24C-019
1 1 barry engineers and constructors, inc. 176 churchill street, pittsfield, massachusetts 01201 413 - 443 -6591 December 16, 2009 Anthony Patillo City of Northampton Building Commissioner Office of the Building Inspector Puchalski Municipal Building 212 Main Street Northampton, MA. 01060 RE: YMCA Repairs Dear Mr. Patillo: In accordance with Section 116 of the Massachusetts State Building Code (Construction Control), Barry Engineers & Constructors, Inc. was retained for the following: 1. Inspection of fire damage to existing building structure and preparation of structural plans for repairs. 2. Review, for conformance to the design concept, of submittals by the contractor as required by the construction contract documents as submitted for building permit. 3. Review and approval of the quality control procedures for structural components. 4. Engineering inspection of critical construction components requiring controlled materials or construction specified in the accepted engineering practice standards. Barry Engineers & Constructors, Inc. was retained by Dietz & Company Architects, Inc., to perform the necessary professional services and to be present on the construction site on a periodic basis to determine that, generally, the work is proceeding in accordance with the documents approved for the building permit. Barry Engineers & Constructors, Inc. submitted periodic progress reports on the structural work. In accordance with the above procedures, I hereby state that the structural work for the renovation work at the YMCA building is at a satisfactory level of completion and is ready for occupancy. tace `i r 4 / r William M. Barry, P.E. �7 4 v F a5 Frm 09ge /9 DIETZ & COMPANY ARCHITECTS, INC. - TRANSMITTAL TO: Louis Hasbrouk DATE: December 17, 2009 Building Inspector Pulchaski Municipal Building 212 Main Street Northampton, MA 01060 CC: Tony Patillo RE: YMCA File Northampton, MA Project #20803 FROM: Blake Williams AIA ® ATTACHED, via US mail ❑ FAXED, number of pages not including this page: COPIES DATE CSI No. DESCRIPTION 2 12.16.09 Structural Engineer Letter 17 Hampden Street Springfield, MA 01 103 telephone (413) 733 -6798 REMARKS facsimile (413) 732 -4385 Hello Louis, e-mail office @dietzarch.com Please see the enclosed sign off letter by the structural engineer. Thank you, shop drawings logged by: v: \20803 - northampton ymca locker rooms \ — project management (phases 02 thru 06) \docs sent \reg_2009. 12.15 (fire plan to tpatillo) \trans_2009. 12.15 (lhasbrouck).doc DIETZ - ........ MMMMM ..ur o' . Nam uo. yr co. Architects I 2 3 4 5 DIETZ MMMMM .1•110, urn Mal 1 •IP' C D Architects INCORPORATED 17 HAMPDEN ST SPRINGFIELD, MA g 19 01 ) 733-6798 C)-- I I - Z I --- O ( 0 o IMI I I : . 0 WOMEN'S LOCKERS I — CORRIDOR a 1 = O j O Izoel — 7� Ill Z 1 f I r r — — y�� �{- • CC O I II I 1 I O _ j ■111:., j F l / r C 1 L 0T0 • MENU V ATORY C U U M LO CKERS — iiiil _ Izozl — — _ _ s I 1 I 1 1 1 1 1 I C ® ¢ _ ° 0 ert x Z J J -- 1 b MEN'S SHOWER 0 Q F I �� I I L Izls1 w ' 2 a i re u a 0 O N i� - Q Z . 1 I 0 - MEN'S LOCKERS OO ` w `o ETU F I I I ® x cc N — j WOMEN'S SAUNA — I z041 ;Irk �� STRETCHING ROO } — J " 1 Izlo �J — MENS SAUNA b i ' WOMEN' WOMEN' SHOW zHALL 1 ' 12161 M�3��7� Iz06l I I MEN'S STEAM RM zn I 1 0 I 1 N I' I - - -- II � ' 1 X j oo ti r (3 a Z o a Y ce SYMBOLS o V J I O ILLUMINATED EXIT SIGN ` �� H � ` r O DOT/EMERGENCY NCY LIGHT 1 e CO N_ OMB EMERGENCY UGHT PROJECT NQ 20803A U CAD FILE: + � -aw a DRAWN BY:SO CHK'D BY: BW T C © Copyright 2009 VVV LL B y Diet 8 Co. Architects All Rights Reserved. z A SHEET TITLE Q A - — M co EXIT PLAN SKA -03 Al SCALE: 3/32" = I' -0" 0 8' 16' 24' EXIT PLAN 0. N I 1 2 1 3 1 4 1 5 DIETZ & COMPANY ARCHITECTS, INC. d ge......„ / 9 s TRANSMITTAL TO: AnthonyPatillo DATE: December 15, 2009 Building Commissioner City of Northampton City Hall 210 Main Street Northampton, MA 01060 CC: Louis Hasbrouck RE: YMCA File Northampton, MA Project #20803 FROM: Blake Williams AIA ® ATTACHED, via US mail ❑ FAXED, number of pages not including this page: COPIES DATE CSI No. DESCRIPTION 2 12.15.09 Fire Exit Plan 17 Hampden Street Springfield, MA 01 103 telephone (413) 733 -6798 facsimile REMARKS (413) 732 -4385 e -mail Hello Tony, office @dietzarch.com Please see the enclosed Fire Exit Plan for the YMCA Northampton Locker Room project. Thank you, shop drawings logged by: v: \20803 - northampton ymca locker rooms \ — project management (phases 02 thru 06) \docs sent \reg_2009. 12.15 (fire plan to tpatillo) \trans_2009. 12.15 (t patillo).doc DIETZ • ...• .... ..... .. -- . .... ■..., IN' . co. mot Architects • OPERATION: Eil PNEUMATIC 0 ELECTRIC 0 HYDRAULIC PIPING SUPERVISED 0 YES 0 NO [DETECTING MEDIA SUPERVISED? 0 YES 0 NO DOES THE VALVE OPERATE FROM THE MANUAL TRIP AND /OR REMOTE CONTROL? fl YES 0 NO DELUGE•& 15 THERE AN ACCESSIBLE FACILITY IN EACH CIRCUIT FOR TESTING? D YES 0 NO •'; :.PREACTION '. IF NO, EXPLAIN: VALVES I Does each circuit operate Does each circuit Maximum time to MAKE MODEL supervision loss alarm? operate valve release? operate release YES NO YES NO MIN. SEC. . HYDROSTATIC: Hydrostatic tests shall be made at not less than 200 psi (13.6 bars) for two hours or 50 psi (3.4 bars) above static • pressure in excess of 150 psi (10,3 bars) for two hours. Differential dry -pipe valve clappers shall be left open during test to prevent TEST . . damage. All aboveground piping leakage shall be stopped. r DESCRIPTION PNEUMATIC: Establish 40 psi (2.7 bars) air pressure and measure drop which shall not exceed 1 -1/2 psi (0.1' bars) in 24 hours. Test _ ,_ • pressure tanks at normal water level and air pressure and measure air pressure drop which shall not exceed 1 -1/2 psi (0-1 bars) in 24 hours. q ALL PIPING HYDROSTATICALLY TESTED AT 2OO PSI FOR .. ' Hrs: • ' IF NO, STATE REASON • DRY PIPING PNEUMATICALLY TESTED? 0 YES Rflo WO DR i PIPE EQUIPMENT OPERATES PROPERLY? [a�'ES ENO • • • DRAIN READING OF GAGE LOCATED NEAR WATER SUPPLY TEST PIPE: RESIDUAL PRESSURE WITH VALVE IN TEST PIPE TESTS TEST 9 PSI OPEN WIDE 7? ,.PSI Underground mains and lead -in connections to system risers shall be flushed before connection made to sprinkler piping. VERIFIED BY COPY OF THE FORM NUMBER 85B? EI YES C NO OTHER EXPLAIN • FLUSHED BY INSTALLER OF UNDERGROUND E X isnA Ir UNDERGRo UNG SPRINKLER PIPING? ❑ YES ❑ NO BLANK NUMBER USED LOCATIONS NUMBER REMOVED TESTING GASKETS 0 WELDED PIPING? El YES [VW) IF YES DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING PROCEDURES COMPLY WITH Ab f 9 THE REQUIREMENTS OF AT LEAST AWS D10.9, LEVEL AR -3? LI YES LINO WELDING DO YOU CERTIFY THAT THE WELDING WAS PERFORMED BY WELDERS QUALIFIED IN COMPLIANCE . ,WITH THE REQUIREMENTS OF AT I,EAST AWS D10.9, LEVEL AR -3? . ' Q YES . ❑ NO DO YOU CERTIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A DOCUMENTED QUALITY CONTROL PROCEDURE TO INSURE THAT ALL DISCS ARE RETRIEVED. THAT OPENINGS IN PIPING ARE SMOOTH, THAT SLAG AND OTHER WELDING RESIDUE ARE REMOVED, AND THAT INTERNAL DIAMETERS OF PIPING ARE NOT PENETRATED? E YES ONO HYDRAULIC NAMEPLATE PROVIDED? 2.YES El NO DATA IF NO EXPLAIN: NAMEPLATE • DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN: - REMARKS • • • • NAME OF INSTALLI £ CONTRACTOR Ili .1 1 R • tMG• • MEAN. GO#IT R$CraRS • TESTS WITNESSED BY... . :: :.: >;;:.. SIGNATURES FOR PRO • ER ( di TITLE DATE I C E 1 Iz /IS/e' FOR IN T t ,tc ( 1 ed) TITLE DATE • l,� _ I , ,r �- , L it4 t -� 1 iZ/ /� d ADDITIONAL EXPLANATIO ND NOTES: f / M.J. MORAN, INC. Mechanical Contractor 4 South Main Street Haydenville, MA 01039 B5A BACK • CONTRACTOR'S MATERIAL & TEST CERTIFICATE FOR ABOVEGROUND PIPING PROCEDURE: Upon completion of work, inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners and contractor. It is understood the owner's representatives signature in no way prejudices any claim against the contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. PROPERTY NAME DATE NJ41lASilmE_ RE•/ONpL YmcA 1,1!q-01 PROPERTY ADDRESS e2811 ?nosa,scr StnL,Er 4 NORTNATnPr0w✓ J r1ASS. 01060 • ACCEPTED BY APPROVING AUTHORITY'(S) NAMES ADDRESS PLANS INSTALLATION CONFORMS TO ACCEPTED PLANS [ YES ❑ NO EQUIPMENT USED IS APPROVED (IF NO, STATE DEVIATIONS BELOW) ❑ YES ❑ NO HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCATION OF CONTROL [y�YES El NO VALVES AND THE CARE AND MAINTENANCE OF THIS NEW EQUIPMENT? IF NO, EXPLAIN: INSTRUCTIONS HAVE COPIES OF APPROPRIATE INSTRUCTIONS AND CARE AND MAINTENANCE CHARTS BEEN ar YES ❑ NO LEFT ON PREMISES? IF NO, EXPLAIN: LOCATION OF SUPPLIES BUILDINGS SEGaLm r aar Rooms R s Fauows : SYSTEM doco AIAGgL , Owls. SYAm Sro mpg s ,i& s .h.,113,04.4.1 [ooKI/L J S Howerc. ANA sa MA Rooms MAKE MODEL YEAR OF ORIFICE SIZE QUANTITY TEMPERATURE _ MANUFACTURE RATING I VIKING- 111RAG-E I 1009 K=S, L Hd /SS SPRINKLERS lr /1 I it - rr 5 1 SS 11 11 i 11 11 13 18 \/IcTithhlc. S Qij PEND ! 1005 K=S.& 6 X81 ,' Son S.w I. 5 a 0o --.___1' a-i(( c17'IP1�lr I. ,� J 7 I _ d g(o PIPE CONFORMS TO AlF /3 STANDARD [7'ES NO PIPE AND FITTINGS CONFORM TO NFPR 13 STANDARD [14 0 N FITTINGS IF NO, EXPLAIN: ALARM ALARM DEVICE MAXIMUM TIME TO OPERATE THROUGH,TEST_PIPE. VALVE OR TYPE MAKE MODEL MIN, - SEC. FLOW vpue flow Arran. V. n -F a .38 INDICATOR • • DRY VALVE :: r Q:O:D< :;,'; :':i ';:;:::.;- >>s: <;• :. ' • MAKE MODEL SERIAL NUMBER MAKE MODEL SERIAL NUMBER TIME TO TRIP: WATER AIR ":): :;'- TRIP'POINT;AIR': •: :':' > %T!m'Water : Operated ' : DRY PIPE THRU TEST PIPE PRESSURE PRESSURE PRESSURE . utle PtO OPERATING MIN. SEC. PSI PSI PSI MIN. SEC. . MIN. SEC. TEST WITHOUT Q.O.D. WITH ' Q.O.D. i IF NO, EXPLAIN: M.J. M O RAN , INC. LETTER OF TRANSMITTAL FIRE PROTECTION DIVISION 4 SOUTH MAIN STREET TELEPHONE: FAX: HAYDENVILLE, MA 01039 (413)268 -7251 (413)268 -9375 TO: Northampton Building Department DATE: 12 -17 -09 1 JOB NUMBER: 09 -824 212 Main Street ATTENTION: Mr. Tony Patillo Room 100, Building Dept. RE: Fire Sprinklers at: Northampton, MA 01060 YMCA WE ARE SENDING YOU ® ATTACHED ❑UNDER SEPARATE COVER VIA THE FOLLOWING ITEMS: ❑SHOP DRAWINGS ❑PRINTS ❑PLANS ['SAMPLES DSPECIFICATIONS ❑COPY OF LETTER ❑CHANGE ORDER ❑ COPIES DATE NUMBER DESCRIPTION One 12 -4 -09 Copy Contractors material and test certificate for above ground piping. Second floor rooms as highlighted on test certificate. THESE ARE TRANSMITTED AS CHECKED BELOW: ❑For approval ['Approved as submitted DResubmit copies for approval ['For your use ❑Approved as noted ❑Submit copies for distribution DAs requested ❑Returned for corrections ❑Return corrected prints ['For review and comment El ❑FOR BIDS DUE: , 2002 [PRINTS RETURNED AFTER LOAN TO US REMARKS: Copies have been sent to: Fire Dept. Owner Owners Insurer Please call with any questions. COPY TO: Job File SIGNED: & zza / ., Date: /d - /7 - 0 9 M. J. M O RAN , INC. LETTER OF TRANSMITTAL ' FIRE PROTECTION DIVISION 4 SOUTH MAIN STREET TELEPHONE: FAX: HAYDENVILLE, MA 01039 (413)268 -7251 (413)268 -9375 TO: Northampton Building Dept. DATE: 12 -17 -09 1 JOB NUMBER: 09 -824 212 Main Street ATTENTION: Mr. Tony Patillo Room 100, Building Dept. RE: Fire Sprinklers Northampton, MA 01060 YMCA Northampton WE ARE SENDING YOU ❑ ATTACHED ['UNDER SEPARATE COVER VIA _ THE FOLLOWING ITEMS: ❑SHOP DRAWINGS ❑PRINTS ❑PLANS ❑SAMPLES ESPECIFICATIONS ['COPY OF LETTER ❑CHANGE ORDER ❑ COPIES DATE NUMBER DESCRIPTION One 12 -14 -09 Copy Fire sprinkler Record Drawings Second Floor Rooms as follows: Mechanical, fitness,stair, storage, mens and womans locker, mens and womans shower and Saunas. THESE ARE TRANSMITTED AS CHECKED BELOW: For approval ❑Approved as submitted ❑Resubmit copies for approval For your use ['Approved as noted ❑Submit copies for distribution ❑As requested ['Returned for corrections ['Return corrected prints ❑For review and comment ❑ ❑FOR BIDS DUE: , 2002 ❑PRINTS RETURNED AFTER LOAN TO US REMARKS: Copies have been sent to: Fire Dept. Owner Owners Insurer Please call me with any questions. Thanks! COPY TO: Job File SIGNED: hrrt ,f,rx.,e Date: /x7 9 4 tilr ' -::) ■ - =,:ti."4 ) :;..) vu 7 �=L This Structure Is Declared Unsafe For H Occupancy or Use. It Is Unlawful For Any Person To . Or Occupy This Buliding Use After di • _.0 , • Any Unauthorized Person Removing This Sign ' WILL BE PROSECUtED 2..6 /.. 4-- , Address of Building Building Official Code i,(' Art. /2( . Sec. Date Refer To Ordinance No.. SVAHS 1i f .,L-1 t D V't •,'"- i s.--. - ,..4 '1 !7:i. :2 4 ‘ . ...4..;.... i...... 4r.0.440 as.. 440.44.0 .40.... ...... ...- ...., ''''''''' .;,?-; a ; ,.........- t .„...,.. - *"a% '''......." .''' F *Arr.... •,. Y - ...a.... - 7 ; e4WL4 Mit . Welfit "7: 7: MX Ill'i.,-Vet /resse--- — - - jet limo mem max - maw satavaraaist , ,, - 411 - • -4 P , , ',-- a , •••••••.------- // — . 1?:7r - , ---- ... . '' 11 " c ..7 " e , ,P) ;A ,iir (,..:-/ ../. / Ayr * ? tf, .,.. .,..; : ;140%,,r. - - ,c I/ /., i r ---- t Arricie / , ,--- , $ectirt et the Zentres Ordinance i WitEkEitt., vioiatporrs ot < Arfbcte , l'?"ect! (.1- f he RtH kthrl-fT Cenje''' hcree b.een f-mmd Mr the . tle,ec 4 0..61, these prerrases, ET ES HEREBY ORDERED in accordance with the above Code that CI Ei meteors cease, desist f anti .....mb— ....--....,, . 4 „, 7734 -..--.., -2 Aoli „,,, , -_, 7:77 ,---__,-, ‘ zi• ---;,,.., 4,,, , ..-_, i Ni # -'-''.. 'Nr) — 'ta_ rr ,... i 14 . a 6.1 ..kaLt...satt“,24 , a..E./Laa ..t. 4 a r a Vf , ,.! (1 , 44, ay., t.t. a. .,..... r • ' ir i - AB persons acting contrary to this order or removing or mutilating this oticyare liable to arrest ....--, i unless 54 c h Vii;Ori ;5 QUi Vt the ...eparirl, WILDING OFFICIAL &" c 4 : ' 6a * ft t if IS,All ) )1: 1 --:14147:: 1*•MM ) &. ' an . .0.:•.,4,..a.,_ 97 / ......... 4" ..)Ci t. .. ) ' ' / / , — . ,. ,.. ,. .......... _ WHEREAS, violations of { Article , Section of the Building Cod& ? have been found on Article , Section of the Code) ., these premises, iT iS HEREBY ORDERED in accordance with the above Code that oil persons cease, desist from, and 7 , A ix at once pertaining to construction, alterations or repa4s on these premises known as 7/4/C4 2 ' 1 4' le CkCO 4' 41P--,- 1 All persons acting contrary to this order or removing or mutilating t notice are' able to arrest unless such action is authorizeci by the Department. / .....---67 - _ . _ WILDING OFFICIAL ri_f“11 AA M.J. MORAN, INC. LETTER OF TRANSMITTAL 4 SOUTH MAIN STREET TELEPHONE: FAX: HAYDENVILLE, MA 01039 (413) 268 -7251 (413) 268 -9375 TO: Office of the Building Inspector DATE: 12/18/09 1 JOB NUMBER: 2t2 Main Street ATTENTION: Tony Patillo Northampton, MA 01060 RE: Hampshire YMCA WE ARE SENDING YOU ® ATTACHED ['UNDER SEPARATE COVER VIA _ THE FOLLOWING ITEMS: ['SHOP DRAWINGS [PRINTS [PLANS ❑SAMPLES ❑SPECIFICATIONS ❑COPY OF LETTER ❑CHANGE ORDER ❑ COPIES DATE NUMBER DESCRIPTION 1 Balance Reports Hampshire YMCA Renovation THESE ARE TRANSMITTED AS CHECKED BELOW: ❑For approval ❑Approved as submitted ❑Resubmit copies for approval For your use ['Approved as noted ❑Submit copies for distribution ❑As requested ❑Returned for corrections ❑Return corrected prints ❑For review and comment ❑ ❑FOR BIDS DUE: [PRINTS RETURNED AFTER LOAN TO US REMARKS Thank you! COPY TO: File SIGNED: \ 71/1"- Date: /1 f / G' 7 M . AIR OUTLET TEST REPORT HAMPSHIRE REGIONAL GR. OUTLET K (AK) DESIGN ACTUAL % OF YMCA NO. SIZE CFM FPM FPM CFM DESIGN S -6 STRETCHING RM. 210 1 12X12 285 254 STRETCHING RM. 210 2 12X12 285 277 STRETCHING RM. 210 3 12X12 285 243 STRETCHING RM. 210 4 12X12 285 250 CORRIDOR 5 12X12 220 203 MEN'S LAV. 214 6 12X12 285 243 MEN'S LAV. 214 7 12X12 285 253 MEN'S LOCKERS 213 8 12X12 285 252 MEN'S LOCKERS 213 9 12X12 285 253 2500 2228 89% NEW RTU WOMEN'S LOCKER 1 12X12 250 268 WOMEN'S LOCKER 2 12X12 250 254 WOMEN'S LOCKER 3 12X12 250 256 WOMEN'S LOCKER 4 12X12 250 260 WOMEN'S LOCKER 5 10X6 0.72 0.3 200 667 602 181 1 200 1219 102% RETURN 1 24X24 900 910 101% UV -1 WOMENS SHOWER 1 14" RD vpt 1.07 750 702 677 723 96% UV -2 MENS SHOWER 1 12X12 375 344 MENS SHOWER 2 12X12 375 338 750 682 91% 12/18/2009 LAB.CO. AIR AND WATER BALANCING 1 I , SUPPLY FAN REPORT PROJECT NAME HAMPSHIRE REGIONAL YMCA NORTHAMPTON,MA. DATE 12/17/2009 UNIT DATA TEST DATA SYSTEM # S -6 CFM DESIGN 2,500 AREA SERVED MEN' LOCKER RM. CFM DELIVERED 2,228 UNIT LOCATION 2nd FLR. MER T.S.P. DESIGN NOT LISTED VOLTAGE / PHASE 208 / 3 T.S.P. DELIVERED 2.74" FAN MFR'R CARRIER FAN DESIGN RPM NOT LISTED FAN MODEL # NO TAG FAN DELIVERED RPM 1410 MOTOR MFR'R CENTURY AMPS RATED 13.6 MOTOR HP 5 AMPS DELIVERED 8.0 / 7.2 / 7.2 MOTOR RPM 1740 SUCTION S.P. - 2.60" MOTOR S.F. 1.15 DISCHARGE S.P. 0.14" MOTOR FRAME E184T DRIVE DATA MOTOR SHEAVE 6.5" X 1 1/8" DESIGN MIN. O.A. NOT LISTED FAN PULLEY 7" X 1 3/16" ACTUAL MIN. O.A. 508 CFM BELTS 1 OF A -59 O.A. CONTROL POS. 28% SHEAVE POSITION 100% CLOSED CENTER TO CENTER 21" NOTES : MINIMUM OUTSIDE AIR INLET SIZE INLET AREA AVERAGE FPM ACTUAL CFM 30" X 12" 2.5 203 508 12/18/2009 LAB.CO. AIR WATER BALANCING 1 AIR OUTLET TEST REPORT HAMPSHIRE REGIONAL GR. OUTLET K (AK) DESIGN ACTUAL % OF YMCA NO. SIZE CFM FPM FPM CFM DESIGN H -6 TOILET 1 6X6 75 85 CLOSET 2 6X6 0.72 0.18 75 417 511 92 TOILET 3 6X6 75 91 225 268 119% H -7 WOMEN'S SHOWER 1 14X6 0.65 0.38 267 739 280 WOMEN'S SHOWER 2 14X6 0.65 0.38 267 674 256 WOMEN'S SHOWER 3 14X6 0.65 0.38 267 643 244 801 780 97% H -7 V.P.T. 14" RD 1.07 801 750 737 787 98% • 12/18/2009 LAB.CO. AIR AND WATER BALANCING 1 EXHAUST FAN REPORT PROJECT NAME HAMPSHIRE REGIONAL YMCA NORTHAMPTON,MA. JOB # DATE 12/17/2009 SYSTEM NO. H -6 H -7 AREA SERVED LADIES TOILET LADIES SHOWER FAN LOCATION ROOF ROOF CFM DESIGN 225 800 CFM DELIVERED 268 787 T.S.P. DESIGN 0.25" 0.25" T.S.P. DELIVERED 0.17" 0.26" DISCHARGE S.P. 0.00" 0.00" SUCTION S.P. - 0.17" - 0.26" FAN DES. RPM 1047 953 FAN DEL. RPM 1050 928 VOLTAGE /PHASE 115 / 1 115 / 1 AMPS RATED 1.4 3.6 AMPS DEL. 1.3 2.9 FAN MFR'R COOK COOK FAN MODEL # 90C10DH 120C2B MOTOR MFR'R A.O. SMITH MARATHON MOTOR HP 1/25 1/6 MOTOR RPM 1050 1725 MOTOR S.F. 1 1.35 MOTOR FRAME 42Y 48Y MOTOR SHEAVE DIRECT DRIVE 1VL34 X 1/2" FAN PULLEY DIRECT DRIVE 5" X 3/4" BELTS DIRECT DRIVE 1 OF 4L230 SHEAVE POS. DIRECT DRIVE 75% CLOSED CENTER TO CENTER DIRECT DRIVE 5" 12/18/2009 LAB.CO. AIR WATER BALANCING 1 SUPPLY FAN REPORT PROJECT NAME HAMPSHIRE REGIONAL YMCA NORTHAMPTON,MA. DATE 12/17/2009 UNIT DATA TEST DATA SYSTEM # NEW RTU CFM DESIGN 1,200 AREA SERVED WOMENS LOCKER RM. CFM DELIVERED 1,219 UNIT LOCATION ROOF T.S.P. DESIGN NOT LISTED VOLTAGE / PHASE 208/3/60 T.S.P. DELIVERED 0.50" FAN MFR'R LENNOX FAN DESIGN RPM NOT LISTED FAN MODEL # TGA036S2BM1Y FAN DELIVERED RPM 791 MOTOR MFR'R BALDOR AMPS RATED 4.3 MOTOR HP 1.5 AMPS DELIVERED 2.2 / 2.3 / 2.2 MOTOR RPM 1755 SUCTION S.P. - 0.30" MOTOR S.F. 56HZ DISCHARGE S.P. 0.20" MOTOR FRAME 1.15 DRIVE DATA MOTOR SHEAVE 1VP34 X 7/8 DESIGN MIN. O.A. 300 CFM FAN PULLEY AK54 X 1 ACTUAL MIN. O.A. 309 CFM BELTS 1 OF A40 O.A. CONTROL POS. POT. SHEAVE POSITION 100% OPEN CENTER TO CENTER 15" NOTES : 12/18/2009 LAB.CO. AIR WATER BALANCING 1 CERTIFIED TEST, ADJUST AND BALANCE REPORT DATE: 12/18/2009 PROJECT: HAMPSHIRE REGIONAL YMCA LOCATION: NORTHAMPTON, MASSACHUSETTS CUSTOMER: M. J. MORAN CONTRACTOR: LABCO Air & Water Balancing, LLC ADDRESS: PO BOX 316 West Suffield, Connecticut 06093 PHONE 860- 668 -1329 FAX 860 - 668 -7089 #818599 T.A.B.B. CERTIFICATION 1 .„$: 1.7 il A: EXP. 3/2011 PHOTOMETRIC FILENAME : MPTR- 2F- 150.IES DESCRIPTIVE INFORMATION (From Photometric File) COOPER LIGHTING - LUMARK MPTR -2F -150 ARCHITECTURAL AREA LUMINAIRE - TYPE II 150 WATT PULSE -START CLEAR ED -28 HORIZONTAL BURN TEMPLATE SPECIFICATION Horizontal Footcandles Scale: 1 Inch = 10 Ft. Light Loss Factor = 1.00 Lumens Per Lamp = 14000 Total Lamp Lumens = 14000 Mounting Height = 15.00 Ft Maximum Calculated Value = 10.47 Fc Arrangement: Single LUMINAIRE LAYOUT INFORMATION X Y Z Orient Tilt Roll Spin Tilt Correction 1 0.00 0.00 15.00 0.00 0.00 0.00 0.00 1.00 Photometric Toolbox Professional Edition (c) copyright 1995 -2009 by Lighting Analysts, Inc. Page 2 Calculations based on published IES Methods and recommendations. Results derived from content of manufacturers photometric file. 0 101 COOPER Lighting Photometric Toolbox . 2 3 1 . . ")/ - 4/ � ., , r, , , _ _ , . , , ii ,, , , , , , , , . /., 1 . \ I i ,, 2 i (/ , i 'N'- '^ , .. j 1 t \2\\\\ \ 1 : b �� 1 �. t \ i 1 COOPER LIGHTING - LUMARK Horizontal Footcandles MPTR -2F -150 Scale: 1 Inch = 10 Ft. ARCHITECTURAL AREA LUMINAIRE - TYPE II Light Loss Factor = 1.00 150 WATT PULSE -START CLEAR ED -28 HORIZONTAL Lumens Per Lamp = 14000 BURN Total Lamp Lumens = 14000 Mounting Height = 15.00 Ft Maximum Calculated Value = 10.47 Fc Arrangement: Single Photometric Toolbox Professional Edition (c) copyright 1995 -2009 by Lighting Analysts, Inc. Page 1 Calculations based on published IES Methods and recommendations. Results derived from content of manufacturers photometric file. 0 COOPER Lighting Photometric Toolbox .2 , .5 , 1 ,,,,- 411 ,, , „.7----' , \ , . „, , . , , , . ,„ . . , , , \ .. „ „ ., _____,/, . „ , , \ , , , , , . „ , ill , , , 2 l d ii 1 1 , l , --,,,\ i A. , , \ , . I 1 ,,,,, . ,,,,,.- , \ ,l \ , 1 Z ,„, , , i , , ,„ 5 IP . . • 1 , , ii -,,„N ____,,,, i . ,,,,, ,\\, \ . COOPER LIGHTING - LUMARK M PTR -2F -150 ARCHITECTURAL AREA LUMINAIRE - TYPE II 150 WATT PULSE -START CLEAR ED -28 HORIZONTAL BURN • PHOTOMETRIC FILENAME : MPTR- 2F- 150.IES DESCRIPTIVE INFORMATION (From Photometric File) COOPER LIGHTING - LUMARK MPTR -2 F -150 ARCHITECTURAL AREA LUMINAIRE - TYPE II 150 WATT PULSE -START CLEAR ED -28 HORIZONTAL BURN TEMPLATE SPECIFICATION Horizontal Footcandles Scale: 1 Inch = 10 Ft. Light Loss Factor = 1.00 Lumens Per Lamp = 14000 Total Lamp Lumens = 14000 Mounting Height = 15.00 Ft Maximum Calculated Value = 10.47 Fc Arrangement: Single LUMINAIRE LAYOUT INFORMATION X Y Z Orient Tilt Roll Spin Tilt Correction 1 0.00 0.00 15.00 0.00 0.00 0.00 0.00 1.00 • Photometric Toolbox Professional Edition (c) copyright 1995 -2009 by Lighting Analysts, Inc. Page 2 Calculations based on published IES Methods and recommendations. Results derived from content of manufacturers photometric file. Horizontal Footcandles Scale: 1 Inch = 10 Ft. Light Loss Factor = 1.00 Lumens Per Lamp = 14000 Total Lamp Lumens = 14000 Mounting Height = 15.00 Ft Maximum Calculated Value = 10.47 Fc Arrangement: Single • Photometric Toolbox Professional Edition (c) copyright 1995 -2009 by Lighting Analysts, Inc. Page 1 Calculations based on published IES Methods and recommendations. Results derived from content of manufacturers photometric file. 1 '{ SSS SOUARE STRAIGHT STEEL a. d • ORDERING INFORMATION SAMPLE NUMBER: SSSSA20SFMIXG } Series Shaft Size' Wall Mounting f Daeo Type Finish Fixture Number & Length of Accessories (ardor aoparaloly) y SSS=Square 4 =4" Thidtness Height f S =Stool F =Durk Broom Mounting Location of Arm A=112" Tuppod Hub' Straight 5=5" A =.120" 10 =10' Square L.Ourk 2=2 3/0' 0.0. Tenon Anna X -Novo 0=3/4" Toppod Hub' Steel 5=8" M =.188" 15 =15' Bose Platinum 3=31/2" O.D. Tenon 1 =Single C=Corwonlenco Outlet.' X=.250" 20=20' Plato T =Graphite 9=3" O.D. Tenon 2=2 eP 180° GoGrounding Lug ;f 29 =25' Metallic M =Typo M 3 =Trlplo' (Mug, Who N8 AWG) 30 =30' V =Gray Zulylxr 2 4..4 (:t 03' E =GFI Corlvpnloncn Oudut• g 35 =35' W. -Wldda G. - >T 0 86" H=AllditIonel Hondhote and Cover' 1 39=39' Y_Oleck X'None' V =Vlbrutlon Dumper X =Cuatorn Color a NOTES: it All short Slur nomind. See EPA chart for ahcr she and wall thIcknaaa. 2 3 4150'.3 Specify when 0olotln11 n hand tenan mounting cenlitpu:anon, 4 Location II 3' Amon Ow and BO' from Immlholo. Spndfy If douiro 8 oeherwoo. 5 Outlet is located 4 nbove harm and on mane onto of pain as Iwnrlholo, unlace spoolfIod ulherwlen, 0 firarm ole not Included, provIolun only. 7 Aulsllunnt hnldholo In hooted I2" below polo lop and 00` from standard heodholo location, colors athorwieo apodlio I. Bolt Anchor a Wall Base Circle Bolt Shaft Bolt Nat. 1 Mt Catalog '' Thickness Square Die. Pro). She' Dla. &, Wt. EPA (Sq. Ft.)' EPA