Loading...
32A-088 (9) Commonwealth OfMassachusetts City ofNorthampton Map: Block: Lot: 32A 088 001 In Accordance With The Massachusetts State Building Code, Section 110, This CERTIFICATE OF INSPECTION is issued to Hairston House I Certify that I have Inspected the R3 Group Residence known as Hairston House located at 25 GRAVES AVE, in the City of Northampton The Means OfEgress Are Sufficient For The Following Number Of Persons: BY STORY Story Capacity Story Capacity First Floor 3 Second Floor 16 BY PLACE OF ASSEMBLY OR STRUCTURE Place of Assembly or Structure Capacity Location Place of Assembly or Structure Capacity Location CI-2016-0067 03/25/2016 03/25/2017 G Certificate Number Date Certificate Issued Date Certificate Expires Buildin Q#ii ' 1, Kyle J. Scott *A COPY OF THIS CERTIFICA 17- JUST BE POSTED IN CLEAR I"IF. V NAAR ALL ENTRANCES ** 212 Main Street-Rm 100*NORTHAMPTON,MA*Phone:(413)587-1240*Fax:(413)587-1272 MA#1452/CT#183893 845 Airport Industrial Park Road Westfield, MA 01085 Phone 413-568-3547 Fire Alarm Inspection &Test Report Customer: Gandara Center Address: 25 Grave St, Northampton, MA Date of Inspection: 5/5/2015 Inspector: Eric Dauplaise Nicet# 115243 Customer Contact: Joe Location Phone Number: 413-322-7364 System Normal Upon Departure: YES Panel Location: Basement Panel Model: Edwards Firesheild 1OZn EFSC1004R System Type: Conventional Fire Department: Northampton Fire Department Monitoring Company: Central Alarm 800-639-2066 Acct#33-7831 Zones: 5 Zone Type: Heat Detector Type Chemtronics Pull Station Type/Style Notifier NBG-12L Smoke Detector Type/Style: System Sensor Main Power: 120V 15Amp Disconnect Location: Generator Panel CT#3 Auxiliary Power: (2) 12V 7AH 10/2014 Battery Voltage: 26.OV Battery Drain Voltage Before: 26.OV Battery Drain Test Voltage After: 25.5V Procedure Used to Perform Voltage Drain Test? lin Accordance with NFPA 72 Chapter 14 Section 9 Remote Annunciator: lFront Hall NFPA 72 2002 Edition Annual Requirements YIN NA Y=Satisfactory N=Unsatisfactory N/A=Not Applicable FIRE ALARM CONTROL PANEL: Are all the alarm zones labeled at the control panel? Y Do all control panel lamps and LEDs illuminate? Y Are control panel terminations secure? Y Does an open wiring on initiating or indicating circuits cause panel to go into trouble? Y Does the earth ground detection work properly? Y Is the location of breaker feeding the alarm panel been identified? Y Does the control panel go into trouble with loss of AC feed, or loss of battery power? Y SYSTEM BATTERIES: Are system batteries free of leaks or corrosion? Y Are battery charging systems operating correctly and in the state of charge? Y Are system batteries within manufactures replacement dates and/or proper current or voltage recommendations? Y SYSTEM COMPONETS: Have, smoke detectors been checked for sensitivity at the proper intervals? NA Page 1 of 3 Are the smoke detectors sensitivity test results within the devices marked range or 4% obscuration light gray smoke? NA Are all alarm notification appliances free of damage and operate per manufacture specifications? y Have all magnetic door holders been tested, and found to be operating satisfactory? y System annunciators are identified and operating correctly? y SYSTEM SUPERVISION AND MONITORING: Did the supervision station receive the correct initiating device within 90 seconds? y Did the fire department receive a signal from the communicator or city box? NA Location Device Type Type Izone# Results Basement by Fire Alarm Control Panel Heat Detector R-0-R 1 1 OK Basement Base of Stairs by Fire Alarm Control Panel Smoke Detector 2WB 1 OK Basement Base of Stairs by Fire Alarm Control Panel CO Detector 5 OK Basement by Exit Heat Detector 135 Degree 1 OK Basement Left Side Base of Stairs CO Detector 5 OK Basement Left Side Base of Stairs Smoke Detector SS-2400 1 OK Basement Left Side Near Washer/Dryer Heat Detector Fixed Temp 1 OK Basement Left Side Near Exit Pull Station Siemens Key 1 OK Basement Right Side Near Exit Pull Station Notifier 1 OK Basement Left in Food Storage Heat Detector Fixed Temp 1 OK 1st Floor Left Front Hall Pull Station 2 OK 1st Floor Left Front Hall Smoke Detector SS-2400 2 OK 1st Floor Left Living Room Heat Detector 135 Degree 2 OK 1st Floor Left Kitchen Heat Detector 135 Degree 2 OK 1st Floor Right Left Office Smoke Detector SS-2400 2 OK 1st Floor Right Rear Exit Hall Smoke Detector 2wB 2 OK 1st Floor Right Rear Exit Hall Pull Station 2 OK 1t Floor Right Staff Office Smoke Detector 2wB 2 OK 1st Floor Right Front Hall Pull Station 2 OK 1st Floor Right Front Hall CO Detector 5 OK 1st Floor Right Front Hall Smoke Detector SS-2400 2 OK 2nd Floor Left Front Hall Smoke Detector SS-2400 3 OK 2nd Floor Room 8 Smoke Detector Ss-2400 3 OK 2nd Floor Room 7 Smoke Detector SS-2400 3 OK 2nd Floor Room 6 Smoke Detector SS-2400 3 OK 2nd Floor Room 5 Smoke Detector ss-2400 3 OK 2nd Floor Top of Stairs Pull Station 3 OK 2nd Floor Top of Stairs CO Detector 5 OK 2nd Floor Left by Exit Smoke Detector SS-2400 3 OK 2nd Floor Right by Exit Smoke Detector Ss-2400 3 OK 2nd Floor Right by Exit Pull Station 3 OK 2nd Floor Right Restroom Heat Detector R-0-R 3 OK 2nd Floor Left Restroom Heat Detector R-0-R 3 OK 2nd Floor Right Top of Stairs Pull Station 3 OK 2nd Floor Right Top of Stairs CO Detector 3 OK 2nd Floor Smoke Detector 3 OK 1st Floor Kitchen Pull Station 2 OK 2nd Floor Right Front Hall CO Detector 5 OK 2nd Floor Right Front Hall Smoke Detector SS-2400 3 OK Page 2 of 3 2nd Floor Room 4 Smoke Detector Ss-2400 3 OK 2nd Floor Room 3 Smoke Detector ss-2400 3 OK 2nd Floor Room 2 Smoke Detector SS-2400 3 OK 1st Floor Room 1 Smoke Detector SS-2400 2 OK Attic Left Smoke Detector SS-2400 4 OK Attic Right Smoke Detector Ss-2400 4 OK Comments: NO DEFICINCIES NOTED AT THIS INSPECTION If you would like the deficiencies above repaired on a time and material basis please initial next to the repairs you would like corrected,then print, sign, and date below. Request for repairs can be faxed or emailed to our office RE: GANDARA CENTER 25 GRAVE ST, NORTHAMPTON, MA Customer Printed Name: Authorized Signature: Date: Page 3 of 3 Northampton Fire Department 26 Carlon Drive, Northampton, Massachusetts 01060-2373 d Telephone: (413) 587-1032 Fax: (413) 587-1034 Assistant Chief: Duane A. Nichols Deputy Chiefs: Stephen Vanasse, David Gagne, Jon Davine and Timothy McQueston Deputy Chief in charge of EMS: Christopher W. Norris Brian P. Duggan Website: Htitp//: wwwAortharnptonrtPire.org Fire Chief Gandara Center April 23, 2015 147 Norman Street West Springfield, MA 01089 ATTN: Joe Matines I conducted a fire inspection at 25 Graves Ave, Northampton on April 23, 2015 and found no fire code issues that need to be corrected at time of inspection. Please forward a copy of the latest annual fire alarm test to the fire department as soon as possible. If you have any questions or require additional information please contact me at 587-1241. Y Captain/Fire Inspector Larry Therrien 3 as 4 — 049 City of Northampton Massachusetts �- { NT OF BUILDING INSPECTIONS Ma n Street • Municipal Building "ss + ' Northampton, MA 01060 sN1y 3rj~ 8 2016 PERIODIC INSPECTIONS Application Sent on March 9, 2016 PREMISE NAME: HARISTON HOUSE PREMISE ADDRESS: 25 GRAVES AVE OWNER(S) OF RECORD: OWNERS: ADDRESS: NORTHAMPTON, MA 01060 TELEPHONE NO: q13 z NAME ON CERTIFICATE: HARISTON HOUSE TYPE OF BUSINESS -� S I� 016: 6-A AIM CEF)V a- USE GROUP: A 3 INSPECTION FEE $150 334 Please complete and return this application to the Department of Building Inspections, 212 Main Street, Northampton, MA 01060. We will contact you to arrange a time to inspect your property. If this information is not correct, or if you no longer own this property, please note any changes at the bottom or on the back of this form and return it to the building department. Feel free to contact us if you have any questions. We can be reached at (413) 587-1240. hank you. Applicant name: Applicant Title: l��xlGc Telephone �t3� any-sy Preferred inspection time/date Comments: rW i 1erd6— 3-L •—J