18-013 (12) FIXTURE TYPE #4 (LED - wired into nearest existing EWV WET LOCATION /VANDAL RESISTANT EXIT circuit) HOUSING BATTERY �� • IP66 RATED.420 Thick Die-Cast Aluminum • 6 Volt Ni-Cad Standard for 90 Minute Operation • High Impact,UV Stabilized Polycarbonate • Optional 120 Minute Ni-cad Battery is Lens. Available • Designed for Extreme Duty • Removable Chevrons ELECTRONICS • Perfect for Public areas where Outdoor/ • Low voltage Disconnect Vandalism is a Concern • AC Lockout • Damp,Wet,and Hose Down Location • Brown-out Protection Rated • 120-277/347 Volt Rated DIMENSIONS ILLUMINATION CODE CONFORMANCE& STANDARDS • LED Illuminated Red or Green Exits • UL 924 N.E.C, OSHA, N.FRA.101 r--C • CSA Listed s B D A L--E J JAI B C D E 14" 1 9"...16,2- 1 10" 1 4" ORDERING INFORMATION TYPICAL ORDER EXAMPLE: EWV R 1 LB WH RPK12 Prefix Letter Color Number of Faces Battery Housing Options EWV R-Red 1-Single LB-Less Battery WH-White RPK12-12"Pendant Kit G-Green 2-Double AC Only FL-Flasher WB-With Battery BK-Black AA-Audible Alarm Ni-Cad Only BH-Battery Heater(Specify:120 Or 277) IRT-Infrared Remote Test Switch XNB-Ni-Cad Battery With 120 Min Run Time Capacity d --__ _-- 36 j catalog# FIXTURE TYPE #4 (LED - wired into nearest existing circuit) FIXTURE TYPE #3 (LED - wired into nearest existing circuit) EX LED EXIT -- HOUSING MOUNTING F� • Two sizes • Universal Mount with Canopy -. • Injection Molded UL924 VO Flame Rated • Universal J Box Mounting Pattern Thermoplastic r SELF-TEST/SELF-DIAGNOSTIC - • Snap together Design OPERATION(SD2) - Universal Universal Face Design • The circuit continuously monitors the • Damp Location Rated operating condition of the AC power, • • Replaceable Chevron Arrows battery supply voltage,emergency lamp • continuity and charging circuit. EXIT • Available in White or Black • If a failure is detected,visual status will ILLUMINATION occur immediately via the multi colored LEDs.LED indicator(s)will illuminate until • L.E.D.Source.Available in Long Life,High fault has been corrected. Output Red or Green. DIMENSIONS • The SD2 also monitors the transfer • Fully illuminated 6"letters with 3/4"stroke circuit as well as performing automatic f—5.$°-1 --4.4_-7 0.75"�°'•'- y=� • Low Energy consumption with 2 watt red code compliant testing.The self test will 12-25" 1 7�' or 1 watt green LEDs operate the equipment in emergency mode five minutes every 28 days.Also,a ELECTRONICS 90 minute full-function test is performed 7 a" • 120/277 Dual voltage every six months. • Overload&Short Circuit Protection CODE CONFORMANCE& STANDARDS • Voltage Surge&Brown-out Protection • UL 924 on Emergency Units EX • Solid State Constant Current Charger • N.E.C. 14" ,�r,s°°( BATTERY • OSHA I.---13 _ • 6 Volt Ni-Cad Battery Standard on Non- • N.F.P.A.Life Safety Code 101 t Remote Units WARRANTY • 6 Volt Lead Calcium Standard on Remote Any component that fails due to U Capable ae nits / 10 p manufacturer's defect is guaranteed for 5 —, • Remote Capable Capacity up to 27 watts yrs from the time of shipment.The battery Optional. is prorated for 5 yrs.Warranty does not I • All Batter, Options Fully Contained within cover physical damage,abuse,or acts of 122,3,4.1 the Fixture God EX with Remote ORDERING INFORMATION/ p p TYPICAL ORDER EXAMPLE: EX R U WB WH SD2 Prefix Letter Color Number of Faces Battery Housing Options EX-Exit Sign R-Red U-Universal LB-Less Battery WH-White SD2-Self Test/Self Diagnostics (includes 2 face plates.back plate R12-12 Watts Remote Capacity G-Green and mounting canopy) WB-With Battery BK-Black R27-27 Watts Remote Capacity WG-(`) see wire guard chart PK1-1 Pendant Kit PK2-2 Pendant Kit PE12-12'Pendant Extension FL-Flasher AA-Audible Alarm FA-Flasher/Audible Alarm DLT-Down Light IF-Alarm Interface&Flasher IFA-Alarm Interface/Flasher/Audible Alarm VL-Vandal Lens SF-Special Sign Face 2CI-2 Circuit Input(not available on remote capable units) PG-polycarbonate guard(see chart) Project Name Fixture Type 2008 a�. Catalog # LSI INDUSTRIES IPIC- n., ., _ FIXTURE TYPE #3 (LED - wired into nearest existing circuit) FIXTURE TYPE #1 & #z (Pnospnorous - nu wii iiiy energy X1 t G10 Brite zero Unlike other exit signs, easy-to-install Eco Exit NCO 1CXlt,' PM 100 signs offer the only non-radioactive zero energy and zero maintenance solution on 100'viewing distance/1 for 1 electrical sign replacement the market. Green design and energy savings all rolled into one. Leading the industry in zero-energy egress systems, Jessup's new Glo Brite®Eco Exit signs utilize the latest photoluminescent technology to absorb and store ambient light. In the event of an emergency with blackout or smoky conditions this stored energy is immediately visible, creating a clearly recognizable, photoluminescent egress indicator.These innovative emergency egress signs reduce the risk of panic or injury during an evacuation, offering peace of mind while eliminating energy costs. Architect benefits Actual Eco Exit sign in dark. - LEED points qualified - Reduces cooling and emergency generator loads -Aesthetically pleasing designs Sign Options/Colors r -MesrantingDp ns -Multiple product solutions for every application tCe� igrai�or7 r Contractor benefits °- - Lower labor and material cost Mounting �? - No electrical to run or battery backup 2 — -Standard bracket options for easy mounting -Ceiling ".�✓ Building Owner benefits Rey i Dg p - Zero energy consumption -zero cost :Condth' $yHt � oinro�S - Zero maintenance- no bulbs, no battery replacement --------1 - No disposal cost Configurations - Movable if egress paths change Single-sided - Reduces overhead costs G,een -Double-sided - Non radioactive - Recyclable Other Models Available PF50 GloBrite Eco Exit signs are designed for either new P50 construction or retrofits in any application: 550 • office buildings • retail stores •warehouses and Block distribution centers • high rises • manufacturing facilities • apartments and living centers ti See all the GloBrite EcoExit sign solutions from LISTED TO ,/.,TI Jesse at www, lobrites stem.com U L 924 ; .Pi Jessup g Y us Going g; r'e­1qr2 d66 't- W Wk 00ensive FIXTURE TYPE #1 & #2 (Phosphorous - no wiring required) Exit Light Replacement Proiect Wal-Mart Store #2901 Northhampton, MA Scope of Work: This project consists of the replacement of 19 existing Tritium-style self- illuminated "EXIT"signs located throughout Wal-Mart Store #2901. See attached plan sheet E1 for specific locations of all fixtures to be replaced. 15 of these existing fixtures will be replaced with new, self-contained phosphorous fixtures manufactured by Jessup. These units require no wiring, and are identified on the Lighting Fixture Schedule on sheet E1 as Fixture Type #1 and/or#2. The remaining 4 replacement fixtures will be LED-type units, manufactured by LSI, and shown as Fixture Type #3 and/or#4 on the schedule. These fixtures will require wiring that will be tapped into the nearest existing egress lighting circuit. All existing circuits have been designed to handle future added capacity; therefore no new circuits will be necessary. The existing circuits will not be overloaded as a result of the additional load from these fixtures, which is minimal (10VA/fixture). If you have questions about this design, please contact the following at Henderson Engineers: Renee Jones: (913) 742-5503 _ 1 Harvey Ward: (913) 742-5309 1 j JUL 2 - 2008 w . 0 t0 B R R a r c h i t e c t u r e FAXABLE REVIEW RESULTS FORM In an effort to make the reporting of review results easier for officials, we are enclosing this courtesy fax sheet. If one of the check boxes below is applicable to the results of your review, feel free to simply check the box and fax back to our office at the fax number below. We will accept this fax sheet in lieu of an official letter from the reviewing jurisdiction. RESULTS OF REVIEW OF EXIT LIGHT REPLACEMENT: Building Department Project Location: Northampton, MA Wal-Mart Store Number: 2901 ❑ NOT APPLICABLE - Our review has determined that the changes contained within are not applicable to our local codes and/or ordinances. No further review or action required. ❑ APPROVED - Our review has determined the plans to be in compliance with applicable codes and/or ordinances. No further action required. F] NOT APPROVED - Our review has detected portions of the drawings to be in non-compliance with local codes and/or ordinances. A listing of deficiencies is: (please circle one below) Attached To Be Mailed ❑ REVIEW DELAYED - We are not able to begin our review of this change at this time. We anticipate the review to be complete by and we will contact you at that time. ADDITIONAL COMMENTS FOR ARCHITECT: *Signature of Reviewer/Building Official Date Please check the appropriate box above and fax back to BRR Architecture at: (913) 262-6913 www.brrarch.com 6700 Antioch Plaza,Suite 300,Merriam,KS 66204 MAIN 913-262-9095 FAX 913-262-9044 kansas city I bentonville I phoenix I tampa I miami BIRIR a r c h i t e c t u r e Architectural Plan Review Submittal July 1, 2008 Mr. Louis Hasbrouck Office of the Building Inspector Puchalski Municipal Building 212 Main Street Northampton, MA 01060 RE: Exit Light Replacement Plan Review Package Wal-Mart Store #2901 Location: Northampton, MA Hi, I am submitting the attached "Exit Light Replacement' construction documents for our Wal-Mart Store #2901. Wal-Mart is replacing the existing tritium exit signs in this store with new LED and Phosphorous exit signs. The material enclosed is in accordance with the requirements of your department as provided to us during recent phone conversations. Specifically, you will find the following documents enclosed: ❑ 2 sets of plans ❑ 2 sets of fixture cutsheets ❑ 2 scope of work descriptions ❑ 1 "Faxable Review Results Form" I will be contacting you by telephone soon to introduce myself and to confirm receipt of this mailing. If you determine that the submittal is incomplete for any reason, please contact me immediately so that I can prepare any additional mailing immediately. To aid us both, please consider me your key contact during the plan review process. I look forward to working with you through the plan review process! Sincerely, Dan Von Seggern Permit Expeditor Direct Phone: (913) 236-3427 Fax Line: 913-262-6913 Email: dan vonsegaern brrarch.com www.brrarch.com 6700 Antioch Plaza,Suite 300,Merriam,KS 66204 MAIN 913-262-9095 FAX 913-262-9044 kansas city I bentonville I phoenix I san francisco I tampa I miami B R R a r c h i t e c t u r e Fed-Ex Overnight Mailing Transmittal Requested By: Dan Von Seaaern Phone: 913-236-3427 Request Date: 3uly 1, 2008 MAIL TO: _ Office of the Building Inspector Puchalski Municipal Building Attn: Louis Hasbrouck 2008 212 Main Street Northampton, MA 01060 S k p S `: l' ��— Recipient Phone: 413-587-1240 Project Number: 96104486 Location: Northampton, MA Store #: 2901 Special Instruction: Mailing Consists of: ♦ 2 sets of plans (each set consists of two sheets - T1 and E1) ♦ 2 sets of fixture cut sheets ♦ 2 scope of work description letters ♦ 1 "Faxable Review Results Form" www.brrarch.com 6700 Antioch Plaza,Suite 300,Merriam,KS 66204 MAIN 913-262-9095 FAX 913-262-9044 kansas city I bentonville I phoenix I san francisco I tampa I miami