38B-314 (5) Here's the information on the windows:
1.2 WINDOW PERFORMANCE REQUIREMENTS
A. Product Standard: Comply with AAMA/WDMA/CSA 101/I.S.2/A440 for
definitions and minimum standards of performance, materials, components,
accessories, and fabrication unless more stringent requirements are indicated.
1. Window Certification: WDMA certified with label attached to each window.
B. Performance Class and Grade: AAMA/WDMA/CSA 101/I.S.2/A440 as
follows:
1. Minimum Performance Class: R.
2. Minimum Performance Grade: 40.
C. Thermal Transmittance: NFRC 100 maximum whole-window U-factor of
0.27 Btu/sq. ft. x h x deg F for double hung windows and .22 Btu/sq. ft. x h x deg F
for projected windows.
D. Solar Heat-Gain Coefficient (SHGC): NFRC 200 maximum whole-window
SHGC of 0.28 for double hung windows and 0.31 for projected windows.
Windows to be provided are National Vinyl LLC, Northwind III.
From: Kerry Dietz <kerryd@adietzarch.com>
Date: Fri, 1 Nov 2013 18:39:39 +0000
To: Northampton Housing <jhite hamphousing.org>
Conversation: window and door projects
Subject: RE: window and door projects
Here's the spec information on the doors proposed:
A. Insulated Heavy-Duty Doors and Frames: SDI A250.8, Level 2. At
locations indicated in the Door and Frame Schedule.
1. Basis of Design: Imperial (IU) Urethane Core Door with Series SQT/SRT
Thermal Break Frames, Ceco Door Products.
2. Physical Performance: Level B according to SDI A250.4.
3. Doors:
a. Type: As indicated in the Door and Frame Schedule.
b. Thickness: 1-3/4 inches
c. Face: Metallic-coated steel sheet, minimum thickness of 0.042 inch, with
minimum A40 coating.
d. Edge Construction: Model 2, Seamless.
e. Core: Manufacturer's standard polyurethane core.
f. Thermal performance: R-11.
4. Frames:
a. Materials: Metallic-coated steel sheet, minimum thickness of 0.053 inch,
with minimum A40 coating.
b. Construction: Knocked down.
c. Thermal performance: Thermally broken frame.
5. Exposed Finish: Prime.
City of Northampton
,.. '' .,r ti*.
Massachusetts �:i.
i DEPARTMENT OF BUILDING INSPECTIONS
4h
212 Main Street • Municipal Building >tr ,
Northampton, MA 01060 ss111,/%ji~`��
INSPECTOR
Louis Hasbrouck Fax: 413-587-1272 Chuck Miller
Building Commissioner Phone: 413-587-1240 Assistant Commissioner
CONSTRUCTION CONTROL DOCUMENT
(For professional Engineers/Architects responsible for Entire Project)
Renovations to Grace Huse _:; .. her 6; r 13
Project Title: _--__— Date:
14:3 West Street Y '=r_- 314 URC
Project Location: _—_—__ Map _ _ Parcel: Zone:_ __
Replacement of front and reJ r dr- :, 3 id,ci r F.in ft
Scope of Project:___---
In accordance with the Eighth edition Massachusetts State Building Code, 780 CMR Section 107.6:
°.err Dietz X32 4
1, — _ Mass. Registration#_ __---,
Being a registered professional Engineer/Architect hereby CERTIFIES that I have prepared or directly supervised
the preparation of all design plans, computations and specifications concerning:
[Xi ENTIRE PROJECT
For the above named project and that to the best of my knowledge, such plans, computations and specifications
meet the applicable provisions of the Massachusetts State Building Code, all acceptable engineering practices
and all applicable Laws for the proposed project.
Furthermore, I understand and AGREE that I shall perform the necessary professional services to determine that
the above mentioned portions of the work proceed in accordance with the documents approved for the building
permit and shall be responsible for the following as specified in Section 10.7.6.2.2:
1. Review of shop drawings, samples and other submittals of the contractor as required by the
construction documents as submitted for the building permit, and approval for the conformance
to the design concept.
2. Review and approval of the quality control procedures for all code-required controlled materials.
3. Be present at intervals appropriate to the stage of construction to become generally familiar with
the progress and quality of the work and to determine, in general, if the work is being performed
In a matter consistent with the construction documents.
I shall submit periodically, in a form acceptable to the building official, a progress report together with pertinent
comments. Upon completion of the work, I shall submit to the building official a final report as to the satisfactory
completion and readiness of the project for occupancy.
Signature and Seal of Registered Professional tri
No. 5204 ,,,;i*
ce)_ October -- 13 C. tt s - s '
_ Day of__-_— _ -20____ V► N,„„....,46_„c.c:
i
s-,41410
Versionl.7 Commercial Building Permit May 15,2000
SECTION 10-STRUCTURAL PEER REVIEW(780 CMR 110.11)
Independent Structural Engineering Structural Peer Review Required Yes 0 No
SECTION 11 -OWNER AUTHORIZATION-TO BE COMPLETED WHEN
OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT
Jon Hite,Executive Director of the Northampton Housing Authority as Owner of the subject property
Brian Henry of Henry General Contractors, Inc.
hereby authorize to
act on my behalf, in a atters relat e work authorized by this building permit application.
Signature of Owner Date
Brian Henry
as Owner/Authorized
Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge
and belief.
Signed under the pains and penalties of perjury.
Brian Henry
Print Name
l !6/z / Z
S g ature of Owner/Agent Date
SECTION 12-CONSTRUCTION SERVICES
10.1 Licensed Construction Supervisor: Not Applicable ❑
Name of License Holder: Brian Henry CS-084258
License Number
1464 State Street, Springfield, MA 01109 03/03/2015
Address Expiration Date
(413)301-5655
Si ure Telephone
SECTION 13-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6))
Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result
in the denial of the issuance of the building permit.
Signed Affidavit Attached Yes 0 No 0
Versionl.7 Commercial Building Permit May 15,2000
SECTION 9-PROFESSIONAL DESIGN AND CONSTRUCTION SERVICES-FOR BUILDINGS AND STRUCTURES SUBJECT TO
CONSTRUCTION CONTROL PURSUANT TO 780 CMR 116(CONTAINING MORE THAN 35,000 C.F.OF ENCLOSED SPACE)
9.1 Registered Architect:
Dietz &Co. Architects, Inc. 17 Hampden St, Springfield, MA 01103 Not Applicable ❑
Name(Registrant):
5264
Dietz & Co. Architects, Inc. 17 Hampden St, Springfield, MA 01103 Registration Number
Ad• . 08/31/2014
C` , 0 („e-i-2,- (413) 733-6798 Expiration Date
-'.natur: Telephone
9.2 Registered Professional Engineer(s):
Name Area of Responsibility
Address Registration Number
Signature Telephone Expiration Date
Name Area of Responsibility
Address Registration Number
Signature Telephone. Expiration Date
Name Area of Responsibility
Address Registration Number
Signature Telephone Expiration Date
Name Area of Responsibility
Address Registration Number
Signature Telephone Expiration Date
9.3 General Contractor
Henry General Contractors, Inc. Not Applicable ❑
Company Name:
Brian Henry
Responsible In Charge of Construction
1464 State Street, Springfield,MA 01109
Address
(413)301-5655
Signature Telephone
Versionl.7 Commercial Building Permit May 15,2000
8. NORTHAMPTON ZONING
Existing Proposed Required by Zoning
This column to be filled in by
Building Department
Lot Size Existing
Frontage Existing
Setbacks Front Ex.
Side L: R: L:Ex. R:Ex.
Rear Ex.
Building Height Ex.
Bldg. Square Footage % Ex. Ex.
Open Space Footage cYo
(Lot area minus bldg&paved Ex. Ex.
parking)
#of Parking Spaces Ex.
Fill:
(volume&Location) Existing
A. Has a Special Permit/Variance/Finding ever been issued for/on the site?
NO 0 DON'T KNOW 0 YES 0
IF YES, date issued:
IF YES: Was the permit recorded at the Registry of Deeds?
NO 0 DONT KNOW YES 0
IF YES: enter Book Page and/or Document#
B. Does the site contain a brook, body of water or wetlands? NO 0 DONT KNOW 0 YES 0
IF YES, has a permit been or need to be obtained from the Conservation Commission?
Needs to be obtained t Obtained , Date Issued:
C. Do any signs exist on the property? YES 0 NO 0
IF YES, describe size, type and location: Existing
D. Are there any proposed changes to or additions of signs intended for the property? YES 0 NO 0
IF YES, describe size, type and location:
E. Will the construction activity disturb(clearing,grading,excavation, or filling)over 1 acre or is it part of a common plan
that will disturb over 1 acre? YES 0 NO 0
IF YES,then a Northampton Storm Water Management Permit from the DPW is required.
Versionl.7 Commercial Building Permit May 15,2000
SECTION 4-CONSTRUCTION SERVICES FOR PROJECTS LESS THAN 35,000
CUBIC FEET OF ENCLOSED SPACE
Interior Alterations 0 Existing Wall Signs El Demolition❑ Repairs❑ Additions ❑ Accessory Building❑
Exterior Alteration ❑ Existing Ground Sign❑ New Signs❑ Roofing❑ Change of Use❑ Other❑
Brief Description Replacement of front and rear doors. Provision of new screen door. Replacement of existing
Of Proposed Work: windows with new vinyl windows.
SECTION 5-USE GROUP AND CONSTRUCTION TYPE
USE GROUP(Check as applicable) CONSTRUCTION TYPE
A Assembly ❑ A-1 ❑ A-2 ❑ A-3 ❑ 1A I ❑
A-4 ❑ A-5 ❑ 1B ❑
B Business ❑ 2A ❑
E Educational ❑ 2B I ❑
F Factory ❑ F-1 ❑ F-2 ❑ 2C ❑
H High Hazard ❑ 3A ❑
I Institutional ❑ I-1 ❑ 1-2 ❑ 1-3 ❑ 3B ❑
M Mercantile ❑ 4 ❑
R Residential 0 R-1 ❑ R-2 CI R-3 ❑ 5A ❑
S Storage ❑ S-1 ❑ S-2 ❑ 5B D
U Utility ❑ Specify:
M Mixed Use ❑ Specify:
S Special Use ❑ Specify:
COMPLETE THIS SECTION IF EXISTING BUILDING UNDERGOING RENOVATIONS,ADDITIONS AND/OR CHANGE IN USE
Existing Use Group: R-2 Proposed Use Group: R-2
Existing Hazard Index 780 CMR 34): 2 Proposed Hazard Index 780 CMR 34): 2
SECTION 6 BUILDING HEIGHT AND AREA
BUILDING AREA EXISTING PROPOSED NEW CONSTRUCTION OFFICE USE ONLY
Floor Area per Floor(sf)
1St 1St
2nd 2nd
3rd 3rd
4th 4th
Total Area(sf) Total Proposed New Construction(sf)
Total Height(ft)
Total Height ft
7.Water Supply(M.G.L.c.40,§54) 7.1 Flood Zone Information: 7.3 Sewage Disposal System:
Public 13 Private ❑ Zone Outside Flood Zone p Municipal 12 On site disposal system❑
Versionl.7 Commercial Building Permit May 15,2000
��7 i ( °. Department use only
City of Northa L+��n� �� _-_` .._ tatuS o Permit:
!'_o� Permit
Building Depa t Curb iC Driveway
212 Main Str.:�t: ;
2 3 213 Sewell"•ptic Availability
Room 100 - Wat r -II Availability
Northampton, MA1Q1060_ -- . of Structural Plans
phone 413-587-1240 Fax1413-587__1272 _-_ :i,:, • - •tans'
Other Specify
APPLICATION TO CONSTRUCT,REPAIR,RENOVATE,CHANGE THE USE OR OCCUPANCY OF,OR DEMOLISH ANY BUILDING
OTHER THAN A ONE OR TWO FAMILY DWELLING
SECTION 1 -SITE INFORMATION
1.1 Property Address: This section to be completed by office
Grace House Map Lot Unit
143 West Street
Zone Overlay District
Northampton, MA
Elm St.District CB District
SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT
2.1 Owner of Record:
Northampton Housing Authority 49 Old South Street,Northampton,MA
Name(Print) Current Mailing Address:
(413) 584-4030
Signature Telephone
2.2 Authorized Agent:
Brian Henry 1464 State Street, Springfield, MA 01109
Name(Print) Current Mailing Address:
(413) 301-5655
Signature ��- 1 Telephone
SECTION 3-ESTIMATED CONSTR TION COSTS
Item Estimated Cost(Dollars)to be Official Use Only
completed by permit applicant
1. Building $16,200.00 (a)Building Permit Fee
2. Electrical (b)Estimated Total Cost of
Construction from (6)
3. Plumbing Building Permit Fee
4. Mechanical(HVAC)
5. Fire Protection
6. Total=(1 +2+3+4 Check Number W l ..!
This Section For Official Use Only
Building Permit Number r Date
Issued
Signature:
Building Commissioner/Inspector of Buildings Date
File#BP-2014-0531
APPLICANT/CONTACT PERSON HENRY GENERAL CONTRACTORS INC
ADDRESS/PHONE 1464 STATE ST SPRINGFIELD (413)301-5655
PROPERTY LOCATION 143 WEST ST-GRACE HOUSE
MAP 38B PARCEL 314 001 ZONE URC(111)/WP(101)/
THIS SECTION FOR OFFICIAL USE ONLY:
PERMIT APPLICATION CHECKLIST
ENCLOSED REQUIRED DATE
ZONING FORM FILLED OUT
Fee Paid
Building Permit Filled out /a/ Q ti 9 l
Fee Paid f�/ 0 1�
Typeof Construction: INSTALL REPLACEMENT FRONT&REAR DOORS &REPLACEMENT WINDOWS
New Construction
Non Structural interior renovations
Addition to Existing
Accessory Structure
Building Plans Included:
Owner/Statement or License 084258 bier__
3 sets of Plans I Plot Plan
THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON
INFO R TION PRESENTED:
pproved Additional permits required(see below)
PLANNING BOARD PERMIT REQUIRED UNDER:§
Intermediate Project: Site Plan AND/OR Special Permit With Site Plan
Major Project: Site Plan AND/OR Special Permit With Site Plan
ZONING BOARD PERMIT REQUIRED UNDER: §
Finding Special Permit Variance*
Received&Recorded at Registry of Deeds Proof Enclosed
Other Permits Required:
Curb Cut from DPW Water Availability Sewer Availability
Septic Approval Board of Health Well Water Potability Board of Health
Permit from Conservation Commission Permit from CB Architecture Committee
Permit from Elm Street Commission Permit DPW Storm Water Management
4,,,„" 7 elay
iiir
if //-3 - /,
Signa e of Buil.ing ficial Date
Note:Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning
requirements and obtain all required permits from Board of Health,Conservation Commission,Department
of public works and other applicable permit granting authorities.
*Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of
Planning&Development for more information.
143 WEST ST-GRACE HOUSE BP-2014-0531
GIS#: COMMONWEALTH OF MASSACHUSETTS
Map:Block: 38B-314 CITY OF NORTHAMPTON
Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
Category:REPLACEMENT DOOR BUILDING PERMIT
Permit# BP-2014-0531
Project# JS-2014-000913
Est. Cost: $16200.00
Fee: $97.00 PERMISSION IS HEREBY GRANTED TO:
Const. Class: Contractor: License:
Use Group: HENRY GENERAL CONTRACTORS INC 084258
Lot Size(sq. ft.): 69696.00 Owner: NORTHAMPTON HOUSING AUTHORNY
Zoning:URC(111)/WP(101)/ Applicant: HENRY GENERAL CONTRACTORS INC
AT: 143 WEST ST - GRACE HOUSE
Applicant Address: Phone: Insurance:
1464 STATE ST (413) 301-5655
SPRINGFIELDMA01109 ISSUED ON:11/4/2013 0:00:00
TO PERFORM THE FOLLOWING WORK:INSTALL REPLACEMENT FRONT & REAR
DOORS & REPLACEMENT WINDOWS
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter:
Footings:
Rough: Rough: House# Foundation:
Driveway Final:
Final: Final:
Rough Frame:
Gas: Fire Department Fireplace/Chimney:
Rough: Oil: Insulation:
Final: Smoke: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Certificate of Occupancy Signature:
FeeType: Date Paid: Amount:
Building 11/4/2013 0:00:00 $97.00
212 Main Street,Phone(413)587-1240,Fax: (413)587-1272
Louis Hasbrouck—Building Commissioner