Loading...
29-103 (2) so'C , ®Boise Cascade Double 1 -3/4" x 9 -1/2" VERSA -LAM® 2.0 3100 SP Designs \FB02 1 span I No cantilevers 10/12 slope Tuesday, October 23, 2012 BC CALC® Design Report - US 01 -00 -00 OCS Build 1757 File Name: BC CALC Project Job Name: Stevensville Corp Description: Designs \FB02 Address: Specifier: City, State, Zip: , Designer: Clayton Customer: Fleury Company: Boise Code reports: ESR -1040 Misc: Connection Diagram Disclosure fit b d Completeness and accuracy of input must be verified by anyone who would rely on output as evidence of suitability for 4 • • • /� particular application. Output here based � \ on building code - accepted design c properties and analysis methods. Installation of BOISE engineered wood • • products must be in accordance with / /, current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call a minimum = 2" c = 5 -1/2" (800)232 -0788 before installation. b minimum = 3" d = 24" BC CALC ®, BC FRAMER® ,AJSTM', Member has no side loads. ALLJOIST ®, BC RIM BOARDTM', BCI® , Connectors are: 16d Sinker Nails BOISE GLULAMTM', SIMPLE FRAMING SYSTEM® , VERSA -LAM ®, VERSA -RIM PLUS® , VERSA -RIM ®, VERSA - STRAND®, VERSA -STUD® are trademarks of Boise Cascade Wood Products L.L.C. , Y Page 2 of 2 PDF created with pdfFactory trial version www.pdffactory.com -/03x7 ,tea ® Boise Cascade Double 1 -3/4" x 9-1/2" VERSA -LAM® 2.0 3100 SP Designs1FB02 1 span I No cantilevers ( 0/12 slope Tuesday, October 23, 2012 BC CALC® Design Report - US 01 -00 -00 OCS Build 1757 File Name: BC CALC Project Job Name: Stevensville Corp Description: Designs \FB02 Address: Specifier: City, State, Zip: , Designer: Clayton Customer: Fleury Company: Boise Code reports: ESR -1040 Misc: s w s .j. * 4 w � a 4 � s � w w v v i w = v d� + . et # + T w � j � 4 4 'v dr �s s ® . s 1 1 , i 7 v a v �r '* v. 1 ® v v. r. v 1 v: 4 4 1- a 1 a v 4 Y 4 v t* t v 4. J 16 -06-00 I/ BO B1 Total Horizontal Product Length = 16 -06 -00 Reaction Summary (Down / Uplift) ( Ibs ) Bearing Live Dead Snow Wind Roof Live B0, 3 -1/2" 330 / 0 861 / 0 B1, 3-1/2" 330 / 0 861 / 0 Live Dead Snow Wind Roof Live OCS Load Summary Tag Description Load Type Ref. Start End 100% 90% 115% 160% 125% 1 Standard Load Unf. Area (Ib/ft^2) L 00 -00 -00 16 -06 -00 40 15 01 -00 -00 2 WALL Unf. Lin. (lb/ft) L 00 -00 -00 16 -06 -00 0 80 n/a Controls Summary Value %Allowable Duration Case Location Disclosure Pos. Moment 4,644 ft-Ibs 33.3% 100% 1 08 -03 -00 Completeness and accuracy of input must End Shear 1,035 Ibs 16.4% 100% 1 01 -01 -00 be verified by anyone who would rely on Total Load Defl. U448 (0.43 ") 53.6% n/a 1 08 -03 -00 output as evidence of suitability for Live Load Defl. L/1,615 (0.119 ") 29.7% n/a 2 08 -03-00 particular building application. Output sere based on building code - accepted d design Max Defl. 0.43" 86% n/a 1 08 -03-00 properties and analysis methods. Span / Depth 20.3 n/a n/a 0 00 -00 -00 Installation of BOISE engineered wood products must be in accordance with current Installation Guide and applicable % Allow % Allow building codes. To obtain Installation Guide Bearing Supports Dim. (L x W) Value Support Member Material or ask questions, please calf BO Post 3 -1/2" x 3 -1/2" 1,191 Ibs n/a 13% Unspecified (800)232 -0788 before installation. B1 Post 3 -1/2" x 3-1/2" 1,191 Ibs n/a 13% Unspecified BC CALC®, BC FRAMER ®,AJST"", ALLJOIST ®, BC RIM BOARDTM', BCI® , Notes BOISE GLULAMTM' SIMPLE FRAMING n meets Code minimum (U240) Total load deflection criteria. P , V RSA RIM®, ,VERSA -RIM Design ( ) PLUS®,VERSA -RIM ®, Design meets User specified ([1480) Live load deflection criteria. VERSA - STRAND®, VERSA -STUD® are Design meets arbitrary (0.5 ") Maximum total load deflection criteria. trademarks of Boise Cascade Wood Calculations assume member is fully laterally braced. Products L.L.C. Al se i 7 - --9 F -------) Page 1 of 2 PDF created with pdfFactory trial version www.pdffactory.com