Loading...
25-015 (63) INSTALLATION INSTRUCTIONS Smart VENT & DETAILS 877- 441 - 8368 MODEL 1540-520 www.smartvent.com FLOODVENT INSULATED INSTALLATION INSTRUCTIONS REV. 5-15-09 1. Remove vent door from vent frame. (Turn upside down,rotate bottom of door outward and slide out) 2. Prepare a CLEAN 16.25"wide by 8.25"high rough opening(approx. 1 block wide X 1 block high) for each vent. Ensure the bottom of the rough opening is no more than 12" above the finished grade. 3. Apply a bead of silicone or polyurethane caulk around the back of the flange on the vent frame. (FIG. 2) 4. Bend the 4 steel straps to the thickness of the wall measuring from the end with the teeth (see STRAP DETAIL) 5. Insert the top straps into the top two strap slots about two clicks. 6. Insert the vent frame in the cut opening. The bent strap ends go in then up behind the inside of the wall. Push the frame tight against the face of the wall. Ensure the frame is flush and square in the opening. (FIG. 3) 7. Reach through the vent opening and click the two straps in while holding the front of the vent against the wall face. The sharp point of the straps should not extend past the front of the vent face. Install the two remaining bottom straps and click into place. 8. Re-check that frame is square and slots are clear of debris, and caulk. 9. Install the door into frame by grasping the bottom of door(with float pins down)and front(weld marks back). Slide door into frame and rotate until it is latched. 10. To open the door insert two credit cards into the float slots as shown in the diagram. This will unlatch the door for removal and cleaning. DETAIL SPECIFICATIONS: MATERIAL: STAINLESS STEEL OPERATION: AUTOMATIC NON—POWERED ACTIVATION AND OPERATION INSTALLATION: SECURED W/ 4 STAINLESS STEEL STRAPS SUPPLIED HYDROSTATIC RELIEF: 200 Sq. Ft per Vent REQUIREMENTS: MINIMUM OF 2 VENTS PER ENCLOSED AREA MOUNTED ON AT LEAST TWO DIFFERENT WALLS COLORS: STAINLESS (STANDARD) EXTERIOR POWDER COATED WHITE, WHEAT, GRAY, AND BLACK (AVAILABLE) MEETS THE REQUIREMENTS FOR ENGINEERED OPENINGS AS SET FORTH BY: FEMA,NFIP,ICC,&ASCE SUPPORTIVE DOCUMENTS,TB 1-08,44CFR 60.3(C)(5),ASCE 24-05 ICC EVALUATION #ESR-2074 SHEET 2 OF 2 DETAIL DIAGRAM Smart VENT MODEL 1540-520 877- 441 - 8368 FLOOD VENT INSULATED www.smartvent.com 16 1/4" R/❑ — STRAP SLOTS USE TWO TOP AND TWO BOTTOM 0 FLOAT SLOTS SILICONE/POLYURETHANE L❑CATI❑N (FLANGE) FIGURE 1 ° Front View STRAPS INSTALLED, TWO ON TOP TWO ON ° VENT BOTTOM DOOR VENT FRAME STRAPS FIGURE 2 a ° Side View FIGURE 3 FINAL GRADE �a Side View Is �77 IF SMART VENT Foundation Flood Vents 1� TOLERANCES UNLESS 450 AndBro Dr. Suite 2B STRAP DETAIL. I BEND TO WALL 8 0 OTHERWISE SPECIFIED Pitman NJ 08071 TEETH MUST CLICK IN TIGHT TO —� THK. x.x +i-o,oe SMART VENT® INSURE SECURE INSTALLATI❑N, x.xx +/-0,03 877-441-8368 FLOOD VENT INSULATED x.xxx +i-o.00s BEND PAST 90° FO WWW.SMARTVENf.COM MODEL 1540-520 SPRING BACK THE INFORMATION CONTAINED IN THIS DRAWING °"'� NO. 1540-5IS THE SOLE PROPERTY OF SMART VENT,INC.IF USED IN PROJECT,CHANGES TO DRAWING ARE PROHIBITED WITHOUT THE WRITTEN PERMISSION OF SMART VENT INC. �SIZE . 5-15-09 SHEET 1 OF 2 FULFAB, INC . EC-E 0-Y.-E- H,MGAR,S" ........... - "Y' SEP 2 8 2015 Plumbing Northampto� af n$ WIT 201-5 Faew'c� Mr, Ron Hannah Seven Bravo Two, LLC 160 Old Ferry Rd Northampton, MA 01060 RE: Hangar Building Northampton Airport Northampton, MA Dear Mr. Hannah: This letter is in response to your questions regarding building drainage in the event of a flood at the airport. There are six bifold doors which are 42'0" wide in the hangar building. The bottom of the bifold door frame is approximately 2"above the ground. This gap is closed with a vinyl bulb seal when the door is in the down position. In addition, the interior partition walls are installed above floor level per our standard design. In the event of a flood, any water should enter the building under the bifold doors and either back out or across the building and out the other side. Very truly yours, FULFAB, INC. E. Michael Paris P.E, 1525 Whipple Avenue, S.W. * Canton, Ohio 44710 * (330)477-7211 * FAX(330)478-3863 LlMassachusetts Department of Environmental Protection DEP File Number: Bureau of Resource Protection -Wetlands 6 SS( I WPA Form 7 — Extension Permit for Orders of Conditio Provided by DEP Massachusetts Wetlands Protection Act M.G.L. c. 131, §40 _ I IIIIIIIIII A. General Information IIIIIII IIIIIIIIII IIIII 111111 1111111 III III (IIIIIIIIII II 0 2 Important: When filling out 1. Applicant: Bk: 12069Pg:264 Page: 1 of 2 forms on the Recorded: 09/16/2015 03:18 PM — computer, use e only the tab a I key to move s ailing Addr your cursor- � do not use the return key. i own �� <,. , I State Zip Code 2. Property Owner(if different): ,U SEP 1 $ Name Efectri Pnr Mailing Address City/Town State Zip Code B. Authorization The Order of Conditions (or Extension Permit) issued to the applicant or property owner listed above on: ?.e C. Issued by: Date �-- Conservatio Coi on (Cj, for work at: Street Address �— Assessors Number P ce/Lo Number record ad at the Registry of Deeds for: Q / IAAAdTIA 1rO � U f� �co ty 3� Certificate(if registered land) is hereby xtended until: ` 'Um - y Date Datt the Order was last exterif applicable) This date can be no more than 3 years from the expiration date of tftolr4gr of Conditions or the latest__._ - extension. Only unexpired Orders of Conditions or Extension may betX%�Nded. This Extension Permit must be signed by a majority of the.Con5eN0Vo1\t.Wn tvt,►orland aL"py the applicant and the appropriate DEP Regional Office(httax/- -Y, mass QoV/deo/ab6ut/reciii . �indvo Ar.htm) 2 Si nat res: Date ` C wpaformTdoc•rev.3/1/2010 Page 1 of 2 ' Sh-urturat EngineuHng ConsuttuntS RK VVHITE SEP 8 N15 ,'„a� St}Railroad Avenue ENGINEERING, L.L� ._.J Southington,CT 06489 Electric, Plumbing 8,Gas.ii;spections (860)276-9100 Northampton,MA 01060 FAX, email:rkingwhite@aol.com September 16,2015 Ron Hannah Senior Project Manager One Development&Construction, LLC 68 Union Street Westfield,MA 01085 RE: Proposed"T”Hanger Project located in a 100 year flood Lane Dear Ron, have reviewed our foundation plans and details_ Our footings and piers will be adequate for Proposed and assumed loading. The light gauge t au a nature of the wall structure and the bl-fold nature of the large e overhead doors makes installing;mechanical louvers impractical at best. By lifting the massive 42' bi-fold door,even 6" will allow more equalizing of water pressure than several louvers would have accomplished. Even if the flooding occurs with no one around,the doors do not fit tight to the concrete sill allowing flooding to enter the hangar spaces, It is essential that all occupants be advised of the flooding potential and encouraged to keep all tools,equipment and electrical equipment four(4')feet off the floor. If l can be of further service,please call me at 860-276-9100. Very truly yours, , IVA OF RICHAR f WHIT TFi11Gril AL Richard K. White, PE } ° NO,46752 RX, White Engineering,LLC ``c 9e i '0 SAL The Commonwealth of Massachusetts Department of Industrial Accidents U Office of Investigations d 1 Congress Street, Suite 100 Boston, MA 02114-2017 www mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): ELM ELECTRICAL INC. Address: 68 UNION STREET City/State/Zip: WESTFIELD, MA 01085 Phone#: 413-568-0905 Are you an employer? Check the appropriate box: Type of project(required): 1.[9 I am a employer with 4. E] I am a general contractor and I employees (full and/or part-time).* have hired the sub-contractors 6. ❑New construction 2.[ I am a sole proprietor or partner- listed on the attached sheet. 7. [Remodeling ship and have no employees These sub-contractors have g. [ Demolition working or me in an capacity. employees and have workers' g Y $ 9. 0 Building addition [No workers' comp. insurance comp. insurance. required.] 5. E] We are a corporation and its 10.2 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their I LE] Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t c. 152,§1(4),and we have no employees. [No workers' 13.❑ Other comp. insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. tContractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: MASSACHUSETTS EMPLOYERS INSURANCE COMPANY Policy#or Self-ins. Lie. #: WMZ-800-8006834-2014A Expiration Date: 711/2016 Job Site Address: ALL JOBS IN City/State/Zip: Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certi y under the pains and penalties of perjury that the information provided above is true and correct. Si nature: Date: ZI 15 Phone#: 413-568-0905 Official use only. Do not write in this area, to be completed by city or town official. City or Town: Permit/License # Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: milli Planning Board - Decision City of Northampton Hearing No.: PLN-2006-0063 Date:July 25, 2006 FILING DEADLINE MAILING DATE: HEARING CONTINUED DATE: DECISION DRAFT BY: APPEAL DATE: 6/22/2006 71612006 7/13/2006 REFERRALS IN DATE: HEARING DEADLINE DATE: HEARING CLOSE DATE: FINAL SIGNING BY: APPEAL DEADLINE: 612912006 811812006 711312006 712712006 811412006 FIRST ADVERTISING DATE: HEARING DATE VOTING DATE DECISION DATE: 612912006 711312006 711312006 712512006 SECOND ADVERTISING DATE: HEARING TIME: VOTING DEADLINE: DECISION DEADLINE: 71612006 8:55 PM 711312006 7/27/2006 MEMBERS PRESENT: VOTE George Russell votes to Grant Frances Volkmann votes to Grant Jennifer Dieringer votes to Grant Paul Voss votes to Grant George Kohout votes to Grant Keith Wilson votes to Grant Kenneth Jodrie votes to Grant David Wilensky votes to Grant MOTION MADE BY: SECONDED BY: VOTE COUNT: DECISION: Keith Wilson George Russell 8 Approved MINUTES OF MEETING: Available in the Office of Planning 8 Development 1, Carolyn Misch,as agent to the Planning Board, certify that this is a true and accurate decision made by the Planning Board and certify that a copy of this and all plans have been riled with the Board and the City Clerk on July 25,2006. 1 certify that a copy of this decision has been mailed to the Owner and Applicant Notice ofAppeal An appeal from the decision of the Planning Board may be made by any person aggrieved pursuant to MGL Chapt 40A,Section 17 as amended within twenty(20)days after the date of the riling of the notice of the decision with the City Clerk The date is listed above. Such appeal may be made to the Hampshire Superior Court with a"certified copy of the appeal sent to the City Clerk of the City of Northampton. GeoTMS®2006 Des Lauriers Municipal Solutions,Inc. Planning Board - Decision City of Northampton Hearing No.: PLN-2006-0063 Date:July 25, 2006 APPLICATION TYPE: SUBMISSION DATE: Amendment to Permit 611412006 Applicant's Name: Owner's Name: Surveyor's Name: NAME: NAME: COMPANY NAME: Robert Bacon Northampton Airport Inc. ADDRESS: ADDRESS: ADDRESS: Northampton Airport PO Box 878 P.O.Box 878 TOWN: STATE: ZIP CODE: TOWN: STATE: ZIP CODE: TOWN: STATE: ZIP CODE: NORTHAMPTON MA 01060 NORTHAMPTON MA 01060 PHONE NO.: FAX NO.: PHONE NO.: FAX NO.: PHONE NO.: FAX NO.: EMAIL ADDRESS: EMAIL ADDRESS: EMAIL ADDRESS: Site Information: STREET NO. SITE ZONING: 152 CROSS PATH RD SC TOWN: SECTION OF BYLAW: NORTHAMPTON MA 01060 Section 11:Site Plan Approval MAP: BLOCK: LOT: MAP DATE: ACTION TAKEN: 25 015 001 Approved Book: Page: 2386 155 NATURE OF PROPOSED WORK: Amend site plan approval to change hanger sizes and types. HARDSHIP: CONDITION OF APPROVAL: FINDINGS: The Planning Board approved the modification of the site plan for a change in the size and type of airplane hangars based upon the following plans submitted with the application: 1. "Proposed Conditions Plan"Northampton Airport Prepared by.Baystate.Environmental Consultants,inc.,dated May 19,2004,change #4 dated 6113106. The Planning Board approved the change of the original site plan only for the alteration of building sizes and orientation. All other aspects of the original plan stand. The Board found that. 1.The requested use protects adjoining premises against seriously detrimental uses. The modified building size will not change the original permit Conservation Commission will review the alterations relative to conformance with flood storage capacity. 2.The requested use addresses safety of vehicular and pedestrian movement within the site and on adjacent streets. There will be no significant changes over original permit 3.The requested use will promote a harmonious relationship of structures and open spaces to the natural landscape,existing buildings and other community assets in the area. 4.The requested use will not overload,and will mitigate adverse impacts on,the City's resources including the effect on the City's water supply and distribution system,sanitary and storm sewage collection and treatment systems,fire protection,streets and schools. 5. The requested use does not trigger compliance with special regulations set forth in the Zoning Ordinance other than for site plan review. 6.Compliance with the following technical performance standards have been met: A.Additional curb cuts are not required. B.Pedestrian,bicycle and vehicular traffic movement on site are separated. C.The applicant will mitigate stormwater as addressed in original permit COULD NOT DEROGATE BECAUSE: GeOTMS®2006 Des Lauriers Municipal Solutions,Inc. Planning Board - Decision City of Northampton Nearing No.: PLN-2004-0091 Date:July 2,2004 1,Carolyn Misch,as agent to the Planning Board,certify that this Is a true and accurate decision made by the Planning Board and certify that a copy of this and all plans have been Fled with the Board and the City Clerk on July 2,2004. 1 certify that a copy of this decision has been mailed to the Owner and Applicant. ® E � CO � C ��I ( JUL 2 2004 CITY CLERKS OFFICE NORTHAMPTON MA 01060 July 23 , 2004 I, Wendy Mazza, City Clerk of Northampton, hereby certify that the above Demision of the Northampton Planning Board was filed in the Office of the C. Clerk on July 2, 2004 , that twenty days have elapsed since such filing and that no appeal has been filed in this "it Attest: 0...# City Clerk City of Northampton GeoTMS 6 2004 Des Lauriers Municipal Solutions,Inc. ATTEM.' HAMPSHIRE, 001�� 190.19TER 44ARIA*ft L. DOId4 ' Planning Board - Decision City of Northampton Hearing No.: PLN-2004-0091 Date:July 2,2004 1.,Existing Conditions Plan"Northampton Airport,prepared by Baystate Environmental Consultants,Inc, Sheet 1 of 2,dated May 19, 2004. 2. "Proposed Conditions Plan"Northampton Airport,prepared by Baystate Environmental Consultants,Inc, Sheet 2 of 2,dated May 19, 2004,revised June 10,2004. 3.'Northampton Airport Site Ratios" submitted with application and revised June 10,2004. The Board granted the Special Permit and Site Plan upon finding that the following criteria within the zoning had been met. A. The requested use protects adjoining premises against seriously detrimental uses. Surface water drainage will be collected on site in dry wells. Continued use of this property for an airport will allow a sign cant portion of the meadows to remain open thereby preserving sight buffers and views of the Holyoke Range. The airport will institute voluntary noise abatement to minimize sound impacts on the community;and B.The requested use will promote the convenience and safety of vehicular andpedestrien movement within the site and on adjacent streets,minimize traffic impacts on the streets and roads in the area. No changes to access driveway openings are planned. Minimal increases in air traffic are planned and will not Increase automobile traffic on surrounding streets during peak periods. Access by emergency vehicles,the arrangement ofparking and loading spaces,and provisions for persons with disabilities will be maintained;and C.The requested use will promote a harmonious relationship of structures and open spaces to the natural landscape,existing buildings and other community assets In the area. The new structures proposed will be clustered within the developed portion of the property and thereby preserve the remaining land as open field and runway. The portion of land owned by Northampton Airport on the Connecticut River will be permanently protected as open space through a Conservation Restriction;and D.The requested use will not overload,and will mitigate adverse impacts on,the City's resources Including the effect on the City's water supply and distribution system,sanitary and storm sewage collection and treatment systems,fire protection,streets and schools. No additional service demands will be required;and E.The requested use meets all the special regulations set forth!n the Zoning Ordinance for the dedication of land in order to obtain a reduction in open space.The Board granted the Improvements shown on the Site Plan with the condition that all criteria for construction within the fioodplain be met and technical standards be reviewed by the Northampton Conservation Commission. .The requested use bears a positive relationship to the public convenience or welfare. The continued use of the property as a general aviation airport provides an important link In the City's overall transportation network and provides residents with a unique resource. The use will not unduly impair the integrity of character of the district or adjoining zones,nor be detrimental to the health,morals,or general welfare. The use shall be In harmony with the general purpose and Intent of the Ordinance;and G.The requested use will promote City planning objectives to the extent possible and will not adversely effect those objectives,as defined In The City of Northampton Open Space and Recreation Plan 2000-2004 adopted under M.G.L Chapter 41,Section 81-C and D. The plan identifies the need for preservation of Important natural resource areas along the Connecticut River and to provide future potential access to the River. The land extensive nature of the airport use enables vast portions of land within the Meadows to remain open for flood storage,habitat and wildlife corridors. COULD NOT DEROGATE BECAUSE FILING DEADLINE: MAILING DATE: HEARING CONTINUED DATE: DECISION DRAFT BY: APPEAL DATE: 512012004 6/3/2004 7//2004 REFERRALS IN DATE HEARING DEADLINE DATE: HEARING CLOSE DATE: FINAL SIGNING BY: APPEAL DEADLINE: 5/2712004 7125/2004 611012004 7/8/2004 7/22/2004 FIRST ADVERTISING DATE: HEARING DATE: VOTING DATE: DECISION DATE: 5/27/2004 611012004 6/24/2004 71212004 SECOND ADVERTISING DATE: HEARING TiME: VOTING DEADLINE: DECISION DEADLINE: 61312004 7.00 PM 91812004 9/8/2004 MEMBERS PRESENT: VOTE: Wllllam Letendre votes to Grant Francis Johnson votes to Grant George Kohout votes to Grant "AA Keith Wilson votes to Grant Kenneth Jodrle votes to Grant David Wrlensky votes to ineligible to Vote AOTION MADE BY: SECONDED BY: VOTE COUNT. DECISION: 1 �111am Letendre Kenneth Jodrle 5-1 Approved with Conditions MINUTES OF MEETING: Available in the Office of Planning 8 Development. GOOTMS®2004 Des Lauriers Municipal Solutions,Inc. Planning Board - Decision City of Northampton Hearing No.: PLN-2004-0091 Date:July 2,2004 9.Storagelwarehousing of vehicles unrelated to the use or function of the airport are not allowed on site,including within the hangar buildings. 10. No residential use of the property Is allowed. 11. AM NPDES permits must be obtained. s 12.Events with attendance below 301 and which do not entail advertising shall be considered accessory to the airport and are allowed without further review. 13. Except.for the Balloon Festival,advertised special events,aviation related or otherwise,are not granted In this special permit. 14. The following conditions shall apply to the Balloon Festival: a. The applicant shall provide notice of the planned Balloon Festival to residents and landowners In the Meadows on:Riverbank Road, Cross Path Road,Fair Street Fair Street Extension, and Old Ferry Road by mailing notice forty-five(45)days In advance with time of event (e.g.,11 AM-7PM),expected attendance,and contact numbers for complaints or concerns during the events b. Maximum attendance for the entire length of the Balloon Festival may not exceed 10,000. c. The applicant shall take measures to keep the audience out of the agricultural fields. d.The applicant shall comply with all recommendations of the Northampton Police Department and the License Commission with regard to alcohol. e.The applicant shall provide notice to the Northampton Police Department,Northampton Fire Department and Emergency Medical Services forty-five days(45)in advance of the balloon festival. F Written sign off must be obtained from the Northampton Police Department Indicating review and approval of a traffic management/controf and a security plan-in advance of each event. If sign off has not been obtained,the event will not be allowed. g. Written sign off must be obtained from the Northampton Fire Department.If sign-off has not been obtained,the event will not be allowed. The following criteria applies. 1.Attendance at any time of 1,500—2,999 people requires one Are department personnel. 2.Attendance at any time of 3,000—4,499 people an ambulance and 2 Fire Department personnel will be required. 3.Attendance at any time of 5,000+people requires an engine company and 4 Fire Department personnel. h. It shall be the applicant's responsibility to ensure that all other necessary permits for the balloon festival are In place,including but not limited to the securing of appropriate permits from the Building and Health Departments by/for all participants and vendors. L All public roads are to remain unobstructed at all times to residents,farmers and their guests. Security,hired by the applicant,shall be posted in accordance with plans required and approved by the Northampton Police Department j. There shall be no parking for the balloon festival allowed on public roads or private property unless approved by the property owner. Aggressive towing shall be implemented,through the airports initiation. k. Temporary No-Parking Signs with Tow Zone shall be posted a day ahead of each event along the sides of all public ways leading to the airport from the Fairgrounds property to the airport and along Cross Path Road and surrounding streets. L Spectator vehicles,other than designated"balloon chase"or other required aviation related event vehicles shall be restricted from entering the meadows and roads,if approved in traffic control plan by the Police Department. If approved,adequate security with established mechanism to enforce this condition shall be posted on either end of the airport to prevent non-resident spectators from entering these areas during balloon festival events. m.Required chase vehicles shall be kept to a minimum. n. Noise levels shall comply with the environmental standards in the Northampton Zoning Ordinance,to be measured at the property line and lowered If too loud. This shall be self- monitored by the applicant with enforcement by the Zoning Enforcement Officer. o.AN trash must be picked up within twenty-four hours after the festival. p.The applicant shall make all efforts to avoid conflicts with events taking place at the fairgrounds or activities at Sheldon Field. The Northampton Police Department shall make the final decision about any scheduling conflicts. The Northampton Planning Board unanimously GRANTED the request for a Special Permit with Site Plan(major project)under the ovislons of Sections 5.2,6.2,6.3,10&13 of the Northampton Zoning Ordinance for establishment of an airport within the SC district, i :panslons Including substantial improvements of greater than 15%value,land dedication for reduction of required open space to allow f the current non-conforming open space of 81.5%to remain as shown on the following plans and information submitted with the application and as amended by any conditions attached to this permit. IGeoTMS®2004 Des Laurlers Municipal Solutions,Inc. Planning Board - Decision IIIIIIIIIIIIIII IIII II till(II II IIII EIII{IIEIIII[I City of Northampton Hearing No.: PLN-2004-0099 B Date:July 2,2004 k:7944Pg:212 Page: 1 of 4 APPLICATION TYPE: SUBMISSION DATE: Recorded: 08l12/2004 12:55 PM PB Special Permit with Major Site PI 5/21/2004 A plicarift Name: Owner's Name: Surveyor's Name: NAME: NAME: COMPANY NAME: Robert Bacon&Lisa Fusco NORTHAMPTON AIRPORT INC ADDRESS: ADDRESS: ADDRESS: 26 Hedge Row Lane P O BOX 878 TOWN: STATE: ZIP CODE: TOWN: STATE: ZIP CODE: TOWN: STATE:.. ZIP CODE. AMHERST MA 01002 NORTHAMPTON MA 010061 PHONE NO.: FAX NO.: PHONE NO.: FAX NO.: PHONE NO.: FAX NO.: (413)584-7980 0 EMAIL ADDRESS:, EMAIL ADDRESS: EMAIL ADDRESS: Site Information: STREET NO.: SITE ZONING: 152 CROSS PATH RD SC TOWN: SECTION OF BYLAW: NORTHAMPTON MA 01060 Section 6.3:Reduction of Dlmenslonal and Density Regulations MAP: BLOCK LOT: MAP DATE: ACTION TAKEN: 25 015 001 Approved With Conditions Book Page: 2386 155 N NATURE OF PROPOSED WORK: , Demolition,reconstruction and new construction of buildings for office and hangar space,fuel pad and apron paving. Identification of 'ure hangar expansloWbuild--out Permit includes Map ID 25-15,16, 17,19,71,53;26-1. ,OSHIP: (-Co NDITION OF APPROVAL: 1.The Special Permit is for the use of the Northampton Airport and expansions shown on the plans. Any runway extension requires amendments. 2. The Airport shall institute and maintain a voluntary flight noise abatement program. 3.Prior to request for a building permit,the applicant must provide proof that a permit has been V issued by the Conservation Commission showing that all requirements for flood storage,building g elevations,flood proofing,stormwater management have been met 4. A copy of a FEMA flood elevation certlflcatlon must be provided at the time that a request for building permit is made. 5. This permit allows up to 3.9 acres of land along the Connecticut River to be swapped for construction on the airport property in conjunction with the long range buildout plans shown on Plan Sheet 2 of 2 dated June 10,2004 by Baystate Environmental Consultants unless otherwise amended. Such construction may only occur after recording of conservation easement documents on the land as offered by the applicant and approved by the Office of Planning&Development indicating that no more land area is developed than that which is placed under permanent conservation restriction. All land presented for dedication by the applicant must have the CR signed by the owner. The CR shall not allow storage of any vehicles,or structures. Vehicles Include registered and unregistered. 6.Prior to any airport expansion,the applicant must obtain the approval of a Conservation Restriction by the Conservation Commission, City Council and the Secretary of the Executive Office of Environmental Affairs that will remain in effect In perpetuity for that property being transferred. This must occur within nine(9)months of the expiration of the appeal period of the Special Permit The Office of Planning B Development Is available to assist In this effort 7.Prior to issuance of certificate of occupancy for any of the new hangars,all existing buildings and new buildings shall be connected to underground dry wells)to collect roof runoff. 8.All skydiving trailers must be registered with the Registry of Motor Vehicles,unless building permits are obtained,and must be relocated on the lot so that they are not within the setback areas. GeoTMS®2004 Des Lauriers Municipal Solutions,Inc. �`' tea' '• is � t �.,. a � sH•-�a � . City of Northampton Date:June 14,2004 ILD 140T DEROGATE BECAUSE: FILING DEADLINE: MAILING DATE. HEARING CONTINUED DATE: DECISION DRAFT BY APPEAL DATE: 512012004 613/2004 612312004 REFERRALS IN DATE: HEARING DEADLINE DATE: HEARING CLOSE DATE! FINAL SIGNING BY, APPEAL DEADLINE: 51271.2004 712512004 611012004 612412004 71412004 FIRST ADVERTISING DATE' HEARING DATE: VOTING DATE: DECISION DATE: 512712004 619012004 &!1012004 6/1412004 SECOND ADVERTISING tIATE: HEARING TIME: VOTING DEADLINE: DECISION DEADLINE. 61312004 7.•05 PM 91812004 612412004 MEMBERS PRESENT: VOTE: Sara Northrup votes to Grant t Makolm B.E Smith votes to Grant t Bob Riddle votes to Grant !!!! MOVON MADE BY: SECONDED BY: VOTE COUNT` DECISION: Malcolm S.E.Smith Sara Northrup 3 Approved with Conditions MINUTES OF MSETING: Available in the Ogee of Planning&Development, t !,Carolyn kisch,as agent to the Zoning!Board of Appeals,certify that this is a true and accurate decision made by the Zoning Board of 111 Appeals and certify that a copy of this and ail plans have been filed with the Board and the City Clerk on .tune 14,2004. 1� I certifyfiat(a copy of this decision has been mailed to the Owner and Applicant JUN 1 4 2004 CITY CLEF;,,S OFFICE &10RTHA&wTMtj, MA 01060 July 5 , 2004 ,Wendy Mazza, City Clerk of the City of Northampton, hereby certify that the Bove Decision of the Northampton Zoning Board of Appeals was filed in the tch fice of the City Clerk on June 14 , 2004 , that twenty days have elapsed since filing and that no appeal has been filed in this matter. Attest: City Clerk City of Northampton GeoTMS(D 2004 Des Lauriers Municipal Solutions,Inc. ATTEST:HAMPSHIRE, MARIANMi L. DONQH YP City of Northampton Date:June 14,2004 Bk:7944Pg:210 Page: 1 of 2 APPLICATION TYPE: SUBMISSION GATE: Recorded: 08112/2004 12:56 PM ZBA-Finding 512112004 Applicant's Name: Owner's Name: Surveyor's Name: NAME: NAME: COMPANY NAME: Robert Bacon&Lisa Fusco NORTHAMPTON AIRPORT INC ADDRESS: ADDRESS: ADDRESS: 26 Hedge Row Lane P O BOX 878 TOWN: STATE: ZIP CODE: TOWN. STATE: ZIP CODE: TOWN: STATE ZIP CODE: AMHERST MA 01002 NORTHAMPTON MA 010061 PHONE NO.: FAX NO.: PHONE NO.: FAX NO:: PHONE NO.: FAX NO.: (413)584.7980 0 EMAIL ADDRESS: EMAIL ADDRESS: EMAIL ADDRESS. Site Information: STREET NO.: SITE ZONING: 152 CROSS PATH RD SC TOWN: SECTION OF BYLAW: \ NORTHAMPTON MA 01060 Section 9.3(1)(D):Pre-existing Nonconforming Structures or uses May be Changed,Exten \ MAP: BLOCK I LOT. MAP DATE TAKEN: 25 015 001 Approved With Conditions INBook: Page: 2388 155 �C NATURE OF PROPOSED WORK: +remofition of existing buildings,recontruction of one building,construction of 7500 sq.ft ofgcelhanger bldg.install fuel pad,paving. (� nperty also includes Map ID 25-71,53 and 26-1. CONDITION OF APPROVAL• 1.Prior to any airport expansion,the applicant must obtain the approval of a Conservation ResWctionlpublic Right-of-Way Easement by the City Council and the Secretary of the Executive Office of Environmental Affairs that will remain in effect In perpetuity for the property being offered. This must occur within nine(9)months of the expiration of the appeal period of the Planning Board Special Permit The Office of Planning&Development is available to assist in this effort.. The Zoning Board ofAppeals granted the Finding for expansion based upon the following plans submitted with the application: 1.'Existing Conditions Plan'Northampton Airport,prepared by Baystate Environmental Consultants,Inc, Sheet 1 of'2,dated May 19,2004 2. 'Proposed Conditions Plan"Northampton Airpor4 prepared by Baystate Environmental Consultants,Inc, Sheet 2 of 2,dated May 19, 2004,revised June 10,2004. 3."Northampton Airport Site Ratios` submitted with application and revised June 10,2004. The Zoning Board of Appeals granted the Finding for expansions on a site with pre-existing non-,conforming open space upon determination of the following. 1. The change, expansion or alteration to a pre-existing non-conformity will not be substantially more detrimental to the neighborhood than the existing nonconforming nature of the structure,tot and or use. The airport will eliminate the non-conforming use by obtaining a special permit from the Planning Board.-A land dedication along the COnnecticuft River will Improve overall quality of open space within the areaa. Z The change does not increase the non-conforming nature of the property. The plans submitted indicate that the non-conforming open space Is 81.5%(95%is required}and the proposed expansions would maintain the open space at 81.5%. 3. No new zoning violations would be created with the expansions. There will be no further reduction of the open space.Further, the applicant will be permanently dedicating land along the Connecticuit der with a conservation easement. 5. The change does not involve a sign. GeOTMSO 2004 Des L.auriers Municipal Solutions,Inc. i • Massachusetts Department of Environmental Protection DEP File Number: Bureau of Resource Protection - Wetlands WPA Form 7 — Extension Permit for Orders of Conditions 246-551 I Massachusetts Wetlands Protection Act M.G.L. c. 131, §40 Provided by DEP C. Recording Confirmation The applicant shall record this document in accordance with General Condition 8 of the Order of Conditions(see below), complete the form attached to this Extension Permit, have it stamped by the Registry of Deeds, and return it to the Conservation Commission. Note: General Condition 8 of the Order of Conditions requires the applicant, prior to commencement of work,to record the final Order(or in this case, the Extension Permit for the Order of Conditions)in the Registry of Deeds or the Land Court for the district in which the land is located,within the chain of title of the affected property. In the case of recorded land, it shall be noted in the Registry's Granter Index under the name of the owner of the land upon which the proposed work is to be done. In the case of registered land, it shall also be noted on the Land Court Certificate of Title of the owner of the land upon which the proposed work is done. Detach page 3 of Form 7 and submit it to the Conservation Commission prior to the expiration of the Order of Conditions subject to this Extension Permit. To: Conservation Commission Please be advised that the Extension Permit to the Order of Conditions for the project at: Project Location DEP File Number has been recorded at the Registry of Deeds of: County for: Property Owner and has been noted in the chain of title of the affected property in accordance with General Condition 8 of the original Order of Conditions on: Date Book Page If recorded land the instrument number which identifies this transaction is: Instrument Number If registered land, the document number which identifies this transaction is: Document Number Signature of Applicant viWora,7.aoc•rev.311105 Page 3 of 3 ' . Massachusetts Department of Environmental Protection oEp File wvmum Bureau Of Resource Protection - Wetlands ������ ��K��0Q � ~— ������^�� ���00^� ��� ������� r� �������^�^��� ������/ -_ ~~` ^ ~ - ' -- pmwuuuuvosp ��as8@d7usef�VVet|andsF`ro�cti0nAc M.G.L. c. 131. @40 B. Authorization (cont.) This Order of Conditions Extension must be signed bya jorityoftheConservaUonCornnninsion and o copy sent io the applicant and the appropriate D | Off| Notary Acknowledgement Commonwealth ofMassachusetts County of 'to On this of �;otnttiw' —ƒ -------- —Doy Year Before me, the undersigned Notary Public, personally appeared � ___-___---______-____- _______-________' Name of proved to me through satisfactory evidence of identification, which was/were -_-__ ..... ---_-__-_____' Description of evidence of identification to be the person whose name is signed on the preceding or attached document, and acknowledged to mne that he/she signed \t voluntarily for its stated purpose. Conservation Commission Signalur of Not ublig As member of ------- P|acenoterynea| ond/orenya��mpabova --------My rou w��W A�'"~o`ms �� m Massachusetts Department of Environmental Protection Bureau of Resource Protection - Wetlands CEP File Number: WPA Form 7 Extension Permit for Orders of Conditions 246-551 Massachusetts Wetlands Protection Act M.G.L. c, 131, §40 Provided by DEP A--General Information Important* When filling out 1. Applicant: forms on the Robert Bacon computer,use only the tab Name key to move PO Box 2"21 your cursor- ding Address do not use the Northampton MA 01061 return key. &ItyfTown State Zip Code 4:1 2. Property Owner(if different): Name' Mailing Address C own state Zip Code B. Authorization The Order of Conditions(or Extension Permit) issued to the applicant or property owner listed above on: December 14,2004 Date for work at.- ,PjqFerry Road 25; 26 15,16,17,19,53 Street Address _As-s-e-s'-s o_r's-M a pl Piai_Number 71; 1 ParceVLot Number recorded at the Registry of Deeds for.- ........ 2386 155 County Soak Page Certificate of registered land) is hereby extended until: December 14, 2010 67afe ............. This date can be no more than 3 years from the expiration date of the Order of Conditions or the latest extension. Only unexpired Orders of Conditions or Extension may be extended. Date the Order was last extended (if applicable): bate-­_ .............. Issued by; 'Northampton Conservation Commission Gate Versionl.7 Commercial Building Permit May 15,2000 SECTION 10-STRUCTURAL PEER REVIEW(780 CMR 110.11) Independent Structural Engineering Structural Peer Review Required Yes 0 No__T SECTION 11 -OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Robert J Bacon as Owner of the subject property :Ronald Hannah to hereby uth nze?...rn .. __ __ .... ..__ _. ...... act on my gelf, in II tt s relative to work au rized by this building permit application Signatur er Date FRobert J Bacon,Managing Member as Owner/Authorized 1, � m�... �..w.® �.�.� m . . _ m.m a �. .. Agent hereby d re that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed un r t ,,,pains and en fies of perlury I Print Na e Signature of Owner/Age Date SECTION 12-CONSTRUCTION SERVICES 10.1 Licensed Construction Supervisor: Not Applicable ❑ Ronald Hannah CS 096240 Name of License Holder:' ,..... _.... ..__ ........... _..... _........_.. .. ............ License Number 12 John Mason Road Southwick,Ma `04/03/2016 ...�.:.. ........._ . �.. ...... ... ..._._.. _ ... ..._ /(ddrels Expiration Date (413)`454 7840 Signature Telephone SECTION 13 WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.162,§26C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes No Versionl.7 Commercial Building Permit May 15,2000 SECTION 9-PROFESSIONAL DESIGN AND CONSTRUCTION SERVICES-FOR BUILDINGS AND STRUCTURES SUBJECT TO CONSTRUCTION CONTROL PURSUANT TO 780 CMR 116(CONTAINING MORE THAN 35,000 C.F.OF ENCLOSED SPACE) 9.1 Registered Architect: ........ ......... Not Applicable El Name(Registrant) _.., -- ----° Registration Number Address Expiration Date F Signature Telephone 9.2 Registered Professional Engineer(s): ,Thomas E Jenkins JR. Civil ..� ..... . _. Name Area of Responsibility 1350 Main Street Suite 1400 Sprin gfield, Ma 01103 36450 Address Registration Number (413) 726-2100 06/30/2016 Signature Telephone Expiration Date ..e e .. Robert David Oates _....... . .. . ....... _.._......... ,.. ., ......M._.. .M__... ..P...r..e...E. n, .m....__e.e_._r.ed. _B....u..,i ldi.n, g_.. ....._._. ..... . Name Area of Responsibility ,1525 Whipple Ave.,SW Canton, Ohio 44710 28045 Address Registration Number "330_478-3863"! 406/30/2016 Signature Telephone Expiration Date Foundation Richard White Name Area of Responsibility i.50 Railroad Avenue Southington,Ct 06489 146792 _... _ . ....._._... .. ..... _ Address Registration Number :(860) 276 9100 Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number w..,.. �n .,ti,. Signature Telephone Expiration Date 9.3 General Contractor 10ne Development& Construction Not Applicable ❑ Company Name: ;Ronald Hannah : Responsible In Charge of Construction =68 Union Street Westfield,Ma 01085 Address =(413)485-4060z Signature Telephone Versionl.7 Commercial Building Permit May 15,2000 8, NORTHAMPTON ZONING Existing Proposed Required by Zoning This column to be filled in by Building Department LotSize '49416....,._........, m = __... .......... ._...... 690Frontage _.... _, _..._... ..._ _ ."..,. _ ."._ ......__ _ Setbacks Front Side L.' ._ ...... R ..._...j L.320... 8..1720; Rear Building Height :17 Bldg.Square Footage % 7350; e _.. .".: Open Space Footage _..,. R.w,. °° (Lot area minus bldg&paved parking) #of Parking Spaces Fill: volume&Location A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO DON'T KNOW 0 YES IF YES, date issued: 07/02/2004 IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DON'T KNOW 0 YES IF YES: enter Book ; 7944 ) Page= 210&212 and/or Document# ..e.. ..�",......... ri B. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW 0 YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained 0 Obtained , Date Issued: C. Do any signs exist on the property? YES NO IF YES, describe size, type and location: Various locations D. Are there any proposed changes to or additions of signs intended for the property? YES Q NO Q IF YES, describe size, type and location: ; ---------- m,..m. .. ®._ ... �.... �u.��.� E. Will the construction activity disturb(clearing,grading,excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES 0 NO IF YES,then a Northampton Storm Water Management Permit from the DPW is required. Versionl.7 Commercial Building Permit May 15,2000 SECTION 4-CONSTRUCTION SERVICES FOR PROJECTS LESS THAN 35,000 CUBIC FEET OF ENCLOSED SPACE Interior Alterations ❑ Existing Wall Signs ❑ Demolition❑ Repairs❑ Additions ❑ Accessory Building❑✓ Exterior Alteration ❑ Existing Ground Sign❑ New Signs❑ Roofing❑ Change of Use❑ Other❑ Brief Description ;!Construction of 6 Unit storage/hangar Of Proposed Work: SECTION 5-USE GROUP AND CONSTRUCTION TYPE USE GROUP(Check as applicable) CONSTRUCTION TYPE A Assembly A-1 ❑ A-2 ❑ A-3 1B ❑ A-4 El A-5 ❑ B Business ❑ 2A ❑ E Educational ❑ 26 I ❑ F Factory ❑ F-1 ❑ F-2 ❑ 2C ❑ H High Hazard ❑ 3A ❑ Institutional ❑ 1-1 ❑ 1-2 ❑ 1-3 ❑ 3B ❑ M Mercantile ❑ 4 ❑ R Residential ❑ R-1 ❑ R-2 ❑ R-3 ❑ 5A ❑ S Storage ❑ S-1 ❑ S-2 ❑✓ 56 ❑ U Utility ❑ Specify M Mixed Use ❑ Specify I S Special Use ❑ Specify COMPLETE THIS SECTION IF EXISTING BUILDING UNDERGOING RENOVATIONS,ADDITIONS AND/OR CHANGE IN USE Existing Use Group: Proposed Use Group: Existing Hazard Index 780 CMR 34) _.r...._ _ Proposed Hazard Index 780 CMR 34). ........ SECTION 6 BUILDING HEIGHT AND AREA OFFICE USE ONLY BUILDING AREA EXISTING PROPOSED NEW CONSTRUCTION Floor Area per Floor(so _... .. 1 15t 5 7,350; _. � .. , .a ._..., 2nd 2nd �e.� .. ... .. 3rd s 3rd 4th 4th ;._...... .... ...... ._...,. Total Area(sf) Total Proposed New Construction(sf) 7 350; ...... ., .., an....._ , Total Height(ft) 17? Total Height ft .. ......e.a �mu . 7.Water Supply(M.G.L.c.40,§54) 7.1 Flood Zone Information: 7.3 Sewage Disposal System: Public ❑✓ Private ❑ Zone Outside Flood Zone❑ Municipal ❑ On site disposal system E] Versionl.7 Commercial Building Permit May 15,2000 City of Northampton �� � lilt bW Building Department ii 7:CEIVED 212 Main Street Room 100 a: iioftll 411 AUG 3 `? °� Northampton, MA 01060 , > � ph ne 13-587-1240 Fax 413-587-1272 Ab", kilFAN T—,'CONSTRUCT, REPAIR,RENOVATE,CHANGE THE USE OR OCCUPANCY OF,OR DEMOLISH ANY BUILDING OTHER THAN A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION This section to be completed by office 1.1 Property Address: 160 Old Ferry Road Map Lot Unit =Northampton,Ma Zone Overlay District Elm St.District', CIS District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record i_ I Seven Bra v ,LLC Name(Print) Current Mailing Address ... (413) 584-7980 Signature Telephone 2.2 Authorized Acte .... ....... _. ;Robert J Bac n °160 Old Ferry Road Northampton, Ma Name(Print) Current Mailing Address ;(413) 584-7980 Signature Telephone SECTIO 3-ESTIMATED JONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by ermit applicant 1. Building (a)Building Permit Fee $155,000.00 2. Electrical (b)Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee K...._..... ............. ... .......s 4. Mechanical (HVAC) _ ...._..._._. __g 5. Fire Protection 6. Total=0 +2+3+4+5) Check Number '10.3e7 �� `r 7 7,CO This Section For Official Use Only Building Permit Number Date Issued Signature: Building Commissioner/Inspector of Buildings Date File#BP-2016-0283 APPLICANT/CONTACT PERSON ROBERT J BACON ADDRESS/PHONE 20 HAWTHRONE TER FLORENCE (413)485-4104 N l N EC 12.,� n� PROPERTY LOCATION 160 OLD FERRY RD-NORTHAMPTON (_' FLV v MAP 25 PARCEL 015 001 ZONE � THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fer Paid uildin Pe t Filled out vF'ee Paid ? Typeof Construction: CONSTRUCTION OF 6 UNIT STORAGE HANGAR V77 S-F New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included• - Owner/Statement or License 096240 3 sets of Plans/Plot Plan THE FO LOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFO ATION PRESENTED: pprove ditional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR ,Special Permit With Site Plan Major Project: Site Plan AND/ORSpecial Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Demolition Delay Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. File#BP-2016-0283 APPLICANT/CONTACT PERSON ROBERT J BACON ADDRESS/PHONE 20 HAWTHRONE TER FLORENCE01062(413)485-4104 PROPERTY LOCATION 160 OLD FERRY RD-NORTHAMPTON MAP 25 PARCEL 015 001 ZONE THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building-Permit Filled out Fee Paid Typeof Construction: CONSTRUCTION OF 6 UNIT STORAGE HANGAR 7497 SQ FT New Construction Non Structural interior renovations Addition to Existing- Accessory Structure Building-Plans Included: Owner/Statement or License 096240 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFQ#MATION PRESENTED: VApproved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Demolition Delay 9 3a c Signature of Building O facial Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. 160 OLD FERRY RD-NORTHAMPTON BP-2016-0283 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 25 -015 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: Building BUILDING PERMIT Permit# BP-2016-0283 Project# JS-2016-000460 Est.Cost: $155000.00 Fee: $1470.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: ROBERT J BACON 096240 Lot Size(sq. ft.): 43560.00 Owner: SEVEN BRAVO TWO LLC Zoning: Applicant. ROBERT J BACON AT. 160 OLD FERRY RD - NORTHAMPTON Applicant Address: Phone: Insurance: 20 HAWTHRONE TER (411) 485-4104 WC FLORENCEMA01062 ISSUED ON.101512015 0:00:00 TO PERFORM THE FOLLOWING WORK.CONSTRUCTION OF 6 UNIT STORAGE HANGAR 7497 SQ FT POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Si nature: FeeType• Date Paid: Amount: Building 10/5/2015 0:00:00 $1470.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner