Loading...
32A-002 (2) 113 MARKET ST BP-2016-1059 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 32A-002 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: renovation BUILDING PERMIT Permit# BP-2016-1059 Project# JS-2016-001805 Est. Cost: $100000.00 Fee: $700.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: LEARY BUILDING COMPANY 104806 Lot Size(sq. ft.): 6882.48 Owner: MIRIAM JENNY M&GEORGE E Zoning. URC(117)/ Applicant: LEARY BUILDING COMPANY AT: 113 MARKET ST Applicant Address: Phone: Insurance: 1039 EAST MOUNTAIN RD (413) 336-2611 WESTFIELDMA01085 ISSUED ON:3/8/2016 0:00:00 TO PERFORM THE FOLLOWING WORK.-DEMO 3 STORY PORCH & REBUILD POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType• Date Paid: Amount: Building 3/8/2016 0:00:00 $700.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner File#BP-2016-1059 1J 1 01& APPLICANT/CONTACT PERSON HEIN JENNY M&GEORGE E ADDRESS/PHONE NORTHAMPTON01061 PROPERTY LOCATION 113 MARKET ST MAP 32A PARCEL 002 001 ZONE URC(117V THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid Tyoeof Construction: DEMO 3 STORY PORCH&REBUILD New Construction Non Structural interior renovations Addition to Existine Accessory Structure Buildina Plans Included: Owner/Statement or License 104806 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION PRESENTED: _I,Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management o ' ' Delay Si re of B it g ffic al Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of Planning& Development for more information. E?nVe%��[-Qomrnercial Building Permit May 15,2000 Department use only rt/ Ci IT09 ton Status of Permit: n Department Curb Cut/Driveway Permit \v Ni t1 , EF&etSewer/Septic Availability Room ` Water/Well Availability' Northampton, MA 01060 Two Sets of Structural Plans - �`� �� phone 413-587-1240 Fax 413-587-1272 Plot/Site Plans `J Other Specify APPLICATION TO CONSTRUCT, REPAIR, RENOVATE,CHANGE THE USE OR OCCUPANCY OF,OR DEMOLISH ANY BUILDING OTHER THAN A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Proaerty Address: This section to be completed by office 113 Market Street Map Lot Unit Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: ,T�Kq MIPLAAA �� �tJ�� � � lUOP�114AMP'lo,tj Name(Print) Current Mailing Address: ���/3) 6q S 3 21 Signature Telephone 2.2 Authorize -rent: �Eq -� �U34 E /l9a U�.aN 2A GJESTl=1 Njuk O o frS` Name(Print) Current Mailing Address: o Signature ` Teleph SECTION 3-E TIMATED C STRUCTION STS Item Estim d Cost(Dollars)to be Official Use Only completed b ermit applicant 1. Building ��+ (a)Building Permit Fee 2. Electrical J (b)Estimated Total Cost of �� Construction from 6 3. Plumbing -__ Building Permit Fee 4. Mechanical (HVAC) 5. Fire Protection 6. Total= 0 +2+3+4+5) eO 000 Check Number '26 This Section For Official Use Only Building Permit Number Date Issued Signature: Building Commissioner/Inspector of Buildings Date Version 1.7 Commercial Building Permit May 15,2000 .. SECTION 4-CONSTRUCTION SERVICES FOR PROJECTS LESS THAN 35,000 CUBIC FEET OF ENCLOSED SPACE Interior Alterations ❑ Existing Wall Signs ❑ Demolitioro Repairs❑ Additions ❑ Accessory Building❑ Exterior Alteration 10 Existing Ground Sign❑ New Signs❑ Roofing❑ Change of Use❑ Other❑ Brief Description Enter a brief description heK. ��" Of Proposed Work: 3 S(c�(� b r(� tSui.-� ;AC��2tin,Cti id tAJuS SECTION 5-USE GROUP AND CONSTRUCTION TYPE USE GROUP(Check as applicable) CONSTRUCTION TYPE A Assembly ❑ A-1 ❑ A-2 ❑ A-3 ❑ 1A ❑ A-4 ❑ A-5 ❑ 1B ❑ B Business ❑ 2A ❑ E Educational ❑ 2B I ❑ F Factory - ❑ F-1 ❑ F-2 ❑ 2C ❑ H High Hazard ❑ 3A ❑ I Institutional ❑ 1-1 ❑ 1-2 ❑ 1-3 ❑ 3B ❑ M Mercantile ❑ 4 0 R Residential ❑ R-1 ❑ R-2 ID R-3 ❑ 5A El S Storage ❑ S-1 ❑ S-2 ❑ 5B ❑ U Utility ❑ Specify: M Mixed Use ❑ Specify: S Special Use Specify: COMPLETE THIS SECTION IF EXISTING BUILDING UNDERGOING RENOVATIONS,ADDITIONS AND/OR CHANGE IN USE Existing Use Group: R'2 Proposed Use Group: R-2 Existing Hazard Index 780 CMR 34): Proposed Hazard Index 780 CMR 34): SECTION 6 BUILDING HEIGHT AND AREA BUILDING AREA EXISTING PROPOSED NEW CONSTRUCTION OFFICE USE ONLY Floor Area per Floor(sf) 1St 1,607 151 1,697 2nd 1,607 2nd 1,697 3rd 1,607 3rd 1,697 44, p/le 1,220 1,230 Total Area(sf) 6,041 Total Proposed New Construction (sf) 6,321 Total Height(ft) 33 Total Height ft 33 7.Water Supply(M.G.L.c.40,§54) 7.1 Flood Zone Information: 7.3 Sewage Disposal System: Public [Z] Private ❑ Zone Outside Flood Zone❑✓ Municipal ✓❑ On site disposal system❑ Version 1.7 Commercial Building Permit May 15,2000 SECTION 9-PROFESSIONAL DESIGN AND CONSTRUCTION SERVICES-FOR BUILDINGS AND STRUCTURES SUBJECT TO CONSTRUCTION CONTROL PURSUANT TO 780 CMR 116(CONTAINING MORE THAN 35,000 C.F.OF ENCLOSED SPACE) 9.1 Registered Architect: Mark O. Gelotte Architect, 70 Elm Street, Hatfield, MA 01038 Not Applicable ❑ Name(Registrant): 7804 Mark O. Gelotte Architect, 70 Elm Street, Hatfield,MA 01038 Registration Number 08/31/2016 �•��� (413) 247-9624 Expiration Date Signature Telephone 9.2 Registered Professional Engineer(s): Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date 9.3 General Contractor �� Not Applicable ❑ Company Na e: /� tW:l Responsible In Charge of Construction 103q E MOGN Address r Signatur L Telephone Version 1.7 Commercial Building Permit May 15,2000 8. NORTHAMPTON ZONING Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size 7195 7195 Frontage 50 50 Setbacks Front 30 30 Side L: 10-2 R: 13-5 L: 10-2 R: 13-5 Rear 52-2 47-7 Building Height 33 33 Bldg. Square Footage 1607 22.3 % 1697 23.5 Open Space Footage % (Lot area minus bldg&paved 2952 41 3042 42.3 parking) #of Parking Spaces 3 3 Fill: volume&Location A. Has a Special Permit/Variance/Finding �e ever been issued for/on the site? NO ® DON'T KNOW YES IF YES, date issued: ! _ IF YES: Was the permit recorded at the Registry of Deeds? NO ® DON7 KNOW YES IF YES: enter Book "`"'" Page and/or Document# B. Does the site contain a brook, body of water or wetlands? N0� DON'T KNOW ® YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained ® Obtained O , Date Issued: C. Do any signs exist on the property? YES ® NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES 0 NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing, grading, eation,or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES 0 NO R, IF YES,then a Northampton Storm Water Management Permit from the DPW is required. Version 1.7 Commercial Building Permit May 15,2000 SECTION 10-STRUCTURAL PEER REVIEW(780 CMR 110.11) Independent Structural Engineering Structural Peer Review Required Yes ® No O SECTION 11 -OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, C/J lu /Z(AM as Owner of the subject property hereby authorize Z to act on my behalf, in all matters relative tow rk authorized by this building permit application. `2- 2.11 l(r Signature of ner Date I, / i� as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. lam L&P�g---1 Print Name Sign re of Owner/ en Date SECTION 12-CONSTRUCTION SERVICES 10.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder: t"M LCA I?- License Number E, acs R" AAA oio�s— -z? ' l7 - Address Expiration Date r " 5 33G - Z �� Signature' J Telephone SECTION 13-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes No City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111, S 150A. Address of the work: //3 MAQlu� The debris will be transported by: MAP'K 6AO Wuj The debris will be received by: ?ja�yaiuk Building permit number: Name of Permit Applicant Date Signature of Permit Ap H ant I he Commonwealth of Massachusetts Department of IndustrialAccidents Office of Investigations 1 Congress Street,Suite 100 Boston,MA 02114-2017 www mass.govldia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information / Please Print Legibly Name (Business/Organization/Individual): LfOtLDttIG.T��L'l. Address: �n3 E. /ylo�►�r u � S�A� MA oivtsS� City/State/Zip: Phone#: -11-5 33& , Z&Il Are you an employer?Check the appropriate box: Type of project(required): 1.❑ I am a employer with 4. ❑ I am a general contractor and I employees (full and/or part-time). * have hired the sub-contractors 6. New construction 2.❑ 1 am a sole proprietor or partner- listed on the attached sheet. ❑ Remodeling ship and have no employees These sub-contractors have g• ❑ Demolition working for me in any capacity. employees and have workers' 9. ❑Building addition [No workers' comp. insurance omp' insurance. 10.❑Electrical repairs or additions required.] 5. We are a corporation and its 3.❑ I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions myself o work ' right of exemption per MGL y � workers' comp. 12.0 Roof repairs insurance required.] t c. 152, §1(4),and we have no 13.F-1 Other employees. [No workers' comp. insurance required.] *Any applicant that checks box#I must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. *Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Policy#or Self-ins. Lic. #: Expiration Date: Job Site Address: City/State/Zip: Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under t pains d naltie at the information provided above is true and correct. Si ature: � ''' Date: fZ- Phone Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1. Board of Health 2.Building Department 3.City/Town Clerk 4. Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: FOR 1153 The Commonwealth of Massachusetts DIA Use Only -C-\ Department of Industrial Accidents Office of Investigations - Dept. 153 5 t Congress Street,Suite 100,Boston,Massachusetts 02114-201 http://www.mass.gov/dia Invest./SWO ID#: AFFIDAVIT OF EXEMPTION FOR CERTAIN CORPORATE OFFICERS OR DIRECTORS Chapter 169 of the Acts of 2002 amended M.G.L. c. 152, §1(4) by adding the following paragraph: "This chapter shall be elective for an officer or director of a corporation who owns at least 25 percent of the issued and outstanding stock of the corporation. Notwithstanding section 46, these provisions shall apply only if the corporate officer provides the commissioner of industrial accidents with a written waiver of his rights under this chapter. Said commissioner shall promulgate regulations to carry out the purpose of this paragraph. Violations of this paragraph shall subject the corporation to the penalties set forth in section 25C." Pursuant to ivl.�T.1,. e 157, §1(4) as amended, 1/We the undercigrrecl officers of_ Leary Building, Inc. 1039 East Mountain Road, Westfield, MA 01085 (Name of Corporation and Address) each holding at least 25% of the issued and outstanding stock in said corporation, do hereby invoke the right to be exempt from the provisions of M.G.L. c. 152, §25A and therefore are not required to carry a workers' compensation policy covering the undersigned corporate officer(s) or director(s). I/We the undersigned do also waive any and all rights to make claims for benefits as defined in M.G.L. c. 152 for any injuries that may be sustained while in the employ of the above-named corporation. Further, I/we the undersigned do understand that, should the above-named corporation hire or have in its employ any employee(s) in addition to the undersigned corporate officer(s) or director(s), said corporation is required to obtain workers' compensation coverage for the employee(s) as prescribed by M.G.L. c. 152, §25A. I/We the undersigned have read and understand the statements and obligations as delineated abeve and I/we have checked the appropriate box below my/our name(s) indicating my/our desire to be eXMnpt.or not to be exempt from the provisions of M.G.L. c. 152. L= Signed "der.thp pains and I penalties of perjury: - - �' ._ Timothy A. Leary, president 07/15/2014 Sign ure Print Name&Title Date(mm/dd/yyyy)., . ❑✓ I w h to exero#se my right o texemption or ❑ 1 wish NOT to exercise my right of exemption r a f Signature Print Name&Title Date(mm/dd/yyyy) ❑ I wish to exercise my right of exemption or ❑ 1 wish NOT to exercise my right of exemption Signature Print Name&Title Date(mm/dd/yyyy) ❑ 1 wish to exercise my right of exemption or ❑ I wish NOT to exercise my right of exemption Signature Print Name&Title Date(mm/dd/yyyy) ❑ I wish to exercise my right of exemption or ❑ I wish NOT to exercise my right of exemption Note:ALL ELIGIBLE CORPORATE OFFICERS MUST SIGN. THERE CAN BE NO MORE THAN 4 SIGNATURES. Instructions on back. Form 153—712010 Initial Construction Control Document N To be submitted with the building permit application by a Registered Design Professional for work per the 8th edition of the Massachusetts State Building Code, 780 CMR, Section 107 Project Title: 113 Market Street Renovations Date: 2/16/16 Property Address: 113 Market Street,Northampton, MA. 01060 Project: Check(x)one or both as applicable: (X)-New construction (X)- Existing Construction Project description: Demolition of existing egress stair and unit balconies to 3 unit, mult-family dwelling. Re- construction of exit stair and balconies on 3 levels plus basement access. I Mark O. Gelotte, MA Registration Number: 7804 Expiration date: 8/31/16, am a registered design professional, and I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning': X-Architectural X- Structural Mechanical Fire Protection Electrical Other: for the above named project and that to the best of my knowledge, information,and belief such plans, computations and specifications meet the applicable provisions of the Massachusetts State Building Code, (780 CMR), and accepted engineering practices for the proposed project. I understand and agree that I(or my designee)shall perform the necessary professional services and be present on the construction site on a regular and periodic basis to: I. Review, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Perform the duties for registered design professionals in 780 CMR Chapter 17,as applicable. 3. Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work is being performed in a manner consistent with the approved construction documents and this code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 107. When required by the building official,I shall submit field/progress reports(see item 3.)together with pertinent comments, in a form acceptable to the building official. Upon completion of the work, I shall submit to the building official a `Final Construction Control Document'. Enter in the space to the right a"wet"or electronic signature and seal: AR O�-A �F� �A 0 N Phone number: 413 247-9624 No. 7804 , HATFIELD J� Email: mgelotte@markgelottearchitect.com MASS. SOF Building Official Use Only Building Official Name: Permit No.: Date: Note 1. Indicate with an `x'project design plans,computations and specifications that you prepared or directly supervised. If`other' is chosen, provide a description. Version 06 11 2013 1 Mark O. Gelotte Architect. 70 Fim Street Hatfield. Massachuscus 01038 413 247- 9624 mgelotteratrtarkgelottearchitect.cozn Code Review 2/17/2016 113 Market Street,Three Family Residence Northampton, MA Egress Stairs, Unit balconies Project Summary: The existing building consists of a 3 story, 3 family residential structure of wood construction. The building is un-sprinklered. The work consists of demolition of the existing egress stairs and residential unit balconies on the rear (east) side and re-construction of the egress stairs and residential unit balconies, including access to basement for tenant laundry. IEBC 2009 with Mass. Amendments IEBC CHAPTER 1 -SCOPE AND ADMINISTRATION 1015 Compliance Methods: Select a compliance Method Prescriptive Compliance Method: 101.5.4.0 investigation and Evaluation.As a condition of the issuance of a building permit the building owner shall cause the existing building to be investigated and evaluated in accordance with the provisions of this code. This may include: evaluation of design gravity loads, lateral load capacity, egress capacity,fire protection systems, fire resistive construction, interior environment, hazardous materials, and energy conservation. Chapter 3— Prescriptive Compliance Method 302.1 Additions: Stair& Balcony additions shall comply with IBC 2009 for new construction 303.1 Alterations: All alterations shall comply with IBC 2009 for new construction. IBC 2009 with Mass. Amendments IBC CHAPTER 3 - USE AND OCCUPANCY CLASSIFICATION 302.1 Classification of Structure Existing Use: R-2, Residential, Multi-Family(Building is unsprinklered) Proposed New Use: Same IBC CHAPTER 5 -GENERAL BUILDING HEIGHTS AND AREAS 503.1 Building Height and Area Limitations. Building height and Area Building Height: 33'. Building Stories: 3 stories. 1 Code Review for 113 Market Street,Northampton,Ma. Building Area: First floor existing: 1607 sf. First floor proposed 1697 sf. Second floor existing: 1607 sf. Second floor proposed 1697 sf. Third floor existing 1607 sf. Third floor proposed 1697 sf. Basement existing 1220 sf. Basement proposed 1230 sf. Total existing Area 6041 sf. Total proposed Area 6321 sf. Assuming Construction Type 5A, all height and floor areas are acceptable, See table 503 below. IBC Table 503 Allowable Building Heights And Areasa Building height limitations shown in feet above grade plane. Story limitations shown as stories above grade plane. Building area limitations shown in square feet, as determined by the definition of"Area, building," per story TYPE OF CONSTRUCTION TYPE I TYPE it TYPE III TYPE iV TYPE V A B A B A B HT A B HEIGHT(feet) UL 160 65 55 65 55 65 50 40 STORIES(S) GROUP AREA(A) S UL 11 4 4 4 4 4 3 2 R-1 A UL UL 24,000 16,000 24,000 16,000 20,500 12,000 7,000 S UL 11 4 4 4 4 4 3 2 R-2 A UL UL 24,000 16,000 24,000 16,000 20,500 12,000 7,000 S UL 11 4 4 4 4 4 3 3 R-3 A UL UL UL UL UL UL UL UL UL S UL 11 4 4 4 4 4 3 2 R-4 A UL UL 24,000 16,000 24,004 16,000 20,500 12,000 7,000 S UL 11 4 2 3 2 4 3 1 5-1 A UL 48,000 26,000 17,500 26,000 17,500 25,500 14,000 9,000 S-2 b, 5 UL 11 5 3 4 3 5 4 2 i A UL 79,000 39,000 26,000 39,000 26,000 38,500 21,000 13,500 For SI: 1 foot=304.8 mm, 1 square foot=0.0929 m`. A=building area per story,S=stories above grade plane, UL=Unlimited,NP=Not permitted. a.See the following sections for general exceptions to Table 503: 1.Section 504.2, Allowable building height and story increase due to automatic sprinkler system installation. 2. Section 506.2,Allowable building area increase due to street frontage. 3.Section 506.3, Allowable building area increase due to automatic sprinkler system installation. 4. Section 507, Unlimited area buildings. b. For open parking structures,see Section 406.3. c. For private garages,see Section 406.1. d. See Section 415.5 for limitations. IBC CHAPTER 6-TYPES OF CONSTRUCTION 602.1 Construction Classification. Buildings and structures shall be classified in one of the five construction types. See table 601 and 602 for fire resistance ratings. 602.5 Type 5A. Structure,exterior wails and interior walls are of any materials allowed by code. See Table 601. 2 1 Code Review for 113 Market Street,Northampton,Ma. IBC TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS(hours) TYPE I TYPE 11 TYPE Ill TYPE IV TYPE V BUILDING ELEMENT A B Ad 8 Ad 8 HT Ad 8 Primary structural frame' 3a 2a 1 0 1 0 HT 1 0 (see Section 202) Bearing Walls Exteriorf'g 3 2 1 1=2 2 1 2 1 0 Interior 33 2- 1 1 0 1 1 0 1/HT 1 0 Nonbearing walls and partitions Exterior See Table 602 Nonbearing walls and partitions 0 0 0 0 0 0 See Section 602.4.6 0 0 Interiore Floor construction and secondary 2 2 1 0 1 0 HT 1 0 members(see Section 202) Roof construction and secondary members(see Section 202) 1/z 1" 1°` 0` id°` 0 HT lb` 0 IBC TABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE`e Exterior Walls are required to hove 1 hour rating. (Refer also to section 705 and 707) FIRE SEPARATION OCCUPANCY DISTANCE=X TYPE OF OCCUPANCY OCCUPANCY GROUP A,8,E,F-2,1,R,S-2g, (feet) CONSTRUCTION GROUP Hr GROUP F-1,M,S-1g U X<5` All 3 2 1 IA 5<_X< 10 A 3 2 1 Others 2 1 1 IA,16 2 1 1" 10<_X<30 116,VB 1 0 0 Others 1 1 1d X>30 All 0 0 0 a. Roof supports: Fire-resistance ratings of primary structural frame and bearing walls are permitted to be reduced by 1 hour where supporting a roof only. b. Except in Group F-1, H, M and S-1 occupancies,fire protection of structural members shall not be required,including protection of roof framing and decking where every part of the roof construction is 20 feet or more above any floor immediately below.Fire-retardant-treated wood members shall be allowed to be used for such unprotected members. c. In all occupancies,heavy timber shall be allowed where a 1-'hour or less fire-resistance rating is required. d.An approved automatic sprinkler system in accordance with Section 903.3.1.1 shall be allowed to be substituted for 1-hour fire-resistance-rated construction, provided such system is not otherwise required by other provisions of the code or used for an allowable area increase in accordance with Section 506.3 or an allowable height increase in accordance with Section 504.2.The 1-hour substitution for the fire resistance of exterior walls sha))not be permitted. e. Not less than the fire-resistance rating required by other sections of this code. f. Not less than the fire-resistance rating based on fire separation distance(see Table 602). g. Not less than the fire-resistance rating as referenced in Section 704.10 3 Code Review for 113 Market Street,Northampton, Ma, IBC CHAPTER 10 MEANS OF EGRESS 1003.5 Elevation change.Where changes in elevation of less than 12 inches(305 mm)exist in the means of egress, sloped surfaces shall be used. Where the slope is greater than one unit vertical in 20 units horizontal (5- percent slope), ramps complying with Section 1010 shall be used.Where the difference in elevation is 6 inches (152 mm) or less,the ramp shall be equipped with either handrails or floor finish materials that contrast with adjacent floor finish materials. Exceptions: 1. A single step with a maximum riser height of 7 inches (178 mm) is permitted for buildings with occupancies in Groups F, H, R-2, R-3, S and U at exterior doors not required to be accessible by Chapter 11. "Exterior egress landing shall have a 7"max. rise at door. 1004.1 Design Occupant Load 1004.1.1 Residential areas,See table 1004.1.1 Table 1004.1.1 **Residential: All floor areas. 200s€. per occupant,gross. **6321 sf. divided by 200 = 31 occupants 1005. Egress Width: See 1008 Doors 1006.1 Means of Egress Illumination Required: The means of egress, including the exit discharge,shall be illuminated at all times that the building is occupied. 1006.3 Illumination Emergency Power: If power failure, emergency electrical system shall provide for the following. 1. Aisles and stairways 2. Corridors and exit passageways 3. Exterior egress components 4. Exterior landings 1008.1.1 Doors Size: Required egress doors shall provide 32" clear. **Will provide 36"new doors to the basement access. ** Section 104.10 Request for Modifications: Alternative to providing 32" clear opening doors from the 3 units. The existing doors leafs in the rear of the building,from each of the units to the rear balconies and the exit stairs are 32" wide. The work involves upgrading the doors to meet the fire resistance rating and separation requirements for an egress. The doors currently have a half lite configuration and let light into the kitchens. The upgraded doors are proposed to maintain the half lite configuration with fire rated,temperature rise assembly with a 1 hour rating. The alternative involves installing 32" wide new fire doors instead of the required wider 36" units. The Installation of 36" wide units would most likely involve re-structuring the new openings, possible balloon framing alterations for 3 stories and changes to the interior of the units,trim cabinets and electrical. 1008.1.2 Door Swing: Doors may swing in any direction with occupant load less than 50, 1008.1.5 landings: Level on each side of egress door. Exception:2. Exterior doors as provided for in Section 1003.5,See above 1003.5 1008.1.7 Thresholds: %" max 1008.1.9 Hardware height: 34"—48" 1008.1.10 Panic Hardware: Not required in occupancy less than 50, 1009.1 Stairway Width: Exceptions: 1.Stairways serving an occupant load of less than 50 shall have a width of not less than 36 inches 1009.2 Headroom: 80". 1009.4.2 Riser height and tread depth.Stair riser heights shall be 7 inches maximum and 4 inches minimum.The riser height shall be measured vertically between the leading edges of adjacent treads. Rectangular tread depths shall be 11 inches minimum. 1009.12 Handrails.Stairways shall have handrails on each side and shall comply with Section 1012. 4 f Code Review for 113 Market Street,Northampton,Ma. 1011.1 Exit Signs,Where required. Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Specified for basement and grade levels. 1013.2 Guard Height. Required guards shall be not less than 42 inches high. 1016.1 Exit Access Travel Distance TABLE 1016.1 EXIT ACCESS TRAVEL DISTANCE" OCCUPANCY WITHOUT SPRINKLER SYSTEM (feet) WITH SPRINKLER SYSTEM(feet) A, E, F-1,M,R,S-1 200 2SO' "Maximum distance to an exit from any space is: 65'. Meets Exit Access travel distance 1022.1 Enclosures required. Interior exit stairways and interior exit ramps shall be enclosed with fire barriers constructed in accordance with Section 707 or horizontal assemblies constructed in accordance with Section 712, or both. Exit enclosures shall have a fire-resistance rating of not less than 2 hours where connecting four stories or more and not less than 1 hour where connecting less than four stories. See also 707 "Walls and openings between units and the exit stair shall have a 1 hour fire resistance rating. 707.6 Openings. Openings in afire barrier shall be protected in accordance with Section 715.Openings shall be limited to a maximum aggregate width of 25 percent of the length of the wall,and the maximum area of any single opening shall not exceed 156 square feet(1S m`).Openings in exit enclosures and exit passageways shall also comply with Sections 1022.3 and 1023.5, respectively. 1022.6 Exit enclosure exterior walls. Exterior walls of an exit enclosure shall comply with the requirements of Section 705 for exterior walls. Where nonrated walls or unprotected openings enclose the exterior of the stairway and the walls or openings are exposed by other parts of the building at an angle of less than 180 degrees(3.14 rad),the building exterior walls within 10 feet(3048 mm) horizontally of a nonrated wall or unprotected opening shall have a fire-resistance rating of not less than 1 hour. Openings within such exterior walls shall be protected by opening protectives having a fire protection rating of not less than 3/4 hour. This construction shall extend vertically from the ground to a point 10 feet (3048 mm)above the topmost landing of the stairway or to the roof line,whichever is lower. *See also Section 705 for exterior walls below. 1026.6 Exterior ramps and stairway protection.Exterior exit ramps and stairways shall be separated from the interior of the building as required in Section 1022.1.Openings shall be limited to those necessary for egress from normally occupied spaces. See 1022.1 and 1022.6 above for required separation. Openings shall be limited. 705.5 Fire-resistance ratings.Exterior walls shall be fire-resistance rated in accordance with Tables 601 and 602 and this section. The required fire-resistance rating of exterior walls with a fire separation distance of greater than 10 feet shall be rated for exposure to fire from the inside.The required fire-resistance rating of exterior walls with a fire separation distance of less than or equal to 10 feet shall be rated for exposure to fire from both sides. "Exterior enclosure walls according to Table 601 and 602 shall have a 1 hour rating. 705.8 Openings. Openings in exterior walls shall comply with Sections 705.8.1 through 705.8.6. TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION FIRE SEPARATION DISTANCE (feet) DEGREE OF OPENING PROTECTION ALLOWABLE AREA" Unprotected, Nonsprinklered (UP, NS) 10%� 5 to less than 10'€ Unprotected, Sprinklered (UP, S)' 251 Protected (P) 25% Unprotected, Nonsprinklered (UP, NS) 15%' 10 to less than 15"f'g Unprotected,Sprinklered (UP,S)' 45% Protected (P) 45% 5 Code Review for 113 Market Street,Northampton,Ma. Unprotected, Nonsprinklered (UP, NS) 25% 15 to less than 20"g Unprotected, Sprinklered (UP, S)' 75% Protected (P) 75% UP, NS=Unprotected openings in buildings not equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. UP,S=Unprotected openings in buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. P=Openings protected with an opening protective assembly in accordance with Section 705.8.2. a.Values indicated are the percentage of the area of the exterior wall,per story. b. For the requirements for fire walls of buildings with differing heights,see Section 706.6.1. c. For openings in a fire wall for buildings on the same lot,see Section 706.8. d.The maximum percentage of unprotected and protected openings shall be 25 percent for Group R-3 occupancies. e. Unprotected openings shall not be permitted for openings with a fire separation distance of less than 15 feet for Group H- 2 and H-3 occupancies. f.The area of unprotected and protected openings shall not be limited for Group R-3 occupancies,with a fire separation distance of 5 feet or greater. g.The area of openings in an open parking structure with a fire separation distance of 10 feet or greater shall not be limited. 705.8 Openings "Unprotected Openings on North side shalt be limited to 15%of wall area. SECTION 715 Opening Protectives 715.4 Fire door and shutter assemblies.Approved fire door and fire shutter assemblies shall be constructed of any material or assembly of component materials that conforms to the test requirements of Section 715.4.1, 715.4.2 or 715.4.3 and the fire protection rating indicated in Table 715.4. TABLE 715.4 FIRE DOOR AND FIRE SHUTTER FIRE PROTECTION RATINGS REQUIRED ASSEMBLY RATING MINIMUM FIRE DOOR AND TYPE OF ASSEMBLY (hours) FIRE SHUTTER ASSEMBLY RATING (hours) Fire walls and fire barriers having a required fire-resistance rating of 1 hour { Shaft, Exit Enclosure and Exit Passageway walls 1 1 I i Other fire barriers 1 3/4 3 Exterior walls 2 1�J 1 3/ a 715.4.4 Doors in exit enclosures and exit passageways. Fire door assemblies in exit enclosures and exit passageways shall have a maximum transmitted temperature end point of not more than 450*F(250'C)above ambient at the end of 30 minutes of standard fire test exposure. SECTION 721 Calculated fire Resistance 721.6.3 Heavy Timber Fire Resistance *8x8 heavy timber beams supporting balcony structure meet the 1 hour fire resistance rating requirements for 5A construction. *2 %"T&G heavy timber decking meets the 1 hour fire resistance rating requirements for 5A construction. 6