DC315_Cut_Sheet (2) ignition barrier
DC315: Your one step solution for Polyurethane Foam “15 Minute Thermal Barrier” and “Ignition Barrier”
ratings.
DC315 is a Certified Warnock Hersey listed and rated product which has passed certified testing for both
the (UL-1715) 15 minute Thermal Barrier and the NFPA 286 (AC-377 standards) as an Ignition Barrier.
What is truly amazing about DC315, it applies as easy as regular latex paint and being a water base cleans up in a snap. Using
DC315 will satisfy code compliance on”15 Minute Thermal Barriers” and “Ignition Barriers” on your next foam job means:
Large single coat spread rate
UL 1715 Thermal Barrier
o (88.88 sq. ft./gal @ 18 mils wet and 12 mils dry) coverage rate of 1.136 gallons (4.3 L) per 100 square feet (9.3
m2)
NFPA 286 (AC377) Attic Crawl Space Ignition Barrier
o (130 sq. ft./gal @ 12 mils wet 8 mils dry) coverage rate of .77 gallons (2.9 L) per 100 square feet (9.3 m2)
Reduced labor cost, reduced material cost and higher profits
Fast turnaround time
Easily applied with a sprayer, brush or roller
No complicated mixing- just stir the paint before application
No waste
Fast and easy clean up of our water based latex product, tools & equipment
Will not gum up or block spray equipment
Passed strict EPA – VOC and AMQD tests
Non Toxic, Low Vapors, Low VOCs
Two year shelf life
Certified Code Compliant Coating
RECOMMENDED USES: This product is designed for use on interior polyurethane foam surfaces
PRECAUTIONS: Adequate ventilation must be provided during and after application until the coating has dried. Avoid
breathing vapors or spray mist. Close container after use.
Read MSDS before opening containers.
SURFACE PREPARATION: Can be applied directly to fully cured polyurethane foam surfaces. All surface preparation should be
carried out in accordance with good painting practices. Remove all loose, peeling or powdery existing paint from the surface.
All dirt, grease, oil, wax, and other foreign matter MUST be removed with a detergent, rinse surface thoroughly with clear
water, and allow drying.
Application Equipment: DC315 can be applied by brush, roller or airless sprayer.
Brushing: Use top quality polyester/nylon blend brushes such as those supplied by Purdy, Wooster, or equivalent.
Rolling: 3/8” polyester blend nap roller covers generally work well.
Spraying: Pump: (Graco) for best results use Graco 795 airless sprayer, with a minimum 2000 PSI
• Tip: 526 – 529 or equivalent.
• Filter: 60 mesh
• Hose: Use minimum size of 3/8” airless spray line for the first 50’ from pump.
Airless Spray:
• Fluid Pressure: ........................2000 PSI or higher
• Strainer: ..................................60 Mesh
• Fluid Hose: ..............................3/8 diameter with a ¼” whip
• Tip: ..........................................021 - .029
Conventional Spray
• Air Supply…………………………... 12 CFM, 50 psi at nozzle,
• Fluid…………………………………... 15-20 psi
• Gun. ........................................Graco 217-800 to 217-816
• Type ……………………………………External Mix
• Reduction …………………………...Up to 7%
APPLICATION: Stir thoroughly and apply WFT per test.
Do not apply in temperatures below 50ºF (10ºC).
CHARACTERISTICS:
Finish …………………………………………..…Flat
Color …………………………………………..….Off-White
Spreading Rate ………………………….…..For 15 minute Thermal Barrier (88.88 sq. ft./gal @ 18 mil wet and 12 mils Dry) coverage
rate of 1.136 gallons (4.3 L) per 100 square feet (9.3 m2)
Spreading Rate ………………………………For AC377 Attic Crawl Space (130 sq. ft./gal @ 12 mil wet 8 mils Dry) coverage rate of .77
gallons (2.9 L) per 100 square feet (9.3 m2)
V.O.C. ……………………………….….……... (47 g/l)
Volume Solids ………………………….……65%
Drying Time @ 77°F & 50% RH: …….To touch 1-2 hours to recoat 2 to 4 hours
Type of Cure ………………………………….Coalescence
Flash Point ……………………………….……None
Reducer/Cleaner …………………………..Water
Shelf Life ……………………………………….2 years (unopened)
Packaging .…………………………………….1&5 gal. Containers
Shipping weight ……………………………1 gal - 13 lbs
5 gals - 58 lbs
Application …………………………………..Brush, roller, conventional and airless spray