Loading...
44-052 (9) �_y .x• 30 West Pomeroy Lane Amherst, MA 01002 Phone: 413-835-5162 POWERHOUSE Email: matt.turcotte @gmail.com Site Information Date Of Test: 11/28/2012____ _ _ Contractor: •aro�""'n-form Sheet-Motif Site Address: 1140 Florence Rd orence, v u 4 Test Performed By: Matt Turcotte Job#: 12-005-d Duct Pressurization Test Results Type of Test Performed: Mid-Construction, total leakage with air handler (6%) Duct System 1 Conditioned Floor Area: 2545 sq ft Duct Flow at 25 Pa: 41 CFM Duct Leakage: 1.61 CFM per 100 sq ft of conditioned floor area TEST RESULT : PASS Duct System 2 (if applicable) Conditioned Floor Area: N/A sq ft Duct Flow at 25 Pa: N/A CFM Duct Leakage: N/A CFM per 100 sq ft of conditioned floor area TEST RESULT: N/A Notes on Area Tested and/or Testing Conditions: System serves 1st floor floor of the front part of the house. 2009 IECC Minimum Requirements, per Section 403.2.2 Mid-Construction Test, total leakage without air handler< 4 CFM per 100 sq ft of conditioned floor area Mid-Construction Test, total leakage with air handler< 6 CFM per 100 sq ft of conditioned floor area Post-Construction Test, leakage to the outdoors < 8 CFM per 100 sq ft of conditioned floor area Post-Construction Test, total leakage < 12 CFM per 100 sq ft of conditioned floor area t9•- c) (s- eg- / 140 West Street West Hatfield, MA 01088 413-427-1416 Cell Aaron Morin Sheetmetal 413-247-9924 Fax asmsheetmetal @live.com RECEIVED FalK NOV 0 2012 DEPT-O C : NOFiTr( i _ ' To: From: Aaron Morin Fax Pages: Phone -Date: //qoF(1 - J r -C-690W t M5 -�f�� f= "So0X/6,04011 r-ci dea r- — � �il�� o C /51S /— -- 31`b4 Z e acs - o el-. q og'oC P1z doaf C �,�cl e-?tso -- o 1 O / % eel= 2// 767 y 0 T — o r- C a 5 /14s- -ems -- A,. The Commonwealth of Massachusetts . Department of Industrial Accidents. . T.L-,.--.....-.7,-- -:4!". . • Office of Investigations , 600 Washington Street Boston,MA 02111 .1.... _ „....t, , goi www.mass.govidia Workers' Compensation Insurance Affidavit:Bufiders/Contractors/ElectriciansfPlumbers Applicant Information Please Print Legibly Name(Business/Organization/Individual): gWir-OY\ Mon k ,Sive- 17)t-e-j-dr%--I , Address: ' j /0 (z.leS T Se,--1— City/State/Zip: tie-5 i- Ak, - td,....-LII 0/0F;Vhone#: 973 ---- c-f7---Os Are you an employer?Check the appropriate box: , - - Type of project(required): 1.DI-am a employer with 1 4. 0 I am a general contractor and I 6. 0 New construction employees(full and/or part-time).* have hired the sub-contractors /.El I am-a-sole-proprietoror-partner-- _ listed on_the_attached sheet 7. 0 Remodeling ship and have no employees These sub-contractors have 8. D Demolition working for me in any capacity employees and have workers' 9. 0 Building addition [No-workers comp.insnianCe conip.Ihs-ifit-Er---------:---- - requireJ 5. 0 We are-a-corporation:and its 10.0 Electdcal repairs or additions_ 3.0 I air a homeowner doing all work officers have exercrsed-leir MD Plumbing repairs or additions - –---- myself [No workers'-comp. . right--cifeinP'1°11-1)41:-IVIGL -- - 12 0 Roof repairs insurance required j t c.152,§1(4),and we have no . employees..[NO workers' 13.210ther att.ti..../e-ik _ c6rap:ins-thrice lecitiiied.] - • *Any applicant that checks box#1 must arso fill out the section belovishowirig theirriiiiiikers—'-ecImpessation policy information. t Flomeowners who submit this affidavit indicating they are doing all work and then hire outside contractors.must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether ornot those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. lain an employer that is providing workers'compensation insurance for my employees.-Below is the policy and job site -- information. — r Insurance Company Name: 4,...-i-etwt, (--- 6f- ...,: e..,_.../21,4,1---„,if ,..7--71 f.. co . Policy#or Self-ins Lic.#: tvi C /0 C3 Cc! Expiration Date 3 Z-13 tr--y Job Site Address: //qa Redr--(7C.,e__e ....„ City/State/Zip: /07, ()to Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required-under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a.fine of up to$250.00 a day against the_violator:Buadvised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. .- . . Ida hereby certi nd the pains and pe allies ofperjury that the information provided above is true and correct —- Signature: /7-9- 6-/ -- • Date: Phone#: (-03-9-Y7-057So /c79:14-----q1-3 4 ----7------- -/zif l 6 Official use only Do not write in this area,to be completed by city or town officiaL • City or Town: Permit/License# - - –Issuing Authority(circle one): - - I.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other . __. Contact Person: Phone#: _ . .4*N. I I !Nit I la I I w I us A 'e".2-Cb 2 CD Saw C1) CeU) e, LiAZ [Ai § >1•LI — 2 o 4ri& w en— C1.5) 01 e X S E=( F1.4 I c,■.) * vv. c•- 11 I 7r-rr I NØ.4L f(oupol.0/....REGisTRAPt xo OJtilVtlOiS d z o c:$ in co a' z E to so • ca, sAt„,)t— co -•■• U-I co S uice LIJ (1) 0 zcnw =ui ca %Jr,. i < z E CO O O .7t.' JS 8 C4 (• S o cc -(7). w g—■ cT- x _l (l) l• a! 1.11 0 mcW to 0 UJ EL 1-4=c Z u- W Ct°11) O 0 1A1 cri o ca • Z b.4 z 0 f*. AI30 West Pomeroy Lane Amherst, MA 01002 Phone: 413-835-5162 POWERHOUSE Email: matt.turcotte@gmail.com Site Information Date Of Test: 10/29/2012 Contractor: Aaron Morin Sheet Metal Site Address: 1140 Florence Rd Florence, MA 01062 Test Performed By: Matt Turcotte Job#: 12-005-d Duct Pressurization Test Results Type of Test Performed: Mid-Construction, total leakage with air handler (6%) Duct System 1 Conditioned Floor Area: 2310 sq ft Duct Flow at 25 Pa: 46 CFM Duct Leakage: 1.99 CFM per 100 sq ft of conditioned floor area TEST RESULT : PASS Duct System 2 (if applicable) Conditioned Floor Area: N/A sq ft Duct Flow at 25 Pa: N/A CFM Duct Leakage: N/A CFM per 100 sq ft of conditioned floor area TEST RESULT: N/A Notes on Area Tested and/or Testing Conditions: ys- System serves 2nd & 3rd floor of the front part of the house. 2009 IECC Minimum Requirements, per Section 403.2.2 Mid-Construction Test, total leakage without air handler< 4 CFM per 100 sq ft of conditioned floor area Mid-Construction Test, total leakage with air handler< 6 CFM per 100 sq ft of conditioned floor area Post-Construction Test, leakage to the outdoors < 8 CFM per 100 sq ft of conditioned floor area Post-Construction Test, total leakage < 12 CFM per 100 sq ft of conditioned floor area k" "�#F" a ._c a,.� 4s�aa2£✓ ""NN""""R a..sm .��..o:a' �� T��.3., .�..Y:;� MIA for 1 1 Prepared By Aaron Morin ASM Sheet Metal 11-12-2012 RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Webb Air e+ Florence Map Wobum,MA 01801 11-12-2012 Page 25 Room Load Summary Reports System #2 Room Load Summary Htg Htg Run Run Clg Cig Clg Zone Clg Air Room Area Sens Nom Duct Duct Sens Lat Nom Adj Adj Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM Fact CFM CFM --Zone 1-- 11 Master 308 7,969 104 3-5 541 4,834 345 221 1.25 277 221 Bedroom 12 Master Bath 133 2,066 27 1-4 393 748 81 34 1.16 40 34 13 Master Closet 56 1,637 21 1-4 387 737 81 34 1.35 46 34 14 Hall 232 3,119 41 1-6 518 2,222 135 102 1.25 127 102 15 Bedroom 210 7,422 97 2-5 571 3,400 345 156 1.00 156 156 Nwest 16 2nd Floor Bath 60 322 4 1-4 78 149 0 7 1.00 7 7 17 Bedroom 210 4,924 64 1-5 568 1,691 230 77 1.00 77 77 Northeast 18 Closet 48 115 2 1-0 0 71 0 3 1.00 3 3 Zone 1 Subtotal 1257 27,574 361 13,852 1,217 634 732 634 ---Zone 2--- 19 Third Floor 756 14,147 185 3-6 585 7,523 474 344 1.16 399 344 Open Are Zone 2 Subtotal 756 14,147 185 7,523 474 344 399 344 System 2 Totals 2013 41,721 546 21,375 1,691 979 1,131 979 Main Trunk Size: 14x12 in. System #2 Cooling System Summary Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 1.922 93%/7% 21,375 1,691 23,066 Recommended: 2.313 77%123% 21,375 6,385 27,760 Monday,November 12,2012 RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Webb Air Florence Malt Woburn,MA 01801 11-12-2012 Page 24 Room Load Summary Reports System #1 Room Load Summary Htg Htg Run Run Clg Clg Clg Zone Clg Air Room Area Sens Nom Duct Duct Sens Lat Nom Adj Adj Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM Fact CFM CFM ---Zone 1--- 1 Mud Room 190 4,781 63 1-4 533 1,015 113 46 1.00 46 46 2 Dining 198 7,198 94 2-6 463 3,970 264 182 1.05 191 182 3 Kitchen 294 707 9 2-5 626 3,726 300 171 1.00 171 171 4 Pantry 80 1,850 24 1-4 251 479 54 22 1.00 22 22 5 Sunporch 288 14,770 193 4-6 558 9,574 539 438 1.05 460 438 Zone 1 Subtotal 1050 29,306 383 18,764 1,270 859 890 859 ---Zone 2-- 6 Family Room 504 8,920 117 3-5 611 5,460 243 250 1.00 250 250 7 Hall 232 6,208 81 1-4 563 1,072 226 49 1.00 49 49 8 Bedroom 196 7,780 102 2-5 503 2,993 275 137 1.00 137 137 Nwest 9 Bedroom 238 5,360 70 1-5 455 1,356 183 62 1.00 62 62 Neast 10 C loset 56 134 2 0-0 0 0 0 0 1.00 0 0 Zone 2 Subtotal 1226 28,402 372 10,881 927 498 498 498 System 1 Totals 2276 57,708 755 29,645 2,197 1,358 1,389 1,358 Main Trunk Size: 18x14 in. System#1 Cooling System Summary Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 2.654 93%/7% 29,645 2,197 31,842 Recommended: 3.208 77%/23% 29,645 8,855 38,500 Monday,November 12,2012 RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Webb Air lik Florence Mall Wobum,MA 01801 11-12-2012 Page 23 Detailed Room Loads 19.Third Floor Open Are Room Length: 36.0 Feet System Number: 2 Room Width: 21.0 Feet Zone Number: 2 Area: 756.0 Square Feet Supply Air: 344 CFM Ceiling Height: 7.0 Feet Required Vent. Air: 0 CFM Volume: 5,292.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 3 %of Supply: 0 % Runout Air: 115 CFM Actual Summer Ventilation Air: 0 CFM Runout Duct Size: 6 Inches % of Supply: 0 Runout Air Velocity: 585 Feet/Minute Actual Winter Infiltration Air: 57 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 29 CFM alloc. Actual Loss: 0.219 In.wg/100 Ft. Item Area -U- Htg Sen. Clg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain S-WALL-12H 21 X 8 133 0.060 4.6 614 1.6 0 212 N -WALL-12H 21 X 8 133 0.060 4.6 614 1.6 0 212 W-WALL-12H 36 X 5 180 0.060 4.6 832 1.6 0 287 E-WALL-12H 36 X 5 180 0.060 4.6 832 1.6 0 287 S-GLAS-3D 2-P 0-0 S-1 0%S 35 0.361 27.8 973 32.6 0 1,141 N -GLAS-3D 2-P 0-0 S-1 100%S 35 0.361 27.8 973 19.6 0 686 E-ROOF-18F DARK 36 X 11 396 0.035 2.7 1,067 1.6 0 651 W-ROOF-18F DARK 36 X 11 396 0.035 2.7 1,067 1.6 0 651 Subtotals for structure: 1,488 6,972 0 4,127 Infiltration: Winter: 57.3, Summer: 28.6: 70 68.814 4,817 10.271 474 719 Ductwork: 0.200 2,358 0.200 0 1,254 Active People: 230 lat/per, 300 sen/per: 0 0 0 Inactive People: 150 lat/per, 250 sen/per: 0 0 0 Appliances: 0 400 Lighting: 300 1,023 Sensible Gain Total: 7,523 Temperature Swing Multiplier: X1.00 Room Totals: 14,147 474 7,523 Monday,November 12,2012 RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Webb Air 10 Florence Mall Wobum,MA 01801 11-12-2012 Page 22 Detailed Room Loads 18. Closet Room Length: 8.0 Feet System Number: 2 Room Width: 6.0 Feet Zone Number: 1 Area: 48.0 Square Feet Supply Air: 3 CFM Ceiling Height: 8.0 Feet Required Vent. Air: 0 CFM Volume: 384.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 1 % of Supply: 0 % Runout Air: 3 CFM Actual Summer Ventilation Air: 0 CFM Runout Duct Size: 0 Inches % of Supply: 0 % Runout Air Velocity: 0* Feet/Minute Actual Winter Infiltration Air: 0 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 0 CFM alloc. Actual Loss: 0.000 In.wg/100 Ft. *Runout velocity constraints were not met due to duct schedule limitations. Item Area -U- Htg Sen. Clg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain UP-CEIL-16H DARK 8 X 6 48 0.026 2.0 96 1.2 0 59 Subtotals for structure: 48 96 0 59 Infiltration: Winter: 0.0, Summer: 0.0: 0 0.000 0 0.000 0 0 Ductwork: 0.200 19 0.200 0 12 Active People: 230 lat/per, 300 sen/per: 0 0 0 Inactive People: 150 lat/per, 250 sen/per: 0 0 0 Appliances: 0 0 Lighting: 0 0 Sensible Gain Total: 71 Temperature Swing Multiplier: X1.00 Room Totals: 115 0 71 Monday,November 12,2012 6 RHVAC-Residential&Light Commercial HVAC Loads Program 114. Elite Software Development,Inc. Webb Air 0 Florence Mall Wobum,MA 01801 11-12-2012 Page 21 Detailed Room Loads 17. Bedroom Northeast Room Length: 14.0 Feet System Number: 2 Room Width: 15.0 Feet Zone Number: 1 Area: 210.0 Square Feet Supply Air: 77 CFM Ceiling Height: 8.0 Feet Required Vent. Air: 0 CFM Volume: 1,680.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 1 % of Supply: 0 % Runout Air: 77 CFM Actual Summer Ventilation Air: 0 CFM Runout Duct Size: 5 Inches %of Supply: 0 % Runout Air Velocity: 568 Feet/Minute Actual Winter Infiltration Air: 28 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 14 CFM alloc. Actual Loss: 0.267 In.wg/100 Ft. Item Area -U- Htg Sen. CIg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain N -WALL-12H 15 X 8 86 0.060 4.6 397 1.6 0 137 N -GLAS-3D 2-P 0-0 S-1 100%S 17 0.361 27.8 473 19.6 0 333 N -GLAS-3D 2-P 0-0 S-1 100%S 17 0.361 27.8 473 19.6 0 333 UP-CEIL-16H DARK 14 X 15 210 0.026 2.0 420 1.2 0 257 Subtotals for structure: 330 1,763 0 1,060 Infiltration: Winter: 27.8, Summer: 13.9: 34 68.824 2,340 10.265 230 349 Ductwork: 0.200 821 0.200 0 282 Active People: 230 lat/per, 300 sen/per: 0 0 0 Inactive People: 150 lat/per, 250 sen/per: 0 0 0 Appliances: 0 0 Lighting: 0 Sensible Gain Total: 1,691 Temperature Swing Multiplier: X1.00 Room Totals: 4,924 230 1,691 Monday,November 12,2012 RHVAC-Residential&Light Commercial HVAC Loads Program 1141, Elite Software Development,Inc. Webb Air 0 Florence Mall Wobum,MA 01801 11-12-2012 Page 20 Detailed Room Loads 16. 2nd Floor Bath Room Length: 15.0 Feet System Number: 2 Room Width: 4.0 Feet Zone Number: 1 Area: 60.0 Square Feet Supply Air: 7 CFM Ceiling Height: 8.0 Feet Required Vent. Air: 0 CFM Volume: 480.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 1 %of Supply: 0 % Runout Air: 7 CFM Actual Summer Ventilation Air: 0 CFM Runout Duct Size: 4 Inches % of Supply: 0 % Runout Air Velocity: 78* Feet/Minute Actual Winter Infiltration Air: 0 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 0 CFM alloc. Actual Loss: 0.008 In.wg/100 Ft. *Runout velocity constraints were not met due to duct schedule limitations. Item Area -U- Htg Sen. Clg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain N-WALL-12H 4 X 8 32 0.060 4.6 148 1.6 0 51 UP-CEIL-16H DARK 15 X 4 60 0.026 2.0 120 1.2 0 73 Subtotals for structure: 92 268 0 124 Infiltration: Winter: 0.0, Summer: 0.0: 0 0.000 0 0.000 0 0 Ductwork: 0.200 54 0.200 0 25 Active People: 230 lat/per, 300 sen/per: 0 0 0 Inactive People: 150 lat/per, 250 sen/per: 0 0 0 Appliances: 0 0 Lighting: 0 0 Sensible Gain Total: 149 Temperature Swing Multiplier: X1.00 Room Totals: 322 0 149 Monday,November 12,2012 RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Webb Air Florence Mall Wobum,MA 01801 11-12-2012 Page 19 Detailed Room Loads 15. Bedroom Nwest Room Length: 14.0 Feet System Number: 2 Room Width: 15.0 Feet Zone Number: 1 Area: 210.0 Square Feet Supply Air: 156 CFM Ceiling Height: 8.0 Feet Required Vent. Air: 0 CFM Volume: 1,680.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 2 % of Supply: 0 % Runout Air: 78 CFM Actual Summer Ventilation Air: 0 CFM Runout Duct Size: 5 Inches % of Supply: 0 % Runout Air Velocity: 571 Feet/Minute Actual Winter Infiltration Air: 42 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 21 CFM alloc. Actual Loss: 0.269 In.wg/100 Ft. Item Area -U- Htg Sen. CIg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain W-WALL-12H 15 X 8 103 0.060 4.6 476 1.6 0 164 N -WALL-12H 14 X 8 78 0.060 4.6 360 1.6 0 124 W-GLAS-3D 2-P 0-0 S-1 0%S 17 0.361 27.8 473 64.6 0 1,098 N -GLAS-3D 2-P 0-0 S-1 100%S 17 0.361 27.8 473 19.6 0 333 N -GLAS-3D 2-P 0-0 S-1 100%S 17 0.361 27.8 473 19.6 0 333 UP-CEIL-16H DARK 14 X 15 210 0.026 2.0 420 1.2 0 257 Subtotals for structure: 442 2,675 0 2,309 Infiltration: Winter: 41.7, Summer: 20.9: 51 68.824 3,510 10.275 345 524 Ductwork: 0.200 1,237 0.200 0 567 Active People: 230 lat/per, 300 sen/per: 0 0 0 Inactive People: 150 lat/per, 250 sen/per: 0 0 0 Appliances: 0 0 Lighting: 0 0 Sensible Gain Total: 3,400 Temperature Swing Multiplier: X1.00 Room Totals: 7,422 345 3,400 Monday,November 12,2012 RHVAC-Residential&Light Commercial HVAC Loads Program itt Elite Software Development,Inc. Webb Air P Florence Mall Woburn,MA 01801 11-12-2012 Page 18 Detailed Room Loads 14. Hall Room Length: 29.0 Feet System Number: 2 Room Width: 8.0 Feet Zone Number: 1 Area: 232.0 Square Feet Supply Air: 102 CFM Ceiling Height: 8.0 Feet Required Vent. Air: 0 CFM Volume: 1,856.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 1 % of Supply: 0 % Runout Air: 102 CFM Actual Summer Ventilation Air: 0 CFM Runout Duct Size: 6 Inches % of Supply: 0 % Runout Air Velocity: 518 Feet/Minute Actual Winter Infiltration Air: 16 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 8 CFM alloc. Actual Loss: 0.173 In.wg/100 Ft. Item Area -U- Htg Sen. Clg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain W-WALL-12H 8 X 8 44 0.060 4.6 203 1.6 0 70 W-GLAS-3D 2-P 0-0 S-1 0%S 20 0.361 27.8 556 64.6 0 1,292 UP-CEIL-16H DARK 29 X 8 232 0.026 2.0 464 1.2 0 284 Subtotals for structure: 296 1,223 0 1,646 Infiltration: Winter: 16.4, Summer: 8.2: 20 68.800 1,376 10.300 135 206 Ductwork: 0.200 520 0.200 0 370 Active People: 230 lat/per, 300 sen/per: 0 0 0 Inactive People: 150 lat/per, 250 sen/per: 0 0 0 Appliances: 0 0 Lighting: 0 0 Sensible Gain Total: 2,222 Temperature Swing Multiplier: X1.00 Room Totals: 3,119 135 2,222 Monday.November 12.2012 I RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Webb Air Florence Mall Woburn,MA 01801 11-12-2012 Page 17 Detailed Room Loads 13. Master Closet Room Length: 14.0 Feet System Number: 2 Room Width: 4.0 Feet Zone Number: 1 Area: 56.0 Square Feet Supply Air: 34 CFM Ceiling Height: 8.0 Feet Required Vent. Air: 0 CFM Volume: 448.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 1 % of Supply: 0 % Runout Air: 34 CFM Actual Summer Ventilation Air: 0 CFM Runout Duct Size: 4 Inches % of Supply: 0 % Runout Air Velocity: 387* Feet/Minute Actual Winter Infiltration Air: 10 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 5 CFM alloc. Actual Loss: 0.171 In.wg/100 Ft. *Runout velocity constraints were not met due to duct schedule limitations. Item Area -U- Htg Sen. Clg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain S-WALL-12H 4 X 8 20 0.060 4.6 92 1.6 0 32 S-GLAS-3D 2-P 0-0 S-1 0%S 12 0.361 27.8 334 32.6 0 391 UP-CEIL-16H DARK 14 X 4 56 0.026 2.0 112 1.2 0 68 Subtotals for structure: 88 538 0 491 Infiltration: Winter: 9.8, Summer: 4.9: 12 68.833 826 10.250 81 123 Ductwork: 0.200 273 0.200 0 123 Active People: 230 lat/per, 300 sen/per: 0 0 0 Inactive People: 150 lat/per, 250 sen/per: 0 0 0 Appliances: 0 0 0 Lighting: Sensible Gain Total: X 737 737 Temperature Swing Multiplier: 0 Room Totals: 1,637 81 737 Monday,November 12,2012 RHVAC-Residential&Light Commercial HVAC Loads Program ,. Elite Software Development,Inc. t10 Florence Mall Webb Air 12 Wobum,MA 01801 11-12-2012 Page 16 Detailed Room Loads 12. Master Bath Room Length: 14.0 Feet System Number: 2 Room Width: 9.5 Feet Zone Number: 1 Area: 133.0 Square Feet Supply Air: 34 CFM Ceiling Height: 8.0 Feet Required Vent. Air: 0 CFM Volume: 1,064.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 1 %of Supply: 0 % Runout Air: 34 CFM Actual Summer Ventilation Air: 0 CFM Runout Duct Size: 4 Inches % of Supply: 0 % Runout Air Velocity: 393* Feet/Minute Actual Winter Infiltration Air: 10 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 5 CFM alloc. Actual Loss: 0.176 In.wg/100 Ft. *Runout velocity constraints were not met due to duct schedule limitations. Item Area -U- Htg Sen. Clg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain S -WALL-12H 9.5 X 8 64 0.060 4.6 296 1.6 0 102 S-GLAS-3D 2-P 0-3 S-1 100%S 12 0.361 27.8 334 19.6 0 235 UP-CEIL-16H DARK 14 X 9.5 133 0.026 2.0 266 1.2 0 163 Subtotals for structure: 209 896 0 500 Infiltration: Winter: 9.8, Summer: 4.9: 12 68.833 826 10.250 81 123 Ductwork: 0.200 344 0.200 0 125 Active People: 230 lat/per, 300 sen/per: 0 0 0 Inactive People: 150 lat/per, 250 sen/per: 0 0 0 Appliances: 0 0 Lighting: 0 Sensible Gain Total: 748 Temperature Swing Multiplier: X1.00 Room Totals: 2,066 81 748 Monday,November 12,2012 RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Webb Air Florence Mall Wobum,MA 01801 11-12-2012 Page 15 Detailed Room Loads 11. Master Bedroom Room Length: 22.0 Feet System Number: 2 Room Width: 14.0 Feet Zone Number: 1 Area: 308.0 Square Feet Supply Air: 221 CFM Ceiling Height: 8.0 Feet Required Vent. Air: 0 CFM Volume: 2,464.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 3 % of Supply: 0 % Runout Air: 74 CFM Actual Summer Ventilation Air: 0 CFM Runout Duct Size: 5 Inches % of Supply: 0 % Runout Air Velocity: 541 Feet/Minute Actual Winter Infiltration Air: 42 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 21 CFM alloc. Actual Loss: 0.242 In.wg/100 Ft. Item Area -U- Htg Sen. Clg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain W-WALL-12H 14 X 8 78 0.060 4.6 360 1.6 0 124 S-WALL-12H 22 X 8 159 0.060 4.6 735 1.6 0 254 W-GLAS-3D 2-P 0-0 S-1 0%S 17 0.361 27.8 473 64.6 0 1,098 W-GLAS-3D 2-P 0-0 S-1 0%S 17 0.361 27.8 473 64.6 0 1,098 S-GLAS-3D 2-P 0-0 S-1 0%S 17 0.361 27.8 473 32.6 0 554 UP-CEIL-16H DARK 22 X 14 308 0.026 2.0 617 1.2 0 376 Subtotals for structure: 596 3,131 0 3,504 Infiltration: Winter: 41.7, Summer: 20.9: 51 68.824 3,510 10.275 345 524 Ductwork: 0.200 1,328 0.200 0 806 Active People: 230 lat/per, 300 sen/per: 0 0 0 Inactive People: 150 lat/per, 250 sen/per: 0 0 0 Appliances: 0 0 Lighting: 0 0 Sensible Gain Total: 4,834 Temperature Swing Multiplier: X1.00 Room Totals: 7,969 345 4,834 Monday,November 12,2012 E RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Webb Air Florence Mall Woburn,MA 01801 11-12-2012 Page 14 Detailed Room Loads 10. Closet Room Length: 8.0 Feet System Number: 1 Room Width: 7.0 Feet Zone Number: 2 Area: 56.0 Square Feet Supply Air: 0 CFM Ceiling Height: 9.0 Feet Required Vent. Air: 0 CFM Volume: 504.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 0 % of Supply: 0 % Runout Air: 0 CFM Actual Summer Ventilation Air: 0 CFM Runout Duct Size: 0 Inches % of Supply: 0 % Runout Air Velocity: 0* Feet/Minute Actual Winter Infiltration Air: 0 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 0 CFM alloc. Actual Loss: 0.000 In.wg/100 Ft. *Runout velocity constraints were not met due to duct schedule limitations. Item Area -U- Htg Sen. Clg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain FLOOR-19D 7 X 8 56 0.052 2.0 112 0.0 0 0 Subtotals for structure: 56 112 0 0 Infiltration: Winter: 0.0, Summer: 0.0: 0 0.000 0 0.000 0 0 Ductwork: 0.200 22 0.200 0 0 Active People: 230 lat/per, 300 sen/per: 0 0 0 Inactive People: 150 lat/per, 250 sen/per: 0 0 0 Appliances: 0 0 Lighting: 0 0 Sensible Gain Total: 0 Temperature Swing Multiplier: X1.00 Room Totals: 134 0 0 Monday,November 12,2012 RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Webb Air lik Florence Mall Woburn,MA 01801 11-12-2012 Page 13 Detailed Room Loads 9. Bedroom Neast Room Length: 17.0 Feet System Number: 1 Room Width: 14.0 Feet Zone Number: 62 CFM Area: 238.0 Square Feet Supply Air: Ceiling Height: 9.0 Feet Required Vent. Air: 0 CFM Volume: 2,142.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 1 % of Supply: 0 % Runout Air: 62 CFM Actual Summer Ventilation Air: 0 CFM Runout Duct Size: 5 Inches % of Supply: 0 % Runout Air Velocity: 455 Feet/Minute Actual Winter Infiltration Air: 30 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 13 CFM alloc. Actual Loss: 0.172 In.wg/100 Ft. Item Area -U- Htg Sen. Clg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain N -WALL-12H 17 X 9 119 0.060 4.6 550 1.5 0 176 N -GLAS-3D 2-P 0-0 S-1 100%S 17 0.361 27.8 473 19.2 0 326 N -GLAS-3D 2-P 0-0 S-1 100%S 17 0.361 27.8 473 19.2 0 326 FLOOR-19D 14 X 17 238 0.052 2.0 476 0.0 0 0 Subtotals for structure: 391 1,972 0 828 Infiltration: Winter: 29.7, Summer: 13.2: 34 73.382 2,495 8.882 183 302 Ductwork: 0.200 893 0.200 0 226 Active People: 230 lat/per, 300 sen/per: 0 0 0 Inactive People: 150 lat/per, 250 sen/per: 0 0 0 Appliances: 0 0 Lighting: 0 - - - - 356 Sensible Gain Total: 1X,,356 Temperature Swing Multiplier: - Room Totals: 5,360 183 1,356 Monday,November 12,2012 RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Webb Air lik Florence Mall Woburn,MA 01801 11-12-2012 Page 12 Detailed Room Loads 8. Bedroom Nwest Room Length: 14.0 Feet System Number: 1 Room Width: 14.0 Feet Zone Number: 2 Area: 196.0 Square Feet Supply Air: 137 CFM Ceiling Height: 9.0 Feet Required Vent. Air: 0 CFM Volume: 1,764.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 2 % of Supply: 0 % Runout Air: 69 CFM Actual Summer Ventilation Air: 0 CFM Runout Duct Size: 5 Inches % of Supply: 0 % Runout Air Velocity: 503 Feet/Minute Actual Winter Infiltration Air: 45 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 20 CFM alloc. Actual Loss: 0.209 In.wg/100 Ft. Item Area -U- Htg Sen. Clg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain N -WALL-12H 14 X 9 92 0.060 4.6 425 1.5 0 136 W-WALL-12H 14 X 9 109 0.060 4.6 504 1.5 0 161 N -GLAS-3D 2-P 0-0 S-1 100%S 17 0.361 27.8 473 19.2 0 326 N -GLAS-3D 2-P 0-0 S-1 100%S 17 0.361 27.8 473 19.2 0 326 W-GLAS-3D 2-P 0-0 S-1 0%S 17 0.361 27.8 473 64.2 0 1,091 FLOOR-19D 14 X 14 196 0.052 2.0 392 0.0 0 0 Subtotals for structure: 448 2,740 0 2,040 Infiltration: Winter: 44.5, Summer: 19.8: 51 73.392 3,743 8.902 275 454 Ductwork: 0.200 1,297 0.200 0 499 Active People: 230 lat/per, 300 sen/per: 0 0 0 Inactive People: 150 lat/per, 250 sen/per: 0 0 0 Appliances: 0 0 Lighting: 0 0 Sensible Gain Total: 2,993 Temperature Swing Multiplier: X1.00 Room Totals: 7,780 275 2,993 Monday,November 12,2012 Anommommosummummv RHVAC-Residential&Light Commercial HVAC Loads Program ^ , Elite Software Development,Inc. Webb Air *ito Florence Mall Wobum,MA 01801 11-12-2012 Page 11 Detailed Room Loads 7. Hall Room Length: 29.0 Feet System Number: 1 Room Width: 8.0 Feet Zone Number: 2 Area: 232.0 Square Feet Supply Air: 49 CFM Ceiling Height: 9.0 Feet Required Vent. Air: 0 CFM Volume: 2,088.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 1 % of Supply: 0 % Runout Air: 49 CFM Actual Summer Ventilation Air: 0 CFM Runout Duct Size: 4 Inches %of Supply: 0 Runout Air Velocity: 563 Feet/Minute Actual Winter Infiltration Air: 37 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 16 CFM alloc. Actual Loss: 0.357 In.wg/100 Ft. Item Area -U- Htg Sen. Clg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain W-WALL-12H 8 X 9 30 0.060 4.6 139 1.5 0 44 W-DOOR-10D 6 X 7 42 0.460 35.4 1,488 11.3 0 475 FLOOR-19D 8 X 29 232 0.052 2.0 464 0.0 0 0 Subtotals for structure: 304 2,091 0 519 Infiltration: Winter: 36.7, Summer: 16.3: 42 73.381 3,082 8.905 226 374 Ductwork: 0.200 1,035 0.200 0 179 Active People: 230 lat/per, 300 sen/per: 0 0 0 Inactive People: 150 lat/per, 250 sen/per: 0 0 0 Appliances: 0 0 Lighting: 0 0 Sensible Gain Total: 1,072 Temperature Swing Multiplier: X1.00 Room Totals: 6,208 226 1,072 Monday,November 12.2012 AP RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Webb Air lk Florence Mali Wobum,MA 01801 11-12-2012 Page 10 Detailed Room Loads 6. Family Room Room Length: 36.0 Feet System Number: 1 Room Width: 14.0 Feet Zone Number: 2 Area: 504.0 Square Feet Supply Air: 250 CFM Ceiling Height: 9.0 Feet Required Vent. Air: 0 CFM Volume: 4,536.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 3 % of Supply: 0 % Runout Air: 83 CFM Actual Summer Ventilation Air: 0 CFM Runout Duct Size: 5 Inches % of Supply: 0 % Runout Air Velocity: 611 Feet/Minute Actual Winter Infiltration Air: 39 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 17 CFM alloc. Actual Loss: 0.307 In.wg/100 Ft. Item Area -U- Htg Sen. Clg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain W-WALL-12H 14 X 9 111 0.060 4.6 513 1.5 0 164 S-WALL-12H 36 X 9 294 0.060 4.6 1,358 1.5 0 434 W-GLAS-3D 2-P 0-0 S-1 0%S 15 0.361 27.8 417 64.2 0 963 S-GLAS-3D 2-P 0-0 S-1 0%S 15 0.361 27.8 417 32.2 0 483 S-GLAS-3D 2-P 0-0 S-1 0%S 15 0.361 27.8 417 32.2 0 483 FLOOR-19D 14 X 36 504 0.0.52 2.0 1,009 0.0 0 0 Subtotals for structure: 954 4,131 0 2,527 Infiltration: Winter: 39.3, Summer: 17.5: 45 73.378 3,302 8.889 243 400 Ductwork: 0.200 1,487 0.200 0 910 Active People: 230 lat/per, 300 sen/per: 0 0 0 Inactive People: 150 lat/per, 250 sen/per: 0 0 0 Appliances: 0 600 Lighting: 300 1,023 Sensible Gain Total: 5,460 Temperature Swing Multiplier: X1.00 Room Totals: 8,920 243 5,460 Monday,November 12,2012 4, RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Webb Air Florence Mall Wobum,MA 01801 11-12-2012 Page 9 Detailed Room Loads 5. Sunporch Room Length: 24.0 Feet System Number: 1 Room Width: 12.0 Feet Zone Number: 1 Area: 288.0 Square Feet Supply Air: 438 CFM Ceiling Height: 9.0 Feet Required Vent. Air: 0 CFM Volume: 2,592.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 4 % of Supply: 0 % Runout Air: 110 CFM Actual Summer Ventilation Air: 0 CFM Runout Duct Size: 6 Inches °A) of Supply: 0 Runout Air Velocity: 558 Feet/Minute Actual Winter Infiltration Air: 87 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 39 CFM alloc. Actual Loss: 0.199 In.wg/100 Ft. Item Area -U- Htg Sen. Clg Latent Sen. Description Quantity Value H TM Loss HTM Gain Gain E-WALL-12H 12 X 9 8 0.060 4.6 37 1.5 0 12 S-WALL-12H 24 X 9 216 0.060 4.6 998 1.5 0 319 E-GLAS-3D 2-P 0-0 S-1 0%S 25 0.361 27.8 695 64.2 0 1,605 E-GLAS-3D 2-P 0-0 S-1 0%S 25 0.361 27.8 695 64.2 0 1,605 E-GLAS-3D 2-P 0-0 S-1 0%S 25 0.361 27.8 695 64.2 0 1,605 E-GLAS-3D 2-P 0-0 S-1 0%S 25 0.361 27.8 695 64.2 0 1,605 UP-CEIL-16H DARK 24 X 12 288 0.026 2.0 577 1.2 0 337 FLOOR-19D 12 X 24 288 0.052 2.0 577 0.0 0 0 Subtotals for structure: 900 4,969 0 7,088 Infiltration: Winter: 87.3, Summer: 38.8: 100 73.390 7,339 8.900 539 890 Ductwork: 0.200 2,462 0.200 0 1,596 Active People: 230 Iat/per, 300 sen/per: 0 0 0 Inactive People: 150 lat/per, 250 sen/per: 0 0 0 Appliances: 0 0 Lighting: 0 0 Sensible Gain Total: 9,574 Temperature Swing Multiplier: X1.00 Room Totals: 14,770 539 9,574 Monday,November 12,2012 RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Webb Air Florence Mall Wobum,MA 01801 11-12-2012 Page 8 Detailed Room Loads 4. Pantry Room Length: 8.0 Feet System Number: 1 Room Width: 10.0 Feet Zone Number: 1 Area: 80.0 Square Feet Supply Air: 22 CFM Ceiling Height: 9.0 Feet Required Vent. Air: 0 CFM Volume: 720.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 1 % of Supply: 0 % Runout Air: 22 CFM Actual Summer Ventilation Air: 0 CFM Runout Duct Size: 4 Inches % of Supply: 0 % Runout Air Velocity: 251* Feet/Minute Actual Winter Infiltration Air: 9 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 4 CFM alloc. Actual Loss: 0.073 In.wg/100 Ft. *Runout velocity constraints were not met due to duct schedule limitations. Item Area -U- Htg Sen. Clg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain N-WALL-12H 10 X 9 80 0.060 4.6 370 1.5 0 118 N -GLAS-3D 2-P 0-0 S-1 100%S 10 0.361 27.8 278 19.2 0 192 FLOOR-19D 10 X 8 80 0.052 2.0 160 0.0 0 0 Subtotals for structure: 170 808 0 310 Infiltration: Winter: 8.7, Summer: 3.9: 10 73.400 734 8.900 54 89 Ductwork: 0.200 308 0.200 0 80 Active People: 230 lat/per, 300 sen/per: 0 0 0 Inactive People: 150 lat/per, 250 sen/per: 0 0 0 Appliances: 0 0 Lighting: 0 0 Sensible Gain Total: 479 Temperature Swing Multiplier: X1.00 Room Totals: 1,850 54 479 Monday,November 12,2012 RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Webb Air Florence Mall Woburn,MA 01801 11-12-2012 Page 7 Detailed Room Loads 3. Kitchen Room Length: 24.5 Feet System Number: 1 Room Width: 12.0 Feet Zone Number: 1 Area: 294.0 Square Feet Supply Air: 171 CFM Ceiling Height: 9.0 Feet Required Vent. Air: 0 CFM Volume: 2,646.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 2 % of Supply: 0 % Runout Air: 85 CFM Actual Summer Ventilation Air: 0 CFM Runout Duct Size: 5 Inches % of Supply: 0 % Runout Air Velocity: 626 Feet/Minute Actual Winter Infiltration Air: 0 CFM alloc. Design Loss: 0.100 ln.wg/100 Ft. Actual Summer Infiltration Air: 0 CFM alloc. Actual Loss: 0.322 In.wg/100 Ft. Item Area -U- Htg Sen. Clg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain FLOOR-19D 12 X 24.5 294 0.052 2.0 589 0.0 0 Subtotals for structure: 294 589 0 0 Infiltration: Winter: 0.0, Summer: 0.0: 0 0.000 0 0.000 0 0 Ductwork: 0.200 118 0.200 0 621 Active People: 230 lat/per, 300 sen/per: 0 0 0 Inactive People: 150 lat/per, 250 sen/per: 0 0 0 Appliances: 300 1,400 Lighting: 500 1,705 Sensible Gain Total: 3,726 Temperature Swing Multiplier: X1.00 Room Totals: 707 300 3,726 Monday,November 12,2012 RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Webb Air 4. Florence Mall Wobum,MA 01801 11-12-2012 Page 6 Detailed Room Loads 2. Dining Room Length: 12.0 Feet System Number: 1 Room Width: 16.5 Feet Zone Number: 1 Area: 198.0 Square Feet Supply Air: 182 CFM Ceiling Height: 9.0 Feet Required Vent. Air: 0 CFM Volume: 1,782.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 2 % of Supply: 0 % Runout Air: 91 CFM Actual Summer Ventilation Air: 0 CFM Runout Duct Size: 6 Inches % of Supply: 0 % Runout Air Velocity: 463 Feet/Minute Actual Winter Infiltration Air: 43 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 19 CFM alloc. Actual Loss: 0.138 In.wg/100 Ft. Item Area -U- Htg Sen. Clg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain N -WALL-12H 16.5 X 9 149 0.060 4.6 688 1.5 0 220 E-WALL-12H 6 X 9 5 0.060 4.6 23 1.5 0 7 E-DOOR-10F 3 X 7 21 0.320 24.6 517 7.9 0 165 E-GLAS-3D 2-P 0-0 S-1 0%S 28 0.361 27.8 778 64.2 0 1,798 FLOOR-19D 16.5 X 12 198 0.0.52 2.0 396 0.0 0 0 Subtotals for structure: 401 2,402 0 2,190 Infiltration: Winter: 42.8, Summer: 19.0: 49 73.388 3,596 8.898 264 436 Ductwork: 0.200 1,200 0.200 0 662 Active People: 230 lat/per, 300 sen/per: 0 0 0 Inactive People: 150 lat/per, 250 sen/per: 0 0 0 Appliances: 0 0_ 682 Lighting: 200 Sensible Gain Total: 3,970 Temperature Swing Multiplier: X1.00 Room Totals: 7,198 264 3,970 Monday,November 12,2012 g RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Webb Air lk Florence Mall Wobum,MA 01801 11-12-2012 Page 5 Detailed Room Loads 1. Mud Room Room Length: 19.0 Feet System Number: 1 Room Width: 10.0 Feet Zone Number: 1 Area: 190.0 Square Feet Supply Air: 46 CFM Ceiling Height: 9.0 Feet Required Vent. Air: 0 CFM Volume: 1,710.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 1 % of Supply: 0 % Runout Air: 46 CFM Actual Summer Ventilation Air: 0 CFM Runout Duct Size: 4 Inches % of Supply: 0 % Runout Air Velocity: 533 Feet/Minute Actual Winter Infiltration Air: 18 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 8 CFM alloc. Actual Loss: 0.320 In.wg/100 Ft. Item Area -U- Htg Sen. CIg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain E-WALL-12H 19 X 9 171 0.060 4.6 790 1.5 0 252 S-WALL-12H 10 X 9 69 0.060 4.6 319 1.5 0 102 S-DOOR-11A 3 X 7 21 0.590 45.4 954 14.5 0 305 FLOOR-19D 10 X 19 190 0.052 2.0 380 0.0 0 0 Subtotals for structure: 451 2,443 0 659 Infiltration: Winter: 18.3, Summer: 8.1: 21 73.381 1,541 8.905 113 187 Ductwork: 0.200 797 0.200 0 169 Active People: 230 lat/per, 300 sen/per: 0 0 0 Inactive People: 150 lat/per, 250 sen/per: 0 0 0 Appliances: 0 0 Lighting: 0 0 Sensible Gain Total: 1,015 Temperature Swing Multiplier: X1.00 Room Totals: 4,781 113 1,015 Monday,November 12,2012 RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Webb Air lkit Florence Mall Woburn,MA 01801 11-12-2012 Page 4 Total Building Summary Loads Component Area Sen. Lat. Sen. Total Description Quan Loss Gain Gain Gain 3D Window Double Pane Low Emit Wood Frame 518 14,406 0 21,659 21,659 10D Door Wood Solid Core 42 1,488 0 475 475 10F Door Wood Solid Core& Metal Storm 21 517 0 165 165 11A Door Metal Fiberglass Core 21 954 0 305 305 12H Wall R-19 + 1/2"Gypsum Board(R-0.5) 2,743 12,673 0 4,201 4,201 16H Ceiling R-38 Insulation 1,545 3,092 0 1,874 1,874 18F Roof+Ceil R-30 Batts(2x10"rafter) 792 2,134 0 1,302 1,302 19D Floor Over Basement/Encl Crawl Hardwood + R-19 2,276 4,555 0 0 0 Subtotals for structure: 7,958 39,819 0 29,981 29,981 Active People: 0 0 0 0 0 Inactive People: 0 0 0 0 0 Appliances: 0 0 300 2,400 2,700 Lighting: 1,300 0 0 4,433 4,433 Ductwork: 0 16,573 0 8,506 8,506 Infiltration: Winter CFM: 511.9, Summer CFM: 238.9 602 43,037 3,588 5,700 9,288 Ventilation: Winter CFM: 0.0, Summer CFM: 0.0 0 0 0 0 0 Sensible Gain Total: 51,020 Temperature Swing Multiplier: X1.00 ......._.-.......___._.-_._ .. ... Building Load Totals: 99,429 3,888 51,020 54,908 Check Figures Total Building Supply CFM: 2,336 CFM per square foot: 0.545 Square feet of room area: 4,289 Square feet per ton: 776.761 Building Loads Total heating required with outside air: 99,429 Btuh 99.429 MBH Total sensible gain: 51,020 Btuh 93 ok Total latent gain: 3,888 Btuh 7 ok Total cooling required with outside air: 54,908 Btuh 4.576 Tons (based on sensible+latent) 5.522 Tons (based on 77% sensible capacity) Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Monday,November 12,2012 9 Elite Software Development,Inc. RHVAC-Residential&Light Commercial HVAC Loads Program Webb Air ,.! Florence Mall Wobum,MA 01801 11-12-2012 Page 3 Miscellaneous Project Data Project File Name: MORIN FLORENCE MALL System Input Data Outdoor Outdoor Indoor Indoor Grains ---System 1--- Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference Winter: -5 N/A N/A 72 N/A Summer: 93 71 50% 72 21 ---System 2--- Winter: -5 N/A N/A 72 N/A Summer: 93 71 50% 70 24 External Overhangs No. Projection Offset No Projection Offset 1 3 1 6 0 0 2 5 0 7 0 0 3 4 0.5 8 0 0 4 0 0 9 0 0 5 0 0 10 0 0 Duct Sizing Inputs Runouts Main Trunk Duct Material: Flexible Duct Galvanized Steel Roughness Factor: 0.010000 0.000300 Pressure Drop: 0.1000 In.wg/100 Ft. 0.1000 In.wg/100 Ft. Minimum Velocity: 450.0 Ft./Minute 650.0 Ft./Minute Maximum Velocity: 750.0 Ft./Minute 900.0 Ft./Minute Minimum Height: 0 Inches 0 Inches Maximum Height: 0 Inches 0 Inches Outside Air Data Winter Summer Infiltration: 0.857 AC/Hr 0.400 AC/Hr Volume of Conditioned Space: X 35832 Cu.Ft. X 35832 Cu.Ft. 30,714 Cu.Ft./Hr 14,333 Cu.Ft./Hr X 0.0167 X 0.0167 Total Building Infiltration: 512 CFM 239 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration &Ventilation Sensible Gain Multiplier: 22.93 = (1.10 X 0.993 X 21.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 13.89 = (0.68 X 0.993 X 20.58 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 84.07 = (1.10 X 0.993 X 77.00 Winter Temp. Difference) ---System 2--- Infiltration &Ventilation Sensible Gain Multiplier: 25.11 = (1.10 X 0.993 X 23.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 16.53 = (0.68 X 0.993 X 24.49 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 84.07 = (1.10 X 0.993 X 77.00 Winter Temp. Difference) Monday,November 12,2012 RHVAC-Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Webb Air Florence Mall Wobum,MA 01801 11-12-2012 Page 2 Project Summary Project: Florence Mall Company: ASM Sheet Metal Client: Representative: Aaron Morin Address: Address: City: City: Phone: Phone: Fax: Fax: Comment: Design Data Project Name: Florence Mall Reference City: Northampton, Massachusetts Daily Temperature Range: Medium Latitude: 42 Degrees Elevation: 205 Feet Altitude Factor: 0.993 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference Winter: -5 N/A N/A 72 N/A Summer: 93 71 50% 72 21 Check Figures Total Building Supply CFM: 2,336 CFM per square foot: 0.545 Square feet of room area: 4,289 Square feet per ton: 776.761 Building Loads Total heating required with outside air: 99,429 Btuh 99.429 MBH Total sensible gain: 51,020 Btuh 93 % Total latent gain: 3,888 Btuh 7 % Total cooling required with outside air: 54,908 Btuh 4.576 Tons (based on sensible+ latent) 5.522 Tons(based on 77% sensible capacity) Notes Calculations are based or> 7t edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Monday,November 12,2012 FL MALL HVAC ORFNCE ANALYSIS for ! �I Prepared By: Aaron Morin ASM Sheet Metal 11-12-2012 INSURANCE COVERAGE: I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L.Ch. 112 Yes❑ No❑ If you have checked Yes, indicate the type of coverage by checking the appropriate box below: A liability insurance policy ❑ Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER: I am aware that the licensee rinnc not have,the insurance coverage required by Chapter 112 of the Massachusetts General Laws, and that my signature on this permit application waivPsthis requirement. Check One Only Owner ❑ Agent ❑ Signature of Owner or Owner's Agent By checking this boxD,I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Duct inspection required prior to insulation installation: YES NO ProgreQs Ingrectinnc Date f`ommente Final Incpertinn Date Cnmments Type of License: By ❑Master Title ❑ Master-Restricted City/Town ❑Journeyperson Signature of Licensee Permit# ❑Jou rneyperson-Restricted Fee$ License Number: Check at www macs gnvMp( Inspector Signature of Permit Approval Commonwealth of Massachusetts City Of Northampton Date: /! a6, —�� Sheet Metal Permit Permit# 5172 —/ 3'9`i Estimated Job Cost: $ /¶' <3'60,00 Permit Fee: $ 4as Plans Submitted: YES NO Plans Reviewed: YES NO Business License# S3 3 Applicant License# Business Information: ,/ Property Owner/Job Location Information: Name: 4,24,1Hot k.,,S l ice /v ( Name: • a4A 5--(teolu,„ Pe a S � 55 y Street: /C(O(r/L°57` s74 1 Street: /l R/o -iCKo re it cam_ eL City/Town: (A/e571- City/Town: `Ra.(i✓44 �p Telephone: go —C/?7 /ci Telephone: Photo I.D. required/Copy of Photo I.D. attached: YES LNO Staff Initial J-1 /M-1-unrestricted license J-2/M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft./2-stories or less Residential: 1-2 family [/ Multi-family Condo/Townhouses Other Commercial: Office Retail Industrial Educational Institutional Other Square Footage: under 10,000 sq. ft. over 10,000 sq. ft. Number of Stories: Sheet metal work to completed: New Work: Renovation: HVAC Metal Watershed Roofing Kitchen Exhaust System Metal Chimney/Vents Air Balancing Provide detailed description of work to be done: /1evy c0nita/.eA-e____ sp/' .s - • �. �Zelq i - Fees with Building Permit: $25.00 Residential, $50.00 Commercial. Fees for jobs without a Building Permit$6.00 per$1000 Minimum fees for jobs without Building Permit$50.00 Residential, $100.00 Commercial File#SM-2013-0029 APPLICANT/CONTACT PERSON AARON MORIN � ADDRESS/PHONE 140 WEST ST (413)247-0550 Q c,� PROPERTY LOCATION 1140 FLORENCE RD t 5cre MAP 44 PARCEL 052 001 ZONE THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out )L/-�J6 ( 016 Fee Paid / 7 6 'F/ Typeof Construction: 2 NEW COMPLETE SPLIT-SYS W/DUCTWORK&ZONING New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 533 3 sets of Plans/Plot Plan THE FOLLO . ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON IN 0' o - ION PRESENTED: pproved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER: § Intermediate Project: Site Plan AND/OR Special Permit with Site Plan Major Project: Site Plan AND/OR Special Permit with Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee t fro I lm Str et Commission Permit DPW Storm Water Management /41110 - --/7/ . e of B 'd ng wig Date Note:Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact the Office of Planning&Development for more information. 1140 FLORENCE RD SM-2013-0029 COMMONWEALTH OF MASSACHUSETTS T_ CITY OF NORTHAMPTON GIS#: 8443_ " TaH, Map__-- 44 , �'' Block= osl t � SHEETMETAL PERMIT Lot: 00 * �_,,� Permit: SHEETMETAL \r£RCenTEHP� 1Category: SHEETMETAL Permit# SM-2013-0029 PERMISSION IS HEREBY GRANTED TO: Pro ect# JS-2012-000377 Contractor: License: Est.Cost:: Ct t $18,800.00 Expires: Fee Charged:$25.00 AARON MORIN Sheetmetal-533 10/28/2013 Balance Due:$.00 Owner: SHEEHAN JOHN G #of Fixtures: Applicant: AARON MORIN DigSafe# AT: 1140 FLORENCE RD UseGroup rConstClass ISSUED ON: 04-Apr-2013 AMENDED ON: EXPIRES ON: TO PERFORM THE FOLLOWING WORK: 2 NEW COMPLETE SPLIT-SYS W/DUCTWORK&ZONING THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fee Type: Receipt No: Date Paid: Check No: Amount: Sheetmetal REC-2013-002072 26-Nov-12 1470 $25.00 Inspection Type: Inspector: Date Inspected: Date Signed Off: Status: FINAL Charles Miller 04-Apr-13 FULL COMPLY 212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,Email:lhasbrouck @northamptonma.gov GeoTMS®2013 Des Lauriers Municipal Solutions,Inc.