43-033 (4) FOR CONSTRUCTION R GS Rail&Anchor Assembly 5PPp5 G , ,t/'� • UniRac Top-Clamp 32 Taugwonk Spur,Al2 UniRac SolarMount Rail Stonginton,CT 06378 M \ �6, / UniRac Standard L-Foot Phone(860)535-3370 Meta • S-5! U Clamps Fax(413)683-2225 f 'l Seam J Sta�d��9 2�, 0 G Module --..,1� /, Standing Seams Spaced @ 16"O.C. GRID-TIED /oo61Nss Rooftop !" PHOTOVOLTAIC SYSTEM 0 C 3.060kW DC @ STC Sheathing _ loss GREY, CAROLYN-ADD-ON 1o", 483 PARK HILL RD Z`X FLORENCE, MA 01062 Project# 10319768 DESIGNER: EG 1, 1 Attachment Profile A Attachment Detail REVIEWER: Ash Bowersock Scale: 1" — I- " VERSIONDA-E 2015-08-18 - 1 0 REVISIONS 20"Max Roof Framing PV Module Rail Overhang # BY Date Notes 1 II tl II Landscape: --4.9 in. Roof Anchor s Portrait: -12.2 in. & Flashing � < I I; i 11 1 11 Landscape: 29.3 in. a Anchors located � Portrait: -40.7 in. on alternate roof I 1 1 II . ar, framing members --- 1.37 in. 39.1 in. 32"Max -- - -- - SlMt Rail -i. --- - Anchor Spacin oaroun a wit r Sta ered Attachment Detail MHolesg A Not to Scale I T � Trina Solar TSM-255PA05.08 j 65.0 in. 20" Max -A, Rail Splice Rail Overhang I� WEEBLug SS W asher Ground Wire &Nut -�-� B �-r— -y I B �-+— ® Unirac Rail �I SS Bolt to J Distance from Module Corner Minimum Maximum Stagger splice locations Min of 2 supports Long Side,A 8.1 in. 16.2 in. within the each row of modules on either side of splice Short Side', B 2.0 in. 7.8 in. SS Fiat SS VARIES Washer SS Bolt with a max spacing of 60" 'Top-Clamps may be used on the Short DETAILS Sides of the Module 4 Rail S lice Detail 5 UL Approved Mounting Locations 6 Grounding Lug & Rail Not to Scale Not to Scale Ncat to Scale PV-A03 FOR CONSTRUCTION 32 Taugwonk Spur,Ali: Stonginton,CT 06378 Phone(860)535-3370 32'-10" — -- "" — Fax(413)683-2225 6" 19'_�" -- 13'-1" GRID-TIED 10 i ` PHOTOVOLTAIC SYSTEM 3.060kW DC a@ STC - GREY, CAROLYN-ADD-ON 483 PARK HILL RD (N)PV Array : FLORENCE, MA 01062 12 Trina Solar Project#10319768 ; TSM-255PA05.08 Modules „�. ... �......:... _ �, .�,.... }.,, DESIGNER: EG REVIEWER Ash Bowersock I VERSION DA-E. 2015-08-18 f REVISIONS 19'-10" # By Date Notes 3 (N)SolarMount Rails a 5 m i i o -----'J- --- — 1.- --- -=I o o N 2'-5" i U c PV Array 1 0 0 0 Scale: 3/16" = P-0" m v m L2 Z UniRac SolarMount Mounting Notes: • Integrated Full System Grounding and Bonding to UL 2703 • Total Quantity of Attachments=36 PV ARRAY 1 -MECHANICAL LOADS Equipment Specifications: • Roof Zones are defined by dimension,a=3.0 ft. Array Area: 212.7 ft' Total Photovoltaic Dead Load: 3.05 psf Module: (12) Trina Solar TSM-255PA05.08 • Maximum Allowable Cantilever for UniRac Rail is Y3 the Maximum Rail Span Array Weight: 648.4 Ibs Avg.Dead Load per Anchor: 18.0 Ibs Inverter 1: (12) Enphase Energy M215-60-2LL-S22-IG • Racking and Attachment: UniRac SolarMount with S-51 U Clamps attached with--- Anchor Qty.: 36 Racking: UniRac SolarMount • All Dimensions shown are to module edges, including 1/4 in. Spacing between Attachment Flashing: S-5! U Clamps Modules required when using the Top Clamp Method. Design Values by Roof Zone: Corner Egde Interior 3/16"= V-0" • The SolarMount Rails will extend 1-112 in. beyond the Module Edge in order to Max. UniRac Rail Span: 60 in.O.C. 60 in.O.C. 60 in.O.C. Roof Specifications: =ate support the End Clamps. Max. UniRac Rail Cantilever: 20 in.O.C. 20 in. O.C. 20 in.O.C. Roof 1: • UniRac requires one thermal expansion gap(4 in.) for continuous sections of rail """O. .*3'"""""""""" Standing eam Metal N MODULE LAYOUT Adjusted Anchor Span: 32 in.O.C. 32 in. O.C. 32 in.O.C. g greater than 40'in length .-.................... I.•••••••••••••••••• ......•••.......•••• (Single Layer) Downforce Point Load: 230.3 Ibs 230.3 Ibs 230.3 Ibs • Array Installed according to the UniRac SolarMount Design& Engineering Guide •.............•••••.....• •••......••............••••••• 2"x 4"Wood Truss E PUB14NOV03 Uplift Point Load: -133.9 Ibs -133.9lbs -109.6 Ibs @ 24"O.C. W /� • Attachment Locations, If shown,are approximate. Final adjustment of attachment Minimum Anchor Strength: See Roof Manf.Anchor Specifications Pitch: 29° ( Azimuth: 190° PV—A02 location may be necessary depending on field conditions.All attachments are Average Safety Factor: See Roof Manf.Anchor Specifications Array Size: 12 Modules staggered amongst the framing members. S FOR CONSTRUCTION ------------- ------------------------ 1' .,.� • -�'"' ! (Existing) PV Array : ! ...- �••y- 36 Canadian Solar Modules I IR 36 Enphase Energy 215-60-2LL-S22 Micro-Inverters ; DP&W Top of Pole Mount ! Pitch:35° ! ! AZlmuth:180° i 32 Taugwonk Spur,Al2 I ! Stonginton,CT 06378 ' (E) Property Line Phone(860)535-3370 ' Fax(413)683-2225 I (E) PVC Trench-18" Below Grade GRID-TIED ! PHOTOVOLTAIC SYSTEM ' ' ! Equipment Located on Pedestal Mount: 3.060kW DC STC ' (E) Utility Meter GREY, CAROLYN-ADD-ON (E) Main Service Disconnect 483 PARK HILL RD ' ! (E)AC 60A Fused Disconnect i FLORENCE, MA 01062 (E) PV Production Meter- Enphase RGM Project#10319768 1 (E) PV Production Monitor-Enphase Envoy DESIGNER: EG ' Existing Ground , ! (E) PV AC Combiner Sub-Panel-F.O.I.via(N)15A Breaker ! Mounted Solar Arrays REwEwER: Ash Bowersock 4 _ E 2015-08-18 VERSION DA' REVISIONS ' (N) 1" PVC in-65'Trench- ! # By Date Notes '1 I Minimum 18" Below Grade , • ' ! � : ' z ' I If /' I 3 1 ' _ (E)Accessory Building � e T (E) Single Family Dwelling a ; '� 'T 483 R ARK HILL RD ` I 11 . (N) PV Array (E) Driveway ! ;-$ 12 Trina Solar TSM-255PA05.08 Modules 12 Enphase Energy M215_60-2LL.-S22-IG Micro-Inverters UniRac SolarMount with S-5 U Clamps Standing Seam Metal Roof 2"X 4"Wood Truss Q 24"O.C. Pitch:29° - Azimuth:190° ! JIN ! ! ! ! I f 1 J j I T L� • (E) Single Family Dwelling I a ` ! 1 SITE PLAN ! ! 1 ! ! VARIES Scale: 1" = 300' !------------------------------------------------------------------ ' -----------------------------------------------------------------N-------i SITE PLAN Z BUILDING DETAIL AIL Scale: 1" =40' w 7r E PV-A01 S i_ FOR CONSTRUCTION <_a C Grid-Tied Photovoltaic System City of Northampton - -�, Building Department DC Rating: 3.060 kW Plan Review RGS Grey, Carolyn- 212 Main Street Y Y Northampton, MA 01060 32 Taugwonk Spur,Al2 483 Park Hill Rd Stonginton,CT 06378 Florence, MA 01062 �� �� Phone( 13) 535-3370 2225 Fax(413)683-2225 Jurisdiction: City of Northampton GRID-TIED PHOTOVOLTAIC SYSTEM 3.060kW DC @ STC GREY, CAROLYN-ADD-ON Scope of Work: General Notes: Sheet List 483 PARK HILL RD RGS Energy shall install a 3.060 kW Grid-tied Photovoltaic("PV) System 1. System follows any/all Fire Code Setbacks per Ordinances of the City FLORENCE, MA 01062 totaling (12)Trina Solar TSM-255PA05.08 Modules with(12) Enphase Energy Of Northampton. Sheet No. Sheet Title Project#10319768 M215-60-2LL-S22-IG Micro- Inverter(s).The Modules shall be flush mounted 2. All projects will comply with the Ordinances of the City of PV-000 COVER DESIGNER: EG on the standing seam metal roof and interconnected via load side breaker Northampton. connection in the existing PV AC Combiner Panel located at the existing power 3. Construction Hours: 7am-8pm Monday-Friday,9am-8pm Saturday, PV-A01 SITE PLAN REVIEWER: Ash Bowersock pedestal. No time on Sunday,or legal Holidays. PV-A02 MODULE LAYOUT VERSIONDA-E. 2015-08-18 4. Product Data Sheets shall be included. Equipment Specifications: 5. Rooftop penetrations shall be completed and sealed per code by a PV-A03 DETAILS REVISIONS Module: (12) Trina Solar TSM-255PA05.08 licensed contractor. # By Date Notes Inverter 1: (12) Enphase Energy M215-60-2LL-S22-IG 6. All Photovoltaic modules shall be tested and listed by a recognized PV-A04 MATERIALS ' Racking: UniRac SolarMount. laboratory. PV-E01 ELECTRICAL DIAGRAM Attachment Flashing: S-51 U Clamps 7. Certifications shall include UL1703, IEC61646, IEC61730. 2 8. A continuous ground shall be provided for the Array and for all PV-E02 SYSTEM CALCS 3 Photovoltaic Equipment. PV-G01 SIGNAGE < 9. DC Wiring shall be run in metal conduit or raceways within enclosed Roof Specifications: spaces in a building. 10. Conduit,Wire systems and Raceways shall be located as close as Roof 1: possible to ridges, hips, and outside walls. Standing Seam Metal 11. Conduit between Sub Arrays and to DC Combiners/Disconnects shall (Single Layer) use guidelines that minimize the total amount of conduit by taking the 2"x 4"Wood Truss shortest path. @ 24"O.C. 12. Space Requirements for electrical equipment shall comply with NEC Pitch:29" i Azimuth: 190° Article 110. Array Size: 12 Modules 13. Equipment grounding shall be sized in accordance with Table 250.122. X 14. Connectors that are not readily accessible and that are used in the Site Specifications: circuits operating at or over 30V AC or DC shall require a tool for Occupancy: II opening and are required to be marked "Do not disconnect under Design Wind Speed: 90 MPH load"or"Not for current interrupting", per 690.33 (c)&(e). Exposure Category: C 15. All signage to be placed in accordance with local building code. Mean Roof Height: 25 ft 16. Signs or Directories shall be attached to the electrical equipment or a Ground Snow Load:40 PSF located adjacent to the identified equipment. Adj. Roof Snow Load: 21.0 PSF 17. Signs should be of sufficient durability to withstand the environment. 18. Any plaques shall be metal or plastic with engraved or machine printed letters, or electro-plating, in a red background with white All Work to be in Compliance With: lettering,a minimum of 3/8"height and all capital letters. 2014 National Electrical Code (NEC) a 2009 International Residential Code(IRC) f'" F 2009 International Building Code(IBC) "' • 2012 International Fire Code(IFC) a Not to Scale 2012 Uniform Mechanical Code (UMC) -- 2012 Uniform Plumbing Code(UPC) ti ^a �'� COVER MA 780 CMR, 8th Edition -including 214111 revisions to Tables R301.2(4) &R301.2(5) - ASCE/ANSI 7-05 Minimum Design Loads for Buildings and Other Structures As amended and adopted by City of Northampton PV-000 TM Ilnpre—Aenterl_ Inr�nvafion �".VVVYY YvM V"VI.V.a - Unmatched Quality Unbelievable Price v�aMiii C-55_11 Mimi � ii ii M8 hole centered 3/8" or M10 hole on part 2" located 112" (13mm) °o (51 mm) from edge of part 1.18" (30mm 1.5 38mm) .9" 23m ,; " 138mm 23rnm Note:Install both 1 ! setscrews on same side of damp. -- (19mm) 10rt M) Actual Size (31Rmm) Actual Size (38mm) The S-5-U and S-5-U Mini clamps are each furnished with the hardware shown above. Each box also includes a bit tip for tightening setscrews using an electric screw gun. A structural aluminum attachment clamp, the S-5-U is compatible with most common metal roofing materials excluding copper. All included hardware is stainless steel. Please visit www.S-5.com for more information including CAD details, metallurgical compatibilities and specifications. ~ 1 N w For horizontal seams under a ` a.65° fi5"do not use this clamp. Visit www.S-5.com for more detailed information and proper clamp x to use. w 'ZZ The S-5-U clamp has been tested for load-to-failure results on most major brands I died Prot I of siantiiiig seam rutliing, iiie iiidepencieui iab Les[ tlaia iutitici at www.S-5.eom can be used for load-critical designs and applications. S-5!TM holding strength is unmatched in the industry. Wall) 111cilerifIl bLll 1-101 l.)iCJ'CC 1-00f Warranties inlact. 5-5!'"Warning!Please use this product responsibly! Products are protected by multiple U.S. and foreign patents. Visit the website at Distributed by www.S-S.com for complete information on patents and trademarks.For maximum holding strength,setscrews should be tensioned and re-tensioned as the seam material compresses. Clamp setscrew tension should be verified using a calibrated torque wrench between 160 and 180 inch pounds when used on 22ga steel and between 130 and 150 Inch pounds for all other metals and thinner gauges of steel. Consult the S-SP"website at www.S-S.com for published data regarding holding strength. Copyright 2008,Metal Roof Innovations,Ltd.S-5!—products are patented by Metal Roof Innovations,Ltd. version 080808 r The S-S-U Clamp The S-S-U clamp is by far our most '111"Inks to our p'-11C.11le(I popular and most versatile clamp. round-pofill Setscrews, It will fit about 95% of the standing seam profiles manufactured in North America—including most structural and architectural profiles. It can be used on vertically oriented seams and 1)anefing' thereby by rotating the clamp 90 degrees it can also be used on most horizontal 2" seam profiles. is simple design, generous tightness iviuranfies. Idimensioning and multiple hole orientations are what make it so versatile for use with S-S!TM snow retention products and other heavy-duty applications. Installation is as simple as placing the clamp on the seam and tightening the patented round-point setscrews to the specified tension. Then, affix ancillary items using the bolt provided. Go to www.S-S.com/tools for information and tools available for properly attaching and tensioning S-S!TM clamps. 1 He J-�-U 1�i11i1 The S-5-U Mini is a medium-duty, non-penetrating seam clamp. (A bit shorter than the S-S-U and having one setscrew rather than two.) The Mini is the choice for attaching all kinds of rooftop accessories: signs, walkways, satellite dishes, antennas, rooftop lighting, lightning protection systems, solar arrays, exhaust stack bracing, conduit, condensate lines, mechanical equipment—just about anything!* *S-5!TM Mini clamps can be used with RamGard®unitized snow guards,but are not compatible and should not be used with S-5!TM SnoRailTK/SnoFenceTm or ColorGard® snow retention systems. 888-825-3432 www.5- S .COrn " UNIRAC SOLARMouNT Technical Datasheets-.1 SolarMount Beams 3102N 3102080-13, 3102400, 310240C-13, 310240D, 410'144,,Ivl; 4,10168M, 410204M, 410240M Properties, Unify SolarMount SolarMount HID Beam Height in 2.5 3.0 Approximate Weight(per linear ft) Plf 0.811 1.271 Total Cross Sectional Area in 2 0.676 1.059 Section Modulus fX-Axis) w 0353 Section Modulus(Y-Axis) in 3 0.113 0.221 Moment of Inertia(X-Axis) in 4 0.464 1.450 Moment of Inertia(Y-Axis) in 4 0.044 0.267 Radius of Gyration(X-Axis) in 0.299 1-.170 Radius of Gyration (Y-Axis) in 0.254 0.502 SLOT FOR T-BOLT OR SLOT FOR T-BOLT OR 1.728--� !/4-HEX HEAD'SCREW Y4"HEX HEAD SCREW 2X SLOT FOR I— SLOT FOR BOTTOM CLIP 2,500 BOTTOM CUP F T T 3,000 1.316 SLOT FOR 3/8" HEX BOLT SLOT FOR 1.385 1 — 3/8" HEX BOLT .387 .750-- I+-�-- 1.207�1.875 A A ►x I.x qn !ark.Aourt Bearn Qnk,.AA I,nt WD Bearn Dimensions specified in inches unless noted i 08UNIRAC was SOLARMouNT Technical Datasheets ,," No SolarMount Beam Connection Hardware o �IrMi o ant - oo Fart Wo. 304000C, 304000D • L-Foot material: One of the following extruded aluminum alloys: 6005- _ T5,6105-T5,6061-T6 • Ultimate tensile: 38ksi,Yield:35 ksi • Finish: Clear or Dark Anodized • L-Foot weight:varies based on height: -0.215 Ibs(98g) Allowable and design loads are valid when components are Bea ' assembled with SolarMount series beams according to authorized Bolt UNIRAC documents L-Foot For the beam to L-Foot connection: •Assemble with one ASTM F593%7-16 hex head screw and one errated ASTM F594 Wserrated flange nut Flange Nu /f • Use anti-seize and tighten to 30 ft-Ibs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third-party test Y results from an IAS accredited laboratory NOTE: Loads are given for the L-Foot to beam connection only; be " X sure to check load limits for standoff,lag screw,or other attachment method Applied Load Average Safety Design Resistance Direction Ultimate Allowable Load Factor, Load Factor, 1L_ •., �y_ sit �i• 1� yhl. _ � s(itil pus(Irl r� ius%iN) �+ Sliding,Zt 1766(7856) 755(3356) 2.34 1141 (5077) 0.646 Tension,Y+ 1859(8269) 707(3144) 2.63 1069(4755) 0.575 Dimensions specified in inches unless noted Compression,Y-. .3258(14492) 1325(5.893) 2.46 2004(891.3) 0.615 Traverse,Xi 1 486(2162) 213(949) 2.28 323(143G) , 0.664 ~ ` �n �� � RAC K 8U�� & �� �� x � n So|arMoW8tMid Clamp p��I:it wa�302101C,302101D.302103o.302 nvD. ono^onm.ou��ono ^ Mid clamp material: One of the following extruded aluminum Bolt aUoyo:SO85-T5.G105'T5.68G1'TG rra — ' �' ^ Ultimate tensile: 38kai.Yield:Clamp— ^ Finish: Clear cv Dark Anodized ^ Mid clamp weight: U.O5U|bo(230) ^ Allowable and design loads are valid when components are assembled according to authorized UN|RACdocuments ^ Values represent the allowable and design load capacity of single '^ mid clamp assembly when used with oGn|orN1ount series beam Uo retain a module in the direction indicated Assemble mid clamp with one Uninao}4'-20l-bo|t and one l4'-2O _ ASTyNF5D4 serrated flange nut Use anti-seize and tighten bo1Oft-|bnoftorque Boa''' � ^ Resistance factors and safety factors are determined according to ` pod 1 section S of the 2005 Aluminum Design YNonuu|and thind' partyteutreou|tafromon |AS000redibed|abombum Applied Load Average Allowable Safety Design Resistance .�:m,~°'� ~ - ,,"�m".~ Direction Ultimate Load Factor, Load Factor, Tension,Y+ 2020(8987) 891 (3963) 2.27 1348(5994) 0.667 Transverse.Z+ 520(2313) 229(1017) 2.27 346(1539) n,665 A Sliding, X± 1 1194(5312) 490(2179) 2.44 1 741 (3295) 0,6201 W Dimensions specified io inches unless noted S(.-)arMoWnt End Clamp Pm�wu�xo2nV n'xncoozc'auuwco.uozuuoo, 301".)030.302004o.302004o.302005u.302005o, 30,?o06c'302006o.302007o.302008C.3020080. 3o,!109o.302009o.302010c.302011o.302012C , End clamp material: One of the following extruded aluminum alloys:8OU5-T5.G1O5'T5.GUS1-TS Olt ~ Ultimate tensile:38kni.Yield: 35kui " Finish:Clear or Dark Anodized End clamp weight:varies boned on height-0.058|hn(26g) - End Clamp ^ AJ|owab|oand design loads are valid when components are �oaa��b|adac�ondi��t�au�hohzad ��|FD\Cdooumonts Flange Nut Values represent the allowable and design load capacity ofosingle end clamp assembly when used with aSo|odNnunt series beam to retain module in the direction indicated ^ Assemble with one Unineuk4"'2OT-bob and one 1/4"'2UAGTyWF504 serrated flange nut ' """" ^ Use anti-seize and tighten to 10 ft-|bo of torque ^ Resistance focto,nand aah:tymoionsonedot�nninud occonjing to ' part 1 section Qof the 2005 Aluminum Design Manual and third ' Y pmrty test results from an |AS accredited laboratory A ����N�� ~ N1odu�omuotbein�oUedot|eoo!15in�ume\therendofobmom `r ' ON.x Applied Load Average Allowable Safety Design Resistance Direction Ultimate Load Factor, Loads Factor, Tension,Y+ 1321 (5876) 529(2352) 2.50 800(3557) 0.605 ` - =^ Dimensions specified m inches unless noted 08UNIRAC SolarMount Technical Datasheet Pub 110818-ltd V1.0 August 2011 SolarMount Module Connection Hardware.................................................................. 1 BottomUp Module Clip.................................................................................................1 MidClamp ....................................................................................................................2 ErvdClamp------------------------------------ ....... ...................___....... .....................-------2 SolarMount Beam Connection Hardware......................................................................3 L-Foot...........................................................................................................................3 SolarMountBeams..........................................................................................................4 Solar-Mount Module Connection Hardware SolarMount Bottom Up Module Clip lei-t No. 302000C Washer Bottom Up Clip material: One of the following extruded aluminum Bottom Nut (hidden..see alloys:6005-T5,6105-T5,6061-T6 Up Clip note') Ultimate tensile: 38ksi,Yield:35 ksi e I - iii , ,.i VIVI VV.LVV Bottom Up Clip weight: —0.031 Ibs(14g) Beam 4 Bolt Allowable and design loads are valid when components are assembled with SolarMount series beams according to authorized UNIRAC documents Assemble with one%"-20 ASTM F593 bolt, one%"-20 ASTM F594 r" serrated flange nut, and one%"flat washer • i;se ar:ii-sere cnu iic3iitcn u U ii-iba ui uryue Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third- ' - __ party test results from an IAS accredited laboratory Module edge must be fully supported by the beam * NOTE ON WASHER: Install washer on bolt head side of assembly. DO NOT install washer under serrated flange nut Applied Load Average Allowable Safety Design Resistance Direction Ultimate Load Factor, Load Factor, Ibs(N) Ibs(N) FS Ibs(N) 0 Tension,Y+ 1566(6967) 686(3052) 2.28 1038(4615) 0.662 Y Transverse, X± 1 1128(5019) 329(1463) _ 3.43 . 497(2213) 0.441 rX Sliding, Z± 66(292) 27(119) 1 2.44 41 (181) 1 0.619 Dimensions specified in inches unless noted a THE Universal MODULE TSM-PA05.08 DIMENSIONS OF PV MODULE ELECTRICAL DATA(STC) unit:mm 941 Peak Power Watts-Pv-(Wp) 245 250 255 260 J Power Output Tolerance-Pm 1%) 0-+3 SHE Maximum Power Voltage-VmPP(V) 29.9 30.3 30.5 30.6 Box Maximum Power Current-IMPP(A) 8.20 8.27 8.37 8.50 NAn+EPwTE "- o Open Circuit Voltage-Vca(V) 37.8 38.0 38.1 38.2 .99x12 INAWNG HOLE Short Circuit Current-Isc(A) 8.75 8.79 8.88 9.00 Module Efficiency qn,f%) 15.0 15.3 15.6 15.9 i STC:Irradiance 1000 W!m`,Cell Temperature 25°C,Air Mass,AMt.S according to EN 60904-8. Typical efficiency reduction of 4.5%at 200 WW according to EN 60904-1. lo � � C ELECTRICAL DATA(NOCT) Maximum Power-P~(Wp) 182 186 190 193 Maximum Power Voltage-VM (V) 27.6 28.0 28.1 28.3 Maximum Power Current-Inn PP(A) 6.59 6.65 6.74 6.84 s-ate UNDNlG HOIE A A Open Circuit Voltage-Voc(V) 35.1 35.2 35.3 35.4 ­_Hour Short Circuit Current-I.,(A) 7.07 7,10 7.17 7.27 NOCT:Irradiance at 800 W/m`,Ambient Temperature 2WC,Wind Speed 1 m(s. 812 811 MECHANICAL DATA Back View Solar cells Multicrystalline 156 x 156 mm(6 inches) Cell orientation 60 cells(6 x 10) Module dimensions 1650.992 x 35 mm(64.95x39.05x1.37 inches) Wei3S rn 1 @. (41,0Ib5) � 1±IC1i5 3.2 rt)m{0:13 1nehe3i.HigFi Transmissiesn.AR Coated Tempered Glass /00/1000 mm 8ackshoet White Frame Black Anodized Aluminium Alloy A-A J-box IP 65 or IP 67 rated Cables Photovoltaic Technology cable 4.0 mm'(0.006 inches"), 700/1000 mm I-V CURVES OF PV MODULE(245W) Connector MC4 or MC4 Compatible lo.» 9•'° tOWW/m` TEMPERATURE RATINGS WARRANTY 8." 2 800w/m° Nominal Operating Cell 10 year Product 7.x 44°C(-+ °C) Temperature(NOCT) Workmanship Warranty 60 /m m 0W Temperature Coefficient of Pm -0.41%/°C 25 year Linear Power Warranty U 4,". 400W/m' Temperature Coefficient of Vx -0.32%/'C (Please refer to productworranty for de tails) g.c now/-, Temperature Coefficient of kc 0.05%/°C I,r, 0.- To,- 20.1° X).T 40.- Vdtage(V) MAXIMUM RATINGS Operational Temperature -40-+85°C Maximum System 600V DC(UL) Voltage Max Series Fuse Rating 15A a v (wFRT1FICATION o N C �L UE IR' PAC.KAGiNG CON FiGURATION USTEO r�•" Modules per box:30 pieces w Modules per 40'container.840 pieces EU-28 NlEEE CON.PN,Var CAUTION!READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT, Irin-asolaC 02014 Trina Solar Limited.All rights reserved.Specifications included in this datasheet are subject to change without notice. Smart Energy Together Mono Multi Solutions THE Ur-%liversal MODULE 60 CELL MULTICRYSTALLINE MODULE 245-26OW PA05.08 POWER OUTPUT RANGE Our most versitile product 15.9% Cory)pcitible wjt�- --ill major BO-S components and system MAXIMUM EFFICIENCY designs 0 +3 t7'0'01 One of the industry's most trusted modules POWER OUTPUT GUARANTEE Field proven pei fc,rrInnnce Highly reliable due to stringent quality control nperctiSri vvilt; ol.jr p::1rt 1e s Over 30 in-hous tesfs (UV,TIC, HF and many more) r;!ic a I Ii o s s s. V,;i h!,,:,)ca In-house fesfing goes well beyond certification fecluiren-tents senca or,,,jrrd 1 i-te glo�,e,71 nn,:� PIG resistant -i ec,h r-ykt-t ch customer r 9,r.D aI;:�, ng, Certified to withstand challenging environmental , cre cornn.,itte(j conditions �-,,Jldinq strofelgi,--, rriuh-)a H, 22400 Fa wind lorld 5400 PC snow lc)I�d devescpes,r,.isir+lt, .tors ?d :Ifher partners��--is The of sf I.,,recj s, att f nergv LINEAR PERFORMANCE WARRANTY 10 Year Product Warranty• 25 Year Linear Power Warranty Trina Solar Limited V00% a ddition', WUe 909e nc,so/or" franly Irin-asolar 80% NUNN"_ Smart Energy Fugether Years 5 10 15 20 25 RGS Property Owner Consent Form Owner: Address: t I Town: State: MA Zip: C 1/ Z Phone: I hereby give permission to RGS Energy and their representatives to pull the required permits for a solar installation on my property. Property Owner Date August 18, 2015 To: Code Enforcement Division From: James A. Marx, Jr. F.E. Re: Engineer Statement for Grey Residence, 483 Park Hill Rd., Florence, MA - Solar Roof Mount Installation I have verified the adequacy and structural integrity of the existing Main Roof I(standing seam): 2" r x 4"wood truss 24" c-c with roof slope distance 19'-10";pitch 29 deg.; for mounting of solar panels and their installation will satisfy the structural roof framing design-loading requirements of the Massachusetts building code—780 CMR Residential Code 8th Ed. For the installation of the solar mounting.the Unirac Solarmount rails with securely fastened with S-5! U-Clamp at 32" or every other seam. The mounting system has been designed for wind speed criteria of 90 mph Exp. C and ground snow criteria of 40 psf. Wind loads will exceed seismic loads. Other climate and geo design criteria are not applicable to this solar installation. The design will meet or exceed load requirements from the MA 780 Residential Code. The roof structure is adequate to support self-weight of roof, PV panels (weight distribution < 2.7 psf) and wind or snow loading conditions. The solar system and the mounting assemblies will comply with the applicable sections of the MA 780 Code and loading requirements of roof-mounted collectors. Thereby, I endorse the solar panel installation and certify-this design to be structurally adequate. N!I Sincerelv. Y Jaynes A. Marx, Jr. Professional Engineer MA '36365 10 High Mountain Road Ringwood,NJ 07456 cc: RGS Energy The Commonwealth of Massachusetts Department of Industrial Accidents t>jjtce of Investigations 600 Washington Street Boston,MA 02111 www.mass gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Lembly Name(Business/Organization/Individual): Alteris Renewables Inc. dba RGS Energy Address: 106 Route 32, Suite 10 City/State/Zip: North Franklin, CT 06254 Phone#: (860) 535-3370 Are you an employer?Check the appropriate box: Type.of project(required)- 1. x❑ I am a employer with 320 4. ❑ I am a general contractor and I 6. ❑New construction employees(full and/or part-time).* have hired the sub-contractors 2.❑ I am a sole proprietor or partner- listed on the attached sheet. # 7. ❑Remodeling ship and have no employees These sub-contractors have 8. ❑Demolition working for me in any capacity. workers' comp. insurance. 9. ❑Building addition [No workers'comp. insurance 5. ❑ We are a corporation and its required.] officers have exercised their 10: Electrical repairs or additions 3.❑ I am a homeowner doing all work right of exemption per MGL 11.❑Plumbing repairs or additions myself. [No workers' comp. c. 152, §1(4),and we have no 12.❑Roof repairs insurance required.] t employees. [No workers' 13.❑X Other solar panels comp. insurance required.] *Any applicant that checks box#1 must also till out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidasit indicating such. zContractors that check this box must attached an additional sheet showing the name of the sub-contractors and their workers'comp.policy information. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Zurich American Insurance Co. Policy#or Self-ins. Lic.#: WC5852405 Expiration Date: 01/01/2016 Job Site Address: 483 Park Hill Road City/State/Zip: Florence, MA 01062 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify un er the ains and penalties ofperjury that the information provided above is true and correct Signature: Date: Phone#: (860)535-3370 Official use only. Do not write in this area,to be completed by city or town oJfrciaL City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6,()titer Contact Person: Phone#: SECTION 8-CONSTRUCTION SERVICES 7 8:1'Licensed Construction Supervisor. Not Applicable ❑ Name of License Holder: Gary Beals 101487 License Number 61 Turnpike Road,Ashby, MA 01431 11/7/16 ddress Expiration Date 97§-855-8568 S1 el 1,11C e Telephone 8.Renistered Home I pavement Conftct+orr: Not Applicable ❑ Alteris Renewables dba RGS Energy 162709 Company Name Registration Number 106 Route 32,Suite 10, North Franklin,CT 06254 4/6/17 Addres Expiration Date Telephone 860-535-3370 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... M No...... ❑ 11 - Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families grid to allow such homeowner to engage wi individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures. A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors Accessory Bldg. ❑ Demolition ❑ New Signs [E3] Decks [0 Siding[0] Other[Ca] solar Brief Description of Proposed I�S /i5 aYv Work: Insudlatiun of a 3.06kW Wortmuunlerl solar army using 12 Trina TSM-255PA05.08 modules,12 Enphase M215-60-2LL-S22 micro inverters&all associated electrical work r✓ , Homeowner has existing grount mountedeystem installed by us back in 2013. a r ` cc Alteration of existing bedroom Yes No Adding new bedroom Yes X No ' Attached Narrative Renovating unfinished basement Yes x No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housing,complete the following: a. Use of building: One Family X Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage.of new-construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No . 1. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, Carolyn Grey as Owner of the subject property hereby authorize Alteris Renewables dba RGS Energy to act on my behalf, in all matters relative to work authorized by this building permit application. caa cignad authorization form attachad D h/c Signature of Owner D to Alteris Renewables dba RGS Energy as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Kim Hend?f Print Name Signature of Owner/Agent D to Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be tilled in by Building Department Lot Size Frontage sSCiaackti From Side L: R: L: R: Rear Building Height Bldg. Square Footage % Open Space Footage % (Lot area minus bldg&paved parking) i#of Parking Spaces Fill: volume&Location A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO 0 DONT KNOW YES IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DONT KNOW YES 0 IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO ® DONT KNOW ® YES e IF YES, has a permit been or need to be obtained from the Conservation Commission? if Needs to be obtained Obtained ��"� Date`Issued: p y C. Do any signs exist on the property? YES Q NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES NO on IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,excavation,or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES Q NO e IF YES;then a Northampton Storm Water Manaaement Permit from the DPW is renuire.d. Department use only City of Northampton Status of Permit: 1 � 'Irr'r+re ®n.tr4!nQr4 n..-ti --11na,. '+ vuIIJk uviiv 'vrSji l''aiiiiIt 212 Main Street Sewer/Septic Availability Room 100 Water/Well Availability, orthampton, MA 01060 Two Sets of Structural Plans 3 �}1 -587-1240 Fax 413-587-1272 Plot/Site Plans Other Specify. LAPPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office hila J LUX Urn 483 Paris Hill Road Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIPIAUTHORIZED AGENT 2.1 Owner of Record: Carolyn Grey 483 Park Hill Road,Florence,MA.01462 Name(Print) Current Mailing Address: 413-587-9750 see signed authorization form attached Telephone Signature 2.2 Authorized Asient: 11 Alteris Renewables dba k ' //���06 /�o�l h -?-), S,u�e IP, IVo,-A 1 aw Oai Cr oba,r/ Name(Print) Current Mailing Address: 860-535-3370 A Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by ermit a plicant 1. Building 3,000 (a)Building Permit Fee 2, Electrical 14,000 (b)Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) 5. Fire Protection 6. Total=(1 +2+3+4+5) 17,000 Check Number This Section For Official Use Only Building Permit Number: Issued: Signature: Building Commissioner/Inspector of Buildings Date File#BP-2016-0236 APPLICANT/CONTACT PERSON REAL GOODS SOLAR INC ADDRESS/PHONE 32 TAUGWONK SPUR RD UNIT Al2 STONINGTON06378(860)535-3370 Q PROPERTY LOCATION 483 PARK HILL RD MAP 43 PARCEL 033 001 ZONE THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid TMA Building,Permit Filled out Fee Paid Typeof Construction: INSTALL ROOF MOUNT 3.06 KW SOLAR ARRAY New Construction Non Structural interior renovations Addition to Existing- Accessory Structure Building Plans Included: Owner/Statement or License 101487 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION PRESENTED: (®Pgfiroved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management ly 4ure o Bu ici Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. 483 PARK HILL RD BP-2016-0236 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block:43 -033 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR PANELS BUILDING PERMIT Permit# BP-2016-0236 Project# JS-2016-000392 Est.Cost: $17000.00 Fee: $102.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: REAL GOODS SOLAR INC 101487 Lot Size(sq. ft.): 2787840.00 Owner: GRAY CAROLYN&GEORGE PEPPARD zoning: Applicant: REAL GOODS SOLAR INC AT. 483 PARK HILL RD Applicant Address: Phone: Insurance: 32 TAUGWONK SPUR RD UNIT Al2 (860) 535-3370 O Workers Compensation STONINGTONCT06378 ISSUED ON.91812015 0:00.00 TO PERFORM THE FOLLOWING WORK:INSTALL ROOF MOUNT 3.06 KW SOLAR ARRAY POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 9/8/2015 0:00:00 $102.00 212 Main Street,Phone(413)587-1240, Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner