35-069 (3) I le I A91 W 1 y: J _ i .3 s a \ P pf 9 j + ESR•1331 I Most Widely Accepted and Trusted Page 3 of 3 4-116' I 5' FROM EDGES 4„ For SI: 1 inch=25.4 mm. FIGURE 1—BRACKET DETAIL G I i t A –RIM BOARD * i B –SHEATHING / C –SIDING D –LARGE BRACKET FLANGE ATTACHED TO / C HOUSE ,` G E –BRACKET`NEB '� F –DECK LEDGER \� G – BOLTS Note: Mater-resistive barrier and flashing are not � shown for Clarity. t = I t I F CG B FIGURE 2—INSTALLATION DETAIL 6/2' 914 Installation Instructions-Maine DeckBraCket-Minot,Maine w, �r W d ;. ' f � A small slot is cut in the siding for the web of The slot is small so as to leave no significant the bracket to go through. entry point for water or insects. k ,x. The slot is then caulked with silicone, caulking The Maine Deck Brackets make a nice neat sealing out moisture and insects. job on the building. V N"� The brackets are ready to receive the deck The double ledger is used so that you can framing. span the distance between brackets safely. i4f ra� { i s � ny . httn•/AAAAw rlarkhrarkat rrun/nrintahlc htrAlf 612,R014 Installation Instructions-Maine Deck Brad et-Minot,Maine I aiDe ec rac e 0 kR k t Maine Deck Bracket® Installation Instructions fl CLICK HERE FOR PRINTABLE INSTRUCTIONS Product application details: Our Products provide a Revolutionary method of attaching Decks, Stairs, Signs and other appendages to buildings. Both the Bracket AND the attachment system methods are patented. f xj n� 4 The sheithing is cut out to expose the box sill. The Maine Deck Bracket is bolted to the sill With 1/2" bolts,washers on the inside. http:/AmmAt.decldxacket.condprintabie.hbA# 1/3 ESR-1331 1 Most Widely Accepted and Trusted Page 2 of 3 5.4 The maximum on-center spacing of the Maine Deck 5.8 Rim joists shall be constructed with continuous Bracket shall be 8 feet(2428 mm). fastening and support in accordance with IBC Table 5.5 Design calculations and details in accordance with 2304.9.1. Details to resist the effects of torsion in the Section 4.2 shall be submitted to the code official at rim joist shall be submitted to the code official. the time of permit application. The calculations shall 6.0 EVIDENCE SUBMITTED be prepared by a registered design professional Data in accordance with the ICC-ES Acceptance Criteria where required by the statutes of the jurisdiction in for Joist Hangers and Similar Devices (AC13), dated which the project is to be constructed. October 2006(editorially revised April 2008). 5.6 The design and construction of the deck supported by 7.0 IDENTIFICATION the deck bracket and the supporting construction of the deck bracket, including framing members and The Maine Deck Bracket described in this report shall be foundations, are outside the scope of this report and identified with the manufacturer's name (Maine Deck shall comply with the applicable code. Bracket) and/or trademark, the product name and the 5.7 The compatibility of the bracket with preservative- evaluation report number(ESR-1331). pressure-treated or fire-retardant-treated wood is outside the scope of this report. TABLE 1—MAXIMUM ALLOWABLE DESIGN CAPACITIES PER BRACKET'2.3,4 RIM BOARD AND LEDGER VERTICAL DOWNLOAD TORSIONAL CAPACITY LATERAL CAPACITY THICKNESS CAPACITY (PERPENDICULAR TO THE (PERPENDICULAR TO WEB (inches) (PARALLEL TO WEB FACE) FLANGE FACE) FACE) (Ibf) (in-Ibf) (Ibf) 11/2 1000 390 1115 3 1160 390 1115 For SI: 1 inch=25.4 mm, 1 Ibf=4AN,1 in-Ibf=0.112 N-m. 'Allowable capacities are based on four 1/2-inch-diameter-by-4112-inch-long hex head bolts through the rim board and four'/2-inch-diameter-by- 3-inch-long hex head bolts through the deck/balcony header complying with ASTM A 307 Grade A or SAE Grade 2,with 1-inch-diameter washers on all wood surfaces.If longer length bolts are required,calculations shall be submitted to the code official to verify compliance with the allowable design loads shown above. 2Capacities shall be multiplied by a factor of 0.4 for wet service in accordance with the NDS. 3Capacities are based on deck joist spacing not exceeding 24 inches(610 mm)on center. °Capacities are limited to No.2 Southern pine or Douglas fir–larch solid sawn lumber with a specific gravity of 0.50 or greater. s C C VICEER Most Widely Accepted and TrustedM ICC-ES Evaluation Report ESR-1331 Reissued October 1, 2012 This report is subject to renewal November 1, 2014. www.icc-es.org 1 (800)423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council° DIVISION: 06 00 00—WOOD,PLASTICS AND to the use of '/2-inch-diameter (12.7 mm) hex head COMPOSITES bolts and 1-inch-diameter (25.4 mm) washers. The bolts Section:06 05 23—Wood, Plastic,and Composite and washers shall be hot-dipped zinc-coated galvanized Fastenings steel complying with the requirements of ASTM A 307 Grade A or SAE Grade 2 (see Footnote 1 of Table 1). See REPORT HOLDER: Table 1 for the maximum allowable design loads per bracket. MAINE DECK BRACKET CO. Design information provided to the code official shall 176 GRANGE AVENUE include the following: MINOT,MAINE 04258 (207)345-8501 • Number, location and spacing of brackets. www.deckbracket.com . Maximum design loads anticipated at each bracket, in bracketCrDmegalink.net accordance with the applicable code. EVALUATION SUBJECT: e Allowable loads of the brackets, as specified in this report. MAINE DECK BRACKET • Size, grade, type, quantity and corrosion protection 1.0 EVALUATION SCOPE covering of the bolts used to secure the brackets to the deck and building framing members,consistent with this Compliance with the following codes: report. ■ 2009 and 2006 International Building Codee(IBC) a Species, grade, size, and specific gravity of the wood ■ 2009 and 2006 International Residential Code'(I RC) members to which the bracket is attached. ■ BOW National Building Code/1999(BNBC) 4.3 Installation: Property evaluated: Refer to the manufacturer's published installation Structural instructions for installation details. For installation on an existing structure, an area of the exterior wall covering 2.0 USES equivalent to the area of the bracket face shall be removed The Maine Deck Bracket is used to attach an exterior deck from the framing at the attachment location. Weather or balcony ledger to a solid sawn lumber rim board of an protection shall be installed in accordance with IBC Section existing or new structure. 1403.2, IRC Section R703.1 or BNBC Section 1404.3. 3.0 DESCRIPTION 5.0 CONDITIONS OF USE The bracket is manufactured from 1/4-inch-thick (6.4 mm) The Maine Deck Bracket described in this report complies aluminum alloy Grade 6061-T6, complying with ASTM B with, or is a suitable alternative to what is specified in, 221. The bracket is H-shaped and predrilled with four those codes listed in Section 1.0 of this report, subject to 9/16-inch-diameter (14.3 mm) holes on each flange-face. the following conditions: See Figures 1 and 2 for illustrations of the bracket. 5.1 Installation shall comply with this report, the 4.0 DESIGN AND INSTALLATION manufacturer's published installation instructions and 4.1 General: the applicable code. In the event of a conflict between the manufacturer's published installation instructions Installation of the Maine Deck Bracket shall comply with and this report,this report shall govern. this report and the manufacturer's published installation instructions. The manufacturer's published installation 5.2 Allowable loads in Table 1 are based on brackets instructions shall be available at the jobsite at all times attached to nominally 2-inch-thick-by-6-inch-wide No. during installation. 2 southern pine or Douglas fir–larch solid sawn 4.2 Design: lumber with a specific gravity of 0.50 or greater. The bracket shall be bolted to the wood framing member 5.3 Design loads determined in accordance with the (rim board) and to the wood deck header or ledger. applicable code shall not exceed the allowable loads Allowable design loads indicated in this report are limited for the Maine Deck Bracket as set forth in Table 1. ICC-ES Evaluation Reports are not to he construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warrant),by ICC Evaluation Service,LLC,express or implied,as to any.ftnding or other matter in this report,or as to any product covered by the report. Copyright©2012 Page 1 of 3 4 8 r � i _ _ 7 { a s \'7° City of Northampton Massachusetts J Iy I h 3. DEPARTMENT OF BUILDING INSPECTIONS �, .fib• 212 Main Street • Municipal Building J� Northampton, MA 01060 sst n°: jit INSPECTOR Louis Hasbrouck Chuck Miller Building Commissioner Assistant Commissioner HOME OWNER EXEMPTION ACKNOWLEDGEMENT The State of Massachusetts allows the homeowner the right under 780CMR 108.3.4 to act as his/her construction supervisor. The state defines "Homeowner" as, " Person(s) who owns a parcel on which he/she resides or intends to be,a one or two family dwelling, attached or detached structures accessory to such use and/or farm structures. A person who constructs more than one home in a two- year period shall not be considered a home owner." The building department for the City of Northampton wants any person(s) who seek to use the home owner exemption, to act as their own construction supervisor, to be aware that by doing so you become responsible for compliance with state building codes and regulations. The inspection process requires that the building department be called to inspect work at various stages, which include foundation/footings (before backfill), sonotube holes (before pour), a rough building inspection (before work is concealed), insulation inspection (if required) and a final building inspection. The building department requires these inspections before the work is concealed, failure to secure these inspections can result in failure to obtain a certificate of occupancy until the work can be inspected. If the homeowner hires other trades to perform work (electrical, plumbing & gas) the homeowner will be responsible to make sure that the trades hired secure their proper permits in conjunction to the building permit issued, and that they get their required inspections. Failure of the individual trades to secure the permits and inspections as required can DELAY the project until such time as the proper permits and inspections are made understand the above. (Home owner/resident's signature requesting exemption) I will call to schedule all required building inspections necessary for the building permit issued to me. Date Address of work location �; The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations 600 Washington Street Boston, MA 02111 www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Address: City/State/Zip: Phone #: Are you an employer? Check the appropriate box: Type of project(required): 1.❑ I am a employer with 4. ❑ I am a general contractor and I 6. ❑New construction employees (full and/or part-time).* have hired the sub-contractors 2.❑ I am a sole`proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have g, 0 Demolition working for mein any capacity. employees and have workers' 9 ❑ Building addition [No workers' comp. insurance comp. insurance. 5. ❑ We are a corporation and its 10.F-1 Electrical repairs or additions required.] 3.❑ I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t c. 152, §1(4), and we have no employees. [No workers' 13.❑ Other comp. insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. tHo meowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. $Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Policy#or Self-ins. Lic.#: Expiration Date: Job Site Address: City/State/Zip: Attach a copy of the workers' compensation policy declaration page (showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties ofperjury that the information provided above is true and correct. Signature: Date: Phone#: Official use only. Do not write in this area, to be completed by city or town official City or Town: Permit/License# Issuing Authority(circle one): 1. Board of Health 2.Building Department 3. City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6. Other Contact Person: Phone#: s SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable £ Name of License Holder: License Number Address Expiration Date Signature Telephone `" Not Applicable £ °9,Registered Home Improvement Contractor: _ _, Company Name Registration Number Address Expiration Date Telephone SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... £ No...... £ 11. Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780 Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures,A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the buildins permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance7ith the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetes General Laws Annotated. Homeowner Signature. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House [] Addition C] Replacement Windows Alteration(s) ❑ Roofing Or Doors I] Accessory Bldg. ❑ Demolition ❑ New Signs [❑] Decks [ice Siding [❑] Other[❑] Brief Description of Proposed , Work: - - - r Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet sa, If New house and.or:ad"on to existing h`ousing, complete the fot(owing a. Use of building:One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. 1. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, as Owner of the subject property hereby authorize to act on my behalf, in all matters relative to work authorized by this building permit application. Signature of Owner Date I, as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Print Name Signature of Owner/Agent Date . . . Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This coltirrin to be filled in by Building Department Lot Size Frontage _j Setbacks Front Building Height Bldg. Square Footage Open Space Footage % (Lot area minus bldg&pav d #of Parking Spaces (volume&Location) A. Has a Special Permit/Vahonce/Rnding ever been issued for/on the site? NO 0 DONTKNOW 0 YES 0 |F YES, date iouedJ � IF YES: Was the permit recorded at the Registry of Deeds? NO K ] DONTKNO�' YES�� IF YES: enter Book Page( and/or Oocument� �� � �� � B. Does the site contain a brook, body of water orwetlands? NO �~� DONTKN0YV �~� YES �~� IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs tobeobtained �~� Obtained »°� Date � «�� �~� ' C. Do any signs exist on the pnoperty ��� YES �=� NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES NO 0 IF YES, describe size' type and location: ' E Will the construction activity disturb . grading, excavation, or filling)over 1 acre orisd part ofo common plan , that will disturb over 1acre? YES � 3 NO K � IF YES,then a Northampton Storm Water Management Permit from the DPW is required. ^ — ��'� C, ( , r fDepartmeht,useorily _ ! r � r t C�� II \ City of Northampton Sta'us,ofP±~rmtt s " � k s,r Building Department P JUN - 2 2014 212 Main Street SewerlSepticAyaiCa6ll�ty Room 100 1Nater/V�efilAya�lablllty 4Y Northampton, MA 01060 Twa Sets of Structural Plans E ct(ic, Pwrnr rig&Gas Inspections N°''r",,!''`' I,Ia°'' 13-587-1240 Fax 413-587-1272 PIot/Site Plans Oir 5pec5fy APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE.INFORMATION 1.1 Property Address: r Thls section to be completed by office Map Lot -:.: Urnt Zone Overlay District Elm St:District CB Distract SECTION 2 PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Name(Print)_ Current Mailing Address: Telephone Signature r 2.2 Authorized Agent: Name(Print) Current Mailing Address: Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS. Item Estimated Cost(Dollars)to be Official Use Only completed by ermit applicant 1. Building (a) Building Permit Fee 2. Electrical (b) Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) 5. Fire Protection 6. Total=(1 +2+3+4+5) Check Number This Section For Official Use Only Date Building Permit Number: Issued: Signature: Building Commissioner/Inspector of Buildings: Date 7S�N1� 0 File#BP-2014-1283 APPLICANT/CONTACT PERSON TOM DAWSON-GREENE f Las'- ADDRESS/PHONE P O BOX 556 CHESTERFIELD (413)296-4421 PROPERTY LOCATION 906 RYAN RD MAP 35 PARCEL 069 001 ZONE THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid Typeof Construction: CONSTRUCT 12 X 15 DECK New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON IN_F fiMATION PRESENTED: (/Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management oliti n Delay S� ature o uilding Crhicial Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of Planning&Development for more information. 906 RYAN RD BP-2014-1283 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 35 -069 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: Deck BUILDING PERMIT Permit# BP-2014-1283 Project# JS-2014-001396 Est. Cost: $2000.00 Fee: $50.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: Homeowner as Contractor Lot Size(sq. ft.): 11979.00 Owner: TOM DAWSON-GREENE Zoning: Applicant: TOM DAWSON-GREENE AT. 906 RYAN RD Applicant Address: Phone: Insurance: P O BOX 556 (413) 296-4421 CHESTERFIELDMA01012 ISSUED ON:61912014 0:00:00 TO PERFORM THE FOLLOWING WORK.-CONSTRUCT 12 X 15 DECK POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 6/9/2014 0:00:00 $50.00 212 Main Street, Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner