11A-010 (3) igp.;; NORTHWIND 111 NFRC DOUBLE HUNG h National Fenestration Vinyl frame, Double glazed, Rating Council® Low E coating (e= 0.034, S2) CERTIFIED 11/12 NVP -K -14 -00154 -00001 ENERGY PERFORMANCE RATINGS U- Factor (U.S. /I -P) Solar Heat Gain Coefficient 0•33 0•28 ADDITIONAL PERFORMANCE RATINGS Visible Transmittance 0.53 Manufacturer stipulates that these ratings conform to applicable NFRC procedures for determining whole product performance. eci c product s ie. NFRC does ratings ot recommend any product and doenvironmental o warrant conditions h il� of any product for any specific use. Consult manufacturer's literature for other product perforrnance Information. www.nfrc.orq Reedy 1 :41 a 2 . � e _� t Northampton /14-- 0 lO 9:41am KeyBeam® 4.600d loft kmBeamEngine 4.600y Materials Database 1393 Member Data Description: Member Type: Beam Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC /IRC Live Load: 40 PLF Deflection Criteria: L/360 live, L/240 total 1.250" max. LL Dead Load: 10 PLF Deck Connection: Nailed Member Weight: 14.0 PLF Filename: KYB1 Other Loads Type Trib. Other Dead (Description) Side Begin End Width Start End Start End Category Replacement Uniform (PSF) Top 0' 0.00" 13' 0.00" 15' 0.00" 30 10 Live II . - j . : 11' / 0 1300 / 13 0 0 / Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF #3 /Stud 2x or 4x End -Grain (650psi) 3.500" 1.500" 3857# -- 2 13' 0.000" Wall SPF #3 /Stud 2x or 4x End -Grain (650psi) 3.500" 1.500" 3857# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 2827# 1030# 2 2827# 1030# Design spans 12' 6.750" Product: 1- 3/4x9 -1/2 VERSA -LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS Connect members with 2 rows of 16d common nails at 12.0" oc NOTE: Nails must be applied from both sides Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 12112.'# 21774.'# 55% 6.5' Total Load D +L Shear 3371.# 9476.# 35% 0.23' Total Load D +L Max. Reaction 3857.# 11944.# 32% 0' Total Load D +L TL Deflection 0.4586" 0.6281" L/328 6.5' Total Load D +L LL Deflection 0.3361" 0.4187" L/448 6.5' Total Load L Control: LL Deflection DOLs: Live =100% Snow=115% Roof= 125% Wind =160% Design assumes a repetitive member use increase in bending stress: 4 % All product names are trademarks of their respective owners ter" Copyright (C)1987 -2012 by Keymark Enterprises, LLC. ALL RIGHTS RESERVED. "Passing is defined as when the member, floor joist, beam or girder. shown on this drawing meets applicable design criteria for Loads, Loading Conditions. and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer's specifications.