Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
49-034
FLASHED L-FOOT MOUNT DETAILS CIO) y . ry FirstMark Advantage !. Lag Solt(Installer Provided) :, # — i 2. EPDM WasherswyH�y4xn s r. € a nw 4 r �:3. L-Foot (or other rail r 7...a M, attachment piece) y a 1 't }¢ 4. Square Aluminum Piece a_. ir- il{ ski` 'fit down) 1` K s� aY �¢r¢ k UNIRAC RAIL MOUNTING DETAILS CEN?+�NUr�C Olt ` 1.ALL ElEG7 O&WMAWMONS AS J'rtB(� Bolt PER 2014 NEC 8 w ELECTRIC COOS Mrd iFlar e Nur 2. w uouNnHC HARDWARE TO BE Clamp S 061GHED k IN5IWED AS PER Ctc']l MANUFACTURER WCUMENTAuGH 71 y� �r I R \ !.ALL SYSTEM D7NSRiUC110N SHALL BE "E lad �`. \ IMSTAIIED AS PER THE CURRENT \y j F18t7ge Nut ATP CJB E w euERND coot Beam Bolt s L-Foot Flange Nu �G 8aam A , 1 PERMrr ROEACE 12/23/14 NO. RF.I.E45EIREV, PATE GROUNDING DETAILS ,� \ `D AIZCyj� COLwfiC ' UGC-I e �' I 4 _ mounting -�) n p No,50216 7J ,,_ I clomps 1 0 NORTON ` µl MASSACHUSETTS FIRSTMARK ADVANTAGE j Niodvl t C Cjr PO BOX 297 NEW BOSTON, NH 03070 O��.1A5/ 603-714-0440 >` ;p" f c 4�us CHRIS PALAMES t•!ib> rH' 1' 65 HAMPTON,HILL 0100 U!C I 1 / NO 62 RTH ON M Intertek f ', +r•.r:=i Cer1Mr'n�la 1 �—.` an_ - /� UL 3L-J.rd 467 % "'y% 3``"`r "�' i�»'^ PROJECT: SHEEP N0. >✓^ ,. is'A_�,.+�'' �1 .7�'' l PALAM6.CHRIS rte\, DATE SCLAR,YIOUNimroil[anY I'tPe) NTS 11 INVERTER BRANCH CIRCUIT (11A AC) FirstMalrk 4 Advantage A 9 INVERTER BRANCH CIRCUIT (9A AC) 3 { A *t q y >lte� i T,g'f's D d a y#x A A �� c 10 INVERTER BRANCH CIRCUIT (10A AC) 3 B a 4 A -------------------------------------------------------------------- ROOFTOP CENIRMNOTES- HOME EXTERIOR 1.ALL 14 ELECTRICAL NEC A ELECTRIC AS PER 2014 NE d ALA ELFCIRIC CODE 9 2.ALL MOUNTING RARDWARE TO BE F DESIGNED&WSILLLED AS PER MANTffA RE DX;UMENIATION, 3.IN ALL SYS S PER THE CURRENT SHALL BE 6 INSTALLED AS PDI THE CURRENT APPLCABLE MA WILLING CODE TO UTILITY GRID C 11 C ----- ---------------------------------- F HOME INTERIOR O 8 1 1 7 E INTERNET 1 PERMrt RBFASE 14 5 ROUTER NO. RELEASE:REV. GATE F 1.95 KW KW DCL7 2 KW AC KW AC 305A PV BACKFEED BREAKER: 40A SOLAR BACKFEED BREAKER, 11 M250 CIRCUIT OPPOSITE UTILITY FEED, EQUIPMENT SCHEDULE 9 M250 CIRCUIT MAIN BREAKER/BUS BAR 200A 10 M250 CIRCUIT NO. QTY. DESCRIPTION OUTPUT=LUG ONLY 1Q 30 SUN EDISON SILVANTIS 265W MODULE FIRSTMARK ADVANTAGE Q 30 ENPHASE M250 MICRO-INVERTER PO BOX 297 ROOF MOUNTED WATERPROOF ENCLOSURE, ELECTRICAL NEW BOSTON, NH 03070 30 2 603-714-0440 JUNCTION BOX & ROOF PASS-THRU WIRING SCHEDULE ® 3 ENGAGE WATERPROOF CABLE TERMINATION NO. DESCRIPTION 1 FOR VANt.L. MAIN LUG ENPHASE BRANCH ONLY, PANEL CHRIS PALAMES ENPIiASE ENGAGE CABLE, MANUFACTURED WITH INVERTER 1 60A 240V AC DISCONNECT, 2 POLE, UNFUSED 658 PARK HILL RD. PLUGS, 4X#12 WIRE - U, L2, N, G © NORTI-IAMPTON, MA 01062 B 4X#12 THWN-2 IN 3/4-C OR MC CABLE 70 i REVENUE GRADE METER - PV PRODUCTION METER C INCOMING UTILITY CABLE (E) 8Q 1 (E) SERVICE PANEL, 20UA BUS & MAIN BREAKER [.7A QIECT: SFIEE7 N0. D EXISTING 120/240V HOME WIRING 90 1 (E) UTILITY METER, BI-DIRECTIONAL cNRis pV_4.0 E CATS ETHERNET CABLE ® 1 ENPHASE ENVOY - PV MONITORING DEVICE u F 4X#'8 THWN-2 W 1"C OR MC CABLE 1 UL LISTED SURGE ARRESTOR R DIACFlA1LLNE (E) UTILITY METER - (E) 200A RATED/200A MAIN BREAKER, EQUIPMENT SCHEDULE SCHLUMBERGER CL200 240V PANEL (BASEMENT) NO• QTY. DESCRIPTION 2 POLE 240V BREAKER SPACE FOR 30 n 165" UNIRAC SOLAR MOUNT RAIL Firs�Mart 60A 2P AC 40A BACKFEED BREAKER ro UNIRAC FLAT FLASHING ROOF MOUNT W L-FOOT DISCONNECT, 240V Advantage DAS (DATA ACQUISITION SYSTEM), 7,9 5 KW DC / 7 2 K y�, A� ENPHASE PV MONITORING & YV RGM (REVENUE GRADE METER) ��1, M ENPHASE M250 AC CIRCUIT COMBINER PANEL � �� ` 3X15A BACKFEED BREAKERS � rjt fdNE16L_H�S: 1.ALL EIECTRICN INSTMIAT)ONS AS PER 2014 NEC A MA ELECTRIC CODE 2.ALL MOUNTING HARDWARE TD BE D--HED&INSD11Ep AS PER 2"X8- RAFTER 16"O.C., MANUFACTURER DOCUMENTATION. 7:12 PITCH, 30.5 3.ALL SVSIFJA CONSIRUCRDN SHALL BE �I INSTALLED AS PER THE CURRENT APPLICABLE IN BILDING CODE SOLADECK OR EQUIV. ROOF a PENETRATION, SPLICE FROM ENGAGE CABLE TO TWHN-W. (TYP.) 4 3 i 13 .,ii } i6k1Iii11iiiii I Zfil 1 1 ' 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 T 1 1 f 1 1 1 1 1 2"X8" RAFTER 16"0.C., 111 t i j = i 1 � ` 1 111 1 1 1 1 1 1 1 1 1 1 1 1 1 Y61 1 1 1 E 1 1 1 ' 1 1 1 1 1 1 1 1 1 1 1 1 ; 6 ; , i 1 1 3 1 1 1 1 1 I I I I 1 ' A, — 7:12 PITCH, 30.5' 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I t l l l l l Vrt 1 1 1 1 1 1 1 1 1 1 1 ' 11 i ' ii 11 l i 1 1 1 iiiii i i 3 1 PETtMR RELEASE 12/23/14 1 1 1 1 1 1 1 1 .16 1 1 1 1 1 1 11�� 1 1 1 1 1 1 1 1 1 1 1 1 No. flELF.ASE IRF.v. DATE 4 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 t; ' JJ 1 4 1 1 1 1 1 1 1 1 1 1 1 1 11•,1 1 1 1 1 1 1 1 1 -A A141 6z12z" ED ARCS/ �`- —_ 1.5" RAIL OVERHANG AS PER 202 `+I�, c I GOL{yf�� FIRST OBOX D97NTAGE ` ! MFR. INSTRUCTIONS (TYP.) NEW BOSTON, NH 03070 SOLADECK OR EQUIV. ROOF "� 603-714-0440 PENETRATION, SPLICE FROM _ LJ No.50216 ENGAGE CABLE TO TWHN-W. (TYP.) #ii 0 HOI:TON ' z- tiA.SSACHUSETTS CHRIS PALAMES 658 PARK HILL RD. 1.5" RAIL OVERHANG AS PER '(JL�✓ /G V NORTHAMPTON, MA 01062 DECK AREA MFR. INSTRUCTIONS (TYP.) 55"•1 j�" Y,�-� ,,:. �� l PROJECT. ;HEFT NO. DATE.- CHRIS PV-3.0 it fF 12/2 12 23 14 NTS MOUNTING PLAN N1S EQUIPMENT SCHEDULE N0, QTY. DESCRIPTION }ryp iQ 30 SUN EDISON SILVANTIS 265W MODULE FirstMark (E) UTILITY METER — (E) 200A RATED/200A MAIN BREAKER, 30 ENPHASE M250 MICRO—INVERTER Advantage SCHLUMBERGER CL200 240V PANEL (BASEMENT) 2 POLE 240V BREAKER SPACE FOR 30A 2P AC 40A BACKFEED BREAKER DISCONNECT, 240V DAS (DATA ACQUISITION SYSTEM), 7.95 KW DC , 7.2 KW AC ENPHASE PV MONITORING Bc ROM (REVENUE GRADE METER) ENPHASE M250 AC CIRCUIT �v 15 COMBINER PANEL 3X15A BACKFEED BREAKERS w No.502`16 0 NORTON z MkSSACtiUSETTS F�C7.p1 O'r GENOW NOTES- 1. j FER 2 14 NEC CA. A EIECTI0NS AS FER 201!NE A AU EIECTPoC CODE. 2.ALL MOUNTING HARDWARE TO BE DESIGNED k INSIWED AS PER (. /.. MANUFACTURER DMCIMEIRARON. 1r V 3.ALL SYSTEM CJNSIRUCTM SHALL BE INSTALLID AS PC?THE CURRENT DF )NST& D IAA BJ THE COON: ENPHASE ENGAGE CABLE MFR. WITH LOCKING INVERTER CABLE SOCKETS ENPHASE ENGAGE CABLE 4X#12AWG (1-1, L2, N. G) TERMINATION (TYP) 9 INVERTER BRANCH CIRCUIT ENPHASE ENGAGE CABLE 1 MFR. WITH LOCKING INVERTER CABLE SOCKETS 2 4X#12AWG (L1, L2, N, G) 1 1 PERMR RREASE 12/23/14 2 ENPHASE ENGAGE CABLE NO. RFlEASE 1M. GA E TERMINATION (TYP) ENPHASE ENGAGE CABLE TERMINATION (TYP) FIRSTMARK ADVANTAGE 10 INVERTER BRANCH CIRCUIT PO BOX 297 NEW BOSTON, NH 03070 11 INVERTER BRANCH CIRCUIT ROOF PENETRATION PASS 603-714-0440 THRU/SPLICE BOX UNFUSED DECKAREA WATERPROOF ENCLOSURE X2 (SOLADECK OR EQUIVALENT) CHRIS PALAMES 658 PARK HILL RD. 155° NORTHAMPTON, MA 01062 PROJECT. EET NO. PALAWT3,CHRIS DATE PV-2.0 12/23/14 SCALE; PV LAYOUT NTS The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations W d I Congress Street, Suite 100 Boston, MA 02114-2017 s. www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): First Mark Advantage, LLC Address:26 Corriander Way City/State/Zip: Goffstown NH 03045 Phone #: 603-714-0440 Are you an employer? Check the appropriate box: Type of project(required): 1.0 I am a employer with 5 4. ❑ I am a general contractor and I 6. ❑New construction employees (full and/or part-time).* have hired the sub-contractors 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have 8. ❑ Demolition working for me in any capacity. employees and have workers' 9. ❑ Building addition [No workers' comp. insurance comp. insurance.$ required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t c. 152, §1(4),and we have no -1 PV Installation employees. [No workers' 13.FE Other comp. insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. #Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Paychex Insurance Agency Inc. /Hartford Fire Insurance Co. Policy# or Self-ins. Lic. #: 76 WEG GH0421 Expiration Date: 9/6/2015 Job Site Address: City/State/Zip: Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of perjury that the information provided above is true and correct. Si anature• Date: Phone #: Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1. Board of Health 2. Building Department 3. City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector 6. Other Contact Person: Phone#: � 3 z� DENNIS ` EL IN s CC7t7 rnerClaj ( S' IltiCj 7f Cf ;3 NO � s 58 Burt Street Norton MA 02760 January 79, 2075 Project Information: Palames Residence 659 Park Hill Road, Northampton, MA 01052 Client: First Mark Advantage PO Box 297, New Boston, NH 03070 To Whom it May Concern: This is to confirm that Dennis Colwell Architects, Inc. has completed structural design - including: review, and certification of location arrangement, and mounting for roof panels of this project as shown on First Mark Advantage's. drawings PV-1.0, PV-2.0,PV-3.0 and PV-5.0. We hereby certify that all elements, arrangements, and structural systems shown on the design documents do conform to the following code load requirements: I. Design in accordance to 8th Edition of the Commonwealth of Massachusetts State One&Two Family Building Code R301, R802 &all applicable sections. 2. Max spacing of the L-Foot is 4'-0" 1 Exposure category is exposure C 4. Wind loads with respect to 100 mph wind velocity 5. Snow loads as equivalent to 50psf ground snow load 6. Dead load of the added elements 4 psf max:. 7. Dead load of the existing roof 15 psf max. 8. Allowable stresses in the existing framing are all within acceptable values including as applicable: a. Rafters b. Roof trusses c. Hurricane clips,toe nailing, nail plates and other connections The PV panels are to be mounted to the roof using the Solar Mount system and connections as manufactured by UNIRAC, and following the procedures specified in the UNIRAC Solar Mount Code-Compliant Installation Manual 227.3 and First Mark Advantage's drawings, The drawings locate the proposed panels and all connection points to the roof framing. These have been reviewed and certified by Dennis Colwell Architects, Inc. and are included with this submission. The proposed system to be added to the roof includes the following: 1. Sun Edison Silvantis photovoltaic panels 2. Top mounting clamps, grounding clips, and logs for connecting the panels to the rails. 3. Aluminum extrusion Solar Mount rails and splices with #10 x3/4"self-drilling screws. 4. Stainless 3/8"x314" long to fasten the rails to the L-foot. 5. Alum. serrated 3x2x2"wide L-Foot with a stainless 5116 x 4" lag screw sealed and driven into the center of the rafter through a 8x1 2x0.032"aluminum ,flashing which is sealed to the roofing with roof cement. We herby certify that the existing roof structure and framing elements Of the subject residential dwelling will support the proposed photovoltaic system in conformance with accepted industry practice and in conformance with governing construction codes. Please feel free to contact us with any further questions. v�<< cl�l Sincerely, 4 C7 iJ NO.50216 ?.t �* /' NORTON 1 �-..i,;,.-..f' MASSACHUSETTS Ua Dennis M. Colwell, Jr, RA \`;1r NCAPB 70895 Serving MA PI CT NH ME MD &V,q �0 1' MP5 P�-- ,3-455-4466 info@dc-crchitect.com SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS-086870 5/13/15 Michael D. Hebert License Number Expiration Date Name of CSL Holder U List CSL Type(see below) 27 Lyon Street Type Description No.and Street U Unrestricted(Buildings up to 35,000 cu.ft.) Worcester MA 01604 R Restricted 1&2 Family Dwelling City/Town,State,ZIP M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances 603-714-0440 kevin @firstmarkadvantage.com 1 Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) 180267 10/28/16 First Mark Advantage LLC-Kevin Soucy HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name PO Box 297 kevin @firstmarkadvantage.com No.and Street Email address New Boston NH 03070 603-714-0440 City/Town,State,ZIP Telephone SECTION 6: WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes .......... 5a No...........❑ SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby ogze First Mark Advantage, LLC to act on my behalf,in all ma ters relative tow r authorized by this building permit application. Chris Palames Print Owner's Name(Electronic Signature) Date SECTION 7b: OWNER' OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby a t under the pains and penalties of perjury that all of the information contained in this applic ti n is true a cc r to to the best of my knowledge and understanding. Chris Palames Print Owner's or Authorized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq. ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq. ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" f C1 The monwealth of Massachusetts Bo of Building Regulations and Standards FOR MUNICIPALITY assachusetts State Building Code, 780 CMR USE N I Build' ermit Application To Construct,Repair,Renovate Or Demolish a Revised Mar 2011 ° One-or Two-Family Dwelling _ - This Section For Official Use Only B g Permit Number: Date Applied: LLq (5Z > X___:il ng Official(Print Name) Signature Date SECTION 1:SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers 659 Park Hill Road 1.1 a Is this an accepted street?yes x no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: Outside Flood Zone? Municipal❑ On site disposal system ❑ Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Chris Palames Florence MA 01062 Name(Print) City,State,ZIP 659 Park Hill Road 413-584-4393 judykrt@me.com No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK2(check all that apply) New Construction❑ Existing Building IN Owner-Occupied ❑ Repairs(s) ❑ Alteration(s) ❑ Addition ❑ Demolition ❑ Accessory Bldg. ❑ Number of Units I Other ❑ Specify: Brief Description of Proposed Work2: SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1.Building $ 30,723.50 1. Building Permit Fee: $ Indicate how fee is determined: ❑Standard City/Town Application Fee 2.Electrical $ 9,026.50 ❑Total Project Costa(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) Total All Fees: $ aJ Check No. heck Amount: Cash Amount: 6. Total Project Cost: $ 39,750.00 ❑Paid in Full ❑Outstanding Balance Due: File#BP-2015-0888 APPLICANT/CONTACT PERSON FIRSTMARK ADVANTAGE ADDRESS/PHONE P O BOX 297 NEW BOSTON03070(603)714-0440 PROPERTY LOCATION 659 PARK HILL RD MAP 49 PARCEL 034 001 ZONE THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out ta Fee Paid JOW1 Vol-U6 Typeof Construction: INSTALL ROOF MOUNTED 7.95KW SOLAR PV SYSTEM New Construction Non Structural interior renovations Addition to Existing Accessoa Structure Building Plans Included: Owner/Statement or License 86870 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INF MOTION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER:'§ Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Delay -- Sig o u' ing Of icial Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. 659 PARK HILL RD BP-2015-0888 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block:49-034 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category:ELECTRICAL BUILDING PERMIT Permit# BP-2015-0888 Project# JS-2015-001703 Est. Cost: $39750.00 Fee: $238.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: FIRSTMARK ADVANTAGE 86870 Lot Size(sq_ft.): 183605.40 Owner: PALAMES CHRIS&JUDY KIMBERLY Zonine: Applicant. FIRSTMARK ADVANTAGE AT: 659 PARK HILL RD Applicant Address: Phone: Insurance: P O BOX 297 (60 3) 714-0440 WC NEW BOSTONNHO3070 ISSUED ON:312612015 0:00:00 TO PERFORM THE FOLLOWING WORK.-INSTALL ROOF MOUNTED 7.95KW SOLAR PV SYSTEM POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 3/26/2015 0:00:00 $238.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner