16A-019 \� Venting #3 Installing into an existing chimney This method provides excellent venting for normal operation. This method also provides natural draft in the event of a power failure. If the chimney condition is questionable"you --- may want to install a liner as in method#7. *The chimney should be inspected and cleaned before installing your stove. If you discoverthat the chimney does not have a clay tile liner or has cracks or flaking of the tile liner you will need to install a stainless steel liner within the chimney. In most cases the inside diameter of this liner should be 4". Either flexible or rigid liner may be used for this purpose. Be sure to design the venting so that it can be easily cleaned. THE CHIMNEY MUST BE OF A TYPE SUITABLE FOR SOLID-FUEL BURNING. A WARNING THE CHIMNEY AND CONNECTOR MUST BE V MAINTAINED IN GOOD CONDITION AND KEPT CLEAN. Fig. 10 #4 Installing into an existing fireplace chimney This method provides excellent venting for normal operation. \ This method also provides natural draft in the event of a power failure. If the chimney condition is questionable"you may want to install a liner as in method#6. "The chimney should be inspected and cleaned before \ installing your stove. If you discoverthatthe chimney does not have a clay tile liner or has cracks or flaking of the tile liner you \ will need to install a stainless steel liner within the chimney. In most cases the inside diameter of this liner should be 4". Either flexible or rigid liner may be used for this purpose. - The chimney should be sealed at the damper using a steel plate. Kaowool, mineral wool or an equivalent non- combustible insulation is recommended to be installed on top of the sealing plate to reduce the possibility of condensation. !! The connector pipe should extend through the smoke chamber to the base or into the first flue tile. /I Be sure to design the venting so that it can be easily cleaned. Fig. 11 11 P68 Pellet Stove 3-90-00688R2803/14 a ' Requirements for Terminating the Venting I. The clearance to service regulator vent outlet must be a WARNING: Venting terminals must not be recessed into a minimum of 6 feet. wall or siding. J. The clearance to a non-mechanical air supply inlet to the NOTE: Only PL vent pipe wall pass-throughs and fire stops building or the combustion air inlet to any other appliance should be used when venting through combustible materials. must be a minimum of 48". NOTE: Always take into consideration the effects of the K. The clearance to a mechanical air supply inlet must be a prevailing wind direction or other wind currents that may minimum of 10 feet. (with outside air installed,6 feet) cause flyash and/or smoke when placing the termination vent. L. The clearance above a paved sidewalk or a paved In addition, the following must be observed: driveway located on public property must be a minimum of 7 feet. A. The clearance above grade must be a minimum of 12". M.The clearance under a veranda, porch, deck or balcony B. The clearance to a window or door that may be opened must be a minimum of 12 inches. (See B.) must be a minimum of 48" to the side, 48" below the NOTE: The clearance to vegetation and other exterior window/door, and 12"above the window/door. combustibles such as mulch is 36" as measured from the C. A 12" clearance to a permanently closed window is center of the outlet or cap.This 36"radius continues to grade recommended to prevent condensation on the window. or a minimum of 7 feet below the outlet. D. The vertical clearance to a ventilated soffit located above Certain Canadian and or Local codes or regulations may the terminal within a horizontal distance of 2 feet(60 cm) require different clearances. from the center-line of the terminal must be a minimum A vent shall not terminate directly above a side-walk or of 18". paved driveway which is located between two single family E. The clearance to an unventilated soffit must be a minimum dwellings and serves both dwellings. of 12". Only permitted if veranda, porch, deck, or balcony is fully F. The clearance to an outside corner is 11"from center of open on a minimum of 2 sides beneath the floor. pipe. G. The clearance to an inside corner is 12". NOTE: Where passage through a wall, or partition of H. A vent must not be installed within 3 feet (90 cm) above combustible construction is desired,the installation shall a gas meter/regulator assembly when measured from the conform to CAN/CSA-B365. (if in Canada) horizontal center-line of the regulator. -4 6 D A �� isme coer Detail B ono �C B ed nosed B Porch or Deck ` F B openaMe pied r Open able or Fixed L r Dosed 1. 0 Openable nx C Sidewalk 4 B I-- M A K =Vent Terminal 0 =Air Supply Inlet ® =Area where termination is not permitted 7 P68 Pellet Stove 3-90-00688R2803/14 Installation Installing Alternate floor protector Place the stove on a noncombustible type floor or floor protector dimension may be used that extends a minimum of 6 inches (152mm)to the front of the as long as they satisfy 9,,(228mm)- the measurement load door opening, 6 inches (152mm) to the sides of the door 13"(330mm) requirements shown opening, and 6 inches to the rear. Floor protection must also below. extend 2 inches(51 mm)beyond each side of any horizontal flue Minimum size floor protection for a corner pipe. The minimum floor protector material is 20 gauge sheet installation is 38"x 38°. metal. Other floor protector materials are ceramic tile, stone, Clearance shown as 9" brick, etc. with optional side shields NOTE for Canadian installation only: Per ULC-S627-00, installed. \\� If installed on a combustible floor, the need to provide a 9"(228mm)With Side Shields W N noncombustible floor protector covering the area beneath the 13"(330mm)Without Side Shields o c space heaterand extending at least 17.72"(450mm)on the firing 3 side and at least 7.87" (200mm) on the other sides. Fig.3 In Canada, you may follow smaller U.S. floor protection requirements ONLY if the user agrees to completely shut- down the appliance, and allow it to cool to where all fire is i I extinguished and the combustion blower and its indicator 2"(51 mm) light shuts off,prior to opening the firebox door or ash door. r Place the stove away from combustible walls at least as far as 14"(355mm)with shown in Figures 3 and 4. Please note the difference in side wall side shields clearance with and without side shields. ° ------- 14"(355mm) 508mm Note that the clearances shown are minimum for safety but do not 20"( ) I 20°(508mm) shields leave much room for access when cleaning or servicing. Please without side take this into account when placing the stove � Connect the power cord to a 120 VAC.60Hz grounded receptacle. J (A surge protector is recommended to protect the circuit board.) Also be sure that the polarity of the outlet that the stove is plugged into is correct. 36"(914mm) Prior to installing the flue pipe, connect a draft meter. (The Fig.4 -- draft meter must have a minimum range of 0 - .5") Record the Minimum size rectangular floor protection (USA) is 33" first reading. Connect flue pipe to stove and be sure all doors Deep By 25"Wide. and windows in the home are closed. Record the second draft reading . If the second reading is more than .05" lower Floor protection dimensions for the front and sides than the first reading, check for possible restrictions or the need are measured from the appliance door opening in for outside air(see page 10). For more information on the draft The United States. In Canada, the side dimension is test procedure, refer to Page 21. measured from the widest part of the appliance. Mobile Home Installation When installing this unit in a mobile home, several requirements FkN must be followed: i an 1.The unit must be bolted to the floor.This can be done with 1/4' lag screws through the 2 holes in the base plate. Sides 6" 200mm 2.The unit must also be connected to outside air. See page 10. - 3. Floor protection and clearances must be followed as shown. K Front 6" 450mm 4. Unit must be grounded to the metal frame of the mobile home. -- - - -- - - ---� - - 5. Be sure to follow the vent manufacturer's guidelines to provide L Rear 6" 200mm for a sufficient vapor barrier where the flue penetrates the outside. NOTE: 6.The top section of any chimney or venting must be removable Measurement"L" to a height of 13' (3.9 M)to allow for transport. is measured from 7. The factory-built chimney must conform to CAN/ULC-S629, the pedestal base Standard for 650°C Factory-Built Chimneys. in the US ONLY L CAUTION: This appliance must be vented to the outside. Clothing and other flammable materials should not be placed on or near this unit. NOTE: Measurement"K" A WARNING t measured from the glass in the US ONLY THE STRUCTURAL INTEGRITY OF THE MANUFACTURED CANADA HOME FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED. ______ K USA ' � FLOOR PROTECTOR DO NOT INSTALL IN SLEEPING ROOM. J 3-90-00688R2803/14 P68 Pellet Stove 6 City of Northampton Massachusetts '� �r 4` $ARTMENT OF BUILDING INSPECTIONS 2014 1 !Q•32 Main Street • Municipal Building 4) �b .� Northampton, MA 01060 �b Electric, Plumbing&Ga nspections Northampton. MA 01060 SINGLE OR TWO FAMILY SOLID FUEL APPLIANCE PERMIT APPLICATION FOR WOOD, COAL, PELLET, CORN, STRAW OR SIMILAR STOVE22S, OR FIREPLACE INSERTS Permit Fee: $25.00 Check # d✓ PLEASE TYPE OR PRINT ALL INFORMATION n 1. Name of Applicant: �0 U4�it S L �{��jcc . .6-e1-"f Q 57 r;Q 't_3 ` V�,J, ,�r° na rn 5 Y an n'►i i 3 a S Addres . _ _ Telephone: '`�..� 7r 2. Owner of Property: —_/QV/� k S jO / Address: 5-6- �i7zS'/�'9'�1<� '�D. ,Ct;'�-S Telephone: 5//-8 3. Status of Applicant: Owner Contractor 4. Type or Brand of Stove:. 1//Id�rr Fl1✓ `�f `" 'f 1r - 'eC'm aft 11 a�� &JOP� 5'TnV� '900 in_j in'�c� ISflA7 ,rY,a '�on ry cdtr rnr1Ty, If applicant is not the homeowner: Construction Supervisor's License Number 9701 Expiration Date Home Improvement Contractor Registration Number Expiration Date All Applicants must complete a Workers Compensation Insurance Affidavit before we can issue a permit 5. Certification: I hereby certify that the information contained herein is true and accurate to the best of my knowle ge. DATE: 'Y APPLICANT'S SIGNATURE v DATE: q / L HOMEOWNER'S SIGNATURE C APPROVED DATE: BUILDING OFFICIAL 55 CHESTERFIELD RD BP-2014-1116 GIS#: COMMONWEALTH OF MASSACHUSETTS Man.Block: 16A-019 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: woodstove BUILDING PERMIT Permit# BP-2014-1116 Project# JS-2014-001896 Est. Cost: Fee: $25.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: BERNARDSTON FARMERS SUPPLY 99401 Lot Size(sq. ft.): 31014.72 Owner: K1SLO PAUL M&BARBARA A Zoning: URA(100)/ Applicant. BERNARDSTON FARMERS SUPPLY AT. 55 CHESTERFIELD RD Applicant Address: Phone: Insurance: 43 RIVER ST (413) 648-9311 () WC BERNARDSTONMA01337 ISSUED ON:412512014 0:00:00 TO PERFORM THE FOLLOWING WORK.-INSTALL HARMAN P68 PELLET STOVE IN EXISTING MASONRY CHIMNEY POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 4/25/2014 0:00:00 $25.00 212 Main Street, Phone(413)587-1240, Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner