Venting
#3 Installing into an existing chimney
This method provides excellent venting for normal operation.
This method also provides natural draft in the event of a
power failure. If the chimney condition is questionable"you
--- may want to install a liner as in method#7.
*The chimney should be inspected and cleaned before
installing your stove. If you discoverthat the chimney does not
have a clay tile liner or has cracks or flaking of the tile liner you
will need to install a stainless steel liner within the chimney.
In most cases the inside diameter of this liner should be 4".
Either flexible or rigid liner may be used for this purpose.
Be sure to design the venting so that it can be easily cleaned.
THE CHIMNEY MUST BE OF A TYPE SUITABLE FOR
SOLID-FUEL BURNING.
A WARNING
THE CHIMNEY AND CONNECTOR MUST BE
V
MAINTAINED IN GOOD CONDITION AND KEPT CLEAN.
Fig. 10
#4 Installing into an existing fireplace chimney
This method provides excellent venting for normal operation.
\ This method also provides natural draft in the event of a
power failure. If the chimney condition is questionable"you
may want to install a liner as in method#6.
"The chimney should be inspected and cleaned before
\ installing your stove. If you discoverthatthe chimney does not
have a clay tile liner or has cracks or flaking of the tile liner you
\ will need to install a stainless steel liner within the chimney.
In most cases the inside diameter of this liner should be 4".
Either flexible or rigid liner may be used for this purpose.
- The chimney should be sealed at the damper using a
steel plate. Kaowool, mineral wool or an equivalent non-
combustible insulation is recommended to be installed on top
of the sealing plate to reduce the possibility of condensation.
!! The connector pipe should extend through the smoke
chamber to the base or into the first flue tile.
/I
Be sure to design the venting so that it can be easily cleaned.
Fig. 11
11 P68 Pellet Stove 3-90-00688R2803/14
a '
Requirements for Terminating the Venting I. The clearance to service regulator vent outlet must be a
WARNING: Venting terminals must not be recessed into a minimum of 6 feet.
wall or siding. J. The clearance to a non-mechanical air supply inlet to the
NOTE: Only PL vent pipe wall pass-throughs and fire stops building or the combustion air inlet to any other appliance
should be used when venting through combustible materials. must be a minimum of 48".
NOTE: Always take into consideration the effects of the K. The clearance to a mechanical air supply inlet must be a
prevailing wind direction or other wind currents that may minimum of 10 feet. (with outside air installed,6 feet)
cause flyash and/or smoke when placing the termination vent. L. The clearance above a paved sidewalk or a paved
In addition, the following must be observed: driveway located on public property must be a minimum
of 7 feet.
A. The clearance above grade must be a minimum of 12". M.The clearance under a veranda, porch, deck or balcony
B. The clearance to a window or door that may be opened must be a minimum of 12 inches. (See B.)
must be a minimum of 48" to the side, 48" below the NOTE: The clearance to vegetation and other exterior
window/door, and 12"above the window/door. combustibles such as mulch is 36" as measured from the
C. A 12" clearance to a permanently closed window is center of the outlet or cap.This 36"radius continues to grade
recommended to prevent condensation on the window. or a minimum of 7 feet below the outlet.
D. The vertical clearance to a ventilated soffit located above Certain Canadian and or Local codes or regulations may
the terminal within a horizontal distance of 2 feet(60 cm) require different clearances.
from the center-line of the terminal must be a minimum A vent shall not terminate directly above a side-walk or
of 18". paved driveway which is located between two single family
E. The clearance to an unventilated soffit must be a minimum dwellings and serves both dwellings.
of 12". Only permitted if veranda, porch, deck, or balcony is fully
F. The clearance to an outside corner is 11"from center of open on a minimum of 2 sides beneath the floor.
pipe.
G. The clearance to an inside corner is 12".
NOTE: Where passage through a wall, or partition of
H. A vent must not be installed within 3 feet (90 cm) above combustible construction is desired,the installation shall
a gas meter/regulator assembly when measured from the conform to CAN/CSA-B365. (if in Canada)
horizontal center-line of the regulator.
-4 6
D A
�� isme coer
Detail
B ono �C B
ed
nosed B Porch or Deck
` F B openaMe pied r Open able or Fixed
L r Dosed 1.
0
Openable
nx
C
Sidewalk 4 B I-- M
A K
=Vent Terminal 0 =Air Supply Inlet ® =Area where termination is not permitted
7 P68 Pellet Stove 3-90-00688R2803/14
Installation
Installing Alternate floor protector
Place the stove on a noncombustible type floor or floor protector dimension may be used
that extends a minimum of 6 inches (152mm)to the front of the as long as they satisfy 9,,(228mm)-
the measurement
load door opening, 6 inches (152mm) to the sides of the door 13"(330mm)
requirements shown
opening, and 6 inches to the rear. Floor protection must also below.
extend 2 inches(51 mm)beyond each side of any horizontal flue Minimum size floor
protection for a corner
pipe. The minimum floor protector material is 20 gauge sheet installation is 38"x 38°.
metal. Other floor protector materials are ceramic tile, stone, Clearance shown as 9"
brick, etc. with optional side shields
NOTE for Canadian installation only: Per ULC-S627-00, installed. \\�
If installed on a combustible floor, the need to provide a 9"(228mm)With Side Shields W N
noncombustible floor protector covering the area beneath the 13"(330mm)Without Side Shields o c
space heaterand extending at least 17.72"(450mm)on the firing 3
side and at least 7.87" (200mm) on the other sides. Fig.3
In Canada, you may follow smaller U.S. floor protection
requirements ONLY if the user agrees to completely shut-
down the appliance, and allow it to cool to where all fire is i I
extinguished and the combustion blower and its indicator 2"(51 mm)
light shuts off,prior to opening the firebox door or ash door.
r
Place the stove away from combustible walls at least as far as 14"(355mm)with
shown in Figures 3 and 4. Please note the difference in side wall side shields
clearance with and without side shields. ° ------- 14"(355mm)
508mm
Note that the clearances shown are minimum for safety but do not 20"( ) I 20°(508mm)
shields
leave much room for access when cleaning or servicing. Please without side
take this into account when placing the stove �
Connect the power cord to a 120 VAC.60Hz grounded receptacle. J
(A surge protector is recommended to protect the circuit board.)
Also be sure that the polarity of the outlet that the stove is plugged
into is correct. 36"(914mm)
Prior to installing the flue pipe, connect a draft meter. (The Fig.4 --
draft meter must have a minimum range of 0 - .5") Record the Minimum size rectangular floor protection (USA) is 33"
first reading. Connect flue pipe to stove and be sure all doors Deep By 25"Wide.
and windows in the home are closed. Record the second draft
reading . If the second reading is more than .05" lower Floor protection dimensions for the front and sides
than the first reading, check for possible restrictions or the need are measured from the appliance door opening in
for outside air(see page 10). For more information on the draft The United States. In Canada, the side dimension is
test procedure, refer to Page 21. measured from the widest part of the appliance.
Mobile Home Installation
When installing this unit in a mobile home, several requirements
FkN
must be followed: i an
1.The unit must be bolted to the floor.This can be done with 1/4'
lag screws through the 2 holes in the base plate. Sides 6" 200mm
2.The unit must also be connected to outside air. See page 10. -
3. Floor protection and clearances must be followed as shown. K Front 6" 450mm
4. Unit must be grounded to the metal frame of the mobile home. -- - - -- - - ---� - -
5. Be sure to follow the vent manufacturer's guidelines to provide L Rear 6" 200mm
for a sufficient vapor barrier where the flue penetrates the
outside. NOTE:
6.The top section of any chimney or venting must be removable Measurement"L"
to a height of 13' (3.9 M)to allow for transport. is measured from
7. The factory-built chimney must conform to CAN/ULC-S629, the pedestal base
Standard for 650°C Factory-Built Chimneys. in the US ONLY L
CAUTION: This appliance must be vented to the outside.
Clothing and other flammable materials should not be placed on
or near this unit. NOTE:
Measurement"K"
A WARNING t measured from
the glass in the
US ONLY
THE STRUCTURAL INTEGRITY OF THE MANUFACTURED CANADA
HOME FLOOR, WALL, AND CEILING/ROOF MUST BE
MAINTAINED.
______ K
USA ' � FLOOR PROTECTOR
DO NOT INSTALL IN SLEEPING ROOM. J
3-90-00688R2803/14 P68 Pellet Stove 6
City of Northampton
Massachusetts '� �r
4` $ARTMENT OF BUILDING INSPECTIONS
2014
1 !Q•32 Main Street • Municipal Building 4) �b
.� Northampton, MA 01060 �b
Electric, Plumbing&Ga nspections
Northampton. MA 01060
SINGLE OR TWO FAMILY SOLID FUEL APPLIANCE PERMIT APPLICATION
FOR WOOD, COAL, PELLET, CORN, STRAW OR SIMILAR STOVE22S, OR FIREPLACE INSERTS
Permit Fee: $25.00 Check # d✓
PLEASE TYPE OR PRINT ALL INFORMATION n
1. Name of Applicant: �0 U4�it S L �{��jcc . .6-e1-"f Q 57 r;Q
't_3 ` V�,J, ,�r° na rn 5 Y an n'►i i 3 a S
Addres . _ _ Telephone: '`�..� 7r
2. Owner of Property: —_/QV/� k S jO /
Address: 5-6- �i7zS'/�'9'�1<� '�D. ,Ct;'�-S Telephone: 5//-8
3. Status of Applicant: Owner Contractor
4. Type or Brand of Stove:. 1//Id�rr Fl1✓ `�f `" 'f 1r - 'eC'm aft 11 a�� &JOP� 5'TnV�
'900 in_j in'�c� ISflA7 ,rY,a '�on ry cdtr rnr1Ty,
If applicant is not the homeowner:
Construction Supervisor's License Number 9701 Expiration Date
Home Improvement Contractor Registration Number Expiration Date
All Applicants must complete a Workers Compensation Insurance Affidavit before we can issue a permit
5. Certification: I hereby certify that the information contained herein is true and accurate to the best
of my knowle ge.
DATE: 'Y APPLICANT'S SIGNATURE
v
DATE: q / L HOMEOWNER'S SIGNATURE C
APPROVED
DATE: BUILDING OFFICIAL
55 CHESTERFIELD RD BP-2014-1116
GIS#: COMMONWEALTH OF MASSACHUSETTS
Man.Block: 16A-019 CITY OF NORTHAMPTON
Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
Category: woodstove BUILDING PERMIT
Permit# BP-2014-1116
Project# JS-2014-001896
Est. Cost:
Fee: $25.00 PERMISSION IS HEREBY GRANTED TO:
Const. Class: Contractor: License:
Use Group: BERNARDSTON FARMERS SUPPLY 99401
Lot Size(sq. ft.): 31014.72 Owner: K1SLO PAUL M&BARBARA A
Zoning: URA(100)/ Applicant. BERNARDSTON FARMERS SUPPLY
AT. 55 CHESTERFIELD RD
Applicant Address: Phone: Insurance:
43 RIVER ST (413) 648-9311 () WC
BERNARDSTONMA01337 ISSUED ON:412512014 0:00:00
TO PERFORM THE FOLLOWING WORK.-INSTALL HARMAN P68 PELLET STOVE IN
EXISTING MASONRY CHIMNEY
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter:
Footings:
Rough: Rough: House# Foundation:
Driveway Final:
Final: Final:
Rough Frame:
Gas: Fire Department Fireplace/Chimney:
Rough: Oil: Insulation:
Final: Smoke: Final: