37-038 (3) #4 Installing into an existing chimney
This method provides excellent venting for normal operation.
- This method also provides natural draft in the event of a
power failure. If the chimney condition is questionable*you
may want to install a liner as in method#7.
In some places in the US and Canada it is required that the
�\ vent pipe extend all the way to the top of the chimney.
\ Seal pipe joints with silicone or aluminum tape in addition to
the sealing system used by the manufacturer.
__. *The chimney should be inspected and cleaned before
installing your stove. If you discover that the chimney does
not have a clay tile liner or has cracks or flaking of the tile
jliner you will need to install a stainless steel liner within
I; ! the chimney. In most cases the inside diameter of this liner
should be 4". Either flexible or rigid liner may be used for
this purpose. Refer to Method 6 &7.
Be sure to design the venting so that it can be easily cleaned.
I
_] -
Figure 4.3 - ---
#5 Installing into an existing fireplace chimney
This method provides excellent venting for normal operation.
This method also provides natural draft in the event of a
power failure. If the chimney condition is questionable*you
may want to install a liner as in method#6.
In some places in the US and Canada it is required that the
\ vent pipe extend all the way to the top of the chimney.
Seal pipe joints with silicone or aluminum tape in addition to
\ the sealing system used by the manufacturer.
*The chimney should be inspected and cleaned before
installing your stove. If you discover that the chimney does
not have a clay tile liner or has cracks or flaking of the tile
liner you will need to install a stainless steel liner within
the chimney. In most cases the inside diameter of this liner
should be 4". Either flexible or rigid liner may be used for
this purpose. Refer to Method 6 &7.
The chimney should be sealed at the damper using a
steel plate. Kaowool, mineral wool or an equivalent non-
combustible insulation is recommended to be installed on top
of the sealing plate to reduce the possibility of condensation.
The connector pipe should extend through the smoke
i
\ chamber to the base or into the first flue tile.
--� Be sure to design the venting so that it can be easily cleaned.
Figure 4.4
__-..-----------
11 Harman® XXV Installation Manual R26 • 2004- 05/14 3-90-00684i
B. Clearances to Combustibles CAUTION: This appliance must be vented to the outside.
When selecting a location for the appliance it is important to Due to high temperatures,the stove should be placed out of traffic
consider the required clearances to walls (see Figure 3.2). and away from furniture and draperies.
WARNING! Risk of Fire or Burns! Provide adequate Children and adults should be alerted to the hazards of high
surface temperatures and should stay away to avoid burns to
clearance around air openings and for service access. Due skin and/or clothing.
to high temperatures, the appliance should be located out of Young children should be carefully supervised when they are in
traffic and away from furniture and draperies. the same room as the stove.
NOTICE:Illustrations reflect typical installations and are FOR Clothing and other flammable materials should not be placed on
DESIGN PURPOSES ONLY Actual installation may vary due or near this unit.
to individual design preference.
Place the stove away from combustible walls at least as far
as shown in Figures 3.2.
Note that the clearances shown are minimum for safety but do
not leave much room for access when cleaning or servicing.
Please take this into account when placing the stove.
3"/76mm
6.25"
159mm
° ° °
N
G)
01
� O °
3
Floor Protection
6.25"
Floor Protection 159mm
Figure 3.2
8 Harman® XXV Installation Manual—R26 2004-_ 05/14 3-90-00684i
C. Floor Protection Mobile Home Installation
Place the stove on a non-combustible floor protector that When installing this unit in a mobile home several
extends a minimum of 6 inches to the front (152mm), 6 requirements must be followed (Reference HUD Regulation
inches to the sides (152mm) and 0"(152mm) to the rear, #24CFR3280)-.
which is flush with the rear of the hopper. Front and side 1. The unit must be bolted to the floor.This can be done by
floor protection measurements are made from the firebox or using clips (part#2-00-677110B) and 1/4" lag screws.
window opening. Floor protection must also be positioned
under horizontal flue pipe,extending 2"(51 mm)beyond each 2. The unit must be connected to outside air. See page 17.
side of the pipe. 3. Floor protection and clearances must be followed as
NOTE for Canadian installation only: Per ULC-S627-00, shown above.
If installed on a combustible floor, the need to provide a 4. Unit must be grounded to the metal frame of the mobile
noncombustible floor protector covering the area beneath home.
the space heater and extending at least 17.72"(45.0mm)on 5. Chimney must meet requirements of CAN/ULC-S629,
the firing side and at least 7.87"(200mm)on the other sides. Standard for 650°C Factory Built Chimneys. Follow
In Canada,you may follow smaller U.S.floor protection Manufacturer's guidelines concerning height and
requirements ONLY if the user agrees to completely clearances to combustibles.Use the same manufacturer's
shut-down the appliance, and allow it to cool to where components to provide an effective vapor barrier where
all fire is extinguished and the combustion blower and the chimney or other component penetrates to the exterior
its indicator light shuts off, prior to opening the firebox of the mobile home.DO NOT MIX COMPONENTS FROM
door or ash door. DIFFERENT MANUFACTURERS. The top section of
The minimum floor protector material is 20 gauge sheet chimney and the chimney cap must be removable to a
metal. Other floor protector materials are ceramic tile, stone, maximum height of 13.5' for transport of the mobile home.
brick, etc. CAUTION:This appliance must be vented to the outside.
Floor protector minimum: 40" X 40" (1270mm X Alternate floor protector dimension maybe used as long
1270mm). as they satisfy the measurement requirements shown
*Floor protection dimensions for the front and sides are below.
measured from the appliance door opening in The United Minimum size floor protection for a corner installation
States. In Canada,the side dimension is measured from the hearth pad is 36"x 36".
widest part of the appliance.
l �S a
A
R Corner to edge dimension for corner installation floor protection.
j Sides 6" 200mm
K i Front 6" 450mm
L t Rear 0" 200mm
NOTE: Measurement"K" is measured o
from the glass in the US ONLY
L
ELL 45-7/8"
Floor Protection
J Floor Protection �6anada
USA
9 Harman® XXV Installation Manual R26 2004- 05/14 3-90-00684i
- e Commonwealth of Massachusetts
Department of Industrial Accidents
Office of Investigations
1 Congress Street,Suite 100
Boston,MA 02114-2017
Y www mass gov/dra
Workers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers
Aaalicant Information Please Print Legibly
Name (Business/Organization/Individual): BERNARDSTON FARMERS SUPPLY
Address:43 RIVER STREET
City/State/Zip:BERNARDSTON,MA 01337 Phone#:413-648-9311
Are you an employer?Check the appropriate box: Type of project(required):
L K I am a employer with 4. ❑ I am a general contractor and I
employees(full and/or part-time).* have hired the sub-contractors 6. New construction
2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling
ship and have no employees These sub-contractors have 8. ❑Demolition
working for me in an capacity. employees and have workers'
s Y p tY• 9. ❑ Building addition
[No workers' comp.insurance comp.insurance.*
required.] 5. ❑ We are a corporation and its 10.❑Electrical repairs or additions
3.❑ I am a homeowner doing all work officers have exercised their I I.[] Plumbing repairs or additions
myself. [No workers' comp. right of exemption per MGL 12.E]Roof repairs
insurance required.)} c. ]52,§1(4),and we have no
employees. [No workers' 13.❑Other
comp.insurance required.j
*Any applicant that checks box#t must also fill out the section below showing their workers'compensation policy information.
t Homeowners%%fio submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such.
Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have
employees. If the sub-contractors have employees,they must provide their workers'comp.policy number.
]'am an employer that is providing workers'compensation Insurance for ntv employees. Below is the policy and job site
information.
Insurance Company Name:PEERLESS INSURANCE
Policy#or Self-ins. Lic.#:WC8165644 Expiration Date:711114
Job Site Address: v�r��C '20d-,4 /Ji City/State/Zip: 0/-c/tt AI-A 0/0"
Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date).
Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a
fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine
of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of
Investigations of the DIA for insurance coverage verification.
I do hereby certffit der the pains andpenalfies of perjury that the information provided above is true and correct.
SignatureQ- -�✓, �: L� �. Date:
Phone#
official use only. Do not write in this area,to be completed by city or town official.
City or Town: Permit/License#
Issuing Authority(circle one):
1. Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector
6.Other
Contact Person: Phone#•
of Northampton _
Massachusetts --
C Fi I�EP of $UIW22IG 22gNr=rxGWS
1= r Np Rh.i l v r:
EC�12 Street • Municipal ding
ions Northampton, iX 01060ij
GINOLC OR Two i:AmiLY S[lL in FUEL APPLIANCE PERMIT APPLICATION
FOR WOOD, COAL, PELLET, CORN, STRAW OR SIMILAR STOVES, OR FIREPLACE INSERTS
Permit Fee: $25.00 Check#
A PLEASE TYPE OR PRINT ALL INFORMATION
9. Name of Applicant 1-)O U7/L S L A/j -r -rki c� P--t-f c Y!'
Address: ,75- of rr� -3d 41 /1 Telephone: 0.1 at��
2 Owner of Property: G -Ili n (, )j //
Address: i?� %fS� i I I � Telephone:
3. Status of Applicant Owner z Contractor
4- Type or Brand of Stove: 1%gRr'(A 1l/ X"� y
T
If applicant is not the homeowner
Construction Supervisor's License Number 9`�y�� Expiration Date
Home Improvement Contractor Registration Number 16 0 j,5,O Expiration Date
All Applicants must complete a Workers Compensation Insurance Affidavit before we can issue a permit
5. Certification:t hereby certify that the information contained herein is true and accurate to the best
of my knowledge. /
DATE: -0 -IV APPLICANT'S SIGNATUREi'`�---® L=
DATE: 6 `�:3/- i t HOMEOWNER'S SIGNATURE -
APPROVED
DATE: BUILDING OFFICIAL
286 ROCKY HILL RD BP-2015-0015
GIs#: COMMONWEALTH OF MASSACHUSETTS
Map:Block: 37-038 CITY OF NORTHAMPTON
Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
Permit: Buildinq DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
Category: woodstove BUILDING PERMIT
Permit# BP-2015-0015
Project# JS-2015-000021
Est.Cost:
Fee: $25.00 PERMISSION IS HEREBY GRANTED TO:
Const. Class: Contractor: License:
Use Group: BERNARDSTON FARMERS SUPPLY 160452
Lot Size(sq. ft.): 14984.64 Owner: WILLIAMS DOUGLAS A&ELAINE E
Zoning: Applicant. BERNARDSTON FARMERS SUPPLY
AT. 286 ROCKY HILL RD
Applicant Address: Phone: Insurance:
43 RIVER ST (413) 648-9311 () WC
BERNARDSTONMA01337 ISSUED ON.7/2/2014 0:00:00
TO PERFORM THE FOLLOWING WORK:INSTALL HARMAN XXV PELLET STOVE
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter:
Footings:
Rough: Rough: House# Foundation:
Driveway Final:
Final: Final:
Rough Frame:
4
Gas: Fire Department Fireplace/Chimney:
Rough: Oil: Insulation:
Final: Smoke: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Certificate of Occupancy Signature:
FeeType: Date Paid: Amount:
Building 7/2/2014 0:00:00 $25.00
212 Main Street, Phone(413)587-1240, Fax: (413)587-1272
Louis Hasbrouck—Building Commissioner