 x 315 x 184 775x315x260 mm Weight with Safety Switch `51.2;23.2 54.7/24.7 88.4/40.1 Ib/kg Natural 19F1 " convection Cooling Natural Convection and infernal Fans(user replaceabe) ,,g {,,,e fan(user The best choice for Solar�dgE' enabled systems Noise <25 replaceable) <50 dEA Integrated arc fault protection(Type 1)for NEC 2011690.11 compliance Min.-Max.Operating Temperature 13#o+140/ 25 to+60(-40 to a60 version available"') F/"C — Superior efficiency(98%) Range Protection Rating NEMA 3R — Small,lightweight and easy to install on provided bracket For other regional settings please contact SolarEdge support. 11 A h gher current source maybe used the-nverter w II I'm-t,,,np,t current to the values stated. ® Built-in module-level monitoring 3 Revenue gradeoverterP/N'SEk...AUSODONNR2(for 760OW-nverter SE7600A-uS002NNR2) -Sl. �°Rapid shutdown kit P/N:SE1000-RSD Internet connection through Ethernet or Wireless �s�40 version P/N:SExxxxA-USDODNNU4(tor 7600W InverterSE7600A-USo02NNu4). — Outdoor and indoor installation — Fixed voltage inverter,DC/AC conversion only — Pre-assembled Safety Switch for faster installation — Optional—revenue grade data,ANSI C12.1EM . • HS E .. ,IAIl3� �wnlpJpQMMI,w THE mount MODULE TSM-.18 Mono Multi Solutions DIMENSIONS Of P'>;MO>l.ilE ELK-REAL DATA.e,STC u'it`rnm Peak Power Watts-PMAx(Wp) 250 255 260 265 941 -- ------941 Power Output Tolerance-PMAx(%) 0-+3 EMaximum Power Voltage-VMP(V) 30.3 30.5 30.6 30.8 96 THE Tinnal 11 U I I t C,ox Maximum Power Current-IMP?(A) 8.27 8.,37 8.50 8.61 LATE o Open Circuit Voltage-Voc(V) 38.0 38.1 38.2 38.3 4a9„LL:ING MOLE Short Circuit Current-Isc(A) 8.79 8.88 9.00 9.10 INSTA Module Efficiency qN,(%) 15.3 15.6 15.9 16.2 it MODULE STC:Irradiance 1000 W/m',Cell Temperature 25°C.Air Mass AWS according to EN 60904-3. Typical efficiency reduction of 4.5%at 200 W/m2 according to EN 60904-1. 0 - Ao wE S C A L'IATA ,T Maximum Power-PMAx(Wp) 186 190 193 197 60 CELL �t Maximum Power voltage-VMP(V) 28.0 28.1 28.3 2&4 MULTICRYSTALLINE'MODULE DRAIN __- Maximum Power Current-l-(A) 6.65 6.74 6.84 693 tr0 4.3 GROUNDING HOLE PD05.18 A A Open Circuit Voltage(V)-Voc(Vj 35.2 35.3 35.4 35.5 li HOLE WITH TRINA OUNT FRAME Short Circuit Current(A)-Isc(A) 7.10 7.17 7.27 7.35 NOCT:Irradiance at 800 W/m'.Ambient Temperature 200C,Wind Speed I m/s. 812 180 Back View + :", A N. A L,xn>A ... .�. ,..mz. ...: ... . POWER OUTPUT RANGE Solar cells Multicrystalline 156 x 156 mm(6 inches) 11 Cell orientation - 60 cells(6 x 10) - . Fast t ri staple to install fl rou l I drop in mountingst luf.® ;$ Module dimensions 1650 x 992 x 40 mm(64.95 x 39.05 x 1.57 inches) 16 �e,>„,.� � _. _. ___ _ � Weight 19.6 kg(43.12 lbs) ��aa a i V Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass MAXIMUM EFFICIENCY A-A Backsheet white Frame Black Anodized Aluminium Alloy -- Good oesthefics for re's denti al applications J-Box IP 65 or IP 67 rated Aft 0%0+ � Cables Photovoltaic Technology cable 4.0 mm°(0.006 inches'), 1200 mm(47.2 inches) POSITIVE POWER TOLERANCE CURVES 0-- NAODVl Etz60W1 connector H4 Amphenol °DO 9.00300° - --- - Fire Type UL 1703 Type 2 for Solar City �j ly reliable due to stringent qTi It , control -- aoow�_? C .;. -r, .r 't, Y ._ ., .� _.0 ,,.. ., -,,. „ R eoowl.' TE"7*r UIi RATING..S MAX kt: __RAS I a .==r _ . , �..S d00 1 Nominal Operating CellOperational Temperature -40-+g5°C All'' ... -' _ Temperature(NOCT) 44°C(±2°C) eoo - - - - Maximum System t000V DC IEC) _-- - -- --__- .......... __-- "- zoo -� � -- - Temperature Coefficient of Pv O, '0.41%/°C Voltage 1000V DC(UL) Temperature Coefficient of voc 0.32%/'C Max Series Fuse Rating 15A ertifieto-withstand challengingenvironmental o o z° so 40 so Temperature CoefficienToflsc 0.05%/°C -- . .. vonRs°NI WARRANTY 10 year Product Workmanship Warranty ERT;:i,,ATION } t 25 year))near Power warranty C& ��}° (Please refer to product warranty for details) C U _ . r LINEAR PERFORMANCE WARRANTY �" _�' PACKAC-€1.G3-OdFIGL ATIC'Ni EU28WEE, _ _.__. CO Pl Nt - - -- - '01 You Product Warranty-26 Year Linear Poww Warranty.._ MIA Modules per box:26 pi ce 728 pieces as l#ed-� - - loo% Ytl srtvaiu for 75.; IT 090% , S1aP0- ftli4P1'Wi2rgt�'tp}, CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. QGaMV4Te ISI' Trinalcolar " O 80%Years ' 5 '� 10 �Y, IS vel 20 25 d changerlwithoutt no ce.d.All rights reserved.Specifications included in this datasheet are subject to ,� vMPn Yom. Mono Multi Solutions DlMfNS�C)N�OF FV MDOU'll, Peak Power Watts-P-(WpJ 245 250 255 260 941 -- ---------- Power Output Tolerance-Pmen(%) 0-+3 Maximum Power Voltage-VmP(V) 29.9 30.3 30.5 30.6 o HE. o THE Tr i na Irvi o lum I I t eoz Maximum Power Current-l-P(A) 8.20 8.27 8.37 8.50 - I o Open Circuit Voltage-Voc(V) 37.8 38.0 38.1 38.2 sawr+c 1o11 Short Circuit Current-isc JA) '.. 8.75 8.79 8.88 9.00 Module Efficiency q,,,(%) 15.0 15.3 15.6 15.9 STC:Irradiance 1000 W/m°,Cell Temperature 25°C,Air Mass AMI.5 according to EN 60904-3. Typical efficiency reduction of 4.5%at 200 11/ml according to EN 60904-1. 0 rn - so O o ELECTRa�,A_D,4 CT 60 L Maximum Power-P.-(Wp) 182 186 190 193 LMaximum Power Voltage-VMP(V) 27.6 28.0 28.1 28.3 MULTICRYSTALLINE MODULE beat GNouNDIHC HOLE - Maximum Power Current-ImPP(A) 6.59 6.65 6.74 6.84 WITHTRINAMOUNTFRAME aoRAH-.1E A A Open Circuit Voltage(V)-Voc(V) 35.1 35.2 35.3 35.4 Short Circuit Current(A)-Isc(A) 7.07 7.10 7.17 7.27 NOCT:Irradiance at BOO W/m'.Ambient Temperature 20°C,Wind Speed 1 m/s. PD05.18 Back View 812 -186-d POWER OUTPUT RANGE 77=L DAT-1 11 Solar cells Multicrystalline 156 x 156 mm(6 inches) Fast and simple to install through dropin mounfing natation Cell orientation 60 cells(6 x 101 1,5 .,. Module dimensions 1650 x 992 x 40 mm(64.95 x 39.05 x 1.57 inches) eight 21.3 k 47.0 lbs MAXIMUM EFFICIENCYGlass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass -_ A-A Backsheet White Gooey aesthetics for residential p lica ions Frame Black Anodized Aluminium Alloy with Trinamount Groove r, F PV a a J-Box IF 65 or IP 67 rated #fV 1 P Z.,rt 4'.;.,O ;t+b OL � C= Photovoltaic Technology gY cable 4.0 mm'(0.006 inches'). ........ _._._ ___... ........ .......__ ____. ......... _............_ ........... tom. - ___._... - ----- -__.. 1200 mm(47.2 inches) POWER OUTPUT GUARANTEE 9 W lWow/m' _ e.- Fire Rating type z _ A 7m BooW/m Highly reliable dire to stringent quality control T'j5 bDDW m, � .s.. „ URR T> iATMGL .A 1NaMEA a'.>`s d 2°1 2oow/m� � Nominal Operating Cell 44°C(+2°C) Operational Temperature -40-+85°C J.. Temperature(NOCT) Maximum System 1000V DCJIEC) - __- _-- --- "_- oL0`----- Temperature Coefficient of P.A. -0.41%/°C Voltage 10.i- 20m 30m 40°' 1000Y DCJULJ •„ „t O.w Voltage(V) Temperature Coefficient of Voc -0.32%/°C Max Series Fuse Rating 15A r 8 } _ C, Temperature L£dl 'SSI: :" E,:,t? fi'tli?" `°.fSE1"? f Temperature Coefficient of kc 0.05%/°C r ndi cn-, Kk _STT -- �- 10 year Product Workmanship Warranty 25 year Linear Power Warranty (Please refer to product warranty for details) 1 - LINEAR PERFORMANCE WARRANTY CFG11RATI ,ISO- 10 PACKAGING it nx Solar Lrlfe= ..... Modules per 40'container 728 pieces z - .. _ - `m 100% �i✓ � � ActdFPtorTel v41u: EU z�eE 0 90% »m isr,,a .O.iZ • comvuaHr CAUTiON�READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT QaaMP4Txe! 1 s o _ v 0°2014 TrNina Solar Limited.All rights reserved.SpecifCations included in this datasheet are subject to g :3 19 80% y ,, ,,_. change without notice. Trin-asYears 5 10 IS 20 25 solar " • = So I a�' • • r SolarEdge Power Optimizer Module Add-On for North America P300 f P350 I P400 SolarEdge Power Optimizer �ISII, P300 P350 P400 Module Add-On For North America "orb°-cellPv (for 72-cell PV (for 96-tellPv modules) modules( modules) �y+t / yry p�7 p� UT L.300 / 1 ,350 f P400 • ISI RNaed Input DC PowerP� ... g ( . ... 300 ..... ... 350 ....._400 _... W ... Absolute Maximum In ut Voltage Voc at lowest temperature) 48 60 80 Vdc a., MPPT Operating Range 8-48 8-60 8-80 Vdc Maximum rt Circuit 10 Adc dT� • CMaximum DCInp it Current Current(Isc) 125 Adc f s. Maximum Efficiency 99.5 1 f „_„ WeightedEffiaergC1 y _ _ 988 __ 7 _ € OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED OPERATING INVERTER) r",�3 = 3 Y MaximOvervoum m0 Output NECTETO OP Current ..... _ _. 1S Adc ti ,a, I Maximum Output Voltage 60 Vdc >" ,;' • OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED_FROM INVERTER OR INVERTER OFF) Rsp =a 1 Vdc Safety Output Voltage per.Power Optimizer STANDARD COMPLIANCE - @ g EMC FCC Part1S Class B,IFC61000-6-2,IEC610006-3 Safety IEC62109-1(class hsafety),UL1741 RCHS Yes INSTALLATION SPECIFICATIONS..._ Maximum Allowed System Voltage �-,-l: � y - 1000 Vdc xi Dimensions WxLxH 141 x 212 x 40.5/5.55 x 8.34 x 1.59 men Weight(including cables) 950/2,1 gr/h Input Connector MC4/Amphenol/Tyco Output Wire Type/Connector Double insulated;Amphenol Output Wire Length 0.95/3.0 L2/3.9 ro J it Operating Temperature Range 40-r85/-40-+185 'C/°F Protection Rating IP65/NEMA4 Reiatve Humidity 0-100 PV SYSTEM DESIGN USING A SOLAREDGE THREE PHASE THREE PHASE SINGLE PHASE INVERTER 208V 480V PV power optimization at the modiule-level Minimum String Length(Power Optimizers) 8 i0 18 Maximum String Length(Power Optimizers) 25 25 50 — Up to 25%more energy Maximum Power per String 5250 6000 12750 W - Superior efficiency(99.5%) Parallel Strings of Different Lengths or Orientations Yes - Mitigates all types of module mismatch losses,from manufacturing tolerance to partfal Shading - Flexible system design for maximum space utilization Fast installation with a single bolt — Next generation maintenance with module-level monitoring — Module-leve(voltage shutdown for installer and firefighter safety ® .w, Y'^SoiarCity ZepSolar Next-Level PV Mounting Technology ',^SolarCity Zep Solar Next-Level PV Mounting Technology Zep System Components for composition shingle roofs �h q_ep Leveling Foot IntedwA ,,,�.,�„.�,,....- L+evetmg Foca - _'-' Part No.850-1172 ' s L ETL listed to UL 467 Zep compatible PY Moderle s lz t f F F Zep Root Attachment Air;ry Skirt Comp Mount Part No.850-1382 Listed to UL 2582 I Mounting Block Listed to UL 2703 "OMPAT- ,�Q e�F Description PV mounting solution for composition shingle roofs AOS Works with all Zep Compatible Modules �BMPP't Auto bonding UL-listed hardware creates structural and electrical bond - • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" Interlock Ground Zep V2 DC Wire Clip UL LISTED Specifications Part No.850-1388 Part No.850-1511 Part No.850-1448 Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to UL 1565 • Designed for pitched roofs -- --- • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 -7 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Array Skirt, Grip, End Caps Part Nos.850-0113,850-1421, 850-1460,850-1467 zepsolar.com zepsolar.com Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM WARNING:PHOTOVOLTAIC POWER SOURCE ■ : Label • Location:Label ) • -- Code: �A� fN _ :'_ WARNING � Code:. NEC ELECTRIC SNACK yAZp,Rfl' • ELECTRIC SHOCK HAZARD � 690.31.G.3 Dt7 NC7T Tf3t ICH TER1tt11IALS; NEC ' 1 NEC •THE DC CONDUCTORS OF THIS 1 Label _ • TI=RMfiNA S }B3THLIIE q'p PHOTOVOLTAIC SYSTEM ARTO BE USED WHEN E C3AD SES M}sY;3E Efi*JERGIZEt7 UNGROUNDED ANDINVERTERIS PHOTOVOLTAIC -DC ••_ 1N THS QPEN PC3SiT�01�# MAY BE ENERGIZED - OUNDED DISCONNECTPer NEC 6.1 .•- • Label LocationPHOTOVOLTAIC POINT OF ■ MAXIMUM POWER-_ INTERCONNECTION Per Code: A � WARNING: ELECTRIC SHOCK POINT CURRENT{Imp) Per Code: HAZARD. DO NOT TOUCH NEC 690.17 690.54 MAXIMUM POWER- VNEC 690.53 BOTH THE LINE AND LOAD SIDE MAXIMUM SYSTEM V MAY BE ENERGIZED IN THE OPEN VOLTAGE{Voc)� POSITION.. FOR SERVICE SHORT-CIRCUIT DE-ENERGIZE BOTH SOURCE CURRENT(Isc)-A AND MAIN BREAKER... PV POWER SOURCE MAXIMUM AC A OPERATING CURRENT MAXIMUM AC V LabelLocation:Per OPERATING VOLTAGE'_ V1/ARN I N G ..- ELECTRICSHOCK HAZARD 690.5(C) IF A GROUND FAULT IS INDICATED NORMALLY GROUNDEDLabel Location: CONDUCTORS MAY BE CAUTION ■ UNGROUNDED AND ENERGIZED DUAL POWER SOURCE Per ••- SECOND SOURCE IS 690.64.13.4 PHOTOVOLTAIC SYSTEM. Label • • Per Code: Label WARNING . . ELECTRICAL SHOCK HAZARD CAUTION ' DO NOT TOUCH TERMINALS NEC ••1 TERMINALS ON BOTH LINE AND PHOTOVOLTAIC'SYSTEM Code:Per LOAD SIDES MAY BE ENERGIZEDNEC 690.64.13.4 IN THE OPEN POSITION CIRCUIT IS BACKFED DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT Label • • WARNING -. Per ..- INVERTER pUTPUT Label Location: CONNECTION NEC 690.64.13.7 Disconnect PHOTOVQLTAIC AC D NOT RELOCATEAC THIS OVERCURRENT' • • DISCONNECT �d�NEC DEVICE (CB): Combiner Box . Distribution Panel . Disconnect Conduit(IC): Interior Run LabelIntegrated DC MAXIMUM AC -•I) (LC): Load Center CURRENT APer Code: (M): Utility Meter MAXIMUM AC VNEC 690.54 (■. Point of • QPERATING VOLTAGE 3055 Clearview Way San Mateo,CA 94402 Label Set • • i :� . • r • T:(650)638-1028 F:(650)638-1029 • • . GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number:P404OB1200 Inv 1: DC Ungrounded INV i —(1)SOLAREDGE ISE6000A—USOOOSNR LABEL: A —(25)TRINA SOLAR # TSM-260PDO5.18 GEN #168572 ODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:46581223 Inverter; 6000W, 240V, 97.5%d w/Unifed Disco and ZB,RGM,AFCI PV Module; 2150W, 236.9W PTC, 40MM, Black Frame, H4, ZEP, 1000V ELEC 1136 MR Overhead Service Entrance INV 2 Voc: 38.2 Vpmax: 30.6 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER Inverter 1 (E) WIRING CUTLER—HAMMER 1 20OA/2P Disconnect 3 SOLAREDGE Dc+ FOAW MP 2,6&7: SE6000A—USOOOSNR2 DC- 1x14 (E) LOADS A -------- ------------ EGC-------------- ----J L1 r ��- L2 DC+ I ~ N DG I Z 35A/2P ____ GND _ EGCI ___ DC+ MP 4,5&9: ------------------------------------- I A GEC N DG C 1X11 6 GND __ EGC--- ------------- ----t� --------------------- ------------- G I I N I (i)Conduit Kit; 3/4" EMT _J o _EGC/GEC a �5 - -l I I I I I I _ GEC-r-y TO 120/240V I I SINGLE PHASE I I UTILITY SERVICE I I I I I I I I I I PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP O1 (1)SIEMENS #Q235PV BACKFEED BREAKER A (1)CUTLER—HAMMER DG222URB /� PV (25)SOLAREDGE 11'300-2NA4AZS D� Breaker, 35A/2P, 2 Spaces Disconnect; 60A, 24OVac, Non—Fusible, NEMA 3R /y PowerBox Optimizer, 30OW, H4, DC to DC, ZEP —(2)Gro qd RoQ —(1)CUTLER— AMMER 11 DG100N8 (1)AWG #6, Solid Bare Copper Sr8 x 8, Copper Ground�Neutral It; 60-100A, General Duty(DG) nd —(1)Ground Rod; 5/8" x 8', Copper (N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL ;ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE (1)AWG #8, THWN-2, Black (2)AWG x'10, PV Wire, 60OV, Black Voc* =500 VDC Isc =15 ADC O (1)AWG #8, 1HWN-2, Red (1)AWG /6, Solid Bare Copper EGC Vmp 350 VDC Imp 10.26 ADC (11)AWG /10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=25 AAC (1 Conduit Kit 3/4",EMT . , . . . . . . . . .-(1)AWG A.THWN-2,.Green EGC/GEC,-(1)Conduit.Kit_;.3/4".EMT. . . . . , . . , . (2)AWG #10, PV Wire, 600V, Bladc Voc* =500 VDC Isc =15 ADC O (1)AWG /6, Solid Bare Copper EGC Vmp =350 VDC Imp=8.07 ADC (1)Conduit Kit; 3/4" EMT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: JB-0102087 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: ``A�A�OI���'� CONTAINEDDAL SHALL NOT BE USED FOR THE CLAY CUMMINGS Clay Cummings RESIDENCE Kevin Midei ,._ , ORBENESHALL OF IT BEN DISCLOSED N WHOE EXCEPT LEOINRCIN MOUNTING SYSTEM: 454 RYAN ROAD 6.5 KW PV ARRAY TY ''" �/ PART TO OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: FLORENCE, MA 01062 24 St. Martin Drive, Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE 25 TRINA SOLAR TSM-260PDO5.18 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN SHEET: REV: DATE Marlborough,MA PERMISSION OFSOLARgTf INC. INVERTER: PAGE NAME T. (650)638-1028 F: (6550)0) 638-1029 SOLAREDGE SE6000A—LlS000SNR2 I THREE LINE DIAGRAM PV 6 a 4/13/2016 (866)-SOL-CITY(765-2as9) www.solarcitycom S1 S1 4" 5'—g„ 4' _ —6 (E) LBW 1 (E) LBW SIDE VIEW OF MP6 NTS OHSIDE VIEW OF MP7A NTS G MP7A X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MP6 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" STAGGERED LANDSCAPE 72" 24" STAGGERED PORTRAIT 4811 20 PORTRAIT 48" 20" RAFTER 2"x5" @ 24" OC ROOF AZI 72 PITCH 45 STORIES: 1 ARRAY AZI 72 PITCH 45 RAFTER 2"x4" @ 24" OC ROOF AZI 71 PITCH 45 STORIES: 1 C.J. 2"x6" @24" OC Comp Shingle ARRAY AZI 71 PITCH 45 C.J. 2"x6" @24" OC Comp Shingle-Skip Sheathing PV MODULE 5/16" BOLT WITH INSTALLATION ORDER FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. S1 (4) (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. ZEP COMP MOUNT C ZEP FLASHING C (3) (3) INSERT FLASHING. 4 5'-10" (E) COMP. SHINGLE (4) PLACE MOUNT. (1) (E) LBW (E) ROOF DECKING (2) g(5) INSTALL LAG BOLT WITH 5/16" DIASIDE VIEW OF MP9 NTS STEEL LAG BOLNLESS LOWEST MODULE) SUBSEQUENT MODULES SEALING WASHER. K WITH SEALING WASHER (6) INSTALL LEVELING FOOT WITH BOLT & WASHERS. Mpg X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES (2-1/2" EMBED, MIN) LANDSCAPE 72" 24" STAGGERED (E) RAFTER STANDOFF PORTRAIT 48" 20" RAFTER 2"x5" @ 24" OC ROOF AZI 71 PITCH 45 STORIES: 2 ARRAY AZI 71 PITCH 45 Comp Shingle JB-0102087 0 0 PREMISE OWNER. DESCRIPTION. DESIGN. CONFIDENTIAL — THE INFORMATION HEREIN ,108 NUMBER: CONTAINED SHALL NOT BE USED FOR THE CLAY CUMMINGS Clay Cummings RESIDENCE Kevin Midei � �ty BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 454 RYAN ROAD 6.5 KW PV ARRAY ,SolarC■ PART TO OOUTSIDE THE RECIPIENTS MODULES- FLORENCE MA 01062 ORGANIZATI CEPT IN CONNECTION HATH 24 St. Martin Drive, Building Z Unit 11 THE SALE AND USE OF THE RESPECTIVE (25) TRINA SOLAR # TSM-260PDO5.18SHEET: REV: DATE Marlborough, MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME T: (650) 638-1028 R (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE6000A—USOOOSNR2 STRUCTURAL VIEWS PV 5 0 4/13/2016 (886)-SOL-CITY(765-2489) www.solarcity.com S1 S1 4" ,-11„ 01 5'-10" (E) LBW (E) LBW SIDE VIEW OF MP2 NTS D SIDE VIEW OF MP4 NTS DB MP4 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MP2 X-SPACING X CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" STAGGERED LANDSCAPE 72" 24" STAGGERED PORTRAIT 48" 20" PORTRAIT 48" 20" ROOF AZI 252 PITCH 45 RAFTER 2"X5" @ 24" OC ARRAY AZI 252 PITCH 45 STORIES: 2 RAFTER 2"x4" @ 24" OC ROOF AZI 252 PITCH 45 STORIES: 1 ARRAY AZI 252 PITCH 45 Comp Shingle-Solid Sheathing C.J. 2"x6" @24" OC Comp Shingle-Skip Sheathing s1 s1 4" 4" 5—9" (E) LBW (E) LBW D SIDE VIEW OF MP5A NTS F SIDE VIEW OF MPSB NTS MP5A X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MP5g I X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" STAGGERED LANDSCAPE 72" 24" STAGGERED PORTRAIT 48" 20" PORTRAIT 48" 20" RAFTER 2"x6" @ 24" OC ARRAY AAZI 252 PITCH 45 ZI 252 PITCH 45 STORIES: 1 RAFTER 2"x6" @ 24" OC ROOF AZI 252 PITCH 45 STORIES: 1 ARRAY AZI 252 PITCH 45 Comp Shingle-Solid Sheathing C.J. 2"x6" @24" OC Comp Shingle-Solid Sheathing J B-0102087 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: ����r CONTAINED SHALL NOT BE USED FOR THE CLAY CUMMINGS Clay Cummings RESIDENCE Kevin Midei ' ty BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �'� ��SolarCi NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 454 RYAN ROAD 6.5 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES FLORENCE MA 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Martin Drive, Building 2, Unit 11 THE SALE ANiOF THE RESPECTIVE (25) TRINA SOLAR # TSM-260PD05.18 PAGE NAME SHEET: REV: DATE: Marlborough, MA 01752 SOLARCITY E T, WITHOUT THE WRITTEN T. (650)638-1028 F: (650)638-1029 PERMISSION OF SOLARCITYINVERTER: INC. SERTER: GE SE6000A—USOOOSNR2 STRUCTURAL VIEWS PV 4 0 4/13/2016 (888)-SOL-CITY(765-2489) www.solarcity.com 454 Ryan Road PITCH: 45 ARRAY PITCH:45 MP2 AZIMUTH:252 ARRAY AZIMUTH:252 Front Of House F (E)DRIVEWAY MATERIAL: Comp Shingle STORY: 1 Story D K AC PITCH: 45 ARRAY PITCH:45 MP4 AZIMUTH:252 ARRAY AZIMUTH:252 Ll MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 45 ARRAY PITCH:45 Inv MP5 AZIMUTH:252 ARRAY AZIMUTH:252 MATERIAL: Comp Shingle STORY: 1 Story PITCH: 45 ARRAY PITCH:45 MP6 AZIMUTH:71 ARRAY AZIMUTH:71 MATERIAL: Comp Shingle STORY: 1 Story PITCH: 45 ARRAY PITCH:45 MP7 AZIMUTH:72 ARRAY AZIMUTH:72 E D MATERIAL:Comp Shingle STORY: 1 Story STRUCTU LEGEND CTURE CHANGE GE F 3 (E) UTILITY METER & WARNING LABEL Inv INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS B GFDC J©1 DC DISCONNECT & WARNING LABELS AC AC DISCONNECT & WARNING LABELS DC JUNCTION/COMBINER BOX & LABELS - a� DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS I I I O DEDICATED PV SYSTEM METER ______________________________J STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR ,.f CONDUIT RUN ON INTERIOR GATE/FENCE 1� HEAT PRODUCING VENTS ARE RED r,---i I. 'I INTERIOR EQUIPMENT IS DASHED L--'J SITE PLAN Scale:1/16" = 1' 01' 16' 32' F S J B-0102087 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: i►,,S��a�C�t CONTAINED SHALL NOT BE USED FOR THE CLAY CUMMINGS Clay Cummings RESIDENCE Kevin Midei �. a ` BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 454 RYAN ROAD 6.5 KW PV ARRAY �'�� �/ 17 PART TO OTHERS OUTSIDE THE RECIPIENTS MaDULEs FLORENCEMA 01062 ORGANIZATION, EXCEPT IN CONNECTION HATH , 24 St. Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (25) TRINA SOLAR # TSM-260PD05.18 PAGE NAME: SHEET: REV'. DATE:- Marlborough, MA 01752 SOLARCITY EQUIPMENT, OUT THE WRITTEN INVERTER: T. (650)638-1028 F. (650)638-1029 PERMISSION OF soLAR C. SOLAREDGE SE6000A—USOOOSNR2 SITE PLAN PV 3 a 4/13/2016 (888)-SOL-CITY(765-2489) www.sdarcity.com 154 Ryan Road (E)DRNFWAY I E E3 ———————————————————————' I I I I ---------------------------J F PROPERTY PLAN Scale:l" = 20'-0' w 0 20' 40' F S CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: JB-0102087 00 PREMISE OWNER: DESCRIPTION: DESIGN: `\ CONTAINED SHALL NOT BE USED FOR THE CLAY CUMMINGS Clay Cummings RESIDENCE Kevin Midei �:, BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: 1110,5olarCity. NOR SHALL T BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 454 RYAN ROAD 6.5 KW PV ARRAY PART TO OS OUTSIDE THE RECIPIENT'S [MODULES: FLORENCE MA 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH24 St. Martin Drive, Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (25) TRINA SOLAR # TSM-260PDO5.18 PAGE NAME: SHEET: REV: DATE: Marlborough,MA 01752 SOLARgTY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T: (650)638-1028 F: (650)638-1029 PERMISSION Of SOLARCITY INC. SOLAREDGE SE6000A—USOOOSNR2 PROPERTY PLAN PV 2 a 4�13�2016 (888)-SOL-CITY(7s5-z46s) www.solarcitycom ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG B'LDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. 1 CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 PROPERTY PLAN PV3 SITE PLAN PV4 STRUCTURAL VIEWS LICENSE GENERAL NOTES PV5 STRUCTURAL VIEWS PV6 THREE LINE DIAGRAM 1. ALL WORK TO BE DONE TO THE 8TH EDITION Cutsheets Attached GEN #168572 OF THE MA STATE BUILDING CODE. ELEC 1136 MR 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Northampton REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: National Grid USA (Massachusetts Electric) * * * * CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: JB-0102087 00 CONTAINED SHALL NOT USED FOR THE CLAY CUNNINGS Clay Cummings RESIDENCE Kevin Midei �. ;�Ol���'�` BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MWNIING SYSTEM: •.,r, y® NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 454 RYAN ROAD 6.5 KW PV ARRAY � PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES: FLORENCE MA 01062 THEASALE AND USEEOF USE PT IN CONNECTION WITH (25) TRINA SOLAR # TSM-260PDO5.18 24 St.Moron Drive Building 2, Unit 11 SOLARCITY EQUIPMENT, WITHOUT 1 H WRITTEN PAGE NAME: SHEET: REV: DATE: Marlborough, MA 01752 PERMISSION OF SOLARCITY INC. INVERTER: L• (650)638-1028 F: (650)638-1029 SOLAREDGE SE6000A—USOOOSNR2 COVER SHEET PV 1 0 4/13/2016 (888)-SOL-CITY(765-2489) www.solarcity.com