Loading...
Zucker Abel A-002permitJOB NO. DATE SCALE DRAWINGTITLE REVISIONS PROJ.2013-34 12-19-13 1/4"=1'-0" CA L L NO R T H PROJECT M U N K I T T R I C K A S S O C I A T E S A R C H I T E C T U R E I N T E R I O R D E S I G N S P A C E P L A N N I N G P . O . B O X 1 6 7 C O B A L T , C T 0 6 4 1 4 m u n k i t t r i c k a s s o c i a t e s @ g m a i l . c o m ZUCKER-ABEL HOUSE RENOVATION 47 DRYADS GREEN NORTHAMPTON, MASSACHUSETTS 1 02-04-14 REMOVE MASONRY CHIMNEY & MISC. ISSUED FOR PERMIT. UP BEDROOM 3 BATH BEDROOM 1 BEDROOM 2 MASTER BATH STAIRHALL SPARE ROOM SECOND FLOOR PLAN A-002 WALK-IN CLOSET EXPANDED CLOSET NEW 36" X 66" TILED C.I. TUB & SHOWER NEW WC EXPAND LINEN CLOSET WALK-IN CLOSET POCKET DOOR NEW 52" VANITY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 CONSTRUCTION KEY EXISTING TO REMAIN EXISTING TO BE REMOVED NEW CONSTRUCTION CONSTRUCTION FLOOR PLAN SCALE: 1/4" = 1'-0" 1 1 1 1 1 1 1 1 1 1 2 7 7 12 12 12 13 13 13 C 4 MARVIN ULTIMATE WOOD SINGLE CASEMENT WINDOW __________ (R.O. = ________________). PAINTED WOOD EXTERIOR/INTERIOR COMPLETE W/ INSECT SCREEN & HARDWARE: _________________ MARVIN ULTIMATE WOOD FRENCH CASEMENT WINDOW: WUFCA4848 (R.O. = 4'-1" X 4'-0 9/16") COMPLETE W/ INSECT SCREEN & HARDWARE: _________________ MARVIN ULTIMATE WOOD FIXED AWNING WINDOW: WUAWN4824 (R.O. = 4'-1" X 2'-0 9/16") USED AT INTERIOR WALL. 3470 5-PANEL WOOD DOOR TO MATCH EXISTING MFR: HARDWARE: 5070 PAIR OF 5-PANEL DOORS TO MATCH EXISTING MFR: HARDWARE: 2670 POCKETING 5-PANEL DOOR TO MATCH EXISTING MFR: HARDWARE: WINDOWS & DOORS NOTES & SPECIFICATIONS 1. ALL WINDOWS AND DOORS TO HAVE INTERIOR AND EXTERIOR CASINGS AND TRIM TO MATCH HOUSE TYPES IN ALL DETAILS. 2. HEADER HEIGHTS PER DESIGN INTENT (SEE WALL ELEVATIONS). HEADER SIZES AS REQUIRED. 3. ALL WINDOW & DOOR GLAZING TO BE: LOW-E DOUBLE INSULATED W/ TRUE DIVIDED LIGHTS. 4. VERIFY ALL ROUGH OPENINGS WITH MANUFACTURER. JAMB EXTENSIONS AS REQUIRED. 4 5 5 5 6 5 6 4 1 6'-0" ALIGN SH E L V E S HA N G R O D & S H E L F HA N G R O D & S H E L F D NEW 32 X 60" TILED C.I. TUB & SHOWER D NEW PEDESTAL SINK NEW WC 15 2 X 3 FRAMING STO. CAB. MAINTAIN EXISTING ATTIC ACCESS 12 BASE CABS. & BOOK SHELVES 2A 2B MIN. ENCLOSURE OF EXIST'G BRICK 5 5 5 5 16 WINDOW ABOVE E E NEW PEDESTAL SINK 1 UP BEDROOM 3 BATH EXISTING CLOSET 7 7 7 7 7 7 1 1 1 1 1 2 13 13 13 2 4 4 4 6 6 14 13 13 4 3 1 4 4 BEDROOM 1 BEDROOM 2 STAIRHALL SPARE ROOM 1 CONSTRUCTION PLAN GENERAL NOTES: 1. WHERE ANY EXTERIOR WALL OR ROOF CAVITY IS OPENED, RE-INSULATE WALL/ROOF CAVITY WITH NEW FIBERGLASS BATT INSULATION TO MAXIMUM R-VALUE ACHIEVABLE. SPRAY-FOAM INSULATION ACCEPTABLE ONLY AFTER SPECIFICATIONS ARE SUBMITTED FOR APPROVAL BY MUNKITTRICK ASSOCIATES & THE OWNER. 2. REFINISH ALL EXISTING AND NEW HARDWOOD FLOORING THROUGHOUT WITH MINIMUM 2 COATS SATIN POLYURETHANE. SAMPLE TO BE APPROVED. (3 COATS AT KITCHEN). 3. REMOVE ALL WALL AND FLOOR GRILLES AND REGISTERS. PATCH BASEBOARDS AND WALLS TO MATCH ADJACENT FINISHES. 4. ALL CEILINGS THROUGHOUT ARE TO BE REPAIRED WHERE CRACKED, LOOSE PLASTER RE-ADHERED, AND FINISHED SMOOTH. ALL EXISTING CEILINGS THAT ARE NOT FINISHED SMOOTH ARE TO BE RE-PLASTERED FOR SMOOTH FINISH, SANDED AND PRIMED READY FOR PAINT. 5. SEE ROOM FINISH SCHEDULE FOR RELATED WORK SCOPE. 6. ALL EXISTING WINDOWS TO BE REFURBISHED WITH NEW ROPE SASH , LOCKING HARDWARE (OWNER TO APPROVE), GLAZING AND RESTORATION THROUGHOUT WHEREVER REQUIRED FOR SMOOTH OPERATION OF SASH AND HARDWARE. NEW WOOD FRAME CONSTRUCTION TO MATCH OUT FINISHES WITH EXISTING ADJACENT WALLS, INTERIOR AND EXTERIOR. (AT EXTERIOR WALLS, INSULATE CAVITY FULLY.) BASEBOARD AND CEILING MOLDINGS (WHERE TO REMAIN) TO MATCH EXISTING. NEW WOOD FRAME CONSTRUCTION: 2 X 4 @ MAX. 16" OC WITH MIN. 1/2" GYPSUM SHEET ROCK BOTH SIDES, TAPED AND SANDED SMOOTH READY TO RECEIVE PAINT OR PAPER. BASEBOARD AND CEILING MOLDINGS (WHERE TO REMAIN) TO MATCH EXISTING (U.O.N.) NEW WOOD CONSTRUCTION AS REQUIRED FOR MECHANICAL CHASE. FINISH WITH MIN. 1/2" GYPSUM SHEET ROCK ALL SIDES, TAPED AND SANDED SMOOTH READY TO RECEIVE PAINT OR PAPER. BASEBOARD AND CEILING MOLDINGS TO MATCH EXISTING. NEW BEAM HEADER REQUIRED (ASSUMED): DOUBLE 2 X 12 ON MIN. 4 X 4 POST BEARING. ADD LALLY COLUMN SUPPORTS IN BASEMENT BELOW ON 24" X 24" X 12" DEEP MINIMUM CONCRETE FOOTINGS WHERE REQUIRED. (NOTE: LOCATE HEADER BEAMS FOR NEW FINISH OPENING HEIGHTS PER WALL ELEVATIONS). WEAVE IN NEW HARDWOOD FLOORING TO MATCH EXISTING THROUGHOUT AREA INDICATED. (NEW SUBFLOORING WHERE REQUIRED FOR LEVEL ELEVATIONS THROUGHOUT). NEW STAIR RISER AND TREAD TO MATCH EXISTING (AT NORTH SIDE DETAIL). REFINISH EXISTING TREADS AND WOOD CAP AT HALF WALL TO MATCH HARDWOOD FLOORS (PAINTED RISERS). NEW RISERS AND TREADS TO MATCH MAIN STAIRS IN FINISH AND DETAILS. NEW BASEMENT STAIRS DOWN TO MATCH EXISTING . REFURBISH/RESTORE EXISTING POCKETING DOORS FOR SMOOTH OPERATION. NEW KITCHEN CABINETRY: AND COUNTERTOPS: SUPPLIED AND INSTALLED BY OWNER'S VENDOR. GENERAL CONTRACTOR FOR HOUSE RENOVATION TO COORDINATE ALL RELATED WORK WITH OWNER'S VENDOR/INSTALLER. OWNER WILL BE SUPPLYING ALL KITCHEN APPLIANCES INCLUDING REFRIGERATOR, DUAL FUEL RANGE, EXHAUST HOOD, DISHWASHER, SINK DISPOSER. GENERAL CONTRACTOR FOR HOUSE RENOVATION TO PROVIDE ALL MECHANICAL, ELECTRICAL, AND PLUMBING ROUGH INS AND FINAL HOOK-UPS, INCLUDING RELOCATED GAS SERVICE, DUCTOWRK FOR HOOD EXHAUSE TO EXTERIOR WALL CAP, WATER LINE FOR REFRIGERATOR, SHUT OFF VALVES, AND ALL ELECTRICAL CONNECTIONS FOR A COMPLETE INSTALLATION FOR ALL APPLIANCES PER MANUFACTURER'S INSTRUCTIONS. GENERAL CON- TRACTOR FOR HOUSE RENOVATION TO SUPPLY AND INSTALL KITCHEN SINK AND FAUCET SET AS SCHEDULED, COORDINATING HIS WORK WITH THAT OF THE COUNTERTOP INSTALLATION. SUPPLY AND INSTALL ALL BUILT-IN CASEWORK AND BOOK CASES. PROVIDE SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION. SEE ROOM FINISH SCHEDULE AND NOTES FOR FINISH INFORMATION. REUSE SALVAGED DOOR, FRAME, CASINGS & HARDWARE (WHERE FEASIBLE). REFURBISH TO LIKE-NEW CONDITION AND PREPARE READY FOR FINISHES. (SEE FINISH SCHEDULE & NOTES). RE-SIDE WITH CLAPBOARD AND TRIM TO MATCH EXISTING ONE-STORY ADDITION (AT LIVING ROOM). RE-SIDE WITH CLAPBOARDS, SHAKES AND TRIM TO MATCH EXISTING WALLS. REMOVE HANDRAIL AT SOUTH SIDE OF STAIRS DOWN. PATCH TO MATCH. REFINISH EXISTING HANDRAIL AT NORTH SIDE OF STAIRS DOWN. STAIN & SEAL (COLOR & FINISH TO BE APPROVED). REPAIR & REFINISH BALUSTRADE COMPONENTS. STAIN & SEAL (COLOR & FINISH TO BE APPROVED). 1 2 3 4 5 6 7 8 9 10 11 12 13 DEMOLITION PLAN GENERAL NOTES: 1. ALL REMOVED ITEMS TO BE DISPOSED OFF SITE PER CODES AND TOWN ORDINANCE REQUIREMENTS. 2. OWNER TO COORDINATE ANY SALVAGE REQUIREMENTS DIRECTLY WITH CONTRACTOR. REMOVE EXISTING (ASSUMED) NON-LOAD BEARING WALL FROM FLOOR TO CEILING. PATCH ADJACENT WALLS, CEILING AND FLOOR TO MATCH EXISTING. REMOVE ALL MECHANICAL AND ELECTRICAL BACK TO NEAREST CONCEALED JUNCTION LOCATIONS AS REQUIRED. COORDINATE REMOVALS WITH ALL NEW CONSTRUCTION AND FINAL FINISH WORK. REMOVE EXISTING (ASSMED) LOAD-BEARING WALL FROM FLOOR TO CEILING. PATCH ADJACENT WALLS, CEILING AND FLOOR TO MATCH EXISTING. REMOVE ALL MECHANICAL AND ELECTRICAL BACK TO NEAREST CONCEALED JUNCTION LOCATIONS AS REQUIRED. COORDINATE REMOVALS WITH ALL NEW CONSTRUCTION AND FINAL FINISH WORK. SEE CONSTRUCTION PLAN THIS SHEET FOR HEADER BEAM REQUIREMENTS. REMOVE EXTERIOR WALL SECTION, INCLUDING WINDOWS AND DOORS, AND RE-FRAME NEW WALL OPENING READY TO RECEIVE NEW WINDOWS AND DOORS (INCLUDING FILL CONSTRUCTION TO MATCH EXISTING WHERE REQUIRED). REMOVE ALL MECHANICAL AND ELECTRICAL BACK TO NEAREST CONCEALED JUNCTION LOCATIONS AS REQUIRED. COORDINATE REMOVALS WITH ALL NEW CONSTRUCTION AND FINAL FINISH WORK. INSTALL NEW HEADER BEAMS AS REQUIRED. SEE CONSTRUCTION PLAN THIS SHEET FOR NEW WINDOW AND DOOR OPENINGS. REMOVE DOOR, FRAME AND THRESHOLD. PREPARE OPENING AS REQUIRED TO RECEIVE NEW DOOR OR BLOCK OPENING WITH NEW CONSTRUCTION TO MATCH EXISTING. SALVAGE DOORS FOR REUSE PER CONSTRUCTION PLAN THIS SHEET. REMOVE EXISTING KITCHEN APPLIANCE, CABINETRY, WAINSCOTTING AND COUNTERTOPS COMPLETE. PATCH ADJACENT WALLS, CEILING AND FLOOR TO MATCH EXISTING. REMOVE ALL MECHANICAL AND ELECTRICAL BACK TO NEAREST CONCEALED JUNCTION LOCATIONS AS REQUIRED. REMOVE BATHROOM COMPLETE. PATCH ADJACENT WALLS, CEILING AND FLOOR TO MATCH EXISTING. REMOVE ALL MECHANICAL AND ELECTRICAL BACK TO NEAREST CONCEALED JUNCTION LOCATIONS AS REQUIRED. REMOVE EXISTING STEAM RADIATION & ELECTRICAL BASEBOARD SYSTEMS IN THEIR ENTIRETY, INCLUDING CAST IRON RADIATORS, BASEBOARD, PIPING & CONTROLS. PATCH ADJACENT WALLS, CEILING AND FLOOR TO MATCH EXISTING. SEE MECHANICAL PLAN FOR NEW SYSTEM SCHEMATIC. REMOVE EXISTING STAIR TREAD AND RISER ASSEMBLY. INSTALL NEW STAIR TREAD AND RISER ASSEMBLY TO MATCH EXISTING DETAILS WITH LEFT SIDE HALF-ROUND RETURN (TO MATCH RIGHT SIDE). SEE CONSTRUCTION NOTE #6. REMOVE EXISTING WALL PANELING (AND ASSUMED DRYWALL SUBSTRATE) COMPLETE. REMOVE EXISTING WOOD STOVE THRU-WALL THIMBLE ASSEMBLY. INSULATE AND BLOCK WALL WITH ALL MATERIALS TO MATCH EXISTING. REMOVE EXISTING GAS SUPPLY FEED AT FLOOR. TERMINATE BELOW FLOOR AS REQUIRED. REMOVE EXISTING WOOD DECK DOWN TO STRUCTURAL SUPPORTS TO BE REUSED IN EXPANDED & RECONSTRUCTED DESK. (SEE CONSTRUCTION PLAN THIS SHEET FOR PLAN OF EXPANDED DECK). SEE CONSTRUCTION NOTE #17. REMOVE EXISTING DECK COMPLETE, INCLUDING STRUCTURAL SUPPORTS AND GROUND PIER FOUNDATIONS. REMOVE EXISTING SHELVING OR CABINETRY. PATCH ADJACENT WALLS, CEILING AND FLOOR TO MATCH EXISTING. REMOVE EXISTING DECKS AND STEPS. PATCH ROOF, REPLACE GUTTERS, AND ALL SIDEWALL TRIM AND SIDING TO MATCH EXISTING. DEMOLISH EXISTING MASONRY CHIMNEY COMPLETE TO BASEMENT STRUCTURAL. DEMOLITION FLOOR PLAN SCALE: 1/4" = 1'-0" 14 SPARE ROOM 2 1 15 15 1