44-034 216 LOVEFIELD ST BP-2016-1122 GIS #: COMMONWEALTH OF MASSACHUSETTS Map:Block: 44-034 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Buildinq DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR PANELS BUILDING PERMIT Permit# BP-2016-1122 Project# JS-2016-001917 Est. Cost: $26000.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: ROOF DIAGNOSTIC'S SOLAR 93115 Lot Size(sq. ft.): 16770.60 Owner: DIEMAND RAYMOND&JOANNE Zoning: Applicant: ROOF DIAGNOSTICS SOLAR AT. 216 LOVEFIELQ ST Applicant Address: Phone: Insurance: 101 CONSTITUTION BLVD (781) 795-6422 O WC FRANKLINMA02038 ISSUED ON:3/23/2016 0:00:00 TO PERFORM THE FOLLOWING WORK.INSALLATION OF ROOF MOUNTED 7.15 KW SOLAR ARRAY POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Si2gature: FeeType: Date Paid: Amount: Building 3/23/2016 0:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner File# BP-2016-1122 APPLICANT/CONTACT PERSON ROOF DIAGNOSTICS SOLAR ADDRESS/PHONE 101 CONSTITUTION BLVD FRANKI IN02038(781) 795-6422 () PROPERTY LOCATION 216 LOVEFIELD ST MAP 44 PARCEL 034 001 ZONE THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION'CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid Typeof Construction: INSALLATION OF ROOF MOUNTED 7.15 KW SOLAR ARRAY New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 93115 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INF RMATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management /I Si of Building ficial Date Note: Issuance of a Zoning permit does not relieve a applicanit's burden to comply with all zoning requirements and obtain all required permits from Board of�ealth,Conservation Commission,Department of public works and other applicable permit granting author ties. i * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. Department use only City of Northampton Status of Permit: Building Department Curb Cut/Driveway Permit 212 Main Street Sewer/Septic Availability Room 100 Water/Well Availability �! Northampton, MA 01060 Two Sets of Structural Plans o� phone 413-587-1240 Fax 413-587-1272 Plot/Site Plans Other Specify APPLICATION TO CONSTRUCT,ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office Map Lot Unit 216 Lovefield Street jzone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Joanne and Raymond Demand 216 Lovefield Street Name(Print) Current Mailing Address: 413-584-8226 Telephone Signature 2.2 Authorized Agent: 101 Consitution Blvd Franklin, MA 02038 Name(Print) ,, Current Mailing Address _413-459-2018 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building 2000 (a)Building Permit Fee 2. Electrical 24000 (b)Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) 5. Fire Protection 6. Total= (1 +2+ 3+4 +5) 26000Check Number / This Section For Official Use Only Building Permit Number: Dlate Isisued: Signature: Building Comm issionedlnspector of Buildings Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage % Open Space Footage % (Lot area minus bldg&paved parking) #of Parking Spaces Fill: volume&Location A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO DONT KNOW W1 YES IF YES, date issued: IF YES: Was the permit recorded at the Registrar of Deeds? NO DON'T KNOW YES IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained , Date Issued: C. Do any signs exist on the property? YES NO Z IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES NO W1 IF YES,then a Northampton Storm Water Management Permit from the DPW is required. i SECTION 5-DESCRIPTION OF PROPOSED WORK(check all apo licable) New House Addition Replacement Windows Alterations) Roofing Or Doors Accessory Bldg. Demolition New Signs 11 ] Decks [ ] Siding[ ] Other Brief Description of Proposed Work: Installation of 26 PV solar panels on roof, 7.15 kW Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housing. IGOmolete the followina: a. Use of building : One Family--Z— Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PORMIT I, Joanne Demand as Owner of the subject property hereby authorize Joseph Wyld-Chirico to act on my behalf, in all matters relative to work authorized by this building permit application. Signature of Owner Date I, Joseph Wvld-Chirico as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Joseph V*Id-Chirico Print Name 3/18/2016 Signature of Owner/Agent Date SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder: Joseph WVId-ChiriCo 093115 License Number 11 HillrrPct Avp, Sppknnk MA 1712771 ti/1s412017 Address Expiration Date Signature Telephone 40174;-6684 9.Renlstered Home Improvement Contractor: Not Applicable ❑ Rnnf niannnstirs Snlar / NRC Hnmp Sniar 170279 Company Name Registration Number 101 Cnn.,;ftutinn RI ori, Franklin MA 09038 10/5/2017 Address Expiration Date Telephone 413-459-2018 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDA�IT(M.G.L.c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... � No...... ❑ 11. - Home Owner Exemption The current exemption for"homeowners"was extended toinclude Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license, provided that the owner acts as supervisor.CMR 780 Sixth Edition Section 108 3u Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures. A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such'homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature The Commonwealth of Massachusetts Department of IndustrialAccidents I Congress Street,Suite 100 Boston,MA 02114-2017 www.mass.gov1dia Workers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Leeibly Name (Business/Organization/Individual):Roof Diagnostics Solar/NRG Home Solar Address: 101 Constitution Blvd City/State/Zip:Franklin, MA 02038 Phone#:413-459-2018 Are you an employer?Check the appropriate box: Type of project(required): 1.M,7 I am a employer with 70 employees(full and/or part-time). 7. E] New construction 2.FJ I am a sole proprietor or partnership and have no employees working for me in 8. E]Remodeling any capacity.[No workers'comp.insurance required.] 9. El Demolition 1[j 1 am a homeowner doing all work myself.[No workers'comp.insurance required,]t 10 C]Building addition 4.[:]l am a homeowner and will be hiring contractors to conduct all work on my property. I will ensure that all contractors either have workers'compensation insurance or are sole I I.O Electrical repairs or additions proprietors with no employees. 12.F1 Plumbing repairs or additions 5.r7 1 am a general contractor and I have hired the sub-contractors listed on the attached sheet. 13.❑Roof repairs These sub-contractors have employees and have workers'comp.insurance.: 6.f_1 We are a corporation and its officers have exercised their right of exemption per MGL C. 14.[Z)Other PV Solar 152,§1(4),and we have no employees.[No workers'comp.insurance roquired.] L *Any applicant that checks box#I must also fill out the section below showing their workers'compensation Policy information. +Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such, 'Contractors that check this box must attached an additional street showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insmrance for my employees. Below is the policy and job site information. Insurance Company Name:Federal Insurance Co Policy#or Self-ins.Lic.4:0044727794-01 Expiration Date:4/1/2016 - Job Site Address:216 Lovefield Street City/State/Zip:Northampton, MA 01060 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152.,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy,of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of perjury that the information provided above is true and correct. Signature: Date: 3/18/2016 Phone#:413-459-2018 Official use only. Do not write in this area,to be completed by city or town official City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of IVIGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111 , S 150A. Address of the work: 216 Lovefield Street The debris will be transported by: NO UUMPSTER/ DEBRIS The debris will be received by: Building permit number: Name of Permit Applicant Joseph Wyld-Chirico 3/18/2016 Date Signature of Permit Applicant i •..i5 •: •.�1 ■.. STRUCTURAL ENGINEERS MF0F=P October 31,2015 Mr. Wisscm Taboubi NRG Solar 89F Washington Ave Natick,MA 01760 RE: Diemand Residence Solar Installation 216 Lovefield Street Easthampton MA 01027 Structural Assessment of Roof Framing MPP Project No: 15-3059 Dear Mr.Taboubi: Pursuant to your request,MPP Engineers has performed a limited structural evaluation of the roof framing at the above referenced site to determine if the roof has adequate capacity to support the proposed solar panels. Our analysis was based on the framing,information and configurations provided by NRG Solar. It is our understanding that the structural components of the existing roof framing are in good condition. It is further understood that all existing connections between the various roof framing members, including ceiling joists,collar ties and rafters are adequate to resist the current loading conditions and behave in the manner that a typical rafter and ceiling tie system is intended to behave prior to installation of the solar panels. Results Roofs—2,3 &4—adequate to support the proposed solar panels Roof 1 —NOT adequate to support the proposed solar panels • Provide sistering/reinforcement with new 2x10 member for every other rafter on the side where solar panels will be installed.Reinforcement shall be the full length of the rafter and be installed flushed with the ridge and extended down towards the eve. • Attach all reinforcements using(2) SDS Y4"x 3"long screws @ 12"O.C. or(2) 16D common nails @ 6"O.C. for full length of member. • If the reinforcement for the rafter cannot be installed as a single piece,it may be installed as two separate pieces provided there is a minimum'4 feet of lap. Structural Data and Code Information Our analysis was performed in accordance with the requirements of the 780 CMR 51.00:Massachusetts Residential Code which has adopted the 2009 International Residential Code with Massachusetts amendments.Per Table R301.2(1),the ground snow,load to be used for each town is in accordance with MPP Engineers,LLC 1 34 South Main Street, Suite D I Allentown,NJ 08501 609-489-5511 (office) I www.mppongineers.com 1 609-489-5916(fax) __ I Diemand Residence Solar Installation 216 Lovefield Street Easthampton MA 01027 Table R301.2(5). Similarly,the wind speed for each town is in accordance with Table R301.2(4).The roof framing was analyzed in accordance with Section R104.11 of the of the 2009 International Residential Code which allows for alternate approved design such as using the ASCE 7 code for determining actual snow loads on roofs(e.g. deriving flat or sloped roof snow loads from the specified ground snow load referenced in Table R301.2(5)). Wood members were analyzed and designed in accordance with the NDS 2005. The roof area for the solar panels of this residence is framed in a gable configuration with conventional 2x roof rafters. The existing roof structure is in good condition and is assumed to have two layers of asphalt shingles.The pertinent data is listed below: Roof 1 (7 Panels Total): Rafters: 2"x 10"(#2 Spruce-Pine Fir Assumed) Spacing: 16"O.C. Roof Slope: 0 Degrees Horizontal Projected Length of Rafter (Horizontal Projection): 19.00 feet Ceiling Joists: Present Roof Sheathing: Wood Boards and plywood sheathing Condition of Framing: Good Roof Covering: Asphalt Shingles Ground Snow Load,Pg: 40 PSF from Table R301.2(5)of Massachusetts Residential Code Importance Factor,I: 1.0 Exposure Factor,Ce: 1.0(Conservatively taken as Partially Exposed) Thermal Factor,Ct: 1.1 with Panels(Cold Roof) 1.0 existing condition(Warm Roof) Design Snow Loads On sloped roof: 28.00 PSF(Existing—Unobstructed Warm Roof) 30.80 PSF(New—Slippery Surface on Cold Roof) Roof 2(9 Panels Total Rafters: 2"x 8"(#2 Spruce-pine Fir Assumed) Spacing: 16"O.C. Roof Slope: 16 Degrees Horizontal Projected Length of Rafter (Horizontal Projection): 11.75 feet Ceiling Joists: Present Roof Sheathing: Wood Boards and plywood sheathing Condition of Framing: Good Roof Covering: Asphalt Shingles Ground Snow Load,Pg: 40 PSF from Table R301.2(5)of Massachusetts Residential Code Importance Factor,l: 1.0 Exposure Factor,Ce: 1.0(Conservatively taken as Partially Exposed) Thermal Factor,Ct: 1.1 with Panels(Cold Roof) Diemand Residence Solar Installation 216 Lovefield Street Easthampton MA 01027 1.0 existing condition(Warm Roof) Design Snow Loads On sloped roof. 28.00 PSF(Existing—Unobstructed Warm Roof) 27.72 PSF(New—Slippery Surface on Cold Roof) Roofs—3&4 00 Panels Total): Rafters: TRUE 2"x 6"(#2I Spruce-Pine Fir Assumed)—Roof-3 2"x 4" (#2 Spruce-Pine Fir Assumed)—Roof 4 Spacing: 24"O.C. Roof Slope: 33 Degrees Horizontal Projected Length of Rafter (Horizontal Projection): 7.08 feet(roof-03); 3.50 feet(roof-04) Ceiling Joists: Present Roof Sheathing: Wood Boards and plywood sheathing Condition of Framing: Good Roof Covering: Asphalt Shingles Ground Snow Load,Pg: 40 PSF from Table R301.2(5)of Massachusetts Residential Code Importance Factor,I: 1.0 Exposure Factor, Ce: 1.0(Conservatively taken as Partially Exposed) Thermal Factor,Ct: 1.1 with Panels(Cold Roof) 1.0 existing condition(Warm Roof) Design Snow Loads On sloped roof: 25.90 PSF(Existing—Unobstructed Warm Roof) 18.99 PSF(New—Slippery Surface on Cold Roof) Wind Speed: 90 MPH from Table R301.2(4)of Massachusetts Residential Code Exposure B Analysis Results: General Considerations ➢ Materials such as metal roofs or solar panels!are considered slippery surfaces. Since the solar panels are mounted slightly above the roof line,it would be conservative to consider a thermal factor Ct of 1.1,treating the panel surface as Ia cold roof rather than a warm roof.Based on the roof slope and considering it as a slippery surface,the snow load is reduced by 27%on roofs—3 &4 compared with the snow loading directly';on the existing shingled roof surface. This reduction equates to 6.91 PSF which essentially offsets the weight of the solar panels. The change in snow load on roof-02 is negligible. There is an increase in snow load on roof-01 by 10%which equates to 2.80 PSF. Gravity Loadin¢: Roofs—2, 3 &4—adequate to support the proposed solar panels Diemand Residence Solar Installation 216 Lovefield Street Easthampton MA 01027 Roof 1 —NOT adequate to support the proposed solar panels • Provide sistering/reinforcement with new 2x10 member for every other rafter on the side where solar panels will be installed.Reinforcement shall be the full length of the rafter and be installed flushed with the ridge and extended down towards the eve. • Attach all reinforcements using(2)SDS %4"x 3"long screws @ 12"O.C. or(2) 16D common nails @ 6"O.C. for full length of member. • If the reinforcement for the rafter cannot be,installed as a single piece,it may be installed as two separate pieces provided there is a minimum 4 feet of lap. It is our understanding that the panels will be installed using Unirac rail with L-feet(or equal)at approximately 48 inches on center(e.g. every two to three rafters). The leveling feet will be fastened directly into the existing joists with 5/16"diameter tag screws with a minimum embedment of 2.5". In addition, it is important that the leveling feet support locations be staggered between adjacent panels so that no single rafter supports more load than under the existing conditions. Wind Loading: Based on our calculations,the net wind loads imposed on the roof framing with an attachment spacing as indicated above will be less than the current loading on the roof framing. In addition,provided that the leveling feet are attached to the roof framing members in a typical staggered fashion,the overall wind loading imposed on the structure and the individual framing members will not be impacted to any great extent. If you have any questions regarding this matter,please feel free to contact my office at 609489-5511. We appreciate the opportunity to assist you with this evaluation. Sincerely, MPP Engineers,LLC Krishna J Allam E.I.T. F, `or ASHu G Ct No.4 X35 0' /STEF��,�wQ At �',� Ashutosh Patel,P.E. MA Prof Eng.Lie.No.48235 NEW SISTER RAFTER ON SIDE 6 PROPOSED Sank PANELS SEE REPORT FQt SIZE AND LENGTH EXISTDtG RIDGE BOARD tD SDPSON SDS k X 3'V®SCREWS!IE'O.C.Oft GD I"LTBDOI NABS D 6'O.C. FOR FULL LENGTH OF MEMBER EXISTING ROOF RAFTER/ \DUSTING ROOF TRUSS MEMBERS TRUES TOP QOtD WHERE OCCURS \DaSTING CEED_DIG.!Dist �n TYPICAL RAFTER/TRUSS SISTERING OPTION 1 —) N.T.S. NEW LAPPED slsrER RAFTER ON NE SDE Is PROPOSED SOLAR PALS B SEE REPM FIDt s�Alm LENGTH EXISTING ROM BOARD On ZCM ®SCREWS a tB' W 9DYN3(Y !. ._...-- ---------- iv-$E .. AIR FILL LENGTH OF MENDER NEW sa'IEIt RAFTER A"0 \ EXISTING RAFTER/ 4'-0'MIN LAP D4STDG ROOF RAFTER/ `EXRTIIG plff TItl6S NEMDETts TRUSS TOP CHORD TRUSS TOP CHM WHERE OCCM + e-e SISTERING LAP TOP VIEW -1 N.T.S. \ETasnm CEILOG JOIST �B TYPICAL RAFTER/TRUSS SISTERING OPTION 2—LAPPING SK-1 N.T.S. eee ■.■ STRUCTURAL REINFORCEMENT SKETCH NOTE' mom mo• NEW SISTERING ALL NEW WOOD SHALL BE DOUG—FIR NO. 2 OR BETTER also PLOT SCALE DATE DRAWN BY 1=0§=* N.T.S. 2015 ASF SK— I Diemand Residence 7.150 (DC) PHOTOVOLTAIC SYSTEM 216 Lovefield Street,Northampton MA 01027 7 LG275SIC-B3 c EXISTING 200A BUS EXISTING 200A TOP FED (N)JUNCTION BOX MAIN BREAKER SERVICE POINT(INSIDE) EXISTING SERVICE POINT &UTILITY METERING (OUTSIDE) SCOPE OF WORK: Q 6 LG275SIC-B3 SOLAR PANELSw 1 SE6000A-USOOONNR2 INVERTER N � �i> !A pN fnQ CO OOF TOP AND WALL MOUNTED ELECTRICAL EQUIPMENT ? O 0. (N)60A AC DISCONNECT 7 LG275SIC=83 EQLlIRED_PER CODE,AH3&FIRE DEPARTMENT 8 c W 240VNEMA-3R IotrTsrD� ONNECT TO 200A/ 200A MAIN SERVICE PANEL E m (N)SE600OA-USOOONNR2(240V)INVERTER rOTAL SYSTEM SIZE 7.15 kW DC Nz NTEGRATED DC DISCONNECT ARC FAULT �W SHEET INDEX: PROTECTED(OUTSIDE) -0� E1 - SITE PLAN E6 - DETAILS W 44 E2 - NOTES E7 - SINGLE LINES E3 - PROPERTY PLAN E8 - ELECT. NOTES E4 - ELEVATIONS E9 - SIGNAGE 10 LG275SIC-B3 E5 - ROOF PLAN E1O+ - CUT SHEETS VICINITY MAP 7 LG275SIC-63 N 0 1 tp art`re� Q .>t0 pj _SITE PLAN a +� SCALE:118°-1'-0" ° ETN e NOTE: ALL SCALES SET TO 11X17 SHEET SIZE E SOLAR PHOTOVOLTAIC SYSTEM NOTES: ABBREVIATIONS All materials,equipment,installation and work 9.Ail conductor exposed to weather shall be 22.Flexible,fine-stranded cables shall be A AMPERE / shall comply with the following applicable codes: listed and identified for use in direct sunlight. terminated only with terminals,lugs,devices or AC ALTERNATING CURRENT • 2012 IBC [NEC 690.31(B),310.8(D)] connector that are identified and listed for such use. AHJ AUTHORITY HAVING JURISDICTION U r BLDG BUILDING • 2012 IRC 10.The module conductors must be type USE-2 [NEC 690.31(F)] CONC CONCRETE •�- • 2011 NEC or listed for photovoltaic(PV)wire.(NEC 23.Connectors shall be of latching or locking type. CB COMBINER BOX • 2012 UMC 690.31(6)) Connectors that are readily accessible and operating cEC CALIFORNIA ELECTRICAL CODE CU COPPER • 2012 UPC 11.All conductors shall be marked on each end at over 30 volts shall DP DISTRIBUTION PANEL • 2012 IFC for unique identification. 24.Require tool to open and marked"Do Not DC DIRECT CURRENT • 2013 Building Energy Efficiency Standards 12.PV module negative shall be grounded.All Disconnect Under Load"or"Not For Current ECC EQUIPMENT GROUNDING CONDUCTOR LM EXISTING * Authority Having Jurisdiction grounded conductor shall be property color Interrupting".[NEC 690.33(0)&(E)(2)] FV FIELD VERIFIED • Fire Authority Having Jurisdiction identified as white.[NEC 200.6] 25.Equipment grounding conductor for PV modules GALV GALVANIZED t^1 13.PV system connected on the load side of the smaller than 6AWG shall be protected from physical GNGROUND GROUNDING ELECTRODE CONDUCTOR �.r► 1.Existing plumbing vents,skylights,exhaust service disconnecting means of the other damage by a raceway or cable armor.