Loading...
38B-249 New England Fire&Security, Inc. �I P.O. Box 728 West Springfield, MA 01090 Phone: (413) 734-6500 Fax: (413) 734-6700 EDWARDS SYSTEMS TECHNOLOGY System Contractor's License #1557C DATE: September 5, 2015 QUOTE# 100515-PN1! TO: Thorne's Marketplace FROM: Mike Hennessy SUBJECT: Fire Alarm Additions FIRE ALARM ADDITIONS FOR 3RD FLOOR OFFICE: ITEM (CITY. DESCRIPTION A. 2 Smoke Detector with Base B. 1 Hom/Strobe C. LOT Chapter 9 and Fire Department Documentation D. LOT Programming and Test TOTAL QUOTE...$631.00 NOTE: Cable,box and device installation by Customers electrician. Please note that the price quote does not include sales tax or permit fees if applicable. "in the event the undersigned fails to make payment as hereinafter set forth,and is in default of said payment for a period of 30 days after said payment date,than the undersigned purchaser agrees to pay all costs of collection,including reasonable attorney fee's incurred in any action brought to collect said payment". Thank you for your continued interest in New England Fire&Security products and services. Should you have any questions please feel free to contact me at(413) 734-6500. Thank you, 1 7oiiathaii McGee Mike enn ssy System Sales Representative Accepted By On behalf of Thornes Marketplace LLC MA Systems Contractor License#1557C MA Systems Technician License#378D Connecticut License#0197638-L5 Vermont License#ES-05626 MA Dept.of Public Safety License#SSC0001296 NICET(National Institute in Fire Alarm Engineering Technologies)#77365 New England Fire&Security-a U.L.Listed Fire Alarm Company—UUJS BBB. i CHAPTER 9 NARRATIVE THORNES MARKETPLACE 150 MAIN STREET, NORTHAMPTON, MA Provided by: New England Fire & Security Thornes Marketplace is an existing building and is listed as Use Groups B &A3 per 780 CMR 8th Edition and 2009 I.B.C. The building has 3 levels above grade,a basement and a sub-basement. The building is equipped with sprinklers and an existing automatic fire detection system. The third floor office space is undergoing minor renovation. Existing fire alarm horn/strobes and one pull station will be left in place. One (1) additional horn/strobe and two (2) smoke detectors will be added. Devices shall be U.L. Listed for their intended use. i I 39B Fine seruice enoup Fire Protection Testing&Maintenance Provider P.O. Box 1244 MA License#SC 145974 Belchertown, MA 01007 CT License#FRP 0041132-F1 October 2,2015 Fire Prevention/ Inspector Nichols Northampton Fire Department Re: Family Dollar 505 East Main Street Southbridge,MA Subject: Fire Sprinkler Service: NARRATIVE Inspector Nichols, Fire Service Group is submitting a permit for the following scope of fire sprinkler work to be conducted at Thornes Market 150 Main Street,Northampton.The following required fire sprinkler modifications to be done are result of 41 floor renovation:. 1)Relocate sprinkler branch line around the new skylight. 2)Relocate 7 sprinkler heads to maintain proper sprinkler coverage. Notes: Building is constructed of brick and wood.The fire sprinkler protection is feed with a 4"riser using standard response coverage heads.The above proposed work is to stay within the perimeters of the original system design. All work will be performed by licensed fire sprinkler fitters following the guide lines of NFPA 1.3 and 25 to assure proper coverage is maintained without effecting the original system design. All materials used are to be listed for fire protection. No engineering or drawings required for this scope of work. It is the building owner's responsibility to maintain the fire sprinkler system under the guidelines of NFPA 25. Required routine inspection services are not part of the scope of this project. If you have any questions or concerns,please feel free to contact me at: 413-575-6827 or by email at: tom @fireservicegroup.com Sincerely, Thomas Fournier tom @fireservicegroup.com A 1-888-279-8590•Tel: 413-668-9100 • Fax: 413-213-6567 www.Flr%GI542rulc(25roup.com - NPPAk THOMAS DOUGLAS Architects CONFIRM PROPOSED LOCATION OF SKYLIGHT 196 P6=wg St. MA 01060 413-585-0641 1m 582-9882 REGISTERED ABCHRECI, I P EXIT cos—Has—SoP O YASSACNUSETTS Iw ( �Nn+ru�W 0 P2 w�a �ii�nabu�iu w•� I im•rmNYrw iress r, I ri+mrr mierlm m.r.i riep.sdW ¢o.Hir. 162 SQ s P, tD tp wpro.lnmee ipa•r•ror mwb.UVa PuTOS.•°nM.WNk vm 134 SQ �p•bi 3.ip«Pwn,.�.n. Z ( 3240 LUMENS, FLR ^•�•�,w•«ni-,--m 2680 LUMENS, FLR 140 SQ I • pnSm�pmro PM..Yuu� «ywr eeybpn inopu­d- 6700 . P2 P2 LUMENS, DESK 2800 LUMENS, FLR „„re^'I•i"•m^a°e°�,,,;,„„°m•"°;" 7000 LUMENS DESK se bl.tlon aroMe wbbiydMe I I , IL Pr°pM ror roar space rpulranents. Lo I MERGEN Y \\ // I 107 SQ M P2 P2 P2 I X 2140 LUMENS, FLR I / I s I REPLACE EXISTING MERGEN Y �—— LIGHTS WITH NEW FIXTURES. 201 SQ I I I 4020 LUMENS, FLR I I 104 SQ 10,050 LUMENS, DESK 2080 LUMENS, FLOOR 132 SQ 5200 LUMENS, DESK 2640 LUMENS, FLR 6600 LUMENS, DESK / I I Pt P1 Pt P, t0 I L - - - x I PrgW Mtk Od.�Pn.BHerwvFS i° � tD tD I TxoiuvEs MARKETPLACE - 150 Mv413)5,Nonbunpmn.MA Pb•m(413)584-SSe2 inf•prh•m¢mu4npin¢.¢m LIFE SAFETY NOTES ELECTRICAL LEGEND p1 08N DESIONDE LOPME 2 1-- PER FN EXISTING SPRINKLER SYSTEM TO BE RECONFIGURED AS NECESSARY TO COMPLY WITH CODES. SWITCH(ALL LIGHT SWITCHES TO BE DIMMING) tD POS/TELEPHONE/DATA JACK ALL EXITS DISCHARGES ARE REQUIRED TO HAVE FIRE PULL STATIONS.GENERAL CONTRACTOR Z- TO PROVIDE AND/OR RELOCATE,AS REQUIRED. SWITCH-THREE WAY OUTLET-DUPLEX 3 3. SMOKE DETECTORS ARE REQUIRED AS PER THE LOCAL FIRE DEPARTMENTS REQUIREMENTS.GENERAL CONTRACTOR TO COORDINATE. M SWITCH-MOTION DETECTOR OUTLET-QUAD LIFE SAFETY LEGEND GFI GROUND FAULT INTERRUPTER"`ALL SWITCHES&OUTLETS BY GC ­'By:By: EB cn.rxd er ro sca.:AS NOMD EXIT CEILING MOUNTED,EDGE LIT LED GREEN EXIT SIGN WITH BATTERY BACK-UP. ELECTRICAL NOTES —D..: wens s—rm. PARTIAL THIRD MERGEN Y WALL MTD.EMERGENCY LIGHTING WITH BATTERY PACK BACK-UP. GENERAL CONTRACTOR TO COORDINATE LOCATION OF THERMOSTATS FLOOR 1' WITH HVAC SUBCONTRACTOR. DIRECT QUESTIONS TO DESIGNER. REFLECTED MERGEN Y NEW EMERGENCY LIGHT/EXIT ^ CEILING PLAN SIGN COMBO ELECTRICAL REQUIREMENTS FOR ELECTRICAL/TELEPHONE/SERVER EXIT WITH BATTERY BACK UP SMOKE SMOKE DETECTOR 2. CLOSET TO BE CONFIRMED WITH TENANT. wswlrg Np. PARTIAL THIRD FLOOR PLAN REFLECTED CEILING PLAN 1 i_Oii FIRE EXTINGUISHER ❑S STROBE PULL STATION A-113 ❑HS HORN STROBE ***ALL LIFE SAFETY FIXTURES BY GC NEW KITCHENETTE UPPERAND LOWER CABINETS. NEW I I THOMAS DOUGLAS Architects LAMINATE COUNTERTOP AND DROP-IN SINK. 196 Pleasant St. AREA OF WORK 1857 SID FT INFILL EXISTING TRANSOM WINDOW MA 01060 PANE WHERE IT INTERSECTS NEW 413585-0t 41 PARTITION WALL WITH PLYWOOD. RE sazAa9z COMMOEeED APC OFECT, DETAILS TBD IN FIELD WITH COMMDNWEALTH OF MASSACHUSETTS T-10" I— 1'-0"MIN OWNER'S APPROVAL. I� Ly I ° ❑ 14'-61/4" �, , N U V J .ari..w nFatitiia C) W M LL v //—_ I Dm J"mer M«PHn m.,wrtm«,b SUITE 363 �prc. .Ne.rc� S U I 54 z I w c� ; n � . rc", n..aewe wm"ees n.wNib w. 80 Q F Y. ~ I 0 5`0" I SUITE 364 153 SQ FT I pa� qep".o" r:p.,enbnon.b ne accuracy me `o � ti \� 153 SQ FT uepcperyme.b"nlbb�r //1 a —— 1'-0"MIN I ,.nar�mm�,.ro arc wE,naev a m. Iv J / gepeM br YwO�.wa reyulrcmenb. O 10'-0" 7T 1- PATCH WOOD FLOOR AS 01 106 os NEEDED AFTER ROUGH 1'-0"MIN I r PLUMBING. TO MATCH EXSITING MAPLE. HALL NEW VANITY AND 9'-51/4" �——A COUNTERTOP WITH 0z oa 04 IM INTEGRAL SINK. NEW SUITE 35 °/ DOUBLE CABINETABOVE I 11'-3 1/4" 10'-11 5/8" 9'-5n 12'-0" 14'-4 3/4" I 149 SQ FT SUITE Y 352 r' N �— I SUITE 358 N SUITE 360 SUITE 361 SUITE 362 co 65 SQ FT _ i \ / i 156 SQ FT 123 SQ FT 155 SQ FT 228 SQ FT I L e� I /X\ I I PmieclTn SUITE S U IT—El 57 Aee� OReneve°S- 350 174 SQ FT I MARKETPLACE ✓s I MARKETPLACE 60 SQ FT SUITE 50M 143)5 N"n1"mproo.MA P6o"=(413)584-5582 353 84 SQ FT ALIGN NEW WALL TO EXISTING \\—WINDOW 1s PESMIN�EVEIDPMEN G E N E RA L N O T E S: 2 p1 ERST 1 . PATCH AND REPAIR ALL GWB AS NEEDED AFTER 0 PENETRATIONS BY OTHERS. 2. ALL CASEWORK AND BASEBOARDS TO MATCH EXISTING. 518 GWB p.gatl i0: 1zoz1 112"HOMOSOTE 2X4 WD STUDS,24'0.C. D.aw"Sy: ES STAGGERED ON 2X6 PLATE cneaee ey TO Scale:AS NDTED T. bmn Die: 9I"/15 1 PARTIAL THIRD FLOOR PLAN PARTIAL THIRD 3/16" — 1'-O" FLOOR PLAN Drewiig NO 518GWB A-103 FIBERGLASS SOUND BATT 1/2"HOMOSOTE INSULATION PARTITIONAL WALL DETAIL 2 1 1/2" _ 1 _O City of Northampton Building DeparkMnt THOMAS DOUGLAS ArchHects Plan Review 196 PInnIIt SL 212 Main Street • MA 01060 Northampton, MA 01060 413365.0641 fart 582-9882 REGISTER-HITECT, COMMONWEALTH OF MASSACHUSETTS T Mlraenw luYly YaY 4aa pM�aal�rwa npYWY r'+R•v�YTY,�aW REMOVE DESK AND COUNTERTOP. SALVAGE BOTH FOR OWNER. REMOVE EXISTING WAINSCOTTING DMdeimer.Fbor Pbn m rcmenb REMOVE MISC WALL FIXTURES IN AND MOULDING FROM CORRIDOR. Il�nbahve puryvaea vny.WMb we ao mt nouM tlro neon pans a«ur.cy, RECEPTION. PATCH WALL AS PATCH AND SKIM AS NEEDED. �'—.-&"" """ �mrcaw,Mtlpn.aamtlM .a° pbYnna a the noon q..voa or par ativbarc NvuM cmEUCt a NEEDED. ardul.Yeepeenea m�tltletiee ene popeHy m eabmtlne m roar aaW/actlal as m the suneYlny of Me — prcperty M par space repulrcmenb. , LV O O ______________________,_,__,___---_fA V SUITE 356 - -------------------------- S U I 54 Y 71 SQ FT p • " : = '° AREA OF CONSTRUCTION z 80 Q F U REMOVE EXISTING HELVING I �x� I 1� � I P"-Tb SUITE 355 Aa°al Rena��,onam THORNES SUITE 148 SQ FT y :DEMO EXISTING PARTITION WALL MARKETPLACE OMuvL .Noah e,p•oe,MA 352 SUITE 358 M.4tJ155455ei 65 SQ FT i \� �� i 154 SQ FT x SUITE I SUI E`357 350 5 74 SQ FT R'.09N'ba15 DESIGN DEVEIOPMEM Oro5115 PER-ET 60 SQ FT SUITE — — — — — — 353 84 SQ FT Proje°ID: 12021 Drain By EB OM1a1wE BY TD Scale:AS NOTED 814115 Shce1TT.Ab: PARTIAL THIRD FLOOR EXISTING AND DEMO PLAN DravirrM No. PARTIAL THIRD FLOOR EXISTING AND DEMO LA �/ 0-3/1 6" = 1'-0" E"' 103