31A-053 Chuck Miller City of Northampton Assistant Commissioner and Zoning Enforcement In interior non-bearing studs holes not larger than 60%of a stud no closer than 5/8 to the edge, or holes in joist are a maximum 1/3 the depth not closer than 2"from the top or bottom or to any other hole. Notches are different. 7. Drilling or notching of more than 50%of the wall plate width of an exterior wall or load bearing partition requires a 16 GA 1%2" strap across the area and 6" beyond each side with 8- 10nd nails. 780 CMR R602.6.1 8. Where dryer ducts penetrate the wall they must be sealed with fire caulk. 780 CMR M504.2 9. Dryer ducts must terminate outside of the building, have a backdraft damper, cannot include a screen, and require 3' clearance from windows.780 CMR M504.4 10. Dryer duct transition is limited to 8' of aluminum flex, must be exposed, and the proper UL listing. 780 CMR M504.6.3 11. Dryer duct maximum equivalent length is 35' less 5' per 901 elbow or per manufacturer's specs. 780 CMR M502.6.4, no screwed connections use foil tape appropriate for the use. 12. Dryer ducts when concealed must have a permanent label or tag within 6' of the duct connection 780 CMR M502.6.5 13. Makeup air is required for dryers exhausting more than 200 CFM. 780 CMR M504.5 14. Makeup air is required for any exhaust hood over 400 CFM. 780 CMR M505.2 15. Fireplaces require all combustion air be provided from the exterior and below the firebox, duct work maintaining 1" clearance for 5'from the duct outlet for all fireplaces and airtight doors. 2009 IECC 402.4.3 16. Fire and draft stopping shall be completed before rough inspection.Typical locations, top (ceiling) and bottom (floor) plates,soffits, and every 10'within enclosed cavities. 780 CMR R302. 17. Energy aspects shall comply with the stretch energy code. 780 CMR Appendix 115AA or 2009 IECC. a. An initial HERS evaluation is required including insulation levels anticipated. b. A final HERS evaluation confirming code requirements have been met including duct testing. c. A signed copy of the Thermal Bypass Checklist. d. Energy information including mechanical equipment posted on the electric panel. e. Remodeling and Additions can be completed in accordance with IECC 2009 with Energy Star Windows and the Thermal Bypass Checklist. Duct blast testing when practicable. f. All band joist insulation must be enclosed within an air tight cavity,which you must create. 18. Unvented attic assemblies. Hot roofs are allowed, but have specific requirements 780 CMR R806.4. 19. Smoke and CO detectors as required. 780 CMR R314 and R315. a. Smokes in each bedroom,within 10' of a bedroom door, and at the bottom of a stair leading to a finished floor above. b. CO within 10'of bedroom doors, at each level,for every 1500 sqft,(plumbing code in the mechanical room) Except if there are no fossil burning fuels or attached garage. c. Heat detector in attached garage, and other large unfinished unconditioned spaces. 20. Clearances above gas stoves and cook tops burners is 24" to non-combustible or per the upper manufacturer's requirements, else 30" to combustibles. Relevant items must be submitted to the building department for approvals before inspections and or Certificates of Occupancy can be issued. Feel free to call if you have any questions. My telephone number is 587-1240 and office hours are Monday through Friday,8:30 am to 4:30 pm, excepting we close for walk-ins at 12:00 noon on Wednesdays. My email address is: cmiller(d_)northamptonma.gov Thank you for your cooperation on these matters. City of Northampton Massachusetts -. DEPARTMENT OF BUILDING INSPECTIONS 212 Main Street • Municipal Building . �. Northampton, MA 01060 INSPECTOR James Phaneuf November 23, 2015 74 Old Stage Road West Hatfield, MA 01088 Subject Location: 234 Crescent Street, Northampton Map Block: 31A-053 Mr. Phaneuf, Your building permit application with plans dated 11-9-15 has been approved as drawn and per this memo. All work must meet all applicable codes whether noted or not included within this memo. Please follow up on the following items: These items will need to be accomplished as the project moves forward and before rough inspections; 1. Beware any windows located in a hazardous areas must be tempered. 2. Beware any window opening within 24"of the FF and more than 72"AFG requires a restrictor. 3. Smoke, Heat and CO detectors throughout the structure to current building codes where possible. 4. An emergency escape window is required within every bedroom, basement and walk-in attic where possible. 5. An air barrier is required between the tub and the wall cavity, a solid member sealed in place. Note:The 2012 IECC with MA amendments is the non-stretch energy code and the new Stretch Code expected to be completed in 2015. As of August 4th 2011 the 8th Edition MA code is the 2009 IRC with MA amendments. In the following are some generic requirements which seem to be problematic. This is not intended to be comprehensive, nor is it a substitute for purchasing and reading the MA codes. Read only international codes are available on line at http://publicecodes.cyberregs.com/icod/one must also consider the MA amendments to these codes which can be found at www.mass.gov/dps/bbrs . The current relevant building codes are: 2009 IBC,2009 IEBC, 2009 IMC, 2009 IRC, 2009 or 2012 IECC,AA115, MA amendments. 1. Emergency escape is required out of every basement whether habitable or not, each bedroom and walk- in attics. 780 CMR R310.1 2. Hazardous glazing locations, within 24" of a door, or within 60" of a stair, or across from hot tubs,spas, bathtubs within 60" if not 60" above the walking surface, and other locations. 780 CMR R308.4 3. Windows over 72" above grade with the opening less than 24 above the finished floor shall meet the 4" sphere rule. Order restrictors. 780 CMR R612.2 4. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9", maximum riser 8%", maximum overall variance for the run is 3/8",4" sphere rule on risers except where the total rise is 30" or less 780 CMR R311.7.4.3 Exception,4 3/8" on balustrade, 6" in the triangle. Graspable rail 1 V minimum and 2" maximum rail, height minimum 34" maximum 38", required for 4 or more risers. Landing to landing constitutes a new run. Minimum 6'8" ceiling height from nosing. Rails must be continuous and returned to the wall if not to newel post. 780 CMR R311.7. 5. Guards 36" minimum height above walking surface, a bench is a walking surface, required for more than 30" above floor or grade within 36",4" sphere rule.780 CMR R312.1. 6. Educate the plumber and electrician about maximum notch and hole sizes, and placement. 780 CMR R502.8 and R602.6. In bearing studs holes not larger than 40%of a stud no closer than 5/8 to the edge, � RZ) r-Lo d)0— SECTION ^ t2 ° E w ° N N U VN All roof area to have maximum dense pack Cellulose To prevent Ice dams from forming over cold eave overhangs. I.the roof insulation will stop at the exterior wall plane in rafters n — ! and theroofwiube leftunintilatedonlythem, PORCH CEILING AREA BELOW Z 2 ° o r \� 2.spray foam sealant to be on back of the facia to all of the soffit NIC insulation in floor area and then onto the rafter plate to keep exfiltration at minimum. - < O ^ F u ATTIC STORAGE m E N _ 1,1 unisulated roof area 04 celulw /2,)foam sealed facia,soffit, ° i - /Insulation rim joist down to wall plate below interior roof area I existing I new walls w max \ EX G NIC �/ .-. +- > EXISTING FINISHED ROOM open FINISHED RM v V U U w ATTIC STORAGE Approxoma:e location for the / +- p existin \ 4 new posts to the flat roof Pram / 4^ U g up from the two bearing wafts for / S H knee �l I \ stopping deflection in walls spread - f� ---- --- ---- G Q < walls � - — — SECTION ATFINISHEDROOM!�blockoNinsul EXISTING OVER THE PORCH I cellulose insw I flat roof frame ADDENDA#'1 I � I— — — �—El I I ONLY REACTIVE EXG I SCHEME All roof area to have maximum dense pack Cellulose PLUMBING FIXTURES r relocate door BATH RM NfC new wall to HALL \ NIC I DORMER 2 PCH enlargebatHrm NIC AT qN `�'` restore ezg tub J \s ylite _ remove sta�Irs 3 N36',infili floor an match finish ALT cefuloge PATCH ~ 1w. _� ly Z ,insulation ._interor roof area „q i^ -- - s -- Z Q �\ install new o have 1 2 foil facg,__ �, SECTION urethane under I stain and theGW6 railings HIMNE Ift ATTIC STORAGE rails floor Z j rail-stairs skylight 2•.g• \ /' open space 56"plywood vndeFlaymQnt`w c5ryxl /�// to below 6"head roan height line ior 3/4"fin wood floor __.. /f-- :.:...... .9'-8" C NIC remove 1 -1 walls 10 2$-15 10-20-15 1 SECTION AT NEW ROOM / > - w 10-14-15 Ge 10-7-15 f3.5 ATTIC STORAGE a 10-1-15 o 12 / roof slope f D V ,-, 12 A-3.0 - ° E W n o _ u U J e. do, ? V N d � < Z o 6 U ALTERNATE#2 PRICE ALTERNATE#3 PRICE F -- -_ -_, new sliding windows storm windows for double glazing < o a SCREEN PORCH /t = E E MASTER r1(JjZrlp� �_ Z M E BED ROOM 1 0 � � relocate exg door to window header ' —� W (ll � > .,den exQ wdw -- - U •V W �nevv fiberglass i, ^,6x48 Jacuzzi 36x72' W N U hower _ �! °C d cabinet "i < 1 8'-2"x 12'-4" MS BATH 2 +4'-4°x8'-g° exg - newctosbipassdrs new' new BED RM 2 cabinet CL CL exg new shelf shelf&cab nen cab shelf new shelf OFFICE NURSURY SCHEME wash BATH 1 LAUNDRY newbifold D Z renovated ROOM dry =- - - - - cntr& W Q. k shower tut cab �GU 30X60 f - : CL CL W 10"radius Z 0 corner q � O O U- �l�i : _ CL ,�, ;; � tin r,� ( it Z_ Z �U l�P�►ue�(�% -, - - �► ,� N HALL BED RM 4 GUEST -2a- 15 1011BED RM 3 - 44- 1 -215 UP 1 10 -1.0 A- zrr - City of NorthamptcQ B Z4 zo/ uilding Department IV PI - — - - ° E w o E 212 tWin Street exg "' m �oi� �,door Northa tors. r ALTERNATE ri1 PRICE f ° new sliding windows and new door__ 5 (�,W z ^ v \ (exg ne 36"insulated o g dr e a u SCREEN PORCH hal glass door m F exg vx f o F DINE RM Xel Z > exg dr exgtdr C) .O V new U U 2"x24' _______ Of �}r. Closet ^` O = 4exg exg dr new 4'radlus KITCHEN exg dr I island 34x72 sk new rlf bath 4 di SCHEME who exg I ' new cabinets ( r/t 2.1 hatch cover � ,paint V new stairs Z ll restored 4(�� remove dr _ pN � �°�, � g - - newjolst doubted at star opening corner=2 9"LVLs sk W d i i i i i z0 RM LIVING \ z 0 1 1 0 0 removj I I I I I remove kitchen and interior walls ---' 11;_co—un- ter seat ing ting recss -- LL stairs t i Q install new window ~(n 'J Z f ' using exg header new I) 2x8 header i I I I � at exg door clos i ? r i 1 to be removed aT;gn slfto window exg BREAKFAST RM 10 -28- 15 10-20-15 w 10-14-15 2-2x8s heF STUDY DEN °C 10-7-15 W opening( exg exgdr � 10-1-15 136" I new - I °r steam To ri radiator exg cabinets exg dr _ A-1 .0 remove exg header —' NOT IN40NTRACT— removeezgheader w o enings with headers new pOft see A-1.1 new window openings with headers City of Northampton 212 Main Street, Northampton, Na 07060 Solid Waste Disposal AE-davit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111, S 150A. Address of the work: �� -,/` �« ; 12S The debris will be transported by: di. fete The debris will be received by: G� Building permit number: Name of Permit Applicant .✓re.cx 1 Date Sign-ature of Permit Applicant City of Northampton Massachusetts ;uu rT DEPARTMENT OF BUILDING INSPECTIONS 212 Main Street • Municipal Building Northampton, MA 01060 ss� •:7i INSPECTOR Louis Hasbrouck Chuck Miller Building Commissioner Assistant Commissioner HOME OWNER EXEMPTION ACKNOWLEDGEMENT The State of Massachusetts allows the homeowner the right under 780CMR 108.3.4 to act as his/her construction supervisor. The state defines "Homeowner"as, " Person(s) who owns a parcel on which he/she resides or intends to be, a one or two family dwelling, attached or detached structures accessory to such use and/or farm structures. A person who constructs more than one home in a two- year period shall not be considered a home owner." The building department for the City of Northampton wants any person(s) who seek to use the home owner exemption, to act as their own construction supervisor, to be aware that by doing so you become responsible for compliance with state building codes and regulations. The inspection process requires that the building department be called to inspect work at various stages, which include foundation/footings (before backfill), sonotube holes (before pour), a rough building inspection (before work is concealed), insulation inspection (if required) and a final building inspection. The building department requires these inspections before the work is concealed, failure to secure these inspections can result in failure to obtain a certificate of occupancy until the work can be inspected. If the homeowner hires other trades to perform work (electrical, plumbing & gas) the homeowner will be responsible to make sure that the trades hired secure their proper permits in conjunction to the building permit issued, and that they get their required inspections. Failure of the individual trades to secure the permits and inspections as required can DELAY the project until such time as the proper permits and inspections are made I, understand the above. (Home owner/resident's signature requesting exemption) I will call to schedule all required building inspections necessary for the building permit issued to me. Date Address of work location i The Commonwealth ofMlassachusetts Department of Industrial Accidents - - Office of Investigations 600 Washington Street r Boston, MA 02111 www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractor.s/Llectrncians/Plumbers Applicant Information Please Print Lezibly Name (Business/Organization/Individual): Address: City/State/Zip: Phone #: Are you an employer? Check the appropriate box: Type of project(required): ❑ I am a employer with 4. ❑ I am a general contractor and I 1. * have hired the sub-contractors 6. ❑New construction employees (full and/or part-time). 2.[� I am a sole proprietor or partner- listed on the attached sheet. 7. �Remodeling ship and have no employees These sub-contractors have g, ❑Demolition working forme in any capacity. employees and have workers' 9. ❑Building addition [No workers' comp. insurance comp. insurance.$ required.] 5. ❑ We are:a corporation and its 10.0 Electrical repairs or additions re 3.El I qu a homeowner doing all work officers have exercised their 11.X Plumbing repairs or additions per MGL myself. [No workers' comp. right of 1(4),exemption d we have 12.7 Roof repairs insurance required.] t c. 152, §1(4), and we have no employees. [No workers' 13.❑ Other comp. insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. tHo meowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. $Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Policy#or Self-ins.Lic. #: Expiration Date: Job Site Address: City/State/Zip: Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one-year imprisonment, as well as-civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties ofpe ury that the information provided hove true and correct. Si afore: Date: Phone#: Of use only. Do not write in this area, to be completed by city or town official City or Town: Permit/License Issuing Authority(circle one): 1. Board of Health 2.Building Department 3. City/Town Clerk 4.Electrical Inspector 5. Plumbing Inspector 6. Other Contact Person: Phone#: SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable E Name of License Holder: I'V, 0 11 �'2�'2- Lice m er 71� ow tdj&Er-16�U)j�IA 7-,Nu 1/ � Address r Exp4ation Date cl' rU Signature V lephone 9.Registered'Home em r: Not Applicable E rrT I ffig Company Name Registrati"o Numb Q Ll> —t11 'CU J. t-?-DI LJ 14 JIF,I Address Expiration'Date Telephone SECTION 10-WORKERS!COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c..1 52,§.26C(S)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... E No...... 7 7 The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is, or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned-"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature, SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition F7 Replacement Windows Alteration(s) ©- Roofing ❑ Or Doors 1;2 Accessory Bldg. ❑ Demolition ❑ New Signs r] Decks [M Siding [17] Other[❑] Brief Description of Proposed i FIt'17F 1. j (✓' �-(' C����t�'� jt��' L = -r�1�U Work: �Z/J�JL/�f°�% (r�: ISDC Alteration of existing bedroom V Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes ,, o Plans Attached Roll -Sheet sa If`New house'a`nd oraddtt%i°ort to existing housrng, corn�fefe fhe following a. Use of building :One Family `r Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating?. �f-t W Ere places or Woodstoves Number of each g. Energy Conservation Compliance.��- Masscheck Energy Compliance form attached? h. Type of construction waa;2y G�`cwiE, i. Is construction within 100 ft. of wetlands? Yes '� No. Is construction within 100 yr. floodplain Yes V No j. Depth of basement or cellar floor below finished grade Ig e k. Will building conform to the Building and Zoning regulations? V Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED .WHEN OWNERS AGENT OR CONTRACTOR APPLIES-FOR BUILDING PERMIT 1, AC� as Owner of the subject property hereby authori +1 A r�.t S - W4 rJ r. to act on my b half,in a matters rel i to ork utho ize by this building permit applicati n. j A 3 -2 G.) 5 Signature of OwrKr Date L7e 5erebrreclare as Owner/Authorized that the statements and i1hformation on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Print Name Signature of Ow Agent Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning /� This cols to be filled in by Building Department Lot Size Frontage I f I Setbacks Front F i. Side L: i R:= L:i= R:1 I Rear —Z}1 Building Height 3 �j Bldg. Square Footage % Open Space Footage (Lot area minus bldg&paved parking) #of Parking Spaces 1--�-- Fill: + (volume&Location) I A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO O DONT KNOW Q( YES 0 IF YES, date issued:, i . c IF YES: Was the permit recorded at the Registry of Deeds? NO Q DONT KNOW Q YES Q IF YES: enter Book j Pagel and/or Document# B. Does the site contain a brook, body of water or wetlands? NO 0 DONT KNOW Q YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Q Obtained Q , Date Issued: f C. Do any signs exist on the property? YES 0 NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES Q NO IF YES, describe size, type and location: j E. Will the construction activity disturb(clearing, grading, excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES O NO IF YES,then a Northampton Storm Water Management Permit from the DPW is required. t ;I f pe�artment use only City of Northampton Status ofPerm,t �' t ''r` ~x r - Building Department 'car,CurEDri�etivay Fermi#' Y �' 2 Main Street Sewer/SepicRuaifabllrty � i NOV 2 v 3 � Room 100 UVaterlMFel!Availability gg1 4 Co v,J o ampton, MA 01060 Twa Sei at5trctural Ptarts F `� � hone 13 87-1240 Fax 413-587-1272 :Plof%ISite Plans a G t °"'Mq oFC'oro Other 5pec�fy �. APPLICATION TO—CSUOTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE.INFORMATION This section fo be completed by office _= r Z. e Address: --=r 1.1 Property A Unit:—r='-=:: :'_.:��-- 1z H St.District �CB;.Distnct = !..i r SECTION 2.-PROPERTY OWN ER.SHIP/AUTHORIZED.AGENT: 2.1 Owner of Record: a n Name(Print) Current Mailing Address: ✓/ Telephone C, � + 11— Signature ELI 2.2 Authorize nt: e:1 f'i� Name(Print) ° Current Mailing Address: D_L/ 7 .3 Signature Telephone SECTION 3-*ESTIMATED CONSTRUCTION COSTS. . Item Estimated Cost(Dollars)to be Official Use Only completed by ermit applicant 1. Building (a)Building Permit Fee 2. Electrical (b)Estimated Tot@,I Cost of onstruction from 6 3. Plumbing Building Permit Fee 2 4. Mechanical(HVAC) j , 0 tom: . 5. Fire Protection 6. Total=(1 +2+3+4+5) Check Number t� This Section For 0fficial'Use Onl Date Building Permit Number: Issued: Signature: Building Commissioner/Inspector of Buildings: Date File#BP-2016-0715 APPLICANT/CONTACT PERSON JAMES PHANEUF ADDRESS/PHONE 74 Old Stage Rd W HATFIELD01088(413)247-9993 PROPERTY LOCATION 234 CRESCENT ST MAP 31A PARCEL 053 001 ZONE URB(100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Buildiny,Permit Filled out Fee Paid Tvpeof Construction:_REMODEL KITCHEN,BATHROOMS,REMOVE SERVICE STAIRWAY,ADD 1/2 BATH,INSTALL REPLACEMENT WINDOWS, INSULATION&REMOVE SIDE ENTRY New Construction Non Structural interior renovations Addition to Existing- Accessory Structure Building Plans Included: Owner/Statement or License 011632 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management e i ' De y Signature of Buil mg Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. 234 CRESCENT ST BP-2016-0715 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 31A-053 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: renovation BUILDING PERMIT Permit# BP-2016-0715 Project# JS-2016-001198 Est. Cost: $220000.00 Fee: $1430.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: JAMES PHANEUF 011632 Lot Size(sq. ft.): 6969.60 Owner: WINSTON JAMES Zoning: URB(100)/ Applicant: JAMES PHANEUF AT. 234 CRESCENT ST Applicant Address: Phone: Insurance: 74 Old Stage Rd (413)247-9993 W HATFIELDMA01088 ISSUED ON.1112412015 0:00:00 TO PERFORM THE FOLLOWING WORK.REMODEL KITCHEN,BATHROOMS, REMOVE SERVICE STAIRWAY, ADD 1/2 BATH, INSTALL REPLACEMENT WINDOWS, INSULATION & REMOVE SIDE ENTRY POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 11/24/2015 0:00:00 $1430.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner