Loading...
235 Septic Plans 2004 Plan to Repair SEPTIC SYSTEM for Steve Mongeon Located at 235 Coles Meadow Road in Northampton, Massachusetts Plan Number 315 Thomas S. Leue, R.S. Homestead Inc. 1664 Cape Street Williamsburg, MA 01096 413 628-4533 fax: 413 628-3973 Design Date: 9/5/04 Updated: Contents Site Plan: 1 page Site Suitability Form 11.1: 1 page On-Site Review Form 11.2: 3 pages Groundwater Form 11.3: 1 page Perc Test Form 12: 1 page Specifications: 3 pages Design Calculations: System 1 page Plan Drawing: 1 page Separate To be signed by Ownerlsl Application for Construction Permit: 3 pages Local Upgrade Approval form: 5 pages 397 oM Farms Rd • ) Work Site Location 18 Coles Meadow Rd. f L 235 Coles Meadow Rd. �* M Mag 15.00 Thu Aug 26 08:29 2004 Scale 1:15,625(at center) 1000 Feet 500 Meters — Local Road — Major Connector — - Trail Interstate/timited Access US Highway o Exit -I—F- Railroad II CONSTRUCTION SPECIFICATIONS Title 5 Septic System Plan for 235 Coles Meadow Road Northampton General a No work on this system construction shall take place until a permit for the approved system plan has been received from the local Board of Health. A copy of the Disposal Works Construction Permit should be on site for inspection during the time of construction. Additional specifications may be included elsewhere in this design. b. Loading requirements are specified for the septic tank on the system calculations page. Loading requirements for any other component are on the drawing. Normal loading systems are designated H-10. If H-20 rating is specified on the drawing and/or on the page for system calculations,the tank or leaching facility shall be custom built to meet the increased loading requirements using additional rebar, greater wall thickness and/or other approved methods. Follow the manufacturer's rating system and installation procedures. 2. Septic Tank Note: Not all plans require new septic tanks. Refer to the drawing to determine if a tank is required. a The septic tank selected by the contractor shall conform with 310 CMR 15.223. The septic tank shall be a minimum effective liquid capacity of 1,500 gallons below the outlet invert,rectangular,and with a minimum length to width ration of 1.5:1. Liquid depth to be 48". Compartmentalized tanks are not to be used. b. Septic tank shall be installed on a minimum of 6"of crushed stone, leveled to grade and thoroughly compacted Septic tanks shall have a minimum cover of 9". No structures shall be located directly upon or above the septic tank access locations which interfere with performance, access, inspection, pumping, or repair. c. All three access covers to the septic tank shall have risers at least 20"diameter, if round,tightly fitted to the tank to resist water infiltration, and terminated with a tight fitting cover no more than 6"below ground surface. If, with the agreement of the Owner, one or more of the risers are terminated flush with ground, these shall be secured against unauthorized entry with stainless steel hardware. d. Inlet and outlet tees shall be of Schedule 40 PVC and shall extend a minimum of 6"above the flow line of the septic tank and be on the center line of the septic tank located directly under the clean-out manhole. All ..fittings to be glued and secured against any movement due to horizontal or vertical impacts. Cross-sectional •flow baffles shall not be used as substitutes for inlet or outlet tees. The inlet pipe elevation shall be no less than 2"nor more than 3"above the invert elevation of the outlet pipe. Inlet tee minimum of 10"length below water surface. The outlet shall be provided with a tee extending below the flow line 14"to 18". There shall be an air space of at least 3"between the tops of the tees and the inside of the tank cover. Inlet tees may be modified or a 6"riser on inlet cover may achieve this spacing. The tops of the tees shall be left open to provide ventilation or separate ventilation shall be provided. The outlet tee and compartment connection shall be equipped with a gas baffle. The effluent tee shall be fitted with a removable plastic outlet filter, as manufactured by Polylok Inc., model PL-120,Zebco, or approved equal. Provide manufacturer's maintenance data to homeowner and engineer. Homestead Inc. Page 1 9/5/04 CONSTRUCTION SPECIFICATIONS e. Septic tank should be inspected by the Owner or his representative for solids accumulation annually. When the sum of the sludge and scum layer approach 1/3 the net working volume of the tank(net of 16" total thickness),as measured at the center of the tank, the tank is due for pumping. Septic tanks shall be inspected and maintained in accordance with 310 CMR 15.300 and applicable local requirements. 3. Pump System Note: Not all plans require a pump and controls. Refer to the drawing to determine if this system is required. a. Pump chamber to be 1000 gallon concrete pump chamber unless otherwise specified elsewhere. Include one manhole access 24"diameter that terminates at or above ground surface with a steel manhole cover that can be secured. b. Pump to be used is specified in the pump calculation worksheet. c. Alarm system to be installed inside of dwelling unit in an accessible location. Alarm unit to have an audible and visible indicator of water level above the pump on level. Include a shut off or silence mode. Use CSI Controls model 5230 NEMA 4X Simplex or approved equal. d. Pump circuit and control circuit to be on separate and dedicated circuit breakers installed by a licensed electrician. 4. Distribution Box Note: Not all plans require distribution boxes. Refer to the drawing to determine if a d-box is required. a. The distribution box selected by the contractor shall conform with 310 CMR 15.232. Material of construction shall be concrete or plastic lined concrete. A 6"sump is required in the d-box. b. The distribution box shall be placed on thoroughly tamped and compacted sand or peastone a minimum of 6"thickness, and shall be leveled utilizing a water flow test. Speed levelers shall not be used on a new installation to obtain level and equal distribution flow,but should be installed after leveling is completed in case uneven settling occurs in the future. c. For inlet pipe slopes of 8%or greater,or where there is a pumped flow,the distribution box shall have an internal cast baffle or solvent welded pipe tee to reduce the velocity of the influent flow. An internal pipe "Y" is not acceptable. d. For systems with different sections of the leaching facility at different elevations,the first 2 feet of pipe out of the distribution box to be set dead level. 5. Piping a . Piping to the septic tank(the building sewer) shall be 4"diameter, PVC Schedule 40 or better. Slope pipe approximately 1/4" per foot length. b. All piping from the septic tank to the end of the system shall be 4" diameter, SDR-35 or better, except as noted on the drawings. Slope pipe approximately 1/8"per foot length. c. Pressure piping, if any,to be 1.5"diameter, 160 psi black poly pipe or 2"diameter PVC Schedule 40 pipe, as called for in the page titled Pump Calculations. 6. Leaching Facilities a. General: All leaching facilities to be of the size and location shown on the drawings. MI aggregate used Homestead Inc. Page 2 9/5/04 CONSTRUCTION SPECIFICATIONS in leaching facilities to be of double washed stone. Where the name brand Infiltrator is called for in this specification, other brands of the same dimensions may be substituted for the specified units. b. Leach fields(Infiltrator Systems): Arrange Infiltrator chambers on levelled ground. Parallel rows should be placed approximately 6"apart. Add end plates as per manufacturer's assembly directions. Fill spaces between rows with Title 5 sand to the level of the top of the chambers. c. Leach trenches (Infiltrator Systems): Assemble Infiltrator units as per manufacturer's requirements,as shown on the drawing Material used to level bottom of trenches, if required,to be Title 5 sand or washed stone. d. Leach galleries: cement boxes with internal cast or cast-in-place distribution piping. Box dimensions 12 to 19"tall x 8' long x 5' wide. Place on 6"double washed stone. Set each gallery level. Pack tops of horizontal seams between galleries with bitumen tape similar to the sealant tape used in septic tank seams. e. Breakout barrier, if shown on plan,to be minimum 40 mil thick continuous sheet. Install barrier vertically from bottom of excavation to height of top of leaching system. Seams of membrane material to be overlapped a minimum of 12 inches and glued with sealant as recommended by manufacturer. Material to be hypolon, low density polyethylene, buna-N rubber, EPDM, or approved equal. Backfill in lifts of no more than 6"to assure minimal deformation of membrane. If material is wider than the vertical distance to be covered as shown on the drawing, fold excess material over at the bottom of the trench. Inspection a. The contractor shall notify the System Designer a minimum of 48 hours in advance of the anticipated completion time for a final inspection. The system shall be essentially complete at the time of the final inspection,including all components in place,risers and covers installed,electrical components functional, etc. No installed system component shall be buried greater than 1"depth at the time of final inspection. The System designer shall verify the system was installed as designed and authorize the final grading. b. If the System Designer finds the system is not ready for inspection after being called, or if serious deficiencies are discovered,the System Designer must be notified to return to the job site when it is complete. There will be a charge to the installer of$50 for each return trip,payable directly to the System Designer at the time of the reinspection. 8. Final Grading a At conclusion of work, loam and seed all disturbed areas to perennial grass mixture. Added loam may be required for adequate grass growth. Mulch slopes with hay,burlap or netting to minimize erosion. b.. Surface over leaching facility shall be pitched so as to shed rainwater. c. Systems built late in the year, where the grass cover does not have a chance to establish itself,requires the contractor is to return after spring thaw and resurface final grades and add grass seed cover as required to equalize and stabilize all disturbed areas. Homestead Inc. Page 3 9/5/04 No. PT-20-315 Commonwealth of Massachusetts Northampton, Massachusetts FORM11 -SOIL EVALUATOR FORM Soil Suitability Assessment for On-site Disposal Performed By: Witnessed By Thomas S. Leue Ernie Mathieu. Town of h n No amDto Date: 8/25/04 Location Address or Lot No. 235 Coles Meadow Road, Northampton New or Repair Construction: Repair Owner's Name Address &Tel. # Steve Mongeon 235 Coles Meadow Rd. , Northampton, MA 01060 413 586-0254 ice Review Published Soil Survey Available: No❑ Yes rg Year Published: 1980 Publication Scale: 15840 Drainage Class' Well drained, 000d filter Soil Limitations: moderate effluent limitations, slope. Soil Type. CDC, Charton-Hollis fine sandy loam Soil Map Unit: 10 Superficial Geologic Report Available: Year Published Geologic Material (Map Unit) Landform Flood Insurance Rate Map: Above 500 year flood boundary No Within 500 year flood boundary No Within 100 year flood boundary No Wetland Area: National Wetland Inventory Map (map unit) Wetlands Conservancy Program Map (map unit) Current Water Resource Condition (}aGS): Month Range: Above Normal u Normal ® Below Normal ❑ Other References Reviewed: No ® Yes ❑ Publication Scale: • 3 Yes p Yes Yes DEP APPROVED FORM - 12/07/95 FORM 11-SOIL EVALUATOR FORM Page 2 of 3 Location Address or Lot No.: 235 Coles Meadow Road, Northampton Number: 315 On-site Review Deep Hole #: Date: Land Use: Vegetation: Slope (%). Distance in feet Open Possible Drinking 1 Soil Evaluation 930 AM Number: Time Surface Drainageway: Property PT-20- 315 8/25/04 Weather: Stones: Landform: Line: Other. clear lawn >150 no grass outwash plain 5% >150 from: Water Body: Wet Area: Water Well: >150 15 >150 Depth from Surface (inches) Soil Horizon Soil Texture (USDA) Soil Color (Munsell) Soil Mottling (inches) Other (Structures, Stones, Boulders, Consistency,% Gravel) 0 - 18 18 - 21 21 - 44 44 - 108 fill A B Cl fine sandy loam sandy loam loamy sand 7 .5YR 3/1 10YR 6/3 7.5YR 5/4 Mottles 2.5YR 5/8 no no 45 roots friable, 20% gravel friable >5% *MINIMUM Comments: Parent Material (geologic): Depth to Bedrock: Depth to Groundwater: Standing Water in Weeping from Pit Estimated Seasonal OF 2 HOLES REQUIRED AT EVERY PROPOSED DISPOSAL AREA 108 inches 45 inches the Hole: Face: High Groundwater: glacial till Depth NQ NO of Excavation: Depth: Depth: DEP APPROVED FORM-12/07A5 FORM 11-SOIL EVALUATOR FORM Page 2 of 3 Location Addressor Lot No.: 235 Coles Meadow Road. Northampton Number: On-site Review Deep Hole #: Date: Land Use: Vegetation: Slope (%): Distance in feet Open Possible Drinking 2 Soil Evaluation 9:30AM Number: Time Surface Drainageway: Property PT-20— 315 8/25/04 Weather: Stones: Landform: Line: Other: clear lawn >150 no grass outwash •lain 5% >150 from: Water Body: Wet Area: Water Well: >150 15 >150 Depth from Surface (inches) Soil Horizon Soil Texture (USDA) Soil Color (Munsell) Soil Mottling (inches) Other (Structures, Stones, Boulders, Consistency, %Gravel) 0 — 6 6 — 28 28 — 98 A B Cl fine sandy loam sandy loam loamy sand 7.5YR 3/1 10YR 6/3 7 .5YR 5/4 Mottles 2.5YR 5/8 no no 30 roots friable, 20% gravel friable >5% I * MINIMUM Comments: Parent Material (geologic): Depth to Bedrock: Depth to Groundwater: Standing Water in Weeping from Pit Estimated Seasonal OF 2 HOLES REQUIRED AT EVERY PROPOSED DISPOSAL AREA 98 inches 30 inches the Hole: Face glacial till Depth 3 of Excavation: Depth: Depth: NO High Groundwater: DEP APPROVED FORM-120755 FORM 11-SOIL EVALUATOR FORM Page 3 of 3 Location Address or Lot No. 235 Coles Meadow Road, Northampton Homestead Inc. No. 315 Determination for Seasonal High Water Table Method Used Depth observed standing in observation hole_ inches n Depth weeping from side of observation hole inches Depth to soil mottles 30, 45 inches El Ground water adjustment inches Index Well Number Adjustment Factor - Reading Date Index well level Adjusted ground water level Depth of Naturally Occurring Pervious Material Does at least four feet of naturally occurring pervious material exist in all areas observed throughout the area proposed for the soil absorption system? Yes If not, what is the depth of naturally occurring pervious material? Certification I certify that on June, 1995 I have passed the examination approved by the Department of Environmental Protection and that the above analysis was performed by me consistent with the required training, expertise and experience described in 310 CMR15.017. sal Signature: 1 Date: 8/26/04 DEP APPROVED FORM - 12/07/95 FORM 12 -PERCOLATION TEST Location Address or Lot No. 235 Coles Meadow Road Northampton Homestead Inc. #: 315 COMMONWEALTH OF MASSACHUSETTS Northampton, Massachusetts Percolation Test* Date: 8/25/04 Time: 10:02 AM Observation Hole # 1 2 3 4 Depth of Perc: (in.) 42 (inches) I Start Pre-soak: 10:02 AM End Pre-soak: 10:17 AM Time at 12": 10:17 AM Time at 9": 10:24 AM Time at 6": 10:39 AM Time (9" - 6"): 0:15 Rate - Min./Inch: • 0:05:00 * Minimum of 1 percolation test must be performed in both the primary area AND reserve area. Site Passes /Site Fails: Passes Performed By: Thomas S. Leue, Homestead Inc. Witnessed By: Ernie Mathieu, Northampton Comments: _ DEP APPROVED FORM - 12/07/95 235 Coles Meadow Road Northampton DESIGN CALCULATIONS Leach Bed System Structure: Single family home 3 bedrooms Design Flow: 110 gallons per bedroom per day Cale. Design Flow: 330 gallons per day Garbage Grinder: Not Allowed 1.0 factor Credit for Compost Toilet: 0% 0 gallons per day Total Design Flow: 330 gallons per day Percolation Rate: calculated 5.0 min. per inch Percolation Rate: design rate 5 min. per inch Loading Rate: Class I Soil 0.74 gallons/sq.ft./day Area required for infiltration: Variance Request for Field Reduction' Net Field Size: Infiltrator® System, bed configuration 446 sq. ft. 0% 446 sq. ft. Model Used: Standard Capacity Loading Length Width Invert Height sq.ft./In.ft. Inches Inches Inches Inches 4.72 75 34 6.5 12 Effective leaching area of Infiltrators: Number of Infiltrators® required: Bed Configuration: Homestead Inc. 29.5 sq. ft. per chamber 15.1 say: # chambers wide: 4 space between rows (in): 6 Total width: # chambers long: 4 Total length: Total Leaching area: 472.0 sq. ft. Net Calculated Capacity: 349 gallons per day Loading: 1-1-10 s 1 6 chambers 12.8 feet 25.0 feet 9/5/04 FORM 3A - CERTIFICATE OF COMPLIANCE No. Fee COMMOMWEALTV or MASSACIRISE is Board of Health, Northampton, MA CERTIFICATE OF COMPLIANCE Description of Work: ( X ) Complete System ( ) Individual Components The undersigned hereby certify that the Sewage Disposal System: Repair by: at: 235 Coles Meadow Road, Northampton has been installed in accordance with the provisions of 310 CMR 15.00 (Title 5) and the approved design plans/as built plans relating to application No. dated 9/5/04 . Approved Design Flow 330 (gpd). Installer: Designer: Inspector: Thomas S. Leue, Homestead Inc. Date: Date: Date: The Issuance of this permit shall not be construed as a guarantee that the system will function as designed. DEP APPROVED FORM 5/96