[NEC 690.46 HOG HOT DIPPED GALVANIZED outlets,ventilations intake air openings shall not source(s)at any distribution equipment on the &250.120(C)] I CURRENT be covered by the solar photovoltaic system. premises shall meet the followingNEC 26.Equipment roundin conductor for PV stems imp CURRENT AT MAX POWER [ grounding systems INVT INVERTER 2.Equipment.Inverters,motor generators, 705.12(D)]: without Ground Fault Protection(GFP)and installed Isc SHORT CIRCUIT CURRENT photovoltaic modules,photovoltaic panels,ac 14.Each source connection shall be made at a an non-dwelling unit must have ampacity of at least kVA KILOVOLT AMPERE photovoltaic modules source-circuit combiners g kw KILOWATT p dedicated circuit breaker or fusible disconnecting 2 times the temperature and conduit fill corrected Lew LOAD BEARING WALL and charge controllers intended for use in means.[NEC 705.12(D)(1)] circuit conductor ampacity.[NEC 690.45(6)] MIN. MINIMUM FP photovoltaic power systems shall be identified 15.The sum of the ampere rating of the 27.Fine stranded cables used for battery terminals, Mce MAIN CIRCUIT BREAKER ^E m o MSP MAIN SERVICE PANEL � a in and listed for the application. (NEC 690.4(D)) overcurrent devices in circuits supplying power to devices,and connections require lugs and terminals (N) (NEW) m S� 3.All outdoor equipment shall be NEMA 311 rated, the busbar or conductor shall not exceed 120% listed and marked for the use.[NEC 690.741 N3R NEMA 3R,RAiNTIGHT OUTSIDE RATED aW d c includingall roof mounted transition boxes and NEC NATIONAL ELECTRICAL CODE 4 of the rating of busbar or conductor.[NEC 28.Grounding bushings are required around_ NTS Tool TO SCALE a S E 705.12(D)(2)1 pre-punched concentric knockouts on the DC side of oc ON CENTER E `_=R f 4.All equipment shall be properly grounded and 16.The interconnection point shall be on the line the system(NEC 250.64 C) oCPD POLES-BREAKER PROTECTION DEVICE N Z bonded in accordance with NEC article 250. side of all round-fault protection equipment. 29.Grounding electrode conductor will be P POLES TBREAKER POLES- d 9 p 9 PL PROPERTY LINES S.All circuits connected to more than one source [NEC 705.12(D)(3)] continuous,expect for splices or joints at busbars PV PHOTOVOLTAIC shall have overcurrent devices located so as t0PVC POLYVINYL L CHLORIDE 17,Equipment containing overcurrent devices in within listed equipment RR ROOF RAFTER w provide overcurrent protection from all sources. circuits supplying power to a bus bar or (NEC 250.64 C) SBC SOLID BARE COPPER a [NEC 690.9(A)] conductor shall be marked to indicate the 30.All smoke alarms,Carbon monoxide alarms and SP SOLAR PLANE 6.All photovoltaic(PV)modules shall be mountedEL presence of all sources. [NEC 705.12(D)(4)] audible notification devices shall be listed and SSCH SCHHEEDDULEE on the roof.Additional equipment of the PV 18.Circuit breaker,if backfed,shall be suitable laded in accordance with UL 217 and UL 2034. SS STAINLESS STEEL i system shall be located outside the building near for such operation.[NEC 705.12(D)(5)] They will be installed in accordance with NFPA 72 PTC PRACTICAL TESTING CONDITIONS C C SWR! SAAR WATER HEATER the main electrical services.[NEC 690.14 ( )] 19.To minimize overheating of the busbar in and NFPA 720, (IRC 2013 8314&R31S). TYP TYPICAL ^ � 7.The utility interactive inverters shall panelboard,the panelboard main circuit breaker 31.2013 California Residential Code(CRC)requires UNCI UNLESS NOTED OTHERWISE automatically de-energize its output to the and the PV power source circuit breaker shall be that Smoke alarms and Carbon Monoxide Alarms be v VOLT I connected electrical production and distribution located at the opposite end of the retrofitted into the existing dwelling.These Smoke Ymp NAGE AT MAX POWER physically PPS 9 9• Voc VOLTAGE AT OPEN CIRCUIT network upon loss of voltage in the system and busbar. alarms are required to be in all bedrooms,outside w WATT shall remain in that state until the electrical 20.All the NEC required warning signs,markings, each bedroom,and at least one on each floor of the m production and distribution network voltage has and labels shall be posted on equipment and house.Carbon Monoxide alarms are required to be e been restored.[NEC 690.61] disconnects prior to any inspections to be retrofitted outside each bedroom and at least one t 8.Due to the fact that PV modules are energized performed by the Building Department inspector. on each floor of the house.These alarms may be whenever a light,PV contractor shall exposed to ht 9 21.Metallic raceways or metallic enclosures are solely battery operated if the Photovoltaic project disable the array during installation and service required wiring method for inside a building for does not involve the removal of interior wall and a by short circuiting,open circuiting,or covering PV system.[NEC 690.31(E)] ceiling finishes inside the home,otherwise,the the array with opaque covering.[NEC 690.18] alarms must be hard wired and interconnected. "OCCUPANCY TYPE: R-3 �� CONSTRUCTION TYPE: TYPE V-B "UNSPRINKLERED tos-ize 35 „TT-.50T 0 N � �tzsoz� 7aat�S Pia 9ano7 rn M MZ w N O PROJECT: PROPOSED TEN s,zE,s 7.155 oPAvm er Ts ararEN xvr 7.150 SOIAR PHOTO}�OLTAIC SYSTEM FOR: £ wF 15A1.r201e ° _ OAtrae Diemand Residence wrmm¢SE8000A.USMNNR2 Home "O° E5z s LESHr: 7ss2STORY #044-p34-O �p i Lcz ,c (413)564-82226ea 216 Lovofield Street, Northam n MA 01027 a 20'- 0" rn 25,- 4„ r D O z A O PROJECT: PROPOSED SYSTEM SIZE IS 7.150 IXUYM aY: TB 9YafEM av: 7.150 SOLAR PHOTOVOLTAIC SYSTEM FOR: 15 Mar 2016 n Unkae Diemand Residence nig' - .7, a :\ s MAR�r: pp YtypyTgiSE6000A-USOOONNR2 eua0e+a H7 2 STORY A Mp 44-034-001 Home i o (413)i584-8226 1 t ��.sr 4 MooulEs: Lcz7sslc-e' 216 Lovgfield Street, Northam ton MA 01027 d VIA 4 r SP# 1 PITCH AZIMUTH MATERIAL SPSQ Fi ARRAYSQ. RAFTER SPECS RAFTER MAX SPAN SHADE SP# 2 PITCH AZIMUTH MATERIAL SP SQ.F ARRAY SQ.FT RAFTER SPECS RAFTER MAX SPAN SHADE 0 112 ROLLED COMP.327.775 123.55 2'-10"@16 O.C. 19'-0" 77% 16 112 COMP. 319.29 158.85 2'-10"@ 16 O.C. 13'-2" 92% SP# 3 PITCH AZIMUTH MATERIAL SP SQ.FT ARRAY SQ.FT RAFTER SPECS RAFTER MAX SPAN SHADE SP# 4 PITCH AZIMUTH MATERIAL SP SQ.FT ARRAY SQ.FT RAFlER SPECS RAFTER MAX SPAN SHADE \ 33 112 COMP. 199.89 123.55 2'-10"@ 16 O.C. 8' S" 91% 33 112 COMP. 75.0 158.85 T-10"@ 16 O.C. 4'-2" 83% City of Northampton ' Building Department �J• Plan Review �z• 212 Main Street LM (D "M h ?- Northampton, MA 01060 C 0 O 0 84 ATTACHMENTS v N m o NEW PV CONDUIT TO BE RUN WITHIN y 5 N v, 0 @ 48"O.C. MAX.(TYP.) :a m 4'v2 ATTIC AND HIDDEN FROM VIEW. N h ALL ARRAYS �� A44. --------�NDUIT TO BE PAINTED To MATCH ��a g THE EXISTING SURFACE. � � a� a V�t r o O U W z N ROOF PLAN SCALE:1/8„-1,-O„ .. EQUIPMENT LEGENDE.� ” AL ACCESS os :co COMBINER �nn�AC DISCONNECT w/ DC DISCONNECT w/ LOAD CENTER w/ pP DISTRIBUTION PANEL ❑ WALL INVERTER w/ O DEDICATED Pv SERVICE POINT do LADDER H BOX BOX C�WARNING LABEL WARNING LABEL WARNING LABEL w WARNING LABEL WARNING LABEL M' SYSTEM METER OO UTILITY METERING E5 s� S�1 -6 s s2 SI,y S1 I p S2-8 SI.14 I2 S2,10 51,16 51.1 SI 2 S13 SI-S 51.4 St-6 SI.7 Z cn m N N ;0 z z U) co G) b � � m Z G7 G) m 01 PROJECT: PROPOSED SYSTEM SIZE i5 7.160 olUwx BY: Te sYerFw wM 7.150 SOLAR PHOTOVLTAIO SYSTEM FOR: OAfE: 15 Mer 2018 ru Unirac Diemant Residence (y��rg•� MwV£T: 4'@ srvERlecSE8000A-USOWNNR21 ! !\s iS -` ■ 2 STORY px 44-034-001 ..', xMaFcwr: µ (413)'684-6226 _s R MODULES; LG27wc.e3 216 Lovofiald Street, Northam n MA 01 q27 PV NODULE UNRAC SOIARNOUNT �' RNL WON ECO FASTEN GROUND WEB 3 L-FOOT NODULE CWP 5/16'EPDN BONDED W NODULE 304-76.8 SS WASHER COMP SHINGLES - .... L-102-3'BRADEP(OTHER- GREEN FASTEN RASIRNG: IS AYAIABIL� GF-1 ,B A. ECO-GFI-M-812 WRH . .(. GF-1 FISHING PaNO O ECO-CP-SO COMPRESSION BPI SQ P S NINE LAC�T WTH j,C INWIPETRRATa5FY LAO BOLT 5/16' APPROVED SEALANT (TO BE VOWED) (TO BE VERFIED) ,yam 1 STANDOFF DETAIL SCALE:N.T.S N c y 04 V) co E W EXISTING 200A BUS E °r EXISTING 200A MAIN BREAKER > 0 `�z° 120/240V 14)3W SUB PANEL (INSIDE) _ v — — E6000A-US000NNR2(240V)INVERTERS O I INTEGRATED DC DISCONNECT 0: r— I ARC FAULT PROTECTED a I II M I EXISTING 200A-/w 00A EISI UTILITY METER = I I�I�l l kNEW 240(OUTSIDE) ry 60A AC DISCONNECT 240V NEMA-3R (OUTSIDE) OUTSIDE ELECTRICAL ELEVATION DETAILa SCALE:N.T.S. E 6 A fir PROSOLAR MODULE ;- . CLAMP w/ 16" BOLT MODULE AND LOCK WASHER C PROSOLAR RAIL NUT 3/8-SS JAM NUT Z PROSOLAR RAIL & BOLT 9" STANDARD GALV. � N FLASHING WITH POLYURETHANE SEALANT Q -40 s os (E) ROLLED COMP ��2 $E ROOFING MATERIAL � o NZ (E) PLYWOOD FAST JACK STANDOFF W ROOF DECKING w/ 4 1/2" POST 3 1/2"x 5/16" STAINLESS STEEL DIA LAG BOLT (E) RAFTER STANDOFF DETAIL SCALE:N.T.S a ig ILe---. E6.1 SERVICE INFO INVERTER SPECS MODULE SPECS AMBIENT TEMPERATURE SPECS UTILITY COMPANY: MSP VOLTAGE: INVERTER:SE60D0A-US0O0NNR2 MODULE TYPE: QTY: WATTAGE: FRAME COLOR: AMBIENT TEMP RECORD LOW CONDUIT HEIGHT ROOF TOP ADDER ROOF TOP TEMP CONDUCTOR TEMP RATE NGRID 240 QTY:I LG275S1C-B3 26 275 BLACK 320 C22°C 5" 3.5" 22°C 54 °C MSP LOC: SERV.TYPE: MSP GROUND: VOLTAGE: WATTAGE: CEC EFF. 90°C NORTH WEST OVERHEAD (E)ROD 24W 6000 97.5% Voc:38.7 ISC:9.26 Imp:8.68 Vpmax:31.7 TEMP CORRECTION: ,76 ( .) PER 310.15(BX2)(a) WIRE OCP FOR WIRES CONNECTED TO BREAKERS OPTIMIZER SPECS MAX VOLTAGE TO BE GREATER THAN THE SIZE OF THE BREAKER. MAX (VOLTAGEx 990.7=MAX VOLTAGE) QTY:26 MAX STRING MAX OL19 69.7 VOLTS CELL:80 WATTAGE: v500 x i.2 = 000 TO 120/240V SE6000A—USOOONNR2 ISC:15A 11250 ,r�� p 3w (E) 200A TOP FED 60A INTERGRATED OC DISCONNECT L UTILITY SERVICE MAIN SERVICE PANEL UTILITY AC DISCONNECT ARC FAULT PROTECTED ES i PASS THROUGH "v 200A/2P 3 240V5NEMAS3R 3 600V NEMA-4X 1 String O INV 2 Of 10. + + 1 MODULES GROUNDED O WITH UNIRAC. O (E)LOADS + — EGC G I I G II I I I I G N -- • I PASS THROUGH 1 String N 600V NEMA-0 d co m I I of 16. o y ocyQ o , • I + 1 MODULES GROUNDED 3 '° c o E 35A/2P eGc c ' E P D N2 L2 t Z EGC/GEC U W GEC 0 lY a z (E) GROUND ROD r WIRE CONDUIT WIRE WIRE WIRE TYPE TEMP WIRE TEMP CONDUIT WIRE TERMINAL STRING OPERATING__STRING MAX MAX.SYSTEM GRND GRND WIRE TAG# QTY GAUGE: RATING: AMP DE-RATE: FILL: OCP: 75°C RATING: WATTAGE / VOLTAGE AMPS x NEC: =AMPS VOLTAGE SIZE TYPE OOPEN AIR 2 /10 PV WIRE 90C 40 x .76 x 1 = 30AA 35 A 2750 / 350 = 7.85 x 1.56 = 12.24A 500 #6 SBC m L m R S 1A OPEN AIR 2 q10 PV WIRE 90C 40 x 76 x 1 = 30.4A 35 A 4400 / 350 = 12.57 x 1.56 = 19.60A 500 #6 SBC ~ e (�2 1'EMT 4 118 THWN-2 90C 55 x .76 x 8 = 33.44A 50 A 7150 ! 350 = 20.42 x 1.56 = 31.85A 500 #6 1 SBC 9 f O THWN-2 2 116 THWN-2 90C 75 x 76 x 1 = 57.OA 65 A / = 25 x 1.25 = 31.25A 240p6 SBC a TM. E7 ELECTRICAL NOTES: 1. Installation shall meet all applicable safety and 13. Adequate spacing must be maintained between any performance standards established by the National Electrical plumbing sewer vents extending through the roof and the Code,the Institute of Electrical and Electronics Engineers,and underside of the photovoltaic panels(6"minimum accredited testing laboratories such as Underwriters recommended). Laboratories,and where applicable,rule of the Public Utilities 14. Pv equipment,systems and all associated wiring and 4t 1 Commission regarding safety and reliability,as well as meet interconnections shall only be installed by qualified persons all MID requirements. (nec 690.4 e). 2. Applicant shall make provision for installation of a MID 15. Photovoltaic system conductors shall be identified and production meter dedicated to measuring the output of the grouped.the means of identification shall be permitted generation(provide and install wiring and MID-specified meter separate color coding,marking tape,tagging or other socket and wiring). MID will provide the meter at no cost to approved means. (nec 690.4b) the applicant,/customer. 16. Conduit is 3.5"-5"above roof deck,used Ashrae Data 3. Arrangements utilizing transfer switches or alternative for conduit above 3.5"and below 12".Used chart 310.16 of to the arrangement shown and sheet E7 may be considered the 2011 NEC in 750 c table using ambent temp.of 51-550 upon submission of a diagram and explanation of the proposed deviation(s). MID engineering approval of equipment should be obtained prior to purchasing or installing any equipment. H N�o 4. AC disconnect switch shall be lockable,visible& M. W o w¢ accessible without obstructions such as gates,fences or walls. _-5---__--Ail modules will be grounded in accordance with code 138 os `- W and the manufacturer's installation instructions. -� E 6. Notify serving utility before activation of pv system. m N z 7. When a backfed breaker is the method of utility 0 interconnection,the breaker shall be installed at the U opposite end of the bus bar of the Main Breaker. W 8. Work clearances around electrical equipment will be 0 maintained per NEC 110.26(a)(1), 110.26(a)(2)& a 110.26(a)(3) 9. All exterior conduits,fittings and boxes shall be a rain-tight and approved for use in wet locations per NEC a 314.15. 10. All metallic raceways and equipment shall be bonded and electrically continuous. 21 11. All pv equipment,systems and all associated wiring and interconnections shall be installed by Qualified Persons. 12. The photovoltaic system conductors shall be identified and grouped.The means of identification shall be permitted m by separated color coding,marking tape,tagging or other approved means. NEC 690.4(b) E8 CAUTION: 4 r SOLAR ELECTRIC SYSTEM CONNECTED PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATIONS LABEL FOR MAIN SERVICECAUTION ' ;;' LABEL FOR AC DISCONNECT PHOTOVOLTAIC ARRAY DC DISCONNECT WARNING! POWER TO THIS BUILDING IS ALSO OPERATING CURRENTVOLTAGE: 20. A SUPPLIED FROM THE FOLLOWING OPERATING VOLTAGE: 5000 V THIS SERVICE ALSO SERVED MAX.SYSTEM VOLTAGE: 500 V BY A PHOTOVOLTAIC SYSTEM SHORT-CIRCUIT CURRENT: 15 A LABEL FOR MAIN SERVICE PANEL SOURCES WITH DISCONNECTS ' LABEL FOR DC DISCONNECT&INVERTER LOCATED AS SHOWN: N E WARNING! 0 PHOTOVOLTAIC POWER SOURCE T— ELECTRIC SHOCK HAZARD. SERVICE POINT& OPERATING AC VOLTAGE: 240 V DO NOT TOUCH TERMINALS. UTILITY METERING MAXIMUM OPERATING AC OUTPUT TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED AC DISCONNECT CURRENT: 25 AMPS IN THE OPEN POSITION, FOR UTILITY LABEL FOR MAIN SERVICE PANEL COVER OPERATION LABEL FOR COMBINER BOX PHOTOVOLTAIC ARRAY (N)INVERTEV(N)SOLARARRA-t ,.� 'a AC DISCONNECT c w (N)JUNCTION B X p p OPERATING CURRENT: 25 A CAUTION 840al THIS PANEL HAS SOLAR&UTILITY OPERATING VOLTAGE: 240 V $ A �c POWER. �g�. , LABEL FOR AC DISCONNECT E —__ ._ ALWAYS S iUT OFF BOTH BEFORE ___LABEL_ SERVICING. ° WARNING! ELECTRIC SHOCK HAZARD. (MID)AT THE MAIN SERVICE PANEL: s'830 DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND SOLAR PRODUCTION METER a LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. (MID)AT PRODUCTION METER a� LABEL FOR AC DISCONNECT WARNING! WARNING:PHOTOVOLTAIC POWER SOURCE �-- � ELECTRIC SHOCK HAZARD. WARNING LABEL SHALL BE PLACED ON INTERIOR AND 1F A GROUND FAULT IS INDICATED, EXTERIOR DC CONDUIT,RACEWAYS,ENCLOSURES,CABLE ASSEMBLIES,JUNCTION BOXES,AND DISCONNECTS.MARKING NORMALLY GROUNDED CONDUCTORS SHALL BE PLACED ON INTERIOR AND EXTERIOR DC CONDUIT, E MAY BE UNGROUNDED AND ENERGIZED RACEWAYS,ENCLOSURES AND CABLE ASSEMBLIES EVERY 10 FEET(3048 MM),1 FOOT OF TURNS OR BENDS AND WITHIN 1 LABEL FOR INVERTER FOOT ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES,WALLS OR BARRIERS. MARKING PV CIRCUIT CAUTION:SOLAR CIRCUIT DISCONNECT ( m LABEL FOR AC DISCONNECT CAUTION MARKING IS REQUIRED ON ALL INTERIOR AND EXTERIOR PV MARKING CONTENT AND FORMAT M N g THIS PANEL HAS SOLAR&UTILITY CONDUIT,RACEWAYS,ENCLOSURES,CABLE ASSEMBLIES,AND MARKING CONTENT:CAUTION:SOLAR JUNCTIMARKING SHALL BE PLACED EVERY 10 FEET,AT TURNS AND ON BOXES TO ALERT THE FIRE SERVICE TO AVOID CUTTING CIRCUIT THEM. WARNING! POWER. 16 INVERTER OUTPUT CONNECTION ALWAYS SHUT OFF BOTH BEFORE ABOVE AND/OR BELOW PENETRATIONS,AND AT ALL PV COMBINER -RED BACKGROUND DO NOT RELOCATE THIS SERVICING. AND JUNCTION BOXES. -WHITE LETTERING OVERCURREN7 DEVICE -MINIMUM 31W LETTER HEIGHT REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE -ALL CAPITAL LETTERS AT THE MAIN SERVICE PANEL: LABEL FOR MAIN SERVICE ENVIRONMENT(DURABLE ADHESIVE MATERIALS MUST MEET THIS -ARIAL OR SIMILAR FONT,NON BOLD REQUIREMENT) Eg LG Life's Good Meehanc[ rte �Electrxal P.Pertles(STC.) <n type V„' ... WIJS51<83 W]051 C-B3 W2051C.N .,//, - � YS Mono TN Cell vends L M um Pow et 5fC(PmPP) t ), �_ - f -x htPP Y°k•U.e(VP'PVJ oI' - ( .. .. Lm Cell ddnmaom. I E LG27551 C-E31 LG'<70>K-E3/LG2FSSIC-E3 •Prha�r op. vax.A(vs) - _. ., r. Module effciwwy(%) S1ncawwlodd rr 1 9DMtm9t mp.rKvrt(S). ,, L '- J is sbtic u.nd b.d J �.i -:,; M ryrt•m wlt.ge(V) - , ..1,- Wr9ht v r. t M ,ie fus,.V,4(AJ Po td JunPt,m bw it]w rg �U .. length of c�elec n0.'.- ,l av i]n .rz.,�r. •.• � e., n,A . ..., rte...,.c, OElertrratProperties(WCT*) - 1 _ Certifications and Warranty W2]5SIC-8311-3 . C.rofic.11w,clln Ptogrec-! IFC,.iZ .:,]a_lr _,'.,J••. Me.mum P--^ PPP) %•> f:. 1=. K 6"d Radun wwnntV I':e,., vdtdA(Voe) LL n �utp Pty(Pma Sh , "+v Effi my dV �eyy 7 m„erawm Coeffi N'o • - ,� DVE [ F P^wv ra w g tCO V -j `♦ V Vx .f.. QpN l0 1x `Oimens:ons(mm/1n) '- - lig (D N O �0Z Ch racterrtic Curves (� v _ Light and Robust 3 t5 C-ieat Installation O 77A �,,fi- .. .• N � 100%EL Tat Completed The ExtrePwver .. •.� ��{ �. �i ! r e 2: lot Reliable Warranties Positive Power Tolerance ,..., .; A[wut Wil El-I li u- c� MARI LG Life's floors ,,, ,, .,. ,. meet ru.ees. E10 d � 7 ) 1 r -e! oa r . Single Phase Inverters for North America solar, • • � • tU i[.RWA Ut 5{•µpRA Ui --A- iE aNA:is StInROA US 4fIMnA,A IG Ql RytS • SolarEdge Single Phase Inverters For North America SF30iUAC US!SEMOCA US,SE5000A USr'-_EGOOOA U:>` t c ii INRUT T. �_ .:. •, ,. , saw v w u� AM", HAW-11 IT--ARD EOMi*OAKEE INS"Ati Il ON$REC!FIfAT1(1N) d o � Ell sol1 ar=* eT solar - • . SolarEdge Power Optimizer Module add-on (ifi�l P"Al P401 P 0`.i F',J SolarEdge Power Optimizer PER °i° � ° PA„� ;} �M,60-tail (inr h%gMpowkl (fnr 9d¢e9 1Snr EO-cnR ifo,eh{n filnf Module Add-On Era nrfU: �,�.,,�, �TT1eti �.� _ n-ria n.naldn.I n,T.r,;,,aa a) 3 P-00 i P350 ' P404 r P405 P500 • i`)U+PU i DUA NC MRAI0N iItb VfY 6PI1 li'f R CONNFMD TO CPERAi$No SOi AREDGE!NVFRTi Ri 1: I c t,t n07 t)UftIN`ST ANDRY$P,,W r v,0,iit w4b;SS Ci NNEC'i D F REJM 5 0 ARt Do,mirit,f R C!R 50E ARTnT:F INVE R TE R 0'LI tTANOARV CC)M ITAN'F INVAIIATIUNS fC:Et(ATIVNN � a 7 a d N p d PV SYSTEM DESIGN USING A SIVGU nHASE THREE EASE SOtAffj f)Gi tNVTRTFR' g i E12 Greenrasten"GF1 -Procltlet C;uide Exploded Product View,Bill of Materials 14 Materials Needed for Assembly _ LM I Item No. Description of Material/Part Quantity 1 GF-1 Flashing 1 4 2 L-102-3"Bracket*(other options available) 1 ..PL. 3 5/16"EPDM Bonded 30418.8 SS Washer 1 4 Lag Bolt 5/16" 1 NowA �LL N • Required Tools ' Q Al.l _ ___._..� � V — _ E E y� LU Um 160 0 LU a b ' N $ b 877-854-3,347 Comntittedtothe SuppartofRenewabieDwrgy —UoFattcn o1a.'A11cmte,ntptute,2edunderco{ryrigfn,Allfight,reservfd,IG/1P13 E13 r C RA 'may, • MEw[wunclxt�rs UNI ( • A HILTI GROUP COMPANY SOLARMOUNT defined the standard in solar racking.New enhancements are designed ,"rh to get installers off the roof faster than ever before.Components are pre-assembled and optimized to reduce installation steps and save labor time,Our new grounding & bonding process eliminates copper wire and grounding straps to reduce costs.Utilize the microinverter mount with a wire management clip for an easier installation. ELIMINATE THE GRDUNDWIRE FRDM YOUR ARRAY LOSE THE COPPER & LUGS r enphase' r r. E N E R G Y W 'p pNt < s ^� O q w N :22 9 s� E v ! !' ! • I Sw� NZ �,I III I W 0 Ae a • � i; $ m T GET OFF THE ROOF FASTER THAN EVER BEFORE m OPTIMIZED COMPONENTS • VERSATILITY • AVAILABILITY * DESIGN TOOLS t E14