02-027 (5) e INSTALLATION VENT TERMINATION REQUIREMENTS: IT IS RECOMMENDED THAT YOUR PELLET STOVE BE INSTALLED BY AN AUTHORIZED DEALER/INSTALLER. Table 2: Use in conjunction with Figure 6 for allowable exterior vent termination locations. Letter Minimum Clearance Description A 24 in (61 cm) Above grass,top of plants,wood, or any other combustible materials. B 48 in (122 cm) Beside/below any door or window that may be opened. (18"(46 cm) if outside fresh air installed.) C 12 in (30 cm) Above any door or window that may be opened. (9"(23 cm) if outside fresh air installed.) D j 24 in (61 cm) To any adjacent building,fences and protruding parts of the structure. E 24 in (61 cm) Below any eave or roof overhang F 12 in (30 cm) To outside corner. G 12 in (30 cm) To inside corner, combustible wall (vertical and horizontal terminations). H 3 ft(91 cm)within a height To each side of center line extended above natural gas or propane meter/ of 15 ft(4.5 m) above the regulator assembly or mechanical vent. meter/regulator assembly I 3 ft(91 cm) From any forced air intake of other appliance J 12 in (30 cm) Clearance to non-mechanical air supply inlet to building,or the combustion air inlet to any appliance. K 24 in (61 cm) Clearance above roof line for vertical terminations. L 7 ft(2.13 m) Clearance above paved sidewalk or paved driveway located on public property. 1. Do not terminate the vent in any enclosed or K semi-enclosed areas such as a carport, garage, attic, crawlspace, narrow E walkway, closely fenced p opens C G area, under a sundeck F Opens or porch, or any location g I Opens L that can build up a A concentration of fumes ®Termination Cap H such as stairwells, covered ® Air Supply Inlet Gas Meter Restriction o?onree breezeway, etc. Figure 6: Use in conjunction with Table 2 for allowable exterior vent termination locations. 2. Vent surfaces can become hot enough to cause burns if touched by children. Non-combustible shielding or guards may be required. 3. Termination must exhaust above the inlet elevation. It is recommended that at least five feet of vertical pipe be installed outside when the appliance is vented directly through a wall,to create some natural draft to prevent the possibility of smoke or odor during appliance shut down or power failure. This will keep exhaust from causing a nuisance or hazard from exposing people or shrubs to high temperatures. In any case,the safest and preferred venting method is to extend the vent through the roof vertically. 4. Distance from the bottom of the termination and grade is 12" (30 cm) minimum. This is conditional upon the plants and nature of grade surface.The exhaust gases are hot enough to ignite grass, plants and shrubs located in the vicinity of termination. The grade surface must not be lawn. 5. If the unit is incorrectly vented or the air to fuel mixture is out of balance, a slight discoloration of the exterior of the house might occur. Since these factors are beyond the control of Sherwood Industries Ltd, we grant no guarantee against such incidents. 16 NOTE: Venting terminals shall not be recessed into walls or siding. INSTALLATION CLEARANCES TO COMBUSTIBLES: Back Wall s°(7.scmr -9- These dimensions are minimum clearances but it + is recommended that you ensure sufficient room f d for servicing, routine cleaning and maintenance. (7.6cm) Side wall to unit 9 inches (22.9 cm) Back wall to unit 3 inches (76 cm) -- __ Corner to unit 3 inches (76 cm) � i ��� Cei 9.. ling height 60 inches (152 cm) a (22.9cm) II i Alcove Maximum Depth 36 inches (91 cm) - J Alcove Minimum Width 48 inches (122 cm) - Alcove Minimum Height 60 inches (152 cm) The unit must be installed with a minimum of 6" Figure 4: M-55C-FS Clearance to Combustibles. (152 mm) of floor protection in front of and to the sides of the door opening. LEVELING LEG ADJUSTMENT: The leveling legs should be adjusted for the unit to to sit level and not rock if installed on uneven flooring. 1. Turn levelling legs until they are at the required hieghts. 2. Tighten the nut to hold the leveling leg in position. THERMOSTAT INSTALLATION: 1. Install the wall thermostat (millivolt rated thermostat recommended, or a 12/24 Volt rated thermostat set to g millivolts) in a location that is not to close too the unit but will effectively heat the desired area. 2. Connect the Thermostat using a 2 x 18 gauge wire Remove;umper from the unit to the thermostat. wire and install ° thermostat wires here. If the heat in the room becomes to great, the high limit switch may turn the stove off and the switch will have to be manually reset. The switch is found below the firebox top on the hopper's right surface. Figure 5:Thermostat wire placement. 15 SPECIFICATIONS DIMENSIONS: 23'' (584mm) 30" (764mm) 30' 291/z' (765mm) (750mm) 273/4` (703mm) 32'/<" (819mm) war 2 p24m amm) X431 7 mm) Figure 1: Dimensions of M-55C-FS. SPECIFICATIONS: Input rating when using: Wood Pellets/Corn - 55,000BTU (16.1KWhr) &Wheat/Barley- 53,000BTU (15.5KWhr). Table 1: M-55C-FS Specifications. Description Fuel type Residential Pellet Heater 6mm (1/4'� dia. Pellets - wood, corn, wheat, & barley* Voltage Current Max Power 110 - 120 V 4.2 Amps 504 Watts Frequency Hopper Capacity Consumption on Low 60 Hz up to 60 lb (36.3 Kg) 1.5 lb/hr (0.68 Kg/hr)* Testing Standard Weight (with full hopper) Consumption on High ASTM 1509-04 485 lb (220 Kg) 6.5 lb/hr (2.95 Kg/hr)* *Note: Consumption will vary with the type of fuel used. 6 The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations a I Congress Street, Suite 100 Boston, MA 02114-2017 www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): BERNARDSTON FARMERS SUPPLY Address:43 RIVER STREET City/State/Zip: BERNARDSTON, MA 01337 Phone #:413-648-9311 Are you an employer? Check the appropriate box: Type of project(required): 1. 1 am a employer with 10 4. ❑ I am a general contractor and I employees (full and/or part-time).* have hired the sub-contractors 6. New construction 2.❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have g. ❑ Demolition working for me in any capacity. employees and have workers' q ❑ Building addition [No workers' comp. insurance comp. insurance.$ required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 1 I.E] Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12 ❑ Roof repairs insurance required.] c. 152, §1(4), and we have no employees. [No workers' 13.❑ Other comp. insurance required.] *Anti applicant that checks box 41 must also fill out the section below showing their workers' compensation policy information. I lomeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new atffidavit indicating such. k'ontractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. II'the sub-contractors have employees. they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: PEERLESS INSURANCE Policy #or Self-ins. Lic. #:WC8165644 Expiration Date:7-1-2014 Job Site Address: /,. G -�o1'4)A Ffcr, S h>� City/State/Zip: 1o/rnce lnt 0106 a Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a tine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do herebv certif�under the pains ai4lpenalties of perjury that the information provided above is true and correct. Si,,rnature: 6 Date: Phone #: Official use only. Do not write in this area, to be completed by city or town official. City or Town: Permit/License # Issuing Authority (circle one): 1. Board of Health 2. Building Department 3. City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector 6. Other Contact Person: Phone#: C ,� of Northampton Massachusetts A FEB e . 201 DEP NT OF BUILDING INSPECTIONS i b� L x21L Man Street * Municipal Building leetric, Fiu J Northampton, MA 01060 t ����ctions 000 SINGLE OR TWO FAMILY SOLID FUEL APPLIANCE PERMIT APPLICATION FOR WOOD, COAL, PELLET, CORN, STRAW OR SIMILAR STOVES, OR FIREPLACE INSERTS Permit Fee: $25.00 Check # 0 3 A D PLEASE TYPE OR PRINT ALL INFO>RMATIO/N 1. Name of Applicant: cLc Address: /0C :5'�ar V-:)-- L)J a If jv Telephone: %�' 6 2. Owner of Property: Address: 6'YJ W0r-T1-' r-ty S�n rl qrc-Y1n­e- Telephoner J/06 r3 3. Status of Applicant: Owner contractor 4. Type or Brand of Stove: Z�jv/-/o M '55 j�j ���f J 1 d V C- /A31 Ai IC i� y �j> c-r V E-.rr S Ik,,t-(C If applicant is not the homeowner: Construction Supervisor's License Number ��� O j Expiration Date Home Improvement Contractor Registration Number /6 G'/5 Expiration Date All Applicants must complete a Workers Compensation Insurance Affidavit before we can issue a permit 5. Certification: I hereby certify that the information contained herein is true and accurate to the best of my knowledge.,) DATE: 3�" �`� APPLICANT'S SIGNATURE DATE: HOMEOWNER'S SIGNATURE APPROVED DATE: BUILDING OFFICIAL 680 NORTH FARMS RD BP-2014-0863 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 02-027 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: woodstove BUILDING PERMIT Permit# BP-2014-0863 Project# JS-2014-001513 Est. Cost: Fee: $25.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: BERNARDSTON FARMERS SUPPLY 99401 Lot Size(sq. ft.): 331099.56 Owner: WILMERDING ELIZA Zoning RR(100)/WSP(100)/WP(47)/ Applicant: BERNARDSTON FARMERS SUPPLY AT. 680 NORTH FARMS RD Applicant Address: Phone: Insurance: 43 RIVER ST (413) 648-9311 () WC BERNARDSTONMA01337 ISSUED ON:211012014 0:00:00 TO PERFORM THE FOLLOWING WORK.-INSTALL ENVIRO M55 F/S PELLET STOVE POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType• Date Paid: Amount: Building 2/10/2014 0:00:00 $25.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner