32A-088 (9) Commonwealth OfMassachusetts
City ofNorthampton Map: Block: Lot:
32A 088 001
In Accordance With The Massachusetts State Building Code, Section 110, This
CERTIFICATE OF INSPECTION
is issued to Hairston House
I Certify that I have Inspected the R3 Group Residence known as Hairston House
located at 25 GRAVES AVE, in the City of Northampton
The Means OfEgress Are Sufficient For The Following Number Of Persons:
BY STORY
Story Capacity Story Capacity
First Floor 3 Second Floor 16
BY PLACE OF ASSEMBLY OR STRUCTURE
Place of Assembly or Structure Capacity Location Place of Assembly or Structure Capacity Location
CI-2016-0067 03/25/2016 03/25/2017 G
Certificate Number Date Certificate Issued Date Certificate Expires Buildin Q#ii ' 1, Kyle J. Scott
*A COPY OF THIS CERTIFICA 17- JUST BE POSTED IN CLEAR I"IF. V NAAR ALL ENTRANCES **
212 Main Street-Rm 100*NORTHAMPTON,MA*Phone:(413)587-1240*Fax:(413)587-1272
MA#1452/CT#183893
845 Airport Industrial Park Road
Westfield, MA 01085
Phone 413-568-3547
Fire Alarm Inspection &Test Report
Customer: Gandara Center
Address: 25 Grave St, Northampton, MA
Date of Inspection: 5/5/2015
Inspector: Eric Dauplaise Nicet# 115243
Customer Contact: Joe
Location Phone Number: 413-322-7364
System Normal Upon Departure: YES
Panel Location: Basement
Panel Model: Edwards Firesheild 1OZn EFSC1004R
System Type: Conventional
Fire Department: Northampton Fire Department
Monitoring Company: Central Alarm 800-639-2066 Acct#33-7831
Zones: 5
Zone Type:
Heat Detector Type Chemtronics
Pull Station Type/Style Notifier NBG-12L
Smoke Detector Type/Style: System Sensor
Main Power: 120V 15Amp
Disconnect Location: Generator Panel CT#3
Auxiliary Power: (2) 12V 7AH 10/2014
Battery Voltage: 26.OV
Battery Drain Voltage Before: 26.OV
Battery Drain Test Voltage After: 25.5V
Procedure Used to Perform Voltage Drain Test? lin Accordance with NFPA 72 Chapter 14 Section 9
Remote Annunciator: lFront Hall
NFPA 72 2002 Edition Annual Requirements
YIN NA
Y=Satisfactory N=Unsatisfactory N/A=Not Applicable
FIRE ALARM CONTROL PANEL:
Are all the alarm zones labeled at the control panel? Y
Do all control panel lamps and LEDs illuminate? Y
Are control panel terminations secure? Y
Does an open wiring on initiating or indicating circuits cause panel to go into trouble? Y
Does the earth ground detection work properly? Y
Is the location of breaker feeding the alarm panel been identified? Y
Does the control panel go into trouble with loss of AC feed, or loss of battery power? Y
SYSTEM BATTERIES:
Are system batteries free of leaks or corrosion? Y
Are battery charging systems operating correctly and in the state of charge? Y
Are system batteries within manufactures replacement dates and/or proper current or voltage recommendations? Y
SYSTEM COMPONETS:
Have, smoke detectors been checked for sensitivity at the proper intervals? NA
Page 1 of 3
Are the smoke detectors sensitivity test results within the devices marked range or 4% obscuration light gray smoke? NA
Are all alarm notification appliances free of damage and operate per manufacture specifications? y
Have all magnetic door holders been tested, and found to be operating satisfactory? y
System annunciators are identified and operating correctly? y
SYSTEM SUPERVISION AND MONITORING:
Did the supervision station receive the correct initiating device within 90 seconds? y
Did the fire department receive a signal from the communicator or city box? NA
Location Device Type Type Izone# Results
Basement by Fire Alarm Control Panel Heat Detector R-0-R 1 1 OK
Basement Base of Stairs by Fire Alarm Control Panel Smoke Detector 2WB 1 OK
Basement Base of Stairs by Fire Alarm Control Panel CO Detector 5 OK
Basement by Exit Heat Detector 135 Degree 1 OK
Basement Left Side Base of Stairs CO Detector 5 OK
Basement Left Side Base of Stairs Smoke Detector SS-2400 1 OK
Basement Left Side Near Washer/Dryer Heat Detector Fixed Temp 1 OK
Basement Left Side Near Exit Pull Station Siemens Key 1 OK
Basement Right Side Near Exit Pull Station Notifier 1 OK
Basement Left in Food Storage Heat Detector Fixed Temp 1 OK
1st Floor Left Front Hall Pull Station 2 OK
1st Floor Left Front Hall Smoke Detector SS-2400 2 OK
1st Floor Left Living Room Heat Detector 135 Degree 2 OK
1st Floor Left Kitchen Heat Detector 135 Degree 2 OK
1st Floor Right Left Office Smoke Detector SS-2400 2 OK
1st Floor Right Rear Exit Hall Smoke Detector 2wB 2 OK
1st Floor Right Rear Exit Hall Pull Station 2 OK
1t Floor Right Staff Office Smoke Detector 2wB 2 OK
1st Floor Right Front Hall Pull Station 2 OK
1st Floor Right Front Hall CO Detector 5 OK
1st Floor Right Front Hall Smoke Detector SS-2400 2 OK
2nd Floor Left Front Hall Smoke Detector SS-2400 3 OK
2nd Floor Room 8 Smoke Detector Ss-2400 3 OK
2nd Floor Room 7 Smoke Detector SS-2400 3 OK
2nd Floor Room 6 Smoke Detector SS-2400 3 OK
2nd Floor Room 5 Smoke Detector ss-2400 3 OK
2nd Floor Top of Stairs Pull Station 3 OK
2nd Floor Top of Stairs CO Detector 5 OK
2nd Floor Left by Exit Smoke Detector SS-2400 3 OK
2nd Floor Right by Exit Smoke Detector Ss-2400 3 OK
2nd Floor Right by Exit Pull Station 3 OK
2nd Floor Right Restroom Heat Detector R-0-R 3 OK
2nd Floor Left Restroom Heat Detector R-0-R 3 OK
2nd Floor Right Top of Stairs Pull Station 3 OK
2nd Floor Right Top of Stairs CO Detector 3 OK
2nd Floor Smoke Detector 3 OK
1st Floor Kitchen Pull Station 2 OK
2nd Floor Right Front Hall CO Detector 5 OK
2nd Floor Right Front Hall Smoke Detector SS-2400 3 OK
Page 2 of 3
2nd Floor Room 4 Smoke Detector Ss-2400 3 OK
2nd Floor Room 3 Smoke Detector ss-2400 3 OK
2nd Floor Room 2 Smoke Detector SS-2400 3 OK
1st Floor Room 1 Smoke Detector SS-2400 2 OK
Attic Left Smoke Detector SS-2400 4 OK
Attic Right Smoke Detector Ss-2400 4 OK
Comments:
NO DEFICINCIES NOTED AT THIS INSPECTION
If you would like the deficiencies above repaired on a time and material basis please initial next to the repairs you would like
corrected,then print, sign, and date below. Request for repairs can be faxed or emailed to our office
RE: GANDARA CENTER 25 GRAVE ST, NORTHAMPTON, MA
Customer Printed Name: Authorized Signature: Date:
Page 3 of 3
Northampton Fire Department
26 Carlon Drive, Northampton, Massachusetts 01060-2373
d
Telephone: (413) 587-1032 Fax: (413) 587-1034
Assistant Chief: Duane A. Nichols
Deputy Chiefs: Stephen Vanasse, David Gagne,
Jon Davine and Timothy McQueston
Deputy Chief in charge of EMS: Christopher W. Norris
Brian P. Duggan Website: Htitp//: wwwAortharnptonrtPire.org
Fire Chief
Gandara Center April 23, 2015
147 Norman Street
West Springfield, MA 01089
ATTN: Joe Matines
I conducted a fire inspection at 25 Graves Ave, Northampton on April 23, 2015
and found no fire code issues that need to be corrected at time of inspection.
Please forward a copy of the latest annual fire alarm test to the fire department
as soon as possible.
If you have any questions or require additional information please contact me at
587-1241.
Y
Captain/Fire Inspector Larry Therrien
3 as 4 — 049
City of Northampton
Massachusetts �- {
NT OF BUILDING INSPECTIONS
Ma n Street • Municipal Building "ss +
' Northampton, MA 01060 sN1y 3rj~
8 2016 PERIODIC INSPECTIONS
Application Sent on March 9, 2016
PREMISE NAME: HARISTON HOUSE
PREMISE ADDRESS: 25 GRAVES AVE
OWNER(S) OF RECORD:
OWNERS: ADDRESS:
NORTHAMPTON, MA 01060
TELEPHONE NO: q13
z
NAME ON CERTIFICATE: HARISTON HOUSE
TYPE OF BUSINESS -�
S I� 016: 6-A AIM CEF)V a-
USE GROUP: A 3
INSPECTION FEE $150 334
Please complete and return this application to the Department of Building Inspections, 212 Main Street,
Northampton, MA 01060. We will contact you to arrange a time to inspect your property. If this information is
not correct, or if you no longer own this property, please note any changes at the bottom or on the back of this
form and return it to the building department. Feel free to contact us if you have any questions. We can be
reached at (413) 587-1240. hank you.
Applicant name:
Applicant Title:
l��xlGc
Telephone
�t3� any-sy
Preferred inspection time/date
Comments: rW i 1erd6— 3-L •—J