Loading...
31A-311 (4) C / 2-2514 2:41 m 1 of l KeyBeam®4.600d kmBeamEngine 4.6026 Materials Database 1472 Member Data Description: Member Type: Beam Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC1IRC Live Load: 40 PLF Deflection Criteria: L/360 live, U240 total 1.250" max. LL Dead Load: 10 PLF Deck Connection: Nailed Member Weight: 9.4 PLF Filename: KYB1 Other Loads Type Trib. Other Dead (Description) Side Begin End Width Start End Start End Category Replacement Tapered PLF Top 0' 0.00" 10' 8.00" 35 17 455 221 Snow 10 8 0 O � 10 8 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 2259# -- 2 10' 8.000" Wall N/A N/A 1.500" 1779# - Maximum Load Case Reactions Used for applying point loads(or line loads)to carrying members Snow Dead 1 158# 2101# 2 123# 1655# Design spans 10' 9.750" Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Connect members with 2 rows of 16d common nails at 12.0"oc Minimum 1.50"bearing required at bearing#1 Minimum 1.50"bearing required at bearing#2 Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 5084.'# 12562.'# 40% 4.79' Total Load D Shear 17331 5686.# 30% -0.06' Total Load D TL Deflection 0.2296" 0.5406" U565 5.32' Total Load D+S LL Deflection 0.0160" 0.3604" U999+ 5.32' Total Load S Control: TL Deflection DOLs: Live=100% Snow--115% Roof=125% Wind=160% All product names are trademarks of their respective owners Copyright(C)2013 by Simpson Strong-Tie Company Inc.ALL RIGHTS RESERVED. "Passing is defined as when the member,floor joist,beam or girder,shown on this tlrawing meets applicable tlesign criteria for Loads.Loading Conditions,antl Spans listed on this she The tlesi n must be reviewed b a ualified desi ner or desi n rofessio,at as re uired fora royal.This des/n assumes roduct instaCation accordin to the manufacturer's s ecifications.