Loading...
11A-006 (5) Registry ID: 728274506 Rating Number: HERS-326 Certified Energy Rater: Matt Turcotte Rating Date: 12/21/14 41 ChestnutAve Rating Ordered For: Leeds,MAO 1053 Estimated Annual Energy Cost Confirmed 5 Stars Plus Use MMBtu Cost Percent Confirmed Heating 33.5 $636 34% Uniform Energy Rating System Energy Efficient Cooling 2.0 $100 5% Hot Water 10.5 $149 8% 1 Star 1 Star Plus 2 Stars 2 Stars Plus 3 Stars_[3 Stars Plus F4 Stars 4 Stars Plus 5 Stars 5 Stars Plus Lights/Appliances 21.4 $989 53% 500-401 400-301 300-251 250-201 200-151 150-101 100-91 90 66 85-71 70 or Less Photovoltaics -0.0 $-0 -0% HERS Index: 53 Service Charges $0 0% General Information Total 67.5 $1873 100% Conditioned Area: 1938 sq.ft. HouseType: Single-family detached Conditioned Volume: 20238 cubic ft. Foundation: Conditioned basement This home meets or exceeds the minimum Bedrooms: 2 criteria for all of the following: Mechanical Systeriis Featura<s Heating: Fuel-fired air distribution,Natural gas,95.0 AFUE Cooling: Air conditioner,Electric,13.5 SEER. Water Heating: Instant water heater,Natural gas,0.95 EF,0.0 Gal. Duct Leakage to Outside: 24.00 CFM25. Ventilation System: Balanced:ERV,47 cfm,56.0 watts. Programmable Thermostat: Heating:Yes Cooling:Yes Building$hell Features„ Ceiling Flat: R-55.5 Slab: R-10.0 Edge,R-10.0 Under Sealed Attic: NA Exposed Floor: R-41.4 Vaulted Ceiling: NA Window Type: U-Value:0.290,SHGC:0.280 Above Grade Walls: R-19.3 Infiltration Rate: Htg:685 Clg:685 CFM50 Foundation Walls: R-12.0 Method: Blower door test Lights and Appliance Features TITLE Percent Interior Lighting: 100.00 Range/Oven Fuel: Natural gas Company Percent Garage Lighting: 100.00 Clothes Dryer Fuel: Electric Address Refrigerator(kWh/yr): 0.00 Clothes Dryer EF: 3.01 City,State,Zip Dishwasher Energy Factor: 0.89 Ceiling Fan(cfm/Watt): 0.00 Phone# The Home Energy Rating Standard Disclosure for this home is available from the rating provider. Fax# REM/Rate-Residential Energy Analysis and Rating Software v14.5.1 This information does not constitute any warranty of energy cost or savings. ©1985-2014 Architectural Energy Corporation,Boulder,Colorado. /�X — 0061" Air Leakage Property Organization HERS 41 Chestnut Ave Power House Energy Consulting Confirmed Leeds, MA 01053 413-835-5162 12/21/14 Matt Turcotte Rating No:HERS-326 Weather:Northampton, MA Rater ID:1497133 HERS-326 41 Chestnut Ave Builder registered.blg Keiter Builders Whole House Infiltration Blower Door Test Heating Cooling Natural ACH 0.12 0.09 ACH @ 50 Pascals 2.03 2.03 CFM @ 25 Pascals 437 437 CFM @ 50 Pascals 685 685 Eff. Leakage Area(sq.in) 37.6 37.6 Specific Leakage Area 0.00013 0.00013 ELA/100 sf shell (sq.in) 0.69 0.69 Duct Leakage Leakage to Outside Units ducts ductless CFM @ 25 Pascals 24 0 CFM25 / CFMfan 0.0205 0.0000 CFM25 / CFA 0.0160 0.0000 CFM per Std 152 N/A N/A CFM per Std 152 / CFA N/A N/A CFM @ 50 Pascals 38 0 Eff. Leakage Area (sq.in) 2.07 0.00 Thermal Efficiency N/A N/A Total Duct Leakage Units CFM25/CFA CFM25/CFA Total Duct Leakage 0.2933 0.0000 Ventilation Mechanical Balanced Sensible Recovery Eff. (%) 71.0 Total Recovery Eff. (%) 45.0 Rate(cfm) 47 Hours/Day 24.0 Fan Watts 56.0 Cooling Ventilation Natural Ventilation ASHRAE 62.2 - 2010 Ventilation Requirements For this home to comply with ASHRAE Standard 62.2 - 2010 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings, a minimum of 42 cfm of mechanical ventilation must be provided continuously, 24 hours per day. Alternatively, an intermittently operating mechanical ventilation system may be used if the ventilation rate is adjusted accordingly. For example, a 84 cfm mechanical ventilation system would need to operate 12 hours per day, as long as the system operates to provide required average ventilation once each hour. REM/Rate- Residential Energy Analysis and Rating Software v14.5.1 This information does not constitute any warranty of energy cost or savings. © 1985-2014 Architectural Energy Corporation, Boulder, Colorado.