02-027 (5) e
INSTALLATION
VENT TERMINATION REQUIREMENTS:
IT IS RECOMMENDED THAT YOUR PELLET STOVE BE INSTALLED BY AN AUTHORIZED DEALER/INSTALLER.
Table 2: Use in conjunction with Figure 6 for allowable exterior vent termination locations.
Letter Minimum Clearance Description
A 24 in (61 cm) Above grass,top of plants,wood, or any other combustible materials.
B 48 in (122 cm) Beside/below any door or window that may be opened. (18"(46 cm) if outside
fresh air installed.)
C 12 in (30 cm) Above any door or window that may be opened. (9"(23 cm) if outside fresh air
installed.)
D j 24 in (61 cm) To any adjacent building,fences and protruding parts of the structure.
E 24 in (61 cm) Below any eave or roof overhang
F 12 in (30 cm) To outside corner.
G 12 in (30 cm) To inside corner, combustible wall (vertical and horizontal terminations).
H 3 ft(91 cm)within a height To each side of center line extended above natural gas or propane meter/
of 15 ft(4.5 m) above the regulator assembly or mechanical vent.
meter/regulator assembly
I 3 ft(91 cm) From any forced air intake of other appliance
J 12 in (30 cm) Clearance to non-mechanical air supply inlet to building,or the combustion air
inlet to any appliance.
K 24 in (61 cm) Clearance above roof line for vertical terminations.
L 7 ft(2.13 m) Clearance above paved sidewalk or paved driveway located on public property.
1. Do not terminate the
vent in any enclosed or K
semi-enclosed areas such
as a carport, garage,
attic, crawlspace, narrow E
walkway, closely fenced p opens C G
area, under a sundeck F
Opens
or porch, or any location g I Opens L
that can build up a A
concentration of fumes ®Termination Cap H such as stairwells, covered ® Air Supply Inlet Gas Meter Restriction o?onree
breezeway, etc. Figure 6: Use in conjunction with Table 2 for allowable exterior vent termination
locations.
2. Vent surfaces can become hot enough to cause burns if touched by children. Non-combustible shielding or
guards may be required.
3. Termination must exhaust above the inlet elevation. It is recommended that at least five feet of vertical pipe be
installed outside when the appliance is vented directly through a wall,to create some natural draft to prevent the
possibility of smoke or odor during appliance shut down or power failure. This will keep exhaust from causing a
nuisance or hazard from exposing people or shrubs to high temperatures. In any case,the safest and preferred
venting method is to extend the vent through the roof vertically.
4. Distance from the bottom of the termination and grade is 12" (30 cm) minimum. This is conditional upon the
plants and nature of grade surface.The exhaust gases are hot enough to ignite grass, plants and shrubs located
in the vicinity of termination. The grade surface must not be lawn.
5. If the unit is incorrectly vented or the air to fuel mixture is out of balance, a slight discoloration of the exterior
of the house might occur. Since these factors are beyond the control of Sherwood Industries Ltd, we grant no
guarantee against such incidents.
16 NOTE: Venting terminals shall not be recessed into walls or siding.
INSTALLATION
CLEARANCES TO COMBUSTIBLES:
Back Wall
s°(7.scmr -9- These dimensions are minimum clearances but it
+ is recommended that you ensure sufficient room
f d for servicing, routine cleaning and maintenance.
(7.6cm)
Side wall to unit 9 inches (22.9 cm)
Back wall to unit 3 inches (76 cm)
-- __ Corner to unit 3 inches (76 cm)
� i ��� Cei
9.. ling height 60 inches (152 cm)
a (22.9cm) II
i Alcove Maximum Depth 36 inches (91 cm)
- J Alcove Minimum Width 48 inches (122 cm)
- Alcove Minimum Height 60 inches (152 cm)
The unit must be installed with a minimum of 6"
Figure 4: M-55C-FS Clearance to Combustibles. (152 mm) of floor protection in front of and to
the sides of the door opening.
LEVELING LEG ADJUSTMENT:
The leveling legs should be adjusted for the unit to to sit level and not rock if installed on uneven flooring.
1. Turn levelling legs until they are at the required hieghts.
2. Tighten the nut to hold the leveling leg in position.
THERMOSTAT INSTALLATION:
1. Install the wall thermostat (millivolt rated thermostat
recommended, or a 12/24 Volt rated thermostat set to
g millivolts) in a location that is not to close too the unit
but will effectively heat the desired area.
2. Connect the Thermostat using a 2 x 18 gauge wire
Remove;umper from the unit to the thermostat.
wire and install °
thermostat wires here.
If the heat in the room becomes to great, the high limit
switch may turn the stove off and the switch will have to
be manually reset. The switch is found below the firebox
top on the hopper's right surface.
Figure 5:Thermostat wire placement.
15
SPECIFICATIONS
DIMENSIONS:
23''
(584mm)
30"
(764mm)
30'
291/z' (765mm)
(750mm) 273/4`
(703mm)
32'/<"
(819mm)
war
2
p24m amm) X431 7 mm)
Figure 1: Dimensions of M-55C-FS.
SPECIFICATIONS:
Input rating when using: Wood Pellets/Corn - 55,000BTU (16.1KWhr) &Wheat/Barley- 53,000BTU (15.5KWhr).
Table 1: M-55C-FS Specifications.
Description Fuel type
Residential Pellet Heater 6mm (1/4'� dia. Pellets - wood, corn, wheat, & barley*
Voltage Current Max Power
110 - 120 V 4.2 Amps 504 Watts
Frequency Hopper Capacity Consumption on Low
60 Hz up to 60 lb (36.3 Kg) 1.5 lb/hr (0.68 Kg/hr)*
Testing Standard Weight (with full hopper) Consumption on High
ASTM 1509-04 485 lb (220 Kg) 6.5 lb/hr (2.95 Kg/hr)*
*Note: Consumption will vary with the type of fuel used.
6
The Commonwealth of Massachusetts
Department of Industrial Accidents
Office of Investigations
a I Congress Street, Suite 100
Boston, MA 02114-2017
www.mass.gov/dia
Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers
Applicant Information Please Print Legibly
Name (Business/Organization/Individual): BERNARDSTON FARMERS SUPPLY
Address:43 RIVER STREET
City/State/Zip: BERNARDSTON, MA 01337 Phone #:413-648-9311
Are you an employer? Check the appropriate box: Type of project(required):
1. 1 am a employer with 10 4. ❑ I am a general contractor and I
employees (full and/or part-time).* have hired the sub-contractors 6. New construction
2.❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling
ship and have no employees These sub-contractors have g. ❑ Demolition
working for me in any capacity. employees and have workers' q ❑ Building addition
[No workers' comp. insurance comp. insurance.$
required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions
3.❑ I am a homeowner doing all work officers have exercised their 1 I.E] Plumbing repairs or additions
myself. [No workers' comp. right of exemption per MGL 12 ❑ Roof repairs
insurance required.] c. 152, §1(4), and we have no
employees. [No workers' 13.❑ Other
comp. insurance required.]
*Anti applicant that checks box 41 must also fill out the section below showing their workers' compensation policy information.
I lomeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new atffidavit indicating such.
k'ontractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have
employees. II'the sub-contractors have employees. they must provide their workers'comp.policy number.
I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site
information.
Insurance Company Name: PEERLESS INSURANCE
Policy #or Self-ins. Lic. #:WC8165644 Expiration Date:7-1-2014
Job Site Address: /,. G -�o1'4)A Ffcr, S h>� City/State/Zip: 1o/rnce lnt 0106 a
Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date).
Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a
tine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine
of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of
Investigations of the DIA for insurance coverage verification.
I do herebv certif�under the pains ai4lpenalties of perjury that the information provided above is true and correct.
Si,,rnature: 6 Date:
Phone #:
Official use only. Do not write in this area, to be completed by city or town official.
City or Town: Permit/License #
Issuing Authority (circle one):
1. Board of Health 2. Building Department 3. City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector
6. Other
Contact Person: Phone#:
C ,� of Northampton
Massachusetts
A FEB e
. 201 DEP NT OF BUILDING INSPECTIONS
i b�
L x21L Man Street * Municipal Building
leetric, Fiu J Northampton, MA 01060
t ����ctions
000
SINGLE OR TWO FAMILY SOLID FUEL APPLIANCE PERMIT APPLICATION
FOR WOOD, COAL, PELLET, CORN, STRAW OR SIMILAR STOVES, OR FIREPLACE INSERTS
Permit Fee: $25.00 Check # 0 3 A D
PLEASE TYPE OR PRINT ALL INFO>RMATIO/N
1. Name of Applicant: cLc
Address: /0C :5'�ar V-:)-- L)J a If jv Telephone: %�' 6
2. Owner of Property:
Address: 6'YJ W0r-T1-' r-ty S�n rl qrc-Y1ne- Telephoner
J/06 r3
3. Status of Applicant: Owner contractor
4. Type or Brand of Stove: Z�jv/-/o M '55 j�j ���f J 1 d V C- /A31 Ai IC i�
y �j> c-r V E-.rr S Ik,,t-(C
If applicant is not the homeowner:
Construction Supervisor's License Number ��� O j Expiration Date
Home Improvement Contractor Registration Number /6 G'/5 Expiration Date
All Applicants must complete a Workers Compensation Insurance Affidavit before we can issue a permit
5. Certification: I hereby certify that the information contained herein is true and accurate to the best
of my knowledge.,)
DATE: 3�" �`� APPLICANT'S SIGNATURE
DATE: HOMEOWNER'S SIGNATURE
APPROVED
DATE: BUILDING OFFICIAL
680 NORTH FARMS RD BP-2014-0863
GIs#: COMMONWEALTH OF MASSACHUSETTS
Map:Block: 02-027 CITY OF NORTHAMPTON
Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
Category: woodstove BUILDING PERMIT
Permit# BP-2014-0863
Project# JS-2014-001513
Est. Cost:
Fee: $25.00 PERMISSION IS HEREBY GRANTED TO:
Const. Class: Contractor: License:
Use Group: BERNARDSTON FARMERS SUPPLY 99401
Lot Size(sq. ft.): 331099.56 Owner: WILMERDING ELIZA
Zoning RR(100)/WSP(100)/WP(47)/ Applicant: BERNARDSTON FARMERS SUPPLY
AT. 680 NORTH FARMS RD
Applicant Address: Phone: Insurance:
43 RIVER ST (413) 648-9311 () WC
BERNARDSTONMA01337 ISSUED ON:211012014 0:00:00
TO PERFORM THE FOLLOWING WORK.-INSTALL ENVIRO M55 F/S PELLET STOVE
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter:
Footings:
Rough: Rough: House# Foundation:
Driveway Final:
Final: Final:
Rough Frame:
Gas: Fire Department Fireplace/Chimney:
Rough: Oil: Insulation:
Final: Smoke: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Certificate of Occupancy Signature:
FeeType• Date Paid: Amount:
Building 2/10/2014 0:00:00 $25.00
212 Main Street,Phone(413)587-1240,Fax: (413)587-1272
Louis Hasbrouck—Building Commissioner