Loading...
38B-131 exposes fiberglass insulation and finds black insulation, which is dirt filter out of the air moving through the insulation. 780 CMR R601.2 for vapor retarders and Table N1102.4.2 for air sealing requirements. 26. Unvented attic assemblies. Hot roofs are allowed, but have specific requirements 780 CMR R806.4. 27. Deck ledgers and post must be appropriately attached, bolts or lags. 780 CMR R502.2.2.1 Note: ThruLoks are engineered for post attachment supporting a railing. 28. Smoke and CO detectors as required. 780 CMR R314 and R315. 29. Closets beneath stair which have doors must be drywalled with %2 ". 780 CMR R302.7 Relevant items must be submitted to the building department for approvals before inspections and or CO can be signed. Other items are intended to avoid costly issues at inspections. Feel free to call if you have any questions. My telephone number is 587 -1240 and office hours are Monday through Friday, 8:30 am to 4:30 pm, excepting we close for walk -ins at 12:00 noon on Wee nes. ays. My emai address is: cmiller Thank you for your cooperation on these mat . 411101 i Chuck Miller City of Northampton Assistant Commissioner and Zoning Enforcement 12. Hazardous glazing locations, within 24" of a door, or within 60" of a stair, or across from hot tubs, spas, bathtubs within 60" if not 60" above the walking surface, and other locations. 780 CMR R308.4 13. Windows over 72" above grade with the opening less than 24 above the finished floor shall meet the 4" sphere rule. Order restrictors. 780 CMR R612.2 14. Egress and emergency escape requirements shall be strictly met. a. Basements, habitable attics, and all sleeping rooms require emergency escape. 780 CMR R310 b. Windows within 44" of floor, DH 3.3 sqft min window size, Casement 20 "x41" exception 5 sqft at 1 floor. Minimum clear opening 20 "x24" or 24 "x20 ". 780 CMR R310.1.1 c. Two doors remote as possible at the normal level of travel, opening measured from the face of the slab to the stop with door at 90 degrees, one 32" and one 28" minimum 78" high. 780 CMR R311.2 d. Landing at each door 36" out and the width of the door minimum 36 ", maximum step 7 3 /" from the top of the threshold and only in- swinging doors. 780 CMR R311.3 15. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9 ", maximum riser 8 % ", maximum overall variance for the run is 3/8 ", 4" sphere rule on risers except where the total rise is 30" or less 780 CMR R311.7.4.3 Exception, 4 3/8" on balustrade, 6" in the triangle. Graspable rail 1 'A" minimum and 2" maximum rail, height minimum 34" maximum 38 ", required for 4 or more risers. Landing to landing constitutes a new run. Minimum 6'8" ceiling height from nosing. 780 CMR R311.7. 16. Guards 36" minimum height above walking surface, a bench is a walking surface, required for more than 30" above floor or grade within 36 ", 4" sphere rule. 780 CMR R312.1. 17. Educate the plumber and electrician about maximum notch and hole sizes, and placement. 780 CMR R502.8 and R602.6. In bearing studs holes not larger than 40% of a stud no closer than 5/8 to the edge, In interior non - bearing studs holes not larger than 60% of a stud no closer than 5/8 to the edge, in bearing walls if more than 50% of a plate is cut or notched a 1 %Z 16ga. strap must extend a minimum of 6" past the cut both directions and be nailed with 8 -10d per side, or holes in joist are a maximum 1/3 the depth not closer than 2" from the top or bottom. Notches are different. 18. Dryer duct transition is limited to 8' of aluminum flex and must be exposed. 780 CMR M1502.4.3 19. Dryer duct maximum equivalent length is 25' or per manufacturer's specs. 780 CMR M1502.4.4.1, no screwed connections. 20. Markup air is required for any exhaust hood of 400 CFM or more. 780 CMR M1503.4 21. Fireplaces require all combustion air be provided from the exterior and below the firebox, duct work maintaining 1" clearance for 5' from the duct outlet for all fireplaces 22. Fire and draft stopping shall be completed before rough inspection. 780 CMR R302. 23. Ignition barriers in place before final. 780 CMR R316. 24. Energy aspects shall comply with the stretch energy code. 780 CMR Appendix 115AA or 2009 IECC. a. An initial HERS evaluation is required including insulation levels anticipated. b. A final HERS evaluation confirming code requirements have been met including duct testing. c. Energy information including mechanical equipment posted on the electric panel. d. Remodeling and Additions can be completed in accordance with IECC 2009 with Energy Star Building Option Package. 25. Vapor retarders. Although these are still in the code have exceptions, one must understand that there is a difference between a vapor retarder or barrier and an air barrier. An air barrier is intended to stop air flow (convection) a vapor retarder or barrier is intended to stop molecular moisture transfer (diffusion). A vapor retarder or barrier is effective even if there are some holes or gaps, however an air barrier has to be absolute and complete. If air can leak through an electrical device or through a crack it follows the path of least resistance and carries 99% of the moisture in a structure. This is evident every time one 1 City of Northampton Massachusetts . ,r � i 4 # 1 DEPARTMENT OF BUILDING INSPECTIONS l y : �, - 21 Main Street • Municipal Building Northampton, MA 01060 '' j \ ' INSPECTOR John Joyce April 11, 2012 78 Timber Drive East Longmeadow, MA 01028 Subject Location: 22 East Street Map Block: 38B -131 Mr. Joyce, These are a few items which will need to be included; 1. All none prescriptive members, LVL and I- Joist, require stamped engineering. (wet stamp not required) 2. #*footing rebar must be bonded. 3. CO detector added in the Entry. 4. If there isn't a CO on the 2 " floor it must be added. 5. Windows 72" AFG with an opening within 24" AFF must have a restrictor to meet 4" sphere rule. 6. Exterior wall insulation should be R -20, absolute air sealing is required, and windows must be Energy Star. See the 2009 IECC for additional mandatory energy measures. As of August 4 2011 the 8 Edition MA code is the 2009 IRC with MA amendments. In the following are some generic requirements which seem to be problematic. This is not a substitute for purchasing and reading the MA codes. 1. Structures shall conform to 780 CMR 8 Edition 1 and 2 family building codes with MA amendments. 2. Grading plan for structures being constructed required. 780 CMR R401.3 for drainage requirements. 3. A basement drainage system is required in all basements 780 CMR R405.2.3. except those in group I soils (table R405.1) 4. Foundations that retain earth and enclose interior space require damp proofing 780 CMR R406.1. 5. Ceiling joist are intended to prevent spread, once raised above the wall plate they become rafters ties and may require up sizing of rafters and increased nailing for example with a 4" slope 8 -16nd common are required at each connection. 780 CMR R802.3.1. 6. Steel straps over the ridge or 1x4 minimum collar ties are required 4' OC in the upper 1 / 3rd 780 CMR R802.3.1 7. Ridge boards must be the full depth of the cut. 780 CMR R802.3. 8. A complete window and header schedule is required. 780 CMR Table R502.5 for header sizing and number of jack studs required. 9. All framing materials which are not code prescriptive must have stamped engineering. a. LVLs b. I -joist and or Floor Truss c. Roof truss 10. A braced wall plan identifying appropriate braced wall areas and braced wall method being used. 780 CMR 602.10. a. Garage corners and large corner window /door layout may require special solutions. b. All corners must be appropriately attached to the foundation. 11. Ceiling heights minimum 7' for habitable spaces, 6'8" for bathrooms includes tub /shower area if a shower head is used, 6'8" for basements, 6'4" at beams /ducts. 780 CMR R305.1. MA amended 200 I Energy Efficiency Certifi Insulation Rating R -Value Ceiling / Roof 38.00 Wall 19.00 Floor / Foundation 30.00 Ductwork (unconditioned spaces): - Glass & Door Rating U- Factor SHGC Window 0.27 Door 0.19 NA Heating & Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments: Circulating Service Hot Water Systems: • Circulating service hot water pipes are insulated to R -2. O Circulating service hot water systems include an automatic or accessible manual switch to turn off the circulating pump when the system is not in use. Heating and Cooling Piping Insulation: • HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to R - 3. Swimming Pools: u Heated swimming pools have an on /off heater switch. • Pool heaters operating on natural gas or LPG have an electronic pilot light. D Timer switches on pool heaters and pumps are present. Exceptions: Where public health standards require continuous pump operation. Where pumps operate within solar- and /or waste- heat - recovery systems. D Heated swimming pools have a cover on or at the water surface. For pools heated over 90 degrees F (32 degrees C) the cover has a minimum insulation value of R -12. Exceptions: Covers are not required when 60% of the heating energy is from site - recovered energy or solar energy source. Lighting Requirements: Li A minimum of 50 percent of the lamps in permanently installed lighting fixtures can be categorized as one of the following: (a) Compact fluorescent (b) T -8 or smaller diameter linear fluorescent (c) 40 lumens per watt for lamp wattage <= 15 (d) 50 lumens per watt for lamp wattage > 15 and <= 40 (e) 60 lumens per watt for lamp wattage > 40 Other Requirements: ❑ Snow- and ice- melting systems with energy supplied from the service to a building shall include automatic controls capable of shutting off the system when a) the pavement temperature is above 50 degrees F, b) no precipitation is falling, and c) the outdoor temperature is above 40 degrees F (a manual shutoff control is also permitted to satisfy requirement 'e). Certificate: A permanent certificate is provided on or in the electrical distribution panel listing the predominant insulation R- values; window U- factors; type and efficiency of space- conditioning and water heating equipment. The certificate does not cover or obstruct the visibility of the circuit directory label, service disconnect label or other required labels. NOTES TO FIELD: (Building Department Use Only) Project Title: Holden Addition Report date: 03/20/12 Data filename: Untitled.rck Page 4 of 4 LI Wood - burning fireplaces have gasketed doors and outdoor combustion air. LI Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. Air Sealing and Insulation: u Building envelope air tightness and insulation installation complies by either 1) a post rough -in blower door test result of less than 7 ACH at 50 pascals OR 2) the following items have been satisfied: (a) Air barriers and thermal barrier: Installed on outside of air - permeable insulation and breaks or joints in the air barrier are filled or repaired. (b) Ceiling /attic: Air barrier in any dropped ceiling /soffit is substantially aligned with insulation and any gaps are sealed. (c) Above -grade walls: Insulation is installed in substantial contact and continuous alignment with the building envelope air barrier. (d) Floors: Air barrier is installed at any exposed edge of insulation. (e) Plumbing and wiring: Insulation is placed between outside and pipes. Batt insulation is cut to fit around wiring and plumbing, or sprayed /blown insulation extends behind piping and wiring. (f) Corners, headers, narrow framing cavities, and rim joists are insulated. (9) Shower/tub on exterior wall: Insulation exists between showers /tubs and exterior wall. Sunrooms: • Sunrooms that are thermally isolated from the building envelope have a maximum fenestration U- factor of 0.50 and the maximum skylight U- factor of 0.75. New windows and doors separating the sunroom from conditioned space meet the building thermal envelope requirements. Materials Identification and Installation: Li Materials and equipment are installed in accordance with the manufacturer's installation instructions. (] Materials and equipment are identified so that compliance can be determined. u Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. ❑ Insulation R- values and glazing U- factors are clearly marked on the building plans or specifications. Duct Insulation: LI Supply ducts in attics are insulated to a minimum of R -8. All other ducts in unconditioned spaces or outside the building envelope are insulated to at least R -6. Duct Construction and Testing: Li Building framing cavities are not used as supply ducts. u All joints and seams of air ducts, air handlers, filter boxes, and building cavities used as return ducts are substantially airtight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Tapes, mastics, and fasteners are rated UL 181A or UL 181B and are labeled according to the duct construction. Metal duct connections with equipment and /or fittings are mechanically fastened. Crimp joints for round metal ducts have a contact lap of at least 1 1/2 inches and are fastened with a minimum of three equally spaced sheet -metal screws. Exceptions: Joint and seams covered with spray polyurethane foam. Where a partially inaccessible duct connection exists, mechanical fasteners can be equally spaced on the exposed portion of the joint so as to prevent a hinge effect. Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). u Duct tightness test has been performed and meets one of the following test criteria: (1) Postconstruction leakage to outdoors test: Less than or equal to 8 cfm per 100 ft2 of conditioned floor area. (2) Postconstruction total leakage test (including air handler enclosure): Less than or equal to 12 cfm per 100 ft2. ( Rough -in total leakage test with air handler installed: Less than or equal to 6 cfm per 100 ft2 of conditioned floor area. (4) Rough -in total leakage test without air handler installed: Less than or equal to 4 cfm per 100 ft2 of conditioned floor area. Temperature Controls: u Where the primary heating system is a forced air - furnace, at least one programmable thermostat is installed to control the primary heating system and has set - points initialized at 70 degree F for the heating cycle and 78 degree F for the cooling cycle. ❑ Heat pumps having supplementary electric- resistance heat have controls that prevent supplemental heat operation when the compressor can meet the heating load. Heating and Cooling Equipment Sizing: • Additional requirements for equipment sizing are included by an inspection for compliance with the International Residential Code. Li For systems serving multiple dwelling units documentation has been submitted demonstrating compliance with 2009 IECC Commercial Building Mechanical and /or Service Water Heating (Sections 503 and 504). Project Title: Holden Addition Report date: 03/20/12 Data filename: Untitled.rck Page 3 of 4 0 REScheck Software Version 4.4.3 Inspection Checklist Energy Code: 2009 IECC Location: Northampton, Massachusetts Construction Type: Single Family Project Type: Addition /Alteration Heating Degree Days: 6404 Climate Zone: 5 Ceilings: ❑ Ceiling 1: Flat Ceiling or Scissor Truss, R -38.0 cavity insulation Comments: Above - Grade Walls: ❑ Wall 1: Wood Frame, 16" o.c., R -19.0 cavity insulation Comments: Windows: ❑ Window 1: Vinyl Frame:Double Pane with Low -E, U- factor: 0.270 For windows without labeled U- factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1: Glass, U- factor: 0.190 Comments: ❑ Door 2: Glass, U- factor: 0.190 Comments: ❑ Door 3: Glass, U- factor: 0.190 Comments: Floors: ❑ Floor 1: All -Wood Joist/Truss:Over Unconditioned Space, R -30.0 cavity insulation Comments: Floor insulation is installed in permanent contact with the underside of the subfloor decking. Crawl Space Walls: ❑ Crawl 1: Solid Concrete or Masonry Exemption: Framing cavity filled with insulation. Comments: Air Leakage: ❑ Joints (including rim joist junctions), attic access openings, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed with caulk, gasketed, weatherstripped or otherwise sealed with an air barrier material, suitable film or solid material. ❑ Air barrier and sealing exists on common walls between dwelling units, on exterior walls behind tubs /showers, and in openings between window/door jambs and framing. ❑ Recessed lights in the building thermal envelope are 1) type IC rated and ASTM E283 labeled and 2) sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. ❑ Access doors separating conditioned from unconditioned space are weather- stripped and insulated (without insulation compression or damage) to at least the level of insulation on the surrounding surfaces. Where loose fill insulation exists, a baffle or retainer is installed to maintain insulation application. Project Title: Holden Addition Report date: 03/20/12 Data filename: Untitled.rck Page 2 of 4 C1 REScheck Software Version 4i.4.3 Comp Cert Project Title: Holden Addition / -- Energy Code: 2009 IECC Location: Northampton, Massachusetts Construction Type: Single Family Project Type: Addition /Alteration Heating Degree Days: 6404 Climate Zone: 5 Construction Site: Owner /Agent: Designer /Contractor: 22 Easty Strreet John Joyce S and D Architects Northampton, MA 01060 FTF 78 Timber Drive East Longmeadow, MA 01028 4135190716 Compliance: Passes Compliance: 14.4% Better Than Code Maximum UA: 90 Your UA: 77 The % Better or Worse Than Code index reflects how close to compliance the house is based on code trade -off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Gross Cavity Cont. Glazing UA Assembly Area or R -Value R -Value or Door Perimeter U- Factor Crawl 1: Solid Concrete or Masonry - -- - -- - -- -- -- Exemption: Framing cavity filled with insulation. Floor 1: All -Wood Joist/Truss:Over Unconditioned Space 28830 0.0 10 ye.0 Wall 1: Wood Frame, 16" o.c. 640 0.0 31 Window 1: Vinyl Frame:Double Pane with Low -E 65 0.270 18 Door 1: Glass 17 •.190 3 Door 2: Glass 17 0.190 3 Door 3: Glass 17 0.190 , 3 Ceiling 1: Flat Ceiling or Scissor Truss 288 38.0 0.0 9 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in REScheck Version 4.4.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name - Title Signature Date Project Title: Holden Addition Report date: 03/20/12 Data filename: Untitled.rck Page 1 of 4 The Commonwealth of Massachusetts Print Form . Department of Industrial Accidents it- Office of Investigations ==i-, i- 1 Congress Street, Suite 100 ; Boston, MA 02114 -2017 www.mass.gov /dia Workers' Compensation Insurance Affidavit: Builders / Contractors /Electricians/Plumbers Applicant Information Please Print Legibly Name ( Business /Organization/Individual): '�,/ C (,✓1 -e '` cD �, L, ( 5 Address: 'S 10 P ∎A e y S , City /State /Zip: S v -c {' \ (, 1 Phone #: g6 D ^ 3 04 4 -1 - 9 1 01 ci�0 Are you an employer? Check the appropriate box: Type of project (required): 1. ❑ 1 am a employer with 4. ❑ I am a general contractor and I employees (full and/or part- time).* have hired the sub - contractors 6. ❑New construction 2. X I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub - contractors have 8. ❑ Demolition working for me in capacity. employees and have workers' g any P tY 9. El Building addition [No workers' comp. insurance comp. insurance.: required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions 3. ❑ I am a homeowner doing all work officers have exercised their 11.11 Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.0 Roof repairs insurance required.] t c. 152, § 1(4), and we have no employees. [No workers' 13.0 Other comp. insurance required.] *Any applicant that checks box #1 must also fill out the section below showing their workers' compensation policy information. f Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub - contractors and state whether or not those entities have employees. if the sub - contractors have employees, they must provide their workers' comp. policy number. I am an employer that is providing workers' compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Policy # or Self -ins. Lic. #: Expiration Date: Job Site Address: City /State /Zip: Attach a copy of the workers' compensation policy declaration page (showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and /or one -year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certii, under , e pains 1, d penalties ofpgjury that the information provided above is true and correct Signature: °' Date: - ..__=___I 1 o� I Phone #: R(D C5 - 3" (-) - , Official use only. Do not write in this area, to be completed by city or town officiaL City or Town: Permit/License # Issuing Authority (circle one): 1. Board of Health 2. Building Department 3. City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector 6. Other Contact Person: Phone #: SECTION 8 - CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ � S Name of License Holder : � 0 C C � � �! l,i License Number LIL'A e r' � f r 1 0 k 5v-4 e C+ cl o cJ ifri ( — l ,)- Addre u( OA Expiration Date L i/3 — S/9 -6- )/ 6 Signature Telephone 9. Registered Home Improvement Contractor: Not Applicable ❑ 1 L-1 —)0(-7 I G� - I � (7), �S Company Name Registration Number S e 16w 5 it-Pd eloco ) - Address I ,� Expiration Date Ai / Telephone - 0 7 1 4 4 (13 - 379 4 SECTION 10- WORKERS' COMPENSATION INSURANCE AFFIDAVIT (M.G.L. c. 152, § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes [13 di No ❑ 11. - Home Owner Exemption The current exemption for "homeowners" was extended to include Owner - occupied Dwellings of one (1) or two(2) families and to allow such homeowner to engage an individual for hire who does not possess a license, provided that the owner acts as supervisor. CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner: Person (s) who own a parcel of land on which he /she resides or intends to reside, on which there is, or is intended to be, a one or two family dwelling, attached or detached structures accessory to such use and/ or farm structures. A person who constructs more than one home in a two - year period shall not be considered a homeowner. Such "homeowner" shall submit to the Building Official, on a form acceptable to the Building Official, that he /she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time, during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152 (Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death) of the Massachusetts General Laws Annotated, you may be liable for person(s) you hire to perform work for you under this permit. The undersigned "homeowner" certifies and assumes responsibility for compliance with the State Building Code, City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature SECTION 5- DESCRIPTION OF PROPOSED WORK (check all applicable) New House ❑ Addition Er Replacement Windows Alteration(s) ❑ Roofing 0 Or Doors D Accessory Bldg. ❑ Demoliti n ❑ New Signs [O] Decks [D Siding [O] Other [0] ���v /d„i Brief Description of Proposed Work: M Sunvtvur- 4- L -vu n )ny I K ? ' 1 0 0400~ Alteration of existing bedroom Yes < No Adding new bedroom Yes No Attached Narra Renovating unfinished basement Yes _No Plans Attache - Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building : One Family X Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? rip r (� d. Proposed Square footage of new construction. d Dimensions L SI.ope d SCc 1 to e. Number of stories? a r i- 1 111-\-:',C. (N61- Y ∎ S+t Ay f. Method of heating? ea . c G or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? r h. Type of construction k V•••• (. i. Is construction within 100 ft. of wetlands? Yes ("-- No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade Cve ) ( S ore A 3 G " k. Will building conform to the Building and Zoning regulations? V Yes No . I. Septic Tank City Sewer t/— Private well City water Supply ( V SECTION 7a - OWNER AUTHORIZATION - TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, (-) et c J 14,) ( ci e r) , as Owner of the subject property hereby authorize J 0t k 3 `1 C C r c , d v� e 1 r` 0 S LI to act o ehalf, in all matters relative to work authorized by th building permit applicatio n. l t(.....i Signature of Owner Date I, -.S 0 l., , c5 C (4'- , as Owner /Authorized Agent hereby declare that the statements arid information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. J6tA 36 /Ce Print Name Signature of Owner fin Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by L c'. \ Se ` L\l� A "® Building Department Lot Size Frontage Setbacks Front Side L: R: l L: lO R: C5� Rear Building Height Bldg. Square Footage D ?() % • Open Space Footage (Lot area minus bldg & paved parking) # of Parking Spaces Fill: (volume & Location) A. Has a Special Permit /Variance /Finding ever been issued for /on the site? NO ® DON'T KNOW 0 YES 0 IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO ® DONT KNOW ® YES Q IF YES: enter Book Page and /or Document # B. Does the site contain a brook, body of water or wetlands? NO ►11 DON'T KNOW ® YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained ® Obtained ® , Date Issued: C. Do any signs exist on the property? YES 0 NO YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property ? YES 0 NO e IF YES, describe size, type and location: E. Will the construction activity disturb (clearing, grading, excavation, or filling) over 1 acre or is it part of a common plan that will disturb over 1 acre? YES ® NO Co IF YES, then a Northampton Storm Water Management Permit from the DPW is required. , Aj Department use only ?" 1 City of Northampton Status of Permit: os OSA Building Department Curb Cut/Driveway Permit lam'`` 212 Main Street Sewer /Septic Availability Room 100 Water/Well Availability o f 0°. Northampton, MA 01060 Two Sets of Structural Plans �t t+ phone 413 - 587 -1240 Fax 413 - 587 -1272 Plot/Site Plans Other Specify APPLICATION TO CONSTRUCT, ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 - SITE INFORMATION 1.1 Property Address: This section to be completed by office 1 C: 4S dTKT Map Lot Unit port ri-11414/PTLY - X Pk t.4 • Zone Overlay District Elm St. District CB District SECTION 2 - PROPERTY OWNERSHIP /AUTHORIZED AGENT 2.1 Owner of Record: �AUi /4°1_1- L'--f ?1 a� si sr flwcrin eolv / .� tt4. 0106 a Name (Print) Current Mailing Address: ) I / 4 r 3 • .717. 3 3 7 3 #4let'Ir'—rj Telephone Signature 2.2 Authorized Agent: "5 0\ ti ` Sa(-1 c e -) 6 7: 5e,/ E- ► (m e(,,40c) iM/r Name (Print) 4 Current Mailing Address: O/ WE L-I13_S1c7-0716 Signature - Telephone SECTION 3 - ESTIMATED CONSTRUCTION COSTS Item Estimated Cost (Dollars) to be Official Use Only completed by permit applicant 1. Building (a) Building Permit Fee 71-,5 ► c i . v u 2. Electrical (b) Estimated Total Cost of 532e. v) Construction from (6) 3. Plumbing Building Permit Fee , ®� S2Get . tJ U A 4. Mechanical (HVAC) • 5. Fire Protection 6. Total = +2 +3 +4 +5) k.-?,///. uo Check Number A /1/ /'‘e/ This Section For Official Use Only Date Building Permit Number: Issued: Signature: Building Commissioner /Inspector of Buildings Date b j oft _— File # BP- 2012 -0848 APPLICANT /CONTACT PERSON JOHN B JOYCE L 4 i j v if ADDRESS/PHONE 78 TIMBER DR EAST LONGMEADOW (413) 519 -0716 PROPERTY LOCATION 22 EAST ST MAP 38B PARCEL 131 001 ZONE URB(100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid 6710 / /f e 12 11 •6'D Typeof Construction: CONSTRUCT SUNROOM /LAUNDRY ROOM, PORCH & 2ND FLR DEN New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/ Statement or License 77942 Agit sets of Plans / Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFOJ.2MATION PRESENTED: Approved Additional permits required (see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND /OR Special Permit With Site Plan Major Project: Site Plan AND /OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received & Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management m iti Delay O Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning & Development for more information. 22 EAST ST BP- 2012 -0848 GIS #: COMMONWEALTH OF MASSACHUSETTS Map:Block: 38B - 131 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: ADDITION BUILDING PERMIT Permit # BP- 2012 -0848 Project # JS-2012-001492 Est. Cost: $83111.00 Fee: $174.60 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: JOHN B JOYCE 77942 Lot Size(sq. ft.): 5009.40 Owner: FEMIANO SAMUEL & P COONERTY C/O DAVID R HOLDEN Zoning: URB(100)/ Applicant: JOHN B JOYCE AT: 22 EAST ST Applicant Address: Phone: Insurance: 78 TIMBER DR (413) 519 - 0716 EAST LONGMEADOWMA01028 ISSUED ON:4/12/2012 0:00:00 TO PERFORM THE FOLLOWING WORK: CONSTRUCT SUNROOM /LAUNDRY ROOM, PORCH & 2ND FLR DEN POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace /Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 4/12/2012 0:00:00 $174.60 212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272 Louis Hasbrouck — Building Commissioner