Loading...
38B-006 (88) 4W SMITH COLLEGE 20 tv Campus Operations&Facilities 126 West Street Smith College Northampton,Massaµsetts 01063 TRANSMITTAL Date: March 21,2008 Project: Smith College Combined Heat and Power Projects To: Distribution PLEASE FIND [X]ATTACHED []UNDER SEPARATE COVER Item Description 1 Allied Testing Laboratories, Inc. Report#2423 - 1 - Compressive Strength Test(12/20/07) Report#2345 -2—Compressive Strength Test (12/26/08) Report#2370—2 - Compressive Strength Test(1/2/08) Report#2423 -2 - Compressive Strength Test (1/10/08) Report#2370—3 - Compressive Strength Test(1/29/08) [X] FOR YOUR RECORDS [X] FOR USE Distribution: Dave Chiovoloni,vanZelm Heywood&Shadford Dave Perkins,The Pike Company Tony Patillo,Building Commissioner,Northampton,MA Steven M.White GNBC 130 Elm Street PO Box 802 Old Saybrook,CT 06475 Original received an °copies distributed by: Gary J. Hartwell V 413-585-2441 Project Manager LF 413-585-2398 Campus Operations&Facilities E ghartwel@smith.edu Smith College 126 West Street Northampton,MA 01063 ALLIED TESTING LABORATORIES, INC. 115 St. George Road -Springfield, Massachusetts 01104 Phone (413) 736-1846 Fax (413) 736-1838 COMPRESSIVE STRENGTH OF CYLINDRICAL CONCRETE SPECIMENS -ASTM C39 REPORT NO: 2423 -1 CLIENT: Smith College PROJECT: Co-Generation, Northampton, MA LOCATION OF CONCRETE PLACEMENT: Ammonia Foundation REPORTED TO: Smith College Date: 12/20/2007 Concrete Class 4500 Mixture Weights per cubic yard Cement (lbs) Fine Aggregate (lbs) Coarse Aggregate (lbs) Water (gals) Admixture (oz) LABORATORY NO. W-422 Specimen No. A Slump ASTM C143 (in) 5.5" Air Content ASTM C173 or C231 (%) 5.5% Concrete Temp. ASTM C1064 690F Date Sampled 12/13/2007 Date Received 12/14/2007 Date Tested 12/20/2007 Age at Test (days) 7 Dimensions (in) 6 x 12 Area (sq in) 28.3 Wgt. of Specimen (lbs) 29.0 Total Load (lbs) 85,620 COMPRESSIVE STRENGTH (psi) 3030 Remarks: Respectfully submitted, ALLIED TESTING LABORATORIES, INC. 444a44� 4 W By: Richard Bellucci President MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S ALLIED TESTING LABORATORIES, INC. 115 St. George Road •Springfield, Massachusetts 01104 Phone (413) 736-1846 Fax (413) 736-1838 COMPRESSIVE STRENGTH OF CYLINDRICAL CONCRETE SPECIMENS -ASTM C39 REPORT NO: 2345-2 CLIENT: Smith College PROJECT: Co-Generation, Northampton, MA LOCATION OF CONCRETE PLACEMENT: Footing -Gas Compressor REPORTED TO: Smith College Date: 12/26/2007 Concrete Class 4500 4500 4500 4500 Mixture Weights per cubic yard Cement (lbs) Fine Aggregate (lbs) Coarse Aggregate (lbs) Water (gals) Admixture (oz) LABORATORY NO. W-119 W-120 W-121 W-122 Specimen No. A B C D Slump ASTM C143 (in) 4.5" 4.5" 4.5" 4.5" Air Content ASTM C173 or C231 (%) 5.3% 5.3% 5.3% 5.3% Concrete Temp. ASTM C1064 66°F 66°F 66°F 66°F Date Sampled 11/28/2007 11/28/2007 11/28/2007 11/28/2007 Date Received 11/29/2007 11/29/2007 11/29/2007 11/29/2007 Date Tested 12/5/2007 12/26/2007 12/26/2007 12/26/2007 Age at Test (days) 7 28 28 28 Dimensions (in) 6 x 12 6 x 12 6 x 12 6 x 12 Area (sq in) 28.3 28.3 28.3 28.3 Wgt. of Specimen (lbs) 28.5 28.6 28.7 28.5 Total Load (lbs) 81,180 140,660 141,910 140,610 COMPRESSIVE STRENGTH (psi) 2870 4980 5020 4970 Remarks: Respectfully submitted, ALLIED TESTING LABORATORIES, INC. By: Richard Bellucci President MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S ALLIED TESTING LABORATORIES, INC. 115 St. George Road -Springfield, Massachusetts 01104 Phone (413) 736-1846 Fax (413) 736-1838 COMPRESSIVE STRENGTH OF CYLINDRICAL CONCRETE SPECIMENS-ASTM C39 REPORT NO: 2370 -2 CLIENT: Smith College PROJECT: Co-Generation, Northampton, MA LOCATION OF CONCRETE PLACEMENT: Compressor Walls(ALL) REPORTED TO: Smith College Date: 1/2/2008 Concrete Class 4500 4500 4500 4500 Mixture Weights per cubic yard Cement (lbs) Fine Aggregate (lbs) Coarse Aggregate (lbs) Water (gals) Admixture (oz) LABORATORY NO. W-250 W-251 W-252 W-253 Specimen No. A B C D Slump ASTM C143 (in) 4.5" 4.5" 4.5" 4.5" Air Content ASTM C173 or C231 N 5.2% 5.2% 5.2% 5.2% Concrete Temp.ASTM C1064 61°F 61°F 61°F 61°F Date Sampled 12/4/2007 12/4/2007 12/4/2007 12/4/2007 Date Received 12/5/2007 12/5/2007 12/5/2007 12/5/2007 Date Tested 12/11/2007 1/2/2008 1/2/2008 Age at Test (days) 7 29 29 Dimensions (in) 6 x 12 6 x 12 6 x 12 6 x 12 Area (sq in) 28.3 28.3 28.3 28.3 Wgt. of Specimen (lbs) 28.5 28.5 28.6 Total Load (lbs) 78,185 106,210 116,205 COMPRESSIVE STRENGTH (psi) 2770 3760 4110 Remarks: *Due to low compressive strength, Cylinder No. W-253 Respectfully submitted, is being held for 56 DAY-TEST. ALLIED TESTING LABORATORIES, INC. By: Richard Bellucci President MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S ALLIED TESTING LABORATORIES, INC. 115 St. George Road -Springfield, Massachusetts 01104 Phone (413) 736-1846 Fax (413) 736-1838 COMPRESSIVE STRENGTH OF CYLINDRICAL CONCRETE SPECIMENS -ASTM C39 REPORT NO: 2423 -2 CLIENT: Smith College PROJECT: Co-Generation, Northampton, MA LOCATION OF CONCRETE PLACEMENT: Ammonia Foundation REPORTED TO: Smith College Date: 1/10/2008 Concrete Class 4500 4500 4500 4500 Mixture Weights per cubic yard Cement (lbs) Fine Aggregate (lbs) Coarse Aggregate (lbs) Water (gals) Admixture (oz) LABORATORY NO. W-422 W-423 W-424 W-425 Specimen No. A B C D Slump ASTM C143 (in) 5.5" 5.5" 5.5" 5.5" Air Content ASTM C173 or C231 N 5.5% 5.5% 5.5% 5.5% Concrete Temp. ASTM C1064 69°F 69°F 69°F 69°F Date Sampled 12/13/2007 12/13/2007 12/13/2007 12/13/2007 Date Received 12/14/2007 12/14/2007 12/14/2007 12/14/2007 Date Tested 12/20/2007 1/10/2008 1/10/2008 1/10/2008 Age at Test (days) 7 28 28 28 Dimensions (in) 6 x 12 6 x 12 6 x 12 6 x 12 Area (sq in) 28.3 28.3 28.3 28.3 Wgt. of Specimen (lbs) 29.0 29.2 29.0 29.2 Total Load (lbs) 85,620 153,770 148,285 156,895 COMPRESSIVE STRENGTH (psi) 3030 5440 5240 5550 Remarks: Respectfully submitted, ALLIED TESTING LABORATORIES, INC. By: Richard Bellucci President MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S ALLIED TESTING LABORATORIES, INC. 7r 115 St. George Road •Springfield, Massachusetts O1 104 Phone (413) 736-1846 Fax (413) 736-1838 COMPRESSIVE STRENGTH OF CYLINDRICAL CONCRETE SPECIMENS -ASTM C39 REPORT NO: 2370 -3 CLIENT: Smith College PROJECT: Co-Generation, Northampton, MA LOCATION OF CONCRETE PLACEMENT: Compressor Walls(ALL) REPORTED TO: Smith College Date: 1/29/2008 Concrete Class 4500 4500 4500 4500 Mixture Weights per cubic yard Cement (lbs) Fine Aggregate (lbs) Coarse Aggregate (lbs) Water (gals) Admixture (oz) LABORATORY NO. W-250 W-251 W-252 W-253 Specimen No. A B C D Slump ASTM C143 (in) 4.5" 4.5" 4.5" 4.5" Air Content ASTM C173 or C231 N 5.2% 5.2% 5.2% 5.2% Concrete Temp.ASTM C1064 61 OF 61 OF 61 OF 61 OF Date Sampled 12/4/2007 12/4/2007 12/4/2007 12/4/2007 Date Received 12/5/2007 12/5/2007 12/5/2007 12/5/2007 Date Tested 12/11/2007 1/2/2008 1/2/2008 1/29/2008 Age at Test (days) 7 29 29 56 Dimensions (in) 6 x 12 6 x 12 6 x 12 6 x 12 Area (sq in) 28.3 28.3 28.3 28.3 Wgt. of Specimen (lbs) 28.5 28.5 28.6 28.5 Total Load (lbs) 78,185 106,210 116,205 132,270 COMPRESSIVE STRENGTH (psi) 2770 3760 4110 4680 Remarks: Respectfully submitted, ALLIED TESTING LABORATORIES, INC. By: Richard Bellucci President MEMBER: A.S.T.M. / A.C.I. / A.W.S. / A.S.N.T. / M.C.I.B. / I.A.C.R.S