Loading...
29-394 (2) i II solar=@@ Single Phase Inverters for North America S o I a r r SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ SE760OA-US/SE1000OA-LJS/SE1140OA-US SE3000A US -SE380OA US: SESOOOA US SE6000A USi SE76o0A US. SE10000A-US SE1140OA US ............._.. ...... . ......... - ..__. - _.. . _t _._ _ .. -. _ _... €........ _-.-._. OUTPUT 9980 @ 208V SolarEdge► ingle Phase Inverters • Nominal AC Power Output 3000 3800 5000 6000 7600 10000 @240V 11400 VA For N O C l l 1 A 1 1 1 erica Max.AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V- 12000 VA . 5450 @240V _ 10950 @240V AC Output Voltage Min.-Nom.-Maxl'i ✓ _ 183-208-229 Vac SE300OA-US/SE380OA-US/SE5000A-US/SE6000A-US/ AC Output Voltage Min-Nom.-MaxJti 211-240-264 Vac ✓ ✓ ✓ - SE7600A-US/SE10000A-US/SE11400A-U$ AC Frequency Min.-Nom.-Max."' 59.3-60-60.5(with Hl country setting 57-60-60.5) Hz € € k, {= 24 @ 7.O8V 48 @ 208V Max.Continuous Output Current 12.5 16 25 32 47.5 A fi r s 21 @ 240V 42 @ 240V GFDI Threshold I 1 A f ' _ f^.� ;� s r'" Utility Monitoring Islanding Protection Country Configurable Thresholds _ Yes _ „„ -Yes _ _INPUT --- -- - - -- -- ;� _ .. ...._......_. 4050 ... -. 5100 6750 .... .. 10250 .- 13500 15350 - W ...... Maximum DC Power(STC) 8100 t+ Transformer less,Ungrounded Yes - T Max.Input Volta ge 500 Vdc Nom.DC Input Voltage 325 @ 208V/350 @ 240V - Vdc % � 1 ►� t s 3 Max.Input Current"' 9.5 13 16.5 @ 208V 1$ 23 33 @ 208V _ 34.5 - Adc q ! 15.5 @ 240V _ 30.5 @ 240V Max.Input Short Circuit Current - 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600kn Sensitivity Maximum Inverter Efficiency 97.7 98.2 98.3 98.3 98 98 98 % ' .. CEC Weighted Efficiency 97.5 98 97.5 @ 208V 97.5 97.5 97 @ 208V 97.5 % < 98 @ 240V _ 97.5 @ 240V - Nighttime Power C_onsu_mption <2.5 <4 _ W k ADDITIONAL FEATURES „ E MR 5, Supported Communication Interfaces RS485,RS232,Ethernet,ZigBee(optional) r �,,., Revenue Grade Data,ANSI C12.1 OptionaP''. t r .- `'- 'V €€€ _Rapid Shutdown NEC 2014 690.12 __Functionality enabled when SolarEdge rapid shutdown kit is mstalledl01 STANDARD COMPLIANCE... ._ ._._... - ._ _._._. .__... ._._ -.... .. .._._ .. ..._._ _ ..__..... , [ �_ ,. �� ` ....Safety _._._.. _ .._._.._._ UL1741,UL1699B,UL1998,CSA 22.2 x A # sou Grid Connection Standards IEEE1547 - - i Emissions FCC partly class B 1 INSTALLATION SPECIFICATIONS... �,`� T J c size/AWG range 3/4'minimum/16 6 AWG 3/4 minimum/8-3 AWG AC output conduit si G A ' € q' DC input conduit size/H of strings/ 3/4"minimum/1-2 strings/ s AWG range 3/4"minimum/1-2 strings/16-6 AWG 14-6 AWG " - Dimensions with Safety Switch 30.5 x 12.5 x 10.5/ in/30.5 x 12.5 x 7.2/775 x 315 x 184 (HxWXD) _ < 775 x 315 x 260 mm Weight with Safety Switch S1.2/23.2 _ 54.7/24.7 88.4/40.1 lb/kg Natural , L convection ``.� p _ psi _ Cooling Natural Convection and internal Fans(user replaceable) �J fan(user ' - replaceable) JOrEd 6 bled systems Noise l <25 <50 ! dBA -.fnte�rat d rric fau, pKG#�EG'�{pTt(Type��for NEC�{���.�t'�1�:�.�.ICLf111p{�f1C£ Min.-Max.Operating Temperature -13 to+140/-25 to+60(-40 to+60 version availableis)) 'F/'C Range , Su perior efficlency(98%) Protection Rating NEMA 313 Small,lightweight and easy to install on provided bracket:- €.i For other regional settings please contact SolarEdge suppon. i1 A h gher current source may be used,the inverter-11 limit its imput current to the values stated. - Suitt-in Module-level monitoring I3I Revenue grade inverter P/N:SExxx US"NNR2 Ifor 760OW mwrtersE7600AUS002NNR2) °i Rapid shutdown kit P/N:SE1000-RSU-St. Internet connection through Ethernet'..orWireless isi40wrionP/N:SE- -US000NNU4(for 7600W invert,,:SE7600A-US002NNU4). Outdoor and indoor installation Fixed voltage inverter,DC/AC conversion only Pre-assembled Safety Switch for faster installation Optional-revenue grade data,ANSI C12.1 sijftszc RoHS USA G RIMANY ;TAL ff„,;CE JAPAN CHINA AUSTRALIA THE NETHU.LANDS SRAEI. VVLRiw.solaredge.us THE Trionamoue t MODULE TSM-PDO5.18 Mono Multi Solutions ......................... ......................- DIMENSIONS Of PV MODULE ELECTRICAL DATA VSTC unit:mm Peak Power Watts-P.-(Wp) 250 255 260 265 941 I Power Output Tolerance-P..rX) 0-+3 JUN-N �o Maximum Power Voltage-V-(V) 30.3 30.5 30.6 30.8 THE Trinal I I U U I I t 0 Maximum Power Cwtent-l-,(A) 8,27 8.37 8,50 8.61 Open Circuit Voltage-Voc(V) 38.0 38.1 38.2 38.3 ­F Short Circuit Current­lsc(A) 8.79 8188 9.00 91.10 Module Efficiency rlm(%) 15.3 15.6 15.9 16-2 STC:Irradiance 1000 W/m,`,Cell Temperature 25°C,Air Mass AMI.5 according to EN 60904-3. MODULE Typical efficiency reduction of 4,5%at 200 W/m'according to EN 60904-1. ELECTRICAL DATA:36 NOCT Maximum Power-P.-(Wp) 186 190 193 197 60 CELL Maximum Power Voltage-V­(V) 28.0 283 2813 28.4 MULTICRYSTALLINE DUL Maximum Power Current IMP=(A) 6.65 6.74 6.84 6,93 MOE PD05.18 Open Circuit Voltage(V)-Voc(VI 35.2 35.3 35,4 35.5 WITH TRINAMOUNT FRAME Short Circuit Current(A)-I.(A) 7.10 7.17 7.27 7.35 NOCT Irradiance at 800 W/m'.Ambient Temperature 20°C,Wind Speed I ml,. 812 250- -26_5WWW BackView 180 MECHAWCAL DATA POWER OUTPUT RANGE Solar cells Multicrystalline 156-156 mm(6 inches) Fast and simple to install through drop in mounting solution OQ, Celt orientation 60 cells(6 x 101 Module dimensions 1650 x 992 x 40 Trim(64.95 x 39.05 x 1.57 inches) Weight 19,6 kg(43.12 lbs) OA/0- Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass MAXIMUM EFFICIENCY Backsheet White ��' Good aesthetics for residential applications F me Block Anodized Aluminium Alloy J-Box IP 65 or IP 67 rated Cables Photovoltaic Technology cable 4.0 mm-(0.006 inches'), 0-w+ 0' 1200 mm(47.2 inches) POSITIVE POWER TOLERANCE L-V CURVES OF PV MODULE[260W) Connector H4Amphenol Fire Type UL 1703 Type 2 for Solar City Highly reliable due to stringent quality control aw '10 i­no_;�e�-s+s r r 1 7. As a a II cj o b a I rr-,I r u I'D c I-j f e- g,,)_--� Cey,,,cj er 1'4 r re e e, TEMPERAT RE RATINGS MAXIMUM RATINGS of generctir n pl­,oto Ita., Lill U 4m Operational Temperature -40­851C L,,01�ulcts,o-ei bel-ave close X1 Nominal Operating Cell 441C(t21C) 4NWTK-,-_7, Temperature(NOCT) cooperat.oin wilh our Maximum System 1000V DC(IECI ........... ................. ............ I A SC:Tticaltosuccesln, Vvl�rh.o'-Ol ....................... .......... Temperature Coefficient of P-x -0.41%/*C Voltage 1000V DC(UL) n!P Temperature Coefficient of Voc -0.32%/"C Max Series Fuse Rating 15A sence ctrot Lid ti- jlob-_-,,,Ttina is able to povide excep t.f-mal set vice ow to ecich c_,StoFre­­!r­i eod�rno,x,et Certified to withstand challenging environmental o to Zii 3D 4D w Temperature Coefficient of Isc 0,057f IC c,i r.d s i,o p I e rn e n Ii Out conditions rel:ob5e oroicticls W­ e'_XXXI)� cf TF'nc os a ss'rong,.borkable WARRANTY -�,c ioad tncwfner. We alre cornrnitjr­_� r 10 year Product Workmanship Warranty to bufld.ng�'rrotegic,riti.i-io"y CERTIFICATION beneficid 25 year Linear Power Warranty colk-ilocrolion w'.qi insta;,erl-.devNoPEi,S (Please refer to product warranty for detailsl < or d o1he!oc,inerscis It os oackbone o,our shated si_,ccess in anvIng Sfrna­Ertefgy Togefhoi. CIO LINEAR PERFORMANCE WARRANTY PACKAGING CONFIGURATION 10 Year Product Warranty-25 Year Linear Power Warranty Modules per box:26 pieces z Trino Solar Limited M; 7 a ii 01c",.C c I- 4il00% Modules per 40'contomer:728 pieces value l___ o 90% Pr Ina S Icli s line,, o 6 rant, CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. 0 2015 Trina Solar Limited.All rights reserved.Specifications included in this datasheet are subject to �41 g,oMPAT Trin-asolar 0,80% Trin-asolar change without notice. Sinart Energy Togeune, ;.nor'Er',er;gy Tno-her Years 5 1� IS 20 25 THE r% mount MODULE TSM-PD05.18 Mono Multi Solutions DIMENSIONS OF PV MODULE Umf:mM Peak Power Watts-P.-(Wip) 245 250 255 260 941 Power Output Toleronce-P­(%) 0­3 1-TION Maximum Power Voltage-V-(V) 29.9 30.3 30.5 30.6 Maximum Power Cvrrent-l.p°(A) 8.20 8.27 8.37 8.50 T'HE TIF,ME 9 1 i a o u n t U; Open Circuit Voltage-Voc(V) 37.8 38.0 38.1 38.2 core -Isc JAI 8M Short Circuit Current 8.75 8,79 9.00 Z Module Efficiency rlm 15.0 15.3 15.6 153 If I U ITC:1-di-c.1000 W/rd',Cell Temperature 25°C.Air Mass AMI.5 according to EN 60904-1 Typical efficiency reduction of 4.5%at 200 W/W according to EN 60904-1. O ELECTRICAL DATA,t NO OT Maximum Power-PIAX(Wp) 182 186 190 193 6 0 0.11 LI L Maximum Power V01tage-V-(V) 27.6 28.0 28.1 28.3 MULTICRYSTA ELINE MODULE smaaanouRUna cafe Maximum Power Current-1-(A) 6.59 6.65 6.74 6.84 WITH TRINAMOUNT FRAME A -A� Open Circuit Voltage(V)-Voc(V) 36.1 35,2 35.3 35.4 Short Circuit Current(A)-1.(A) 7.07 7.10 717 7.27 AE i NOCT:Irradiance at 800 W/d-i Ambient Temperature 20°C,Wind Speed 1 m/s. PD05.18 81 180 2 45 M 2%6 0 W Back View POWER OUTPUT RANGE MEC14ANICAL DATA Solar cells Multicrysialline 156 x 156 mm(6 inches) Fast and simple to install through drop in mounting solution 1 Cell orientation 60 cells(6-10) Module dimensions 1650 x 992 x 40 mm(64,95 x 39.05 x 1.57 inches) Weight 21.3 kg{470 lbs) YO ------ MAXIMUM EFFICIENCY Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass A-A White Backsheet Good aesthetics for residential applications Frame Black Anodized Aluminium Alloy with Trinamount Groove i-V CURVES OF PV MODULE i 1-Box IP 65 or IP 67 rated 0^s+3%0 ................... ........... ..................-............................ ......................... Cables Photovoltaic Technology cable 4.0 mm'(0.006 incheS2), POWER OUTPUT GUARANTEE 1200 mm(47.2 inches) Fire Rating Type 2 800W/m2 .� Highly reliable due to stringent quality control 7 6.-[ C?V� _,u fests WV, 1C,I 4.m1 400Wr2 --- EA PAT NGS A,a global manuf�OrturCr .�e'es ng g, es�-,;efl bey��nd cerliricai i-*_.i,rrc, t ;,e.!-',e, D, T_.A.P� MAXIMUM RATINGS of nex�Cenerotion pho-rovcMail- 3 foroducts,we i close 2.�L_200W/ml Nominal Operating Cell 44-C(_2°C) Operational Temperature -40-+85oC Temperature INOCT) _1 Maximum System 1000V DCJIEQ ............. .............. i 5A_ - Temperature Coefficient of P- 0AI%/'C Voltage )000VDC(UQ S lical t-success. W;ih _-Cal to.- 30.- 40.- ores epce around the olobe, L;na iE Temperature Coefficient of Voc 0.32%/'C Max Series Fuse Rating 15A Voi cible to orovide exceptiorial e'vice Temperature Coefficient of Isc 0.05%/'C c,each cuslome,In each t-iarKe- Certified to withstand challenging environmental d s uo P l e I-.e r I o-,r I n n ovc"ve. conditions reIiabje Proaucis with e bcil-"'^g U of Trir,o WARRANT' as 0 stfong,barkab Liu::"i We are"'orlify0ted 10 year Product Workmanship Warranty 25 year Linear Power Warranty oerieficial col.aborcitior-:with msmlle!>,develooers,6sinbuteci-s (Please refer to product warranty for details) and olne,pamiers as the �ac,icborna ,,f Our In CERTIFICATION driv r"g snnc, elgy orj LINEAR PERFORMANCE WARRANTY PACKAGING CONFIGURATION --"- - 10 Year Product Warranty 25 Year Linear Power Warranty Modules per box:26 pieces 61 'Grins Solar Limited Modules per 40*container!728 pieces 21 Z2 ............------- nos C-PLIANT 90' for line 's o at Warr CAUTION READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT.•Dina C 2014 Trina Solar Limited,All rights reserved,Specifications included in this clatasheet are subject to 0 80% change without porce. Innasolar Trinasolar RE t neray Toget'ner Year, 5 10 t5 20 25 v ' I r I I I i • I solar=ee solar " i • C SolarEdge Power Optimizer Module Add-On for North America P300 / P350 / P400 SolarEdge Power Optimizer P300 P350 P400 Module Add-On For North America (for 60-cell PV (for 72-cell PV (foe 96 cell PV modules) modules) modules) • INPUT ..,._ _ P300 / P350 / P400 uT o t Voltage( c at lowest temperature) Rated Inp t DC P werui 300 350 400 W Absolute Maximum input Ira a Vo 48 60 80 Vdc MPPT Operating Range 8 48 8-60 8-80 Vdc T,F .t r 7 ,� • : Maximum Short Circuit Current(Isc) 10 Adc Maximum DC Input Current 12.5 Adc Maximum Efficiency 995 % Weighted Efficiency 98.8 % Ov_ervo tage Category II OUTPUT DURING OPERATI ON(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Maximum Output Current 15 Adc '`, "� ¢t • Maximum Output Voltage 60 Vdc ' ,E w Ir ;�°' OUTPUT DURING STANDBY)POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer_ 1 Vdc x STANDARD COMPLIANCE _ - } ICI EMC FCC Part15 Class 3,IEC61000 6 2,IEC61000-6-3 Safety IEC62109-1(class II safety),UL1741 n RoHS Yes ......... INSTALLATION SPECIFICATIONS _ Maximum Allowed System Voltage 1000 Vdc Y g t( , I^ '`',u�) Dimensions(W x L x H) 141 x 212 x 40.5/5.55 x 8.34 x 1.59 mm/in_ Weight(including cables) 950/2.1 gr/lb Input Connector _MC4/Amphenol/Tyco Output Wire Type/Connector Double Insulated;Amphenol 51 ` E... Output Wire Length 0.95/30 1.2/3.9 ./ft Operating Temperature Range -40-+86/-40-+185 'C/'F [ Protection Rating IP65/NEMA4 ,t;, Relative Humidity 0-100 % es cn .,rmr mae.MOaeo wa sx vo.e.o e,aaa mwm. Al Y' THREE AS E THREE PHASE SYSTEM DESIGN USING SINGLE PHASE INVERTER 208V 480V !, ............ Minimum String Length(Power Optimizers) 8 _. 10. 18 ++'UficR55a mcreenef Maximum String Length(Power Optimizers) 25 25 50 Superior ! Maximum Power per String 5250 6000 12'750 W r eff cj 99.59b Mt te5 all t g $ ,Parallel Strings of Different Lengths or Orientations Yes rigs ypeisofmodulemismatchl osses,frommanufaeturin tolerance to partialshadin = Flexible fy9tem deslgo for maximum space utilization Fast installation with a single.bolt i — Next generation maintenance with module-level monitoring Module-level voltage shutdown for installer and firefighter safety J`;A GFRMA.Ne - ITALY - IRANCL - i7.FAN - CH:PiA SizA, XiSTR.ALIA WWW.:Olar0(jge.u.S I I I I I �I I 'it^SolarCity ®pSolar Next-Level PV Mounting Technology '1,SoiarCity ®pSolar Next-Level PV Mounting Technology Zep System Components for composition shingle roofs i I� tJp—rx!� i ��Z.� LN•rtxk �, ��. i xpCwnpaUhlePV e r N t iy �I t f � M#Attxlxnrrrt i „' Arraq QGeMPA>/ Description h v PV mounting solution for composition shingle roofs FACeMPp'00 • Works with all Zep Compatible Modules • Auto bonding UL-listed hardware creates structual and electrical bond Apo • Zep System has a UL 1703 Class"A"Fire Rating when installed using V� LISTED modules from any manufacturer certified as"Type 1"or"Type 2" Comp Mount Interlock Leveling Foot Part No.850-1382 Part No.850-1388 Part No.850-1397 Listed to UL 2582& Listed to UL 2703 Listed to UL 2703 Specifications Mounting Block to UL 2703 Designed for pitched roofs Installs in portrait and landscape orientations ^ Aln • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices Ground Zep Array Skirt,Grip,End Caps DC Wire Clip • Attachment method UL listed to UL 2582 for Wind Driven Rain Part No.850-1172 Part Nos.500-0113, Part No.850-1448 Listed to UL 2703 and 850-1421,850-1460, Listed UL 1565 ETL listed to UL 467 850-1467 zepsolar.com zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zap Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zap Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. 02 27 15 ZS for Comp Shingle Cutsheet Rev 04.pdf Page: 1 of 2 02 27 15 ZS for Comp Shingle Cutsheet Rev 04.pdf Page: 2 of 2 WARNING:PHOTOVOLTAIC POWER SOURCE Label Location: "• • •n: Label Location: -- Code: 'WARNING -- .�-WARNING D ..- NEC ELECTRIC SHOCK HAZARD ELECTRIC SHOCK HAZARD 690.31.G.3 DO NOT TOUCH TERMINALS ••/ THE DC CONDUCTORS OF THIS 690.35(F) •- • • TERMINALS ON BOTH LINE AND PHOTOVOLTAIC SYSTEM ARE • BE• PHOTOVOLTAIC DC LOAD SIDES MAY BE'ENERGIZED UNGROUNDED AND DISCONNECT Code: IN THE OPEN POSITION MAY BE ENERGIZED UNGROUNDED • NEC .•1 Label Location: Label • • (POI MAXIMUM POWER- INTERCONNECTION Code: POINT CURRENT WARNING: ELECTRIC SHOCK MAXIMUM POWER-- Code: HAZARD. DO NOT TOUCH • 1 690.54 POINT VOLTAGE(Vmp) V NEC 690.53 TERMINALS.TERMINALS ON MAXIMUM SYSTE(v1 BOTH THE LINE AND LOAD SIDE VOLTAGE(Voc)_v MAY BE ENERGIZED IN THE OPEN SHORT-CIRCUIT POSITION. FOR SERVICE CURRENT{Isc)_q DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE MAXIMUM AC A OPERATING CURRENT MAXIMUM AC Label Location: OPERATING VOLTAGE V WARNING ' P er ..- ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED 690.5(C) NORMALLY GROUNDED Label L• • CONDUCTORS MAY BE CAUTION UNGROUNDED AND ENERGIZED (POI) DUAL POWER SOURCE Per Code: SECOND SOURCE IS 690.64.13.4 PHOTOVOLTAIC SYSTEM Label • • WARNING ELECTRICAL SHOCK HAZARD Code: Label • • DO NOT TOUCH TERMINALS NEC 690.17(4) CAUTION ')(PO TERMINALS ON BOTH LINE ANO Per Code: LOAD SIDES MAY BE ENERGIZED PHOTOVOLTAIC SYSTEM IN THE OPEN POSITION CIRCUIT IS BACKFED NEC 690.64.B.4 DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT Label • • Per WARNING ..- INVERTER OUTPUT Label Location: CONNECTION 690.64.B.7 PHOTOVOLTAIC AC •I) sconnect DISCONNECT Per ••- THISODEVCERRENT Condui NEC •.1 :. Panel(D): Distribution(DC): DC Disconnect Interior . • Label Location: (INV): Inverter With Integrated DC Disconnect MAXIMUM AC A (POI) OPERATING CURRENT •"• Center Code:Per MAXIMUM AC V NEC 690.54 OPERATING VOLTAGE -• Point of • • 3055 Clearview Way San Mateo,CA 94402 MIA"411151,4109 1011111114111i[a a i . a • jai • • • I . . � •r � a � a •r r� � � CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 99 Brookwood Dr UTILITY SERVICE AC DISCONNECT INVERTER AND DC DISCONNECT r-------------------- ------� SOLAR PHOTOVOLTAIC ARRAYS) L--------------------------J PHOMVOLTAIC BACK—FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V IB-0101421-00 CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J B-0101421 00 PREMSE 0111110t DESCIVION: DLL : ��► CONTAINED SHALL NOT BE USED FOR THE SCHUBACH, CYNTHIA SCHUBACH RESIDENCE Garren Lewis `�O'ar�'�" BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING S`rsTEM: A•4 r, re NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 99 BROOKWOOD DR 4.16 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: FLORANCE, MA 01062 THE SALE AND USE OF THE RESPECTIVE (16) TRINA SOLAR # TSM-260PDO5.18 24 SL Martin Drive,Building z Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV. DATE Marlborough,MA 01752 PERMISSION OF SOLARCITY INC. INVERTER: 4135864245 PV 7 s 22 2ot5 . (650)638-1026 F: (650)638-1029 SERTER: GE SE3800A—USOOOSNR2 SITE PLAN PLACARD / / ( )-sa-aTr(7s5-24s9) w...9alaratyaam GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number:MPU Inv 1: DC Ungrounded INV 1 -(1)SOLAREDGE SE5000A-US00OSNR2 LABEL: A -(19)TRINA SOLAR ## TSM-260PDO5.18 GEN #168572 RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:96 659 691 Inverter; 5 OW, 240V/208V, 97.5;/97%; w/United Disco and ZB,RGM,AFCI PV Module; 260W, 236.9W PTC, 40MM, Black Frame, H4, ZEP, 1000V ELEC 1136 MR Overhead Service Entrance INV 2 Voc: 38.2 Vpmax: 30.6 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER N 200A MAIN SERVICE PANEL N 20OA/2P MAIN CIRCUIT BREAKER (E) WIRING Inverter 1 CUTLER-HAMMER 20OA/2P Disconnect 2 SOLAREDGE SE5000A-USOOOSNR2 (E) LOADS A Lt zaav L2 30A/2P N 1 ---- GND --——————————————————————————————————— —EGG DG. DC, - - AA I GEC N DG LDC- MP1: 1x19 GND __ EGC——————————————————————————————————————— EG-—————————————--—— ♦J I , I N I c EGCIGEC I I I I GEC—r—♦ II TO 120/240V SINGLE PHASE I I I i UTILITY SERVICE I i I i I I I I I i I PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP Ol (2)Ground Rod; 5/8'x 8', Copper A (I)CUTLER—HAMMER /DG221URB /tr A:—(19)SOLAREDGE�300-2NA4AZS D� Disconnect; 30A, 24OVac, Non—Fusible,NEMA 3R A PowerBox ptimizer, 30DW, H4,DC to DC, ZEP —(1)CUTLER—�IAMMER I DG03ONB Ground eutrd Kit; 30A, General Duty(DG) (1)AWG#6, Solid Bare Copper j (1)Ground Rod; 5/8" x 8', Capper (N) ARRAY GROUND! P R EXCEPTION NO. 2, ADDITIONAL ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE �(1 AWG#10. THWN-2. Black _ * 500 V 1 O Isr (1)AWG 110, THWN-2, Red (2)AWG/10, PV Wire, 600V, Black Voc —500 VDC Isc =15 ADC LU=LL O (1)AWG,#6, Solid Bare Copper EGC Vmp =350 VDC Imp=13.93 ADC (1)AWG/10, THAN-2, White NEUTRAL Vmp =240 VAC Imp=21 AAC IT, (1)Conduit Kit;.3/4'.EMT. . .. . .. .... .. . . . . .. .. . . . . . . . . } . . . . . . .7.0)0!P/8,TFLWN-2,,Green . . EGC/GEC.-(1)Conduit,Kit;.3/4',EMT,. . . . I CONFIDENTIAL— THE INFORMATION HEREIN IDB NuMIR JB-0101421 00 PREMISE OWNER DESCRIPTION: DESIGN: CYNTHIA SCHUBACH RESIDENCE Garren Lewis Sod ��' CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTItG SYSIEM: r.r�= NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 99 BROOKWOOD DR 4.16 KW PV ARRAY ►�� Y PART TO OTHERS OUTSIDE THE RECIPIENT'S FLORANCE MA 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH r THE SALE AND USE OF THE RESPECTIVE (16) TRINA SOLAR # TSM-260PDO5.18 1 24 St.Martin Drive,Building z Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME-- SHEET: REV: DATE Marlborough,MA 01752 PERMISSION OF SOLARCITY INC. P� 4135864245 PV 6 9/22/2015 - (650)638-.1028 F. (650)638-1029 SOLAREDGE SE3800A—LIS000SNR2 THREE LINE DIAGRAM (888T)* -CITY(765-2489) www.sdarcitycom S1 5'-6" 01 5'-6" (E) LBW SIDE VIEW OF MP1 NTS OF MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES CKI LANDSCAPE 72" 24" STAGGERED 00 CIVIL co No.51873 PORTRAIT 4811 1711 @ ROOF AZI 164 PITCH 20 RAFTER 2x4 @ 24" OC STORIES: 1CNVA1 ARRAY AZI 164 PITCH 20 C.J. 2x4 @24" OC Comp Shingle STAMPED FOR STRUCTURAL ONLY PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) (2) URSEAL PILOT HOLE WITH ZEP COMP MOUNT C POLY ZEP FLASHING C (3) (3) INSERT FLASHING. (E) COMP. SHINGLE (4) PLACE MOUNT. (1) (E) ROOF DECKING (2) INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES WITH SEALING WASHER (6) INSTALL LEVELING FOOT WITH (2-1/2" EMBED, MIN) BOLT & WASHERS. (E) RAFTER STANDOFF SScale: 1 1/2" = 1' CONFlDENTIAL— THE INFORMATION HEREIN ,p8 NumBEk PREMISE OWNER. DESCRIPTION. DESIGN: CONTAWIED SHALL NOT E USED FOR THE JB-0101421 00 SCHUBACH, CYNTHIA SCHUBACH RESIDENCE Garren Lewis SolarCity.E�ENEFlT OF ANYONE EXCEPT SOLARgTY INC., MOUNTNG SYSTEM: AWJ4NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount T e C 99 BROOKWOOD DR 4.16 KW PV ARRAY �� PART TO OTHERS OUTSIDE THE RECIPIENTS p ORGANIZATION.EXCEPT IN CONNECTION WITH MODULES FLORANCE, MA 01062 THE SALE AND USE OF THE RESPECTIVE (16) TRINA SOLAR # TSM-260PD05.18 24 St.Martin Drive,Building z Unit 11 SOLARgTY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: Marlborough,MA 01752 PERMISSION OF SMENT. TY INC. ID�TM' T: (650)638-1026 R (650)638-1029 SOLAREDGE SE3800A—US000SNR2 4135864245 STRUCTURAL VIEWS PV 4 9/22/2015 (666)-SOL-CITY(765-2469) www.waarcitycom PITCH: 20 ARRAY PITCH:20 Digitally signed by Kyle Jackson MP1 AZIMUTH:164 ARRAY AZIMUTH: 164 Date:2015.09.23 09:52:20-06'00' MATERIAL:Comp Shingle STORY: 1 Story �N OF CKSON 0 CIVIL � No 51873 .o �t 'Tc At STAMPED & SIGNED FOR I STRUCTURAL ONLY LEGEND (E) UTILITY METER & WARNING LABEL -�� C4- INVERTER J 1 INVERTER W/ INTEGRATED DC DISCO p & WARNING LABELS \ ' DC LOA DC DISCONNECT & WARNING LABELS M © AC DISCONNECT & WARNING LABELS AC Q DC JUNCTION/COMBINER BOX & LABELS FEF(D� DISTRIBUTION PANEL & LABELS 9 e E) Lc LOAD CENTER & WARNING LABELS Inv O(E) DRIVEWAY DEDICATED PV SYSTEM METER Front Of House A C STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR — GATE/FENCE Q HEAT PRODUCING VENTS ARE RED Vq Brookwood D r INTERIOR EQUIPMENT IS DASHED L �J SITE PLAN N Scale: 1/8" = 1' W 01' 8' 16' E S CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-0101421 00 PREMISE 004M: DESCRIPTION: DESIGN: SCHUBACH, CYNTHIA SCHUBACH RESIDENCE Garren Lewis '\� �SolarCit CONTAINED SHALL NOT BE USED FOR THE �."Za BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: Rio NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp ount Type C 99 BROOKWOOD DR 4.16 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS P ORGANIZATION,EXCEPT IN CONNECTION WITH MODULES FLO R AN CE, MA 01062 THE SALE AND USE OF THE RESPECTIVE (16) TRINA SOLAR TSM-260PDO5.18 24 sc Martin ,Building z Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE Marlborough,MA 01752 PERMISSION OF SOLARCITY INC. INVERTER 4135864245 PV 3 9/22/2015 (Beej-SON-CITY(765-24F8.9) wma arcity.T SOLAREDGE SE3800A-USOOOSNR2 SITE PLAN I I II I I I II I I I I i I 109'-11" I 106 —4" I I I i II I I Ii 138,-4„ PROPERTY PLAN N Scale:1" = 20'-0' W—$�0 20' 40' f S CONFIDENTIAL A THE INFORMATION HEREIN [MODULES:BER PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE J B-0101421 00 SCHUBACH, CYNTHIA SCHUBACH RESIDENCE Garren Lewis hht'SolarCity.BENEFIT OF ANYONE EXCEPT SOLARCITY INC., G SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 99 BROOKWOOD DR 4.16 KW PV ARRAY '�r PART TO OTHERS OUTSIDE THE RECIPIENT'S FLORANCE MA 01062 ORGANIZATION, EXCEPT RI CONNECTION WITH ,THE SALE AND USE OF THE RESPECTTVE TRINA SOLAR # TSM-260PD05.18 24 St Math Drive,Building 2,unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN : PAGE NAME SHEET: REV: DATE: T: (850)M838-1028 F:A(617 638-1029 PERMISSION of soLARaTY INC. REDGE SE3800A—USOOOSNR2 4135864245 PROPERTY PLAN PV 2 9/22/2015 (888)—SCI-CITY(2ss-2489) w.eebratr.�«n ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID-INTERTIED VIA A AC ALTERNATING CURRENT UL-LISTED POWER-CONDITIONING INVERTER. vUe l�2G�YL/ ` -` <�-� BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. ///% CONC CONCRETE 3. A NATIONALLY-RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET-BACK A SIGN WILL BE PROVIDED WARNING OF THE City of Northampton GALV GALVANIZED HAZARDS PER ART. 690.17. Building Department GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE Plan Review GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY 212 Main Street HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. Northampton, MA 01060 1 CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL-LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 PROPERTY PLAN • PV3 SITE PLAN PV4 STRUCTURAL VIEWS PV5 UPLIFT LICENSE GENERAL NOTES PV6 THREE LINE CALCULATIONS RAM GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION Cutsheets Attached ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Northampton REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: National Grid USA (Massachusetts Electric) * * * * CONRDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J B-0101421 00 PREMISE ONHER: DESCRFnON. CONTAINED SHALL NOT E USED FOR THE SCHUBACH, CYNTHIA SCHUBACH RESIDENCE Gorren Lewis ��,,`�O'ar�'}" BENEFlT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �.,�a `r® NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 99 BROOKWOOD DR 4.16 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MDOULES FLORANCE MA 01062 ORGANIZATION,EXCEPT IN CONNECTION MATH 24 St.Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (16) TRINA SOLAR # TSM-260PDO5.18 APN: SOLARCITY EWIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REV DAIS T. (650)638-1028 MA(50) 636-1029 PERMISSION OF SOLARCITY INC. ISOLAREDGE # SE3800A-USOOOSNR2 4135864245 COVER SHEET PV 1 9/22/2015 1 (666)-SCI-CITY(765-2469) www.sdarcity.com City of Northampton Mail-Re: 99 Brookwood Dr SolarCity https://mail.google.com/mail/u/0/?ui=2&ik=39211afc3d&view=pt&q=... ate: O G� City Of Charles Miller<cmiller @northamptonma.gov> ,�� Xorttturreptort Re: 99 Brookwood Dr SolarCity 1 message Charles Miller <cmiller @northamptonma.gov> Fri, Oct 9, 2015 at 3:27 PM To: Louis Hasbrouck <Ihasbrouck @northamptonma.gov> Hi, I am reviewing the application provided and the value for the project appears low. Please provide cost backup for this project, material and installation invoices or estimates. Thanks, Chuck Miller On Fri, Oct 2, 2015 at 11:32 AM, Louis Hasbrouck<Ihasbrouck @northamptonma.gov> wrote: I put the plans in plans\99 Brookwood. Louis Hasbrouck Building Commissioner City of Northampton Town of Williamsburg (413) 587-1240 office (413) 587-1272 fax ------ Forwarded message ---------- From: Victoria Junck<vjunck @solarcity.com> Date: Thu, Oct 1, 2015 at 4:47 PM Subject: 99 Brookwood Dr SolarCity To: "Ihasbrouck @northamptonma.gov" <Ihasbrouck @northamptonma.gov> Applications going out in the mail tomorrow. Victoria Junck I Permit Coordinator I Springfield SolarCity M: 978-215-2367 C:413-454-9753 vjunck @solarcity.com I www.solarcity.com SolarCity. mu MA HIC-168572 1 MA-LIC 1136MR CT HIC-0632778( CT-0125305 E1 1 of 10/19/2015 9:47 AM CALCULATION OF DESIGN WIND LOADS- MP1 Mounting Plane Information Roofing Material Comp Roof PV System Type SolarCity SleekMountTM Spanning Vents No Standoff Attachment Hardware Comp Mount Type C Roof Slope 200 Rafter Spacing 24"O.C. Framing T Direction Y-Y Rafters Purlin Spacinq X-X Purlins Only NA Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only NA ,Standing Seam/Trap Spacing SM Seam Only NA Wind Desi n Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 90 mph Fig.6-1 Exposure Category C Section 6.5.6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height h 15 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 6-3 Topographic Factor Krt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh=0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 15.0 Psf Wind Pressure Fact. Pressure Coefficient U G -0.88 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down G W" 0.45 Fig.6-11B/C/D-14A/B Design Wind Pressure p p=qh(G ) Equation 6-22 Wind Pressure U -13.1 psf Wind Pressure Down 10.0 Psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacinq Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 20 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -223 Ibs Uplift Capacity of Standoff T-allow 500 Ibs Standoff Demand]Capacity I DCR 44.6% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever Portrait 17" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -247 Ibs Uplift Capacity of Standoff T-allow 500 Ibs Standoff Demand/Capacity DCR 1 49.4% Simpson Strong-Tie Truss: MPl Project Name: JB-0101421-00 Component SolutionSTM Date: 9/23/2015 11:38:51 AM Toss Page: 1 of 1 Version:5.18.50[Build 11] Span Pitch Qty OHL OHR CANT L CANT R PLYS Spacing WGT/PLY 22-M 5/12 1 1-2-0 1-2-0 0-0-0 0-0-0 1 24 in 72lbs 24-4-0 1-2-0 5-6-0 5-&0 5-6-0 5.6-0 1-2-0 F------� 56-0 11-� -----------+ 16-6-0—._____".._—_ 22-0-0---- 4x6- -3 12 12 -15 1x41 1x4/ 2 j 4 0 3x6 3x5- -9 U4 3x4- 0-0-0 0-0-0 7-6-10 6-10-13 7-6-10 7.6-10 145-6 22-0-0 -- Loading General CSI Summary Deflection L/ (loc) Allowed Load (ps0 Bldg Code: IBC 2012/ T'C: 0.41(2-3) Pert TL 0.17 in L/999 (56) L/180 ROOfBnowgPs): 28psf TPI 1-2007 BC: 0.58(1-1 Yea LI_ 0.04 in L/999 (56) L/240 TODL: 9(nd.) Rep Mbr Increase: Yes Web: 0.23(3-7) H..TL 0.05 in 5 BCLL: 0 D.O.L.: 125% Creep Factor,Ka=1.5 BCDL: 6 Plate OlFsets(3neX,Y,Ang): (1:3-14,2-3,0.) (2:0-0,3-13,44.)(3:0-0,3-13,0.) (4:0-0,3.13,44.)(5:3-14,2-30.) (6:0-0,3-8,0.) (7:0{1,348,0.) Reaction Summary 3T Type are Cut&. Brg Width Material Rqd Brg Width Max React Marc C—UpW1 Max MWFRS Uplift Max CA.0 UpU Max Oplitt Marc Honz I Pin(Wall) 1 3.5 in Steel 1.74 in 1,112 His - - - 0 lb, 5 H Roll(Warp 1 3.5 in Steel 1.68 in 1,069 His - - - - 0lbs Material Summary Bracing Summary TC SPF#2 2x4 W Bracing Sheathed or Pudins at 3-8-0,Path.design by others. BC SPF a2 2.4 BC Bracing Sheathed or Pudins at 10-0-0,Pudin design by0thers. Webs SPF Stud 2.4 Loads Summary 1)This toss has been designed for the e&ets of a balanced design snow load(Ps=28 psf)for hips/gables in accordance with ASCF7-10 except as noted,with the followinguser defined input:28 psfgound snow load(Pg)NOTE:All flat/sloped muff tors hme been ignored and the pound snow load has been used for the mofsnow load(Ps=PA DOL= 1.15. 2)"Ibis truss has out been designed for the e�cds ofunbalanced snow loads. 3)In addition to the snow loading specified on this drawing this truss has also been designed bra ooflise load(TOLL)ot'0 psf. 4)Minnwm storage attic loading in acconiance with®C Table 1607.1 has not been applied 5)N accordance with IBC fable 1607.1,rr ii—.BCLL's do not apply. Load Case Lrl:Std Live Load Disinblded Loads Member Lucation I location 2 Direction Spread Start Load End Load Tnb Width Top Chd I I-M 23-24) Down Poi 19.5 psf 19.5 psf 24 in Load Case Dl:Std Dead Load Distributed Loads Member Iocation 1 location 2 Direction Spread Stan Load Fnd Load Trib Width Top Chd -1-2-0 I I_" Down Rahn 3 psf 3 psf 24 in Member Forces Summary Table indicates:Member D,—CSI,rtes axis]force,(ax conpr knee ifdiff t fiom—axial force) 8-1 0.134 37166 2-3 0.407 -1,75316a 4-5 0.357 -2,010 lbs 1-2 0.392 -2,0701bs 3.4 0.406 -1,721 bs 5A 0.124 34 Ibs BC 56 0.560 1,799 Its 6-7 0.392 1,220 lb. 7-1 0.577 1,850166 Webs 2-7 0.131 454 lbs 36 0.212 493 Ibs 3-7 0.228 531 Ibs 46 0.119 413166 Notes: 1)When this miss has been chosen for quality assurance inspection,the Plate Placerneat Method per TP11-2002/A3.2 shall be used.Cq=1.17 NOTICE Acopy fthis design shall be furnished to the erection contractor The design ofthis individual truss is based no design criteria and mquvenents supplied bytheT'russ Manu&xn=and relies upon the accuracy Simpson Strung-Tie Company and corhglcteness ofthe infor®tion set forth by the Building Designer.A seal on this drawing indicates acceptance oft ofessional engineermgresponsibility solely for the truss cooponeat design s2owo.See the co� peg:and the'7uportmt Inbrmaton&C aal Notes"page for additional inbmpton.All corrector plates shall be®nuftured by Singson Strong-Ile Company,Inc in acoosdaoce with FSR-2762.All connectorplates are 20 gauge,unless the specified plate size is bllowed bya"-18"which indicates an 18 gage plate,or"S#18",which indicates a high tension 18 gauge plate. LOAD ITEMIZATION - MPi PV System Load PV Module Weight(psf) 2.5 psf Hardware Assembly Weight 0.5 psf PV System Weight 3.0 psf Roof Dead Load Material Load Roof Category Description MPi Existing Roofing Material Comp Roof (2 Layers) 5.0 psf Re-Roof No Underlayment Roofing Paper 0.5 psf Plywood Sheathing Yes 1.5 psf Board Sheathing None Rafter Size and Spacing 2 x 4 @ 24 in.O.C. 0.7 psf Vaulted Ceiling No Miscellaneous Miscellaneous Items 1.3 psf Total Roof Dead Load 9 Psf(Mpi) 9.0 Psi Reduced Roof LL Non-PV Areas Value ASCE 7-05 Roof Live Load Lo 20.0 psf Table 4-1 Member Tributary Area At :S 200 sf Roof Slope 5/12 Tributary Area Reduction Rl 1 Section 4.9 Sloped Roof Reduction R2 0.975 Section 4.9 Reduced Roof Live Load Lr Lr= Lo(Rl)(R2) E uation 4-2 Reduced Roof Live Load Lr 19.5 MPi 19.5 Psf Reduced Ground Roof Live Snow Loads Code Ground Snow Load p9 40.0 psf ASCE Table 7-1 Snow Load Reductions Allowed? Yes Snow Guards to be Installed? No Effective Roof Slope 200 Horiz. Distance from Eve to Ridge W 13.0 ft Snow Importance Factor IS 1.0 Table 1.5-2 Snow Exposure Factor 4 Fully O posed Table 7-2 Snow Thermal Factor Ct Structures kept just above freezing Table 7-3 1.1 Minimum Flat Roof Snow Load(w/ Pf-min 28.0 psf 7.3.4&7.10 Rain-on-Snow Surcharge) Flat Roof Snow Load pf pf= 0.7(Ce)(Q(I)pg; pf>_pf-min Eq: 7.3-1 28.0 psf 70% ASCE Deslan Sloped R Snow Load r Surroundina Roof Surface Condition of Surrounding Roof CS_roof All Other Surfaces Figure 7-2 Design Roof Snow Load Over Ps-.&= (Cs-roof)Pf ASCE Eq:7.41 Surrounds Roof Pr1°Of 1 28.0 psf 70% ASCE Design Sloped Roof Snow Load Over PV Modules Surface Condition of PV Modules C, m Unobstructed Sli0ppery Surfaces Figure 7-2 Design Snow Load Over PV P,."=(C¢p„)Pf ASCE Eq:7.41 Modules PAP" 28.0 psf 70% 09.23.2015 SolarCity. PV System Structural Version#49.2 Design Software PROJECT INFORMATION &TABLE OF CONTENTS Project Name: Schubach Residence AHJ: Northampton Job Number: 0101421 Building Code: MA Res. Code,8th Edition Customer Name: Schubach,Cynthia Based On: IRC 2009/IBC 2009 Address: 99 Brookwood Dr ASCE Code: ASCE 7-05 City/State: Florance, MA Risk Category: II Zip Code 01062 Upgrades Req'd? No Latitude/Longitude: 42.321257 -72.680233 Stamp Req'd? Yes SC Office:I Springfield I PV Designer: Garren Lewis Certification Letter 1 Project Information,Table Of Contents, &Vicinity Map 2 Structure Analysis (Loading Summary and Member Check) 3 Hardware Design (PV System Assembly) 4 Note: Per IBC 1613.1; Seismic check is not required because Ss= 0.22424<0.4g and Seismic Design Category(SDQ = B< D 1 2-MILE VIICINITY MAP 99 Brookwood Dr, Florance, MA 01062 Latitude:42.321257,Longitude:-72.680233,Exposure Category:C Version#49.2 . SolarGt Y September 23,2015 Project/Job#0101421 RE: CERTIFICATION LETTER Project: Schubach Residence 99 Brookwood Dr Florance, MA 01062 To Whom It May Concern, A jobsite survey of the existing framing system was performed by a site survey team from SolarCity. Structural review was based on site observations and the design criteria listed below: Design Criteria: -Applicable Codes= MA Res. Code, 8th Edition,ASCE 7-05,and 2005 NDS - Risk Category = II -Wind Speed =90 mph, Exposure Category C -Ground Snow Load =40 psf - MP1: Roof DL=9 psf,Roof LL/SL=28 psf(Non-PV Areas), Roof LL/SL= 28 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss =0.22424 <0.4g and Seismic Design Category(SDC) = B< D On the above referenced project,the components of the structural roof framing impacted by the installation of the PV assembly have been reviewed. After this review it has been determined that the existing structure is adequate to withstand the applicable roof dead load,PV assembly load,and live/snow loads indicated in the design criteria above. I certify that the structural roof framing and the new attachments that directly support the gravity loading and wind uplift loading from PV modules have been reviewed and determined to meet or exceed structural strength requirements of the MA Res. Code,8th Edition. Please contact me with any questions or concerns regarding this project. OP Digitally signed by Kyle Jackson CK5ON Date:2015.09.2309:51:36-06'00' cal CIVIL No.51873 Kyle Jackson, P.E. o 9�Q1 1E�� k4 Professional Engineer tied' T: 888.765.2489, ext. 51520 +anent email: kjackson @solarcity.com 3055 Clearview Way San Mateo. CA 94402 T(650)638-1028 (888)SOL_CITY F(650)638-1029 solarcity.com SoiarCity I ppA i r N r Customer Name and Address Installation Location Gate Cynthia Schubach 99 Brookwood Dr 99 Brookwood Dr Florence,MA 01062 Northampton,MA 01062 Congratulations! Your system design is complete and you are on your way to clean,more affordable energy.Based on the information in your System design,there are some amendments we need to make to your Power Purchase Agreement(the"PPA").The amendments are as follows: • We estimate that your System's first year annual production will be 4,460 kWh and we estimate that your average first year monthly payments will be$44.60.Over the next 20 years we estimate that your System will produce 85,096 kWh.We also confirm that your electricity rate will be$0.1200 per kWh,(i.e.electricity rate$0.1200 and tax rate$0.0000). Your electricity rate,exclusive of taxes,will never increase more than 2.90%per year. By signing below,you are agreeing to amend your PPA and you are agreeing to all of the new terms above. If you have any questions or concerns please contact your Sales Representative. Customer's Name:Cynthia Schubach Power Purchase Agreement Amendment Signature: Date: _ — SolarCity approved customers Name: Signature: Signature: Lyndon Rive, CEO Date: Date: 4/23/2015 3055 Clearview Way, Sac: Mateo,CA 94402 1 888,765,2489 1 solarcity.com Power purchase Agreement Amendment,version 2.0.1.June 25.2011 Contractor License MA HIC 168572/EL 1136MR Q .� Document generated on 9/23/2015 11.42159 1� � Jos raw [ijew; '4� CERTIFICATE OF LIABILITY INSURANCE '�'��' DBII7 @095 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON T14E CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(les)must be andotsed. If SUBROGATION 19 WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does net confer rights to the certificate holler in lieu of such andorsement(s). PRODUCER CONTACT MARSH RISK&WSURANCESERVICES -* ......_............._....................................._. PAX...._.... ..............----..........-. ...... PHONE 346 CALIFORNIA STREET,SUITE13DO u4tsti.lLa,JExtk ............................... ....__...._...._._ ......LA(c�Hs4l..-..........- ........._._.......... CALIFORNIA LICENSE NO.0437153 EMAIL SAN FRANCISCO,CA 94104 -.._. ......... .. ..._._.._.....:....... .. .......... ........ ...11...._....... .....,. Aft:Shm"SwIt 415743.8334 998301-STND-GAWUE-15-18 .INSURER A:Zwkh American insurawe Cwpeny {T16535 INSURED ............. .... ._-........................-_ ... .. ..-.......... ...... . . a�stazea.e;NIA �.NIA Solaraty Corpaahon ----- E55CfasniewWay INSURER C:_....._....NA _._................... -NIA-._ ... San Mateo,CA 94402 INSUReR p:American Zurich ItMame Canpany 40142 INSURER F: �SEtRER E COVERAGES CERTIFICATE NUMBER: SEA-0=13836.08 REVISION NUMBER:4 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THUS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. TYPE OF INSURANCE SUER POLICY NUti9)ER ues'rA A X 'COMMERCUU.GENERALUAaI.ITY 1GLOMPOIS-00 09A1P1415 !=112016 EACH OCCURRENCE S 3,00X},000 I..- _ ... ....._._.. CLAIMS-MADE I.X...OCCUR I i i t7A1(Ai'iSETbi2ER4�6....... i >EW5F5.(Eogo; nc4l_.. .s . .. 3,000,00) X SIR:S269,G00 MED.EXP(Any.one persa! S_..—.- _. --._.. _51000 ' [ PERSONAL_&_ADV INJURY Y S S 3,0DO,090 GENL AGGREGATE LiMtT APPLIES PER GEN_RALAGGR_EGAT _ _ 6,000.009 PRO- I LOC `PRODUCTS-COMP/OPAGG S fi,909,090 X POLICY L. per 1.....� OTHER: + S A AUTOMOBILE LIAMUTY HAP0182017-DO 09A12015 •09AI12016 COMRINFO SINGLE LIMIT I X.. ANY AUTO + BODILY INJURY(Per person) 8 _....._...._............_....-. X :ALL OWNED X" SCHEDULED I BODILY INJURY(Per acudem) S 'AUTOS ..__ AUTOS "_-....._...._.__.._..._ HIRED AVTCS X NON•OWNEO AUTOS .................$5,1100 COMPML DED: s UMBRELLALMa I ! 1 OCCUR EACOSOCCURtiENCE. .._.. .. S_........ . ..." EXCESS LIAR _.�.CLAIhiS-NADEI AGGREGATE S DED R Is D WORKERS COMPENSATION 00182014.00(AOS) OWN2015 09✓ 1 016 ' X , I OOH- I AND EMPLOYERS'LIABLffY .-_r .AT.t1TE.- __. I?R....-. ._-_.. _ ............._.. A YIN ANY PROPRIETORfPARTNERlEXECUTIVE 182015.01)(MA) 00112015 0941 016 N N I A EL.EACH ACCIDENT 5 1000,000 OFFICER/MEMa@R EXCLUpEP7 i....._.. ........ . .-..-..... YC DEDUCTIBLE'W,000 I kNKW ( E.L.0ISFASE-FAfMPI [$.._......_._...?.910,ao0 If Sdescnhe OF QKMT[W bgklw E.I.DISEASE.POLICY LIMIT]S 1.000,000 DESCRIPTION OP OPERATIONS I LOCATIONS r VEHOMES(ACORD 1IM,Additional Rernarla Schedule,may be attaehed Q more space Is requkedl Evidence of insurance" CERTIFICATE HOLDER CANCELLATION 3M cle iewW y SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 3955 CMM IieW Way THE EXPIRATION DATE THEREOF, NOTICE WLL BE DELIVERED IN San Mello,CA 89402 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh Risk&wAurowe Servk:u 0 1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusefts Department of IndustrialAccidents Offi'ce Of investigations I Congress Street,Suite 100 Boston,AIA 021,14-2017 ``tees www mass gowifte Workers'Compensation Insurance Affidavit:Builders/Cont tractors/EleetricianttlPlumbers Agnocant Infomation tlease print Lggffly Name,(BusinesstOrganiztdion/individual): SOLARCITY CORP Adarese.3055 CLEARVIEW WAY City/StatelZi :SAN MATEO,CA 94402 Phone#:886-765-2489 Are you an employer?Check the appropriate box: l.® I am a employer with 5480 4. Q I am a general contractor and 1 Type of project tr ctioned): cmplayces(full and/or part-titrre)part-time).* have hired the sub-contractors 6. ]Tlew construction 2.© 1 am a sole proprietor or partner- listed on the attached sheet. 7. ❑Remodeling ship and have no employees 'These sub-contractors have S. ❑Demol lfion worsting far me in any capacity. employees and have workers' [No workers'comp.insurance camp.insurance �. Building addition t required.] 5. 0 We arc a corporation and its 10.[]Electrical repairs or additions 3.❑ 1 am a homeowner doing all work officers have exercised their 1 IQ Plumbing repairs or additions myself. [No workers' comp, right of exemption per MGL 12.[]Roof repairs insurance required.]t c. 152,§1(4),and we have no SOLAR/PV employees.[No workers' 13.-Other comp.insurance required.] 'Any applicant that ohectet box#I must also rill out the strtion bolo►v shuwlag lbeir tvot6srs'eonhpensation policy ithrottnaiion, t ilwmowners who sttbmk ihts affidavit inaleagag they are dais all wnrk Had then hire outside contr ors must submit anew aflHdavk indicalhig such, tCantractors that Oeck this box nrut attached oo additional sheet showiaa the name or the subcontractors and sutra whether at not tbosc enthies have cm0oycca. tf thosub-amttecton hm ernployeas,Choy must providetheir workers'comp.policy number, I min an mVtoyer that b provIONg workers'congrensadon insurance,jar my ear playem Below is the perks'and jub site information. Insurance Company Name: Zurich American Insurance Company Policy it or Self-ins.L' il: WC0182014-00 Expiration Date: 09/01/2016 Job Site Address: b0dmd Or Gity/State/Zip: U/ n oug Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MOL c.152 can lead to the imposition of criminal penalties of a fire up to$1,500.00 and/or one-year imprisonmont,as well as civil penalties in the fonn of a STOP WORK ORDER and a fine of up to$250.110 a day against the violator. Be advised that a copy of this statement may be forwarded to the Of-rice of Investigations ofthe DIA for insurance coverage verification. !rla hereby certify antler the pains rrrrd penalfies of perJerry f/af the hrJorxraFiorr provltJetl above is true and correct. Signature: Mug#: t?,;Qkkd*se only. Do not write in this area,to he completed by city or town offiefol. City or Town: Perinit/License 4- Issuing Authority(circle one): 1.Board ofSealth 2.Building Department 3.Cily/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder:SOLARCITY/CRAIG ELLS 107663 License Number 604 SILVER ST AGAWAM MA 01001 8/29/17 Addre Expiration Date (-AAA-/ F a,", 978-875-1698 Signature Telephone 9.Reaistered Home Improvement Contractor: Not Applicable ❑ SOLARCITY CORP/VICTORIA JUNCK 168572 Company Name Registration Number 604 SILVER ST AGAWAM MA 01001 03/08/2017 Addres _ Expiration Date Telephone 978"215-2367 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(90 Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... ❑ No...... ❑ 11. - Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153(Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature SECTION 5-DESCRIPTION OF PROPOSED WORK(check all apolicablel New House Addition Replacement Windows Alteration(s) Roofing Or Doors Accessory Bldg. Demolition New Signs [ ] Decks [ ] Siding[ ] Other Brief Description of Proposed Work: Install solar electric panels to roof of existing home,to be interconnected with home's electrical system. Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building :One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Cynthia Schubach as Owner of the subject property hereby authorize SOLARCITY to act on my behalf, in all matters relative to work authorized by this building permit application. 10/01/15 Signature of Owner Date I, SOLARCITY CORPNICTORIA JUNCK as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. SOLARCITY CORPNICTORIA JUNCK Print Na e 10/01/15 Signature of Owner/Agent Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size t; �x Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage % Open Space Footage % (Lot area minus bldg&paved parking) #of Parking Spaces Fill: volume&Location A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO DONT KNOW YES IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO DONT KNOW YES IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO DONT KNOW YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained , Date Issued: C. Do any signs exist on the property? YES NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,excavation,or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES NO IF YES,then a Northampton Storm Water Management Permit from the DPW is required. Department use only f Northampton Status of Permit: j ng Department Curb Cut/Driveway Permit Main Street Sewer/Septic AvailabiliRoom 100 Water/Well Availability pton, MA 01060 Two Sets of Structural Plans lambing 1240 Fax 413-587-1272 Plot/Site Plans Van Other Specify APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office 99 Brookwood Dr Map Lot Unit Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Cynthia Schubach 99 Brookwood Dr,Florence MA 01062 Name(Print) Current Mailing Address: 413-586-4245 Telephone Signature 2.2 Authorized Agent: SolarCity CorpNictoria Junck 604 Silver St Agawam MA 01001 Name(Print) — Current Mailing Address: 978-215-2367 nature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by ermit applicant 1. Building 3,000 (a)Building Permit Fee 2. Electrical ct.T (b)Estimated Cost of Construction from 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) 5. Fire Protection 6. Total=0 +2+3+4+5) 12,!,5700)1 Check Number This Section For Official Use Only Building Permit Number: Date Issued: Signature: Building Commissioner/inspector of Buildings Date 3 /� File#BP-2016-0457 APPLICANT/CONTACT PERSON SOLARCITY CORP ADDRESS/PHONE 604 SILVER ST AGAWAM01001 (888)765-2489(2358) PROPERTY LOCATION 99 BROOKWOOD DR MAP 29 PARCEL 394 001 ZONE THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid 7 009t V75 Building Permit Filled out Fee Paid Typeof Construction: INSTALL ROOF MOUNTED 4.16 KW SOLAR ARRAY New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 095884 3 sets of Plans/Plot Plan THE FOLLOW G ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFOR ON PRESENTED: proved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management la Signature of fiuilding Officia Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of Planning&Development for more information. 99 BROOKWOOD DR BP-2016-0457 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 29-394 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR PANELS BUILDING PERMIT Permit# BP-2016-0457 Project# JS-2016-000754 Est. Cost: $12500.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: SOLARCITY CORP 095884 Lot Size(sg.ft.): 10018.80 Owner: SCHUBACH CYNTHIA M Zoning: Applicant. SOLARCITY CORP AT. 99 BROOKWOOD DR Applicant Address: Phone: Insurance: 604 SILVER ST (888) 765-2489 (2358) Workers Compensation AGAWAMMA01001 ISSUED ON.•1011912015 0:00:00 TO PERFORM THE FOLLOWING WORK.-INSTALL ROOF MOUNTED 4.16 KW SOLAR ARRAY POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 10/19/2015 0:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner