38B-006 (39)
4lntegrity Integrity Windows and Doors NFRC Values Windows and Doors Ultrex Glider- Standard Glass A- sc.: 4 Canada Glass Description Divider U Factor SHGC VT CR Energy Star Energy Star 11/16"1G LoE 366 Argon Obscure 0.30 0.22 0.51 56 N,NC,SC,S A 3.1 mm LoE 366/11.5mm argon/3.1 mm obscure GBG 0.30 0.20 0.46 56 N,NC,SC,S 11/16"IG LoE 366 Argon 0.30 0.22 0.51 56 N,NC,SC,S A 3.1 mm LoE 366/11.5mm argon/3.1 mm clr GBG 0.30 0.20 0.46 56 N,NC,SC,S 11/16"IG LoE 366 Air Obscure 0.34 0.22 0.51 54 SC,S 3.1 mm LoE 366/11.5mm air/3.1 mm obscure GBG 0.34 0.20 0.46 54 SC,S 11/16"IG LoE 366 Air 0.34 0.22 0.51 54 SC,S 3.1 mm LoE 366/11.5mm air/3.1 mm clr GBG 0.34 0.20 0.46 54 SC,S 11/16"IG LoE 272 Argon Obscure 0.31 0.33 0.57 56 NC A 3.1 mm LoE 272/11.5mm argon/3.1 mm obscure GBG 0.31 0.30 0.51 56 NC,SC A 11/16"IG LoE 272 Argon 0.31 0.33 0.57 56 NC A 3.1 mm LoE 272/11.5mm argon/3.1 mm clr GBG 0.31 0.30 0.51 56 NC,SC A 11/16"1G LoE 272 Air Obscure 0.35 0.33 0.57 54 3.1 mm LoE 272/11.5mm air/3.1 mm obscure GBG 0.35 0.30 0.51 54 SC 11/16"IG LoE 272 Air 0.35 0.33 0.57 54 3.1 mm LoE 272/11.5mm air/3.1 mm clr GBG 0.35 0.30 0.51 54 SC 11/16"IG Argon LoE 180 0.33 0.56 0.62 56 A,B,C 3.1 mm clr/11.5mm argon/LoE 180 3.1 mm GBG 0.33 0.50 0.56 56 A,B 11/16''1G Air LoE 180 0.37 0.55 0.62 53 3.1 mm clr/11.5mm air/LoE 180 3.1 mm GBG 0.37 0.50 0.56 53 CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On:Aug 20,2013,9:50 am 2012-06-25 NFRC-63 Integrity Windows and Doors NFRC Values /VFRG ���". .VIN�:- S, R«0.M„'„ Built around you: Clad Ultimate Awning OF 4 Canada Glass Description Divider U Factor SHGC VT CR Energy Star Energy Star 0.29 0.19 0.44 57 N,NC,SC,S A SDLS>1" 029 0.16 0.36 57 N,NC,SC,S A 3/4"1G LoE 366 Argon SDLS<1 " 0.29 0.18 0.40 57 N,NC,SC,S A 3.1 mm 366 I 13.0mm arg/3.1 mm clr SDLN>1 " 0.29 0.16 0.36 57 N,NC,SC,S A SDLN<1 " 0.29 0.18 0.40 57 N,NC,SC,S A GBG 0.29 0.18 0.40 57 N,NC,SC,S A 0.32 0.19 0.44 54 NC,SC,S SDLS>1" 0.32 0.16 0.36 54 NC,SC,S 3/4"IG LoE 366 Air SDLS<1 " 0.32 0.18 0.40 54 NC,SC,S 3.1 mm 366/13.0mm air/3.1 mm clr SDLN>1" 0.32 0.16 0.36 54 NC,SC,S SDLN<1" 0.32 0.18 0.40 54 NC,SC,S GBG 0.32 0.18 0.40 54 NC,SC,S 0.30 0.29 0.49 57 N,NC,SC A SDLS>1 " 0.30 0.24 0.40 57 N,NC,SC,S A 3/4"IG LoE 272 Argon SDLS<1" 0.30 0.26 0.44 57 N,NC,SC,S A 3.1 mm 272/13.0mm arg/3.1 mm clr SDLN>1 " 0.30 0.24 0.40 57 N,NC,SC,S A SDLN<1" 0.30 0.26 0.44 57 N,NC,SC,S A GBG 0.30 0.26 0.44 57 N,NC,SC,S A 0.33 0.29 0.49 53 SC SDLS>1 " 0.33 0.24 0.40 53 SC,S 3/4"IG LoE 272 Air SDLS<1 " 0.33 0.26 0.44 53 SC,S 3.1 mm 272/13.0mm air!3.1 mm clr SDLN>1" 0.33 0.24 0.40 53 SC,S SDLN<1" 0.33 0.26 0.44 53 SC,S GBG 0.33 0.26 0.44 53 SC,S 0.30 0.47 0.54 57 N A,B,C SDLS>1 " 0.30 0.39 0.44 57 N,NC A,B 3/4"IG Argon LoE 180 SDLS<1 " 0.30 0.43 0.49 57 N A,B 3.1 mm clr/13.0mm arg/180 3.1 mm SDLN>1" 0.30 0.39 0.44 57 N,NC A,B SDLN<1" 0.30 0.43 0.49 57 N A,B GBG 0.30 0.43 0.49 57 N A,B 0.33 0.47 0.54 53 A,B SDLS>1 " 0.33 0.39 0.44 53 A 3/4"IG Air LoE 180 SDLS<1" 0.33 0.43 0.49 53 A 3.1 mm clr!13.0mm air/180 3.1 mm SDLN>1 " 0.33 0.39 0.44 53 A SDLN<1 " 0.33 0.43 0.49 53 A GBG 0.33 0.43 0.49 53 A 3/4"IG Air 0.45 0.53 0.56 43 3.1 mm clr/13.0mm air/3.1 mm clr 0.29 0.19 0.43 54 N,NC,SC,S A SDLS>1 " 0.29 0.16 0.35 54 N,NC,SC,S A 1"1G LoE 366 Argon SDLS<1 " 0.29 0.17 0.39 54 N,NC,SC,S A 4.7mm 366/16.0mm arg/4.7mm dr SDLN>1 " 0.29 0.16 0.35 54 N,NC,SC,S A SDLN<1 " 0.29 0.17 0.39 54 N,NC,SC,S A GBG 0.29 0.17 0.39 54 N,NC,SC,S A 0.32 0.19 0.43 51 NC,SC,S SDLS>1 " 0.32 0.16 0.35 51 NC,SC,S 1"IG LoE 366 Air SDLS<1 " 0.32 0.18 0.39 51 NC.SC,S 4.7mm 366/16.0mm air/4.7mm clr SDLN>1" 0.32 0.16 0.35 51 NC,SC,S SDLN<1" 0.32 0.18 0.39 51 NC,SC,S GBG 0.32 0.18 0.39 51 NC,SC,S 0.30 0.28 0.48 54 N,NC,SC A SDLS>1 " 0.30 0.23 0.39 54 N,NC,SC,S A 1"IG LoE 272 Argon SDLS<1 " 0.30 0.26 0.44 54 N,NC,SC,S A 4.7mm 272/16.0mm arg/4.7mm clr SDLN>1 " 0.30 0,23 0.39 54 N,NC,SC,S A SDLN<1 " 0.30 0.26 0.44 54 N,NC,SC,S A GBG 0.30 0.26 0.44 54 N,NC,SC,S A ABU6006-1 CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On:Aug 20,2013,9:47 am NFRC-8 19972255 Ver2012.1 2012-11-05 Marvin Architectural Detail Manual 4 b ° MARVIN-' NFRC t y t - °> $d Built around you: Clad Ultimate Double Hung Magnum 2 4- Canada Glass Description Divider U Factor SHGC VT CR Energy Star Energy Star 7/8"Tri-Pane LoE 366 Krypton-Argon LoE 180 0.23 0.18 0.40 66 N,NC,SC,S A,B,C 3.1 mm 366/6.5mm kry-arg/3.1 mm clr/6.5mm SDLN>1" 0.23 0.15 0.32 66 N,NC,SC,S A,B kry-arg/180 3.1 mm SDLN<1 " 0.23 0.16 0.36 66 N,NC,SC,S A,B 7/8"Tri-Pane LoE 366 Argon LoE 180 0.26 0.18 0.40 64 N,NC,SC,S A,B 3.1 mm 366/6.5mm arg/3.1 mm clr!6.5mm arg/ SDLN>1" 0.26 0.15 0.32 64 N,NC,SC,S A 180 3.1 mm SDLN<1 " 0.26 0.16 0.36 64 N,NC,SC,S A 7/8"Tri-Pane LoE 272 Krypton-Argon LoE 272 0.23 0.25 0.41 66 N,NC,SC,S A,B,C 3.1 mm 272/6.5mm kry-arg/3.1 mm clr/6.5mm SDLN>1 " 0.23 0.20 0.32 66 N,NC,SC,S A,B,C kry-arg/272 3.1 mm SDLN<1" 0.23 0.23 0.36 66 N,NC,SC,S A,B,C 7/8"Tri-Pane LoE 272 Argon LoE 272 0.25 0.25 0.41 64 N,NC,SC,S A,B,C 3.1 mm 272/6.5mm arg/3.1 mm clr/6.5mm arg/ SDLN>1" 0.25 0.20 0.32 64 N,NC,SC,S A,B 272 3.1 mm SDLN<1" 0.25 0.23 0.36 64 N,NC,SC,S A,B,C 7/8"Tri-Pane LoE 180 Krypton-Argon LoE 180 0.23 0.40 0.50 66 N,NC A,B,C,D 3.1 mm 180/6.5mm kry-arg/3.1 mm clr/6.5mm SDLN>1 " 0.23 0.32 0.39 66 N,NC A,B,C kry-arg/180 3.1 mm SDLN<1" 0.23 0.36 0.44 66 N,NC , A,B,C 7/8"Tri-Pane LoE 180 Argon LoE 180 0.26 0.40 0.50 63 N,NC A,B,C 3.1 mm 180/6.5mm arg/3.1 mm clr/6.5mm arg/ SDLN>1" 0.26 0.32 0.39 63 N,NC A,B 180 3.1 mm SDLN<1 " 0.26 0.36 0.44 63 N,NC A,B 11/16"IG LoE 366 Argon w/Combination Comb 3.1 mm clr/1.331"air 13.1 mm 366/ 0.23 0.21 0.42 65 N,NC,SC,S A,B,C 11.5mm arg 13.1 mm clr 0.30 0.20 0.46 56 N,NC,SC,S A SDLS>1 " 0.30 0.16 0.36 56 N,NC,SC,S 11/16"1G LoE 366 Argon SDLS<1 " 0.30 0.18 0.41 56 N,NC,SC,S A 3.1 mm 366/11.5mm arg/3.1 mm clr SDLN>1 " 0.30 0.16 0.36 56 N,NC,SC,S SDLN<1 " 0.30 0.18 0.41 56 N,NC,SC,S A GBG 0.30 0.18 0.41 56 N,NC,SC,S A 0.33 0.20 0.46 53 SC,S SDLS>1 " 0.33 0.16 0.36 53 SC,S 11/16"IG LoE 366 Air SDLS<1 " 0.33 0.18 0.41 53 SC,S 3.1 mm 366/11.5mm air/3.1 mm clr SDLN>1 " 0.33 0.16 0.36 53 SC,S SDLN<1 " 0.33 0.18 0.41 53 SC,S GBG 0.33 0.18 0.41 53 SC,S 11/16"IG LoE 272 Argon w/Combination Comb 3.1 mm clr/1.331"air/3.1 mm 2721 0.24 0.30 0.47 65 N,NC,SC A,B,C 11.5mm arg/3.1 mm clr w 0.30 0.30 1 0.51 56 N,NC,SC A SDLS>1" 0.30 0.24 0.40 56 N,NC,SC,S A 11/16 IG LoE 272 Argon SDLS<1 " 0.30 0.27 0.45 56 N,NC,SC,S A 3.1 mm 272/11.5mm arg/3.1 mm clr SDLN>1 " 0.30 0.24 0.40 56 N,NC,SC,S A SDLN<1" 0.30 0.27 0.45 56 N,NC,SC,S A GBG 0.30 0.27 0.45 56 N,NC,SC,S A 0.34 0.30 0.51 53 SC SDLS>1 " 0.34 0.24 0.40 53 SC,S 11/16"IG LoE 272 Air SDLS<1 " 0.34 0.27 0.45 53 SC,S 3.1 mm 272/11.5mm air/3.1 mm clr SDLN>1 " 0.34 0.24 0.40 53 SC,S SDLN<1 " 0.34 0.27 0.45 53 SC,S GBG 0.34 0.27 0.45 53 SC,S 11/16"IG Argon LoE 180 w/Combination Comb 3.1 mm clr 1 1.331"air!3.1 mm clr/11.5mm 0.24 0.44 0.52 64 N A,B,C,D arg/180 3.1 mm 0.31 0.49 0.56 55 N A,B,C SDLS>1 " 0.31 0.39 0.44 55 N,NC A 11/16"IG Argon LoE 180 SDLS<1 " 0.31 0.44 0.50 55 N A,B 3.1 mm clr/11.5mm arg/180 3.1 mm SDLN>1 " 0.31 0.39 0.44 55 N,NC A SDLN<1" 0.31 0.44 0.50 55 N A,B GBG 0.31 0.44 0.50 55 N A,B ABSC-1 CHECK MARVIN ONLINE DOGS FOR LATEST VERSION Printed On:Aug 20,2013,9:44 am NFRC-39 19972255 Ver 2012.1 2012-11-05 Marvin Architectural Detail Manual MARVIN . NFRC = - > .,.,, Built around ou: Clad Ultimate Double Hung/Single Hung d Canada Glass Description Divider U Factor SHGC VT CR Energy Star Energy Star 7/8"Tri-Pane LoE 366 Krypton-Argon LoE 180 0.23 0.18 0.40 66 N,NC,SC,S A,B,C 3.1 mm 366/6.5mm kry-arg/3.1 mm clr/6.5mm SDLN>1" 0.23 0.15 0.32 66 N,NC,SC,S A,B kry-arg/180 3.1 mm SDLN<1" 0.23 0.16 0.36 66 N,NC,SC,S A,B 7/8"Tri-Pane LoE 366 Argon LoE 180 0.25 0.18 0.40 64 N,NC,SC,S A,B 3.1 mm 366/6.5mm arg/3.1 mm clr/6.5mm arg/ SDLN>1" 0.25 0.15 0.32 64 N,NC,SC,S A,B 180 3.1 mm SDLN<1 " 0.25 0.16 0.36 64 N,NC,SC,S A,B 7/8"Tri-Pane LoE 272 Krypton-Argon LoE 272 0.23 0.25 0.41 66 N,NC,SC,S A,B,C 3.1 mm 272/6.5mm kry-arg/3.1 mm clr/6.5mm SDLN>1" 0.23 0.20 0.32 66 N,NC,SC,S A,B,C kry-arg/272 3.1 mm SDLN<1" 0.23 0.23 0.36 66 N,NC,SC,S A,B,C 7/8"Tri-Pane LoE 272 Argon LoE 272 0.25 0.25 0.41 64 N,NC,SC,S A,B,C 3.1 mm 272/6.5mm arg/3.1 mm clr/6.5mm arg/ SDLN>1 " 0.25 0.20 0.32 64 N,NC,SC,S A,B 272 3.1 mm SDLN<1" 0.25 0.23 0.36 64 N,NC,SC,S A,B,C 7/8"Tri-Pane LoE 180 Krypton-Argon LoE 180 0.23 0.40 0.50 66 N,NC A,B,C,D 3.1 mm 180/6.5mm kry-arg/3.1 mm clr/6.5mm SDLN>1 " 0.23 0.32 0.39 66 N,NC A,B,C kry-arg/180 3.1 mm SDLN<1" 0.23 0.36 0.44 66 N,NC A,B,C 7/8"Tri-Pane LoE 180 Argon LoE 180 0.26 0.40 0.50 63 N,NC A,B,C 3.1 mm 180/6.5mm arg/3.1 mm clr/6.5mm arg/ SDLN>1" 0.26 0.32 0.39 63 N,NC A,B 180 3.1 mm SDLN<1" 0.26 0.36 0.44 63 N,NC A,B 11/16"IG LoE 366 Argon w/Combination Comb 3.1 mm clr/1.331"air/3.1 mm 366/ 0.23 0.21 0.42 70 N,NC,SC,S A,B,C 11.5mm arg/3.1 mm clr 0.29 0.20 0.46 56 N,NC,SC,S A SDLS>1 " 0.30 0.16 0.36 56 N,NC,SC,S 11/16"IG LoE 366 Argon SDLS<1 " 0.30 0.18 0.41 56 N,NC,SC,S A 3.1 mm 366/11.5mm arg/3.1 mm clr SDLN>1 " 0.29 0.16 0.36 56 N,NC,SC,S A SDLN<1 " 0.29 0.18 0.41 56 N,NC,SC,S A GBG 0.29 0.18 0.41 56 N,NC,SC,S A 0.33 0.20 0.46 53 SC,S SDLS>1" 0.33 0.16 0.36 53 SC,S 11/16"IG LoE 366 Air SDLS<1 " 0.34 0.18 0.41 53 SC,S 3.1 mm 366/11.5mm air/3.1 mm clr SDLN>1 " 0.33 0.16 0.36 53 SC,S SDLN<1 " 0.33 0.18 0.41 53 SC,S GBG 0.33 0.18 0.41 53 SC,S 11/16"IG LoE 272 Argon w/Combination Comb 3.1 mm clr/1.331'air/3.1 mm 272/ 0.24 0.30 0.47 70 N,NC,SC A,B,C 11.5mm arg/3.1 mm clr 0.30 0.30 0.51 56 N,NC,SC A SDLS>1 0.30 0.24 0.40 56 N,NC,SC,S A 11/16"tG LoE 272 Argon SDLS<1 " 0.31 0.27 0.45 56 NC,SC,S A 3.1 mm 272/11.5mm arg/3.1 mm clr SDLN>1 " 0.30 0.24 0.40 56 N,NC,SC,S A SDLN<1 " 0.30 0.27 0.45 56 N,NC,SC,S A GBG 0.30 0.27 0.45 56 N,NC,SC,S A 0.33 0.30 0.51 53 SC SDLS>1 " 0.34 0.24 0.40 53 SC,S 11/16"IG LoE 272 Air SDLS<1 " 0.34 0.27 0.45 53 SC,S 3.1 mm 272/11.5mm air/3.1 mm clr SDLN>1" 0.33 0.24 0.40 53 SC,S SDLN<1 " 0.33 0.27 0.45 53 SC,S GBG 0.33 0.27 0.45 53 SC,S 11/16"IG Argon LoE 180 w/Combination Comb 3.1 mm clr/1.331"air/3.1 mm clr/11.5mm 0.24 0.44 0.52 70 N A,B,C,D arg/180 3.1 mm 0.31 0.49 0.56 55 N A,B,C SDLS>1 " 0.31 0.39 0.44 55 N,NC A 11/16"IG Argon LoE 180 SDLS<1 " 0.31 0.44 0.50 55 N A,B 3.1 mm clr/11.5mm arg/180 3.1 mm SDLN>1 " 0.31 0.39 0.44 55 N,NC A SDLN< 1 " 0.31 0.44 0.50 55 N A,B GBG 0.31 0.44 0.50 55 N A,B ABEC-1 CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed On:Aug 20,2013,9:43 am NFRC-35 19972255 Ver 2012.1 2012-11-05 Marvin Architectural Detail Manual Linda Gaudreau From: eDEPConfirmation @massmail.state.ma.us Sent: Tuesday, August 06, 2013 2:18 PM To: Linda Gaudreau Subject: eDEP Submittal Confirmation for DEP Transaction ID: 584516 Thank you for using eDEP Online Filing from the Massachusetts Department of Environmental Protection.Your transaction is complete and has been submitted to MassDEP. This email is your receipt for the eDEP Online Filing transaction described below. Please review it and keep a copy for your records. Please do NOT reply to this message, this email address will not receive messages. For assistance with eDEP Online Filing, please email the EEA Help Desk at mailto:helpdesk.eea@massmail.state.ma.us or call 617-626-1111. MassDEP is interested in how we can serve you better.To help us make improvements to eDEP, please take a minute to complete our eDEP Online Filing Survey at http://www.mass.gov/eea/agencies/massdep/service/online/edep-contacts- and-feedback.html. To contact MassDEP Programs, please see http://mass.gov/dep/about/contacts.htm. DEP Transaction ID: 584516 Date and Time Submitted: 08/06/2013 02:17:54 ************************************************************************************** Form Name: AQ 06-Construction/Demolition Notification Payment Information DEP code Date Amount ($) Payment Detail Contractor Contractor Number Name Address Supervisor Project Monitor Lab ************************************************************************************** EMAIL ID OF THE USER: LGaudreau@Wright-Builders.com ************************************************************************************** 1 A eDEP- MassDEP's OnlineFiling System https://edep.dep.mass.gov/Pages/PrintReceipt.aspx MassDEP Home I Contact Privacy Policy MassDEP's Online Filing System Username:GAUDREAU Nickname:CINDERELLA OG OFF My eDEP FormsEva My Profiles Help [ Receipt 441411 dofiig-,e�=a...u.i4C). Forms Signature Receipt Summary/Receipt print receipt Exit Your submission is complete. Thank you for using DEP's online reporting system. You can select"My eDEP" to see a list of your transactions. DEP Transaction ID: 584516 Date and Time Submitted: 8/6/2013 2:17:54 PM Other Email : Form Name: AQ 06 - Construction/Demolition Notification Payment Information DEP code Date Amount ($) Payment Detail Contractor Contractor Number Name Address, , Supervisor Project Monitor Lab My eDEP MassDEP Home I Contact I Privacy Policy MassDEP's Online Filing System ver.11.17.2.0© 2013 MassDEP 1 of 1 8/6/2013 2:18 PM Massachusetts Department of Environmental Protection Bureau of Waste Prevention • Air Quality 100182917 BWP J w 06 Decal Number Notification Prior to Construction or Demolition C. General Construction or Demolition Description (cont.) 6. a. If this is a demolition project,were the structure(s) surveyed for the presence of asbestos containing material (ACM)? El Yes El No If yes,who conducted the survey? CARDNO ATC b Surveyor Name A000005 c Division of Occupational Safety Certification Number 18/26/2013 1/31/2014 7. Construction or Demolition. w a Start Date(mmiddfyyyy) b End Date(mmtddtyyyy) 8. a. For demolition and construction projects, indicate dust suppression techniques to be used: seeding paving b. If other, please specify: wetting shrouding a; covering other 9. For Emergency Demolition Operations, who is the DEP official who evaluated the emergency? a Name of DEP Official 4 b Title k l i c Date(mmi'ddiyyyy)of Authorization d.DEP Waiver Number D. Certification I certify that I have examined the LINDA GAUDREAU Name o above and that to the best of m y Print_ Nar o knowledge it is true and complete. LINDA GAUDREAU The signature below subjects the b Authonfed Signature (N1 signer to the general statutes ;OPERATIONS MANAGER o regarding a false and misleading os;tion.rifle statement(s) ;WRIGHT BUILDERS, INC. d Representing 18/6/2013 cfl e Date(mm/dd yyYy) O 0 ■ ageb doc• 10/02 BWP AD 06•Page 3 of 3■ Massachusetts Department of Environmental Protection Bureau of Waste Prevention • Air Quality 100182917 BW P AQ 06 Decal Number Notification Prior to Construction or Demolition General B. General Project Description (cont.) Statement: If 1 P asbestos is found during a 4. General Contractor: Construction or Demolition WRIGHT BUILDERS, INC operation,all responsible parties am mName roust comply with 48 BATES STREET 310 CMR 7 00, b Address 09, 15,arid NORTHAMPTONMA 101060 Chapter 21E of the General Laws of c City/Town d State e Zip Code the Commonwealth 4135868287 but mited to,flinclude, Telephone and extension) q E-mail Address(optional) This would ot be :DAVID LABONTE(area an asbestos removal h On-site Manager Name nutificatrun with the Department and/or a notice of release/threat of C. General Construction or Demolition Description release of a hazardous substance to the 1. Construction or demolition contractor: Department,it .... applicable. !WILCOX BUILDERS a Name 7 PORTER STREET b Address ;SOUTH DEERFIELD i :MA °01373 c City Town d State e Zip Code '4136658269 f.Telephone Number(area code and extension) g E-mail Address(optional) MATT WILCOX h On-site Manager Name 2. On-Site Supervisor: MATT WILCOX On Site Supervisor Name 3. Is the entire facility to be demolished? �� Yes 141 No N 0 4. Describe the area(s)to be demolished: .REMOVE EXISTING WINDOWS ° 5. If this is a construction project, describe the building(s)or addition(s)to be constructed: =REPLACEMENT WINDOWS 0 0 • ag06 doc• 10/02 BWPAG06•Page 2of3 ■ . , , - L 1 Massachusetts Department of Environmental Protection III of Waste Prevention • Air Quality '100182917 , , Bwp AQ 06 Decal Number Notification Prior to Construction or Demolition Important: _- __ _... .._... ....... . . __.. ._ __-_____ then filling out A. Applicability forms on the computer,use only the tab key A Construction or Demolition operation of an industrial, commercial, or institutional building, or to move your residential building with 20 or more units is regulated by the Department of Environmental Protection cursor-do not use the return (DEP), Bureau of Waste Prevention -Air Quality Control Regulations 310 CMR 7.09. Notification of key Construction or Demolition operations is required under 310 CMR 7.09 (2)ten (10)days prior to any work being performed. The following information is required pursuant to 310 CMR 7.09. rah If X` B. General Project Description 1. a. Is this facility fee exempt- city, town, district, municipal housing authority, owner-occupied Instructions residence of four units or less? ` ,Yes , No 1 his form All sects r ons of b. Provide blanket decal number if applicable: 1 must be Blanket Decal Number , completed in order to comply with the 2. Facility Information: Department of Depomm� of SMITH COLLEGE - FACILITIES Protection a Name notification '126 WEST STREET . requirements of b Address 310 CNN l 07 NORTHAMPTON ;MA I 01063 c.City/Town . ... d State e Zip-Code 4 135852406 ._ ...�� �._. �...... ._..w.. 13 f Telephone Number(area code and extension) q E-mail Address(optional) !48000 2 h Size of Facility in Square Feet i Number of Floors j. Was the facility built prior to 1980? 4 ! Yes ) v■ No k. Describe the current or prior use of the facility: BUSINESS I. Is the facility a residential facility? 1 Yes 14__ No , ° m. If yes, how many units? Number of Units ;° 3. Facility Owner: IN SMITH COLLEGE ' o a Name ° `:126 WEST STREET b Address NORTHAMPTON_ MA 101063 - co c City/Town __ d State e ZIP Code , 0 14135852406 ,f Telephone Number(area code and extension) a E-mail Address(optional) a 'PETER GAGNON Q h Onsite Manager Name • ag00 dor_• 10/02 BWP AC)06•Page 1 of 3• City of Northampton aYe+aa�iY� i4o °h s, Massachusetts irr 4 DEPARTMENT OF BUILDING INSPECTIONS 4 1 `�rr�"%,5 'r 212 Main Street • Municipal Building ob, Ob, --• Northampton, MA 01060 fsfr,, C° INSPECTOR Louis Hasbrouck Fax: 413-587-1272 Chuck Miller Building Commissioner Phone: 413-587-1240 Assistant Commissioner CONSTRUCTION CONTROL DOCUMENT (For professional Engineers/Architects responsible for Entire Project) • Project Title:fAACItI&S (174We4 )V�1 O�V di4rn C Date t ,u 1 I 1 1013 Project Location: /SV i 1 C.o$ a V c.. Map: Parcel: Zone: Scope of Project: WIN,oDIA / (LRlaCtviuM,I IMCt4IV It441DIr I4 ASD Med WO(1 - - In accordance with the Eighth edition Massachusetts State Building Code, 780 CMR Section 107.6: UV`61 1 1 GV1 Mass. Registration# , Being a registered professional Engineer/Architect hereby CERTIFIES that I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning: [ ] ENTIRE PROJECT For the above named project and that to the best of my knowledge, such plans, computations and specifications meet the applicable provisions of the Massachusetts State Building Code, all acceptable engineering practices and all applicable Laws for the proposed project. Furthermore, I understand and AGREE that I shall perform the necessary professional services to determine that the above mentioned portions of the work proceed in accordance with the documents approved for the building permit and shall be responsible for the following as specified in Section 10.7.6.2.2: 1. Review of shop drawings, samples and other submittals of the contractor as required by the construction documents as submitted for the building permit, and approval for the conformance to the design concept. 2. Review and approval of the quality control procedures for all code-required controlled materials. 3. Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine, in general, if the work is being performed In a matter consistent with the construction documents. I shall submit periodically, in a form acceptable to the building official, a progress report together with pertinent comments. Upon completion of the work, I shall submit to the building official a final report as to the satisfactory completion and readiness of the project for occupancy. ,ctsIED Age -° 4(1 JPP E.FAT 0 Signat nd Seal of Registered Professional qy Q. p No.8835 AMHERST Day of St 20 \ MASS `9!(seal) r i Versionl.7 Commercial Building Permit May 15,2000 SECTION 10-STRUCTURAL PEER REVIEW(780 CMR 110.11) Independent Structural Engineering Structural Peer Review Required Yes 0 No SECTION 11 -OWNER AUTHORIZATION ;TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, 5 MI1 co u&- & 4.(r / e s {J as Owner of the subject property C?it- Cco'Jc- - d‘tPe.ei-to hereby authorize (PM' `4 ► 4 u (s( to act on my behalf, m- -r -lax,' - to work authorized by this building permit application. Signature of Owner Date I, VI A.6.t !.. 6 0 t E,,ri as Owner 'uthorized td■rgalthereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge elief. Signed under the pains and penaltie of perjury. Pint me // J / /12i4-1 X 7 .02-//3 Signature • e ner/Agent Date SE' ON 12-CONSTRUCTION SERVICES 10.1 Licensed Construction Supervisor: ,I w� /� p, Not Applicable ❑ Name of License Holder: V"e1,V l*-6Vt"�� 1'�( p. i-e1 4 639b License Number cg z kTe s , Nb ,rk A,Aetc) r) / '/� Address / O O D Expiration Date X°` l .�.. is-- ., e Telephone SECTION 13-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes N No 0 Versionl.7 Commercial Building Permit May 15,2000 SECTION 9-PROFESSIONAL DESIGN AND CONSTRUCTION SERVICES-FOR BUILDINGS AND STRUCTURES SUBJECT TO CONSTRUCTION CONTROL PURSUANT TO 780 CMR 116(CONTAINING MORE THAN 35,000 C.F.OF ENCLOSED SPACE) 9.1 Registered Architect: Not Applicable ❑ Name(Registrant): 1 ��,/ t. k to 17 ( T 1 �� V d 1Aa /� ( egistration ti Number •sdregs,l t � T�� 1`�4 r Expiration Date 11#144pl 0( t.nature Telephone 9.2 Registered Professional Engineer(s): Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date 9.3 General Contractor VV v r !YV / ft)+0 /•`kJ P. LO `t f( Not Applicable ❑ Company Name: 1* (fit e (,-V°i p� -�(G • /b I -l0 Responsible In Charge of onstruction c.,Cf N /�p''1' Q B T . �� b121-Xq,1 f'-t% N M �..(( Address 1gW1 ) Signatur W Telephone pi/lit/ NOW lttrb f -fio k tfr tNThf kr-fs* -hits 6 Versionl.7 Commercial Building Permit May 15,2000 -ij ri 8. NORTHAMPTON ZONING Existing Proposed Required by Zoning This column to be filled .y Building Departme Lot Size Frontage Setbacks Front Side L: R: L: • Rear Building Height Bldg. Square Footage Open Space Footage % (Lot area minus bldg&paved parking) #of Parking S .•-s Fil • olume&Location) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO 0 DON'T KNOW \52iZ. YES Q IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO Q DON'T KNOW (0 YES Q IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW Q YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained 0 , Date Issued: C. Do any signs exist on the property? YES NO Q IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES 0 NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,exc vation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES 0 NO IF YES, then a Northampton Storm Water Management Permit from the DPW is required. Versionl.7 Commercial Building Permit May 15,2000 SECTION 4-CONSTRUCTION SERVICES FOR PROJECTS LESS THAN 35,000 CUBIC FEET OF ENCLOSED SPACE Interior Alterations ❑ Existing Wall Signs ❑ Demolition❑ Repairs❑ Additions ❑ Accessory Building❑ Exterior Alteration 0 Existing Ground Sign❑ New Signs 0 Roofing❑ Change of Use 0 Other Brief Description Enter a brief description here. R ,-`P M -r- (4/1 pi D"tN Of Proposed Work: n /i �/l/l -14.r„ i � 6,U ( t / A u ut/ Ye ' SECTION 5-USE GROUP AND CONSTRUCTION TYPE �Tv USE GROUP(Check as applicable) CONSTRUCTION TYPE A Assembly ❑ A-1 ❑ A-2 ❑ A-3 ❑ 1A ❑ A-4 ❑ A-5 ❑ 1B ❑ B Business ' 2A ❑ E Educational ❑ 2B I ❑ F Factory ❑ F-1 El F-2 0 2C ❑ H High Hazard ❑ 3A ❑ I Institutional ❑ 1-1 ❑ 1-2 ❑ 1-3 ❑ 3B ❑ M Mercantile ❑ 4 0 R Residential ❑ R-1 ❑ R-2 ❑ R-3 El 5A El S Storage ❑ S-1 ❑ S-2 ❑ 5B 1 P. U Utility ❑ Specify: M Mixed Use ❑ Specify: S Special Use ❑ Specify: COMPLETE THIS SECTION IF EXISTING BUILDING UNDERGOING RENOVATIONS,ADDITIONS AND/OR CHANGE IN USE Existing Use Group: Proposed Use Group: No "1TTC tr Existing Hazard Index 780 CMR 34): Proposed Hazard Index 780 CMR 34): SECTION 6 BUILDING HEIGHT AND AREA BUILDING AREA EXISTING PROPOSED NEW CONSTRUCTION OFFICE USE ONLY Floor Area per Floor(sf) 0 /K 1 1St 1St 2nd 2nd 3 3 d 'd 4th 4th Total Area (sf) Total Proposed New Construction(sf) Total Height(ft) Total Height ft 7.Wateupply(M.G.L.c.40,§54) 7.1 Flood Zone Information: 7.3 Sewa a isposal System: Public Private ❑ Zone Outside Flood Zone Municipal On site disposal system r __---' Versionl.7 Commercial Buildin: Permit Ma 15,2000 - Departmentus�only Jam+%"� City of Northampton Status of Permit: Building Department Curb Cut/Driveway Permit V■k –1 213 212 Main Street Room 100 Sewer/Septic Availability Water/Well Availability ;,1-'6145 MA 01060 Two Sets of Structural Plans PertioR H�Fj "'�Aphone 413-587-1240 Fax 413-587-1272 Plot/Site Plans N Other Specify APPLICATION TO CONSTRUCT, REPAIR, RENOVATE, CHANGE THE USE OR OCCUPANCY OF, OR DEMOLISH ANY BUILDING OTHER THAN A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address. ,SM C/C�e This section to be completed by office fike4' -h 6.– Map 3 g Lot Unit ',r�p-r ' V`+�i � l ST / Zone Overlay District 1V4 •r ' -* (�- . M' • Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT ` 2.1 Owner of Record: SM ('� C,0 c. &V 6.V/ $ f`12-)51 P�1 G–t -iv o 14 I� I $T sr. , go :44%. Name(Print) `�^M W ` Si. �f , �.+ Current Mailing Address: / CBS— a-kfrti6 Signature /� Telephone 2.2 Authorized Agent: ' W pi' Bw{Va 6'-! Mks P• w�'�- `f� sr •, N 0,l't7t�a,MPro Name(Print) / Current Mailing Address: crt— / Signature X "JAl..Ad L`` Telephone SECTION 3- TIMATED CONSTRUCTION COSTS f 5k- k # 7 /066 , - iK r ''g. — Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1 Building * ^' /61 /'1 (a) Building Permit Fee d 2. Electrical (b) Estimated Total Cost of Construction from (6) 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) 5. Fire Protection q 6. Total =(1 +2+ 3+4+5) $ �1 ` /1. -- Check Number q 36 41/ 06011 t� This Section For Official Use Only Building Permit Number Date Issued Signature: Building Commissioner/Inspector of Buildings Date A File#BP-2014-0139 ?No-AV (N APPLICANT/CONTACT PERSON WRIGHT BUILDERS lam" ADDRESS/PHONE 48 Bates St NORTHAMPTON (413)586-8287(116) PROPERTY LOCATION 126 WEST ST-FACILITIES BUILDING MAP 38B PARCEL 006 001 ZONE SI(100)/WP(6)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out J Fee Paid Typeof Construction: INSTALL REPLACEMENT WINDOWS New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: �_� Owner/Statement or License 16370 `e/G/�J_ 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INF9Z1ATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission _ Permit DPW Storm Water Management Demolitio. Delay "04107 Signature of Built r g Of icial Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. 126 WEST ST-FACILITIES BUILDING BP-2014-0139 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 38B-006 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: windows replaced BUILDING PERMIT Permit# BP-2014-0139 Project# JS-2014-000263 Est. Cost: $202991.00 Fee: $1218.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: WRIGHT BUILDERS 16370 Lot Size(sq. ft.): 9365.40 Owner: SMITH COLLEGE OFFICE OF TREASURER Zoning: SI(100)/WP(6)/ Applicant: WRIGHT BUILDERS AT: 126 WEST ST - FACILITIES BUILDING Applicant Address: Phone: Insurance: 48 Bates St (413) 586-8287 (116) Workers Compensation NORTHAMPTONMA01060 ISSUED ON:8/20/2013 0:00:00 TO PERFORM THE FOLLOWING WORK:INSTALL REPLACEMENT WINDOWS POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 8/20/2013 0:00:00 $1218.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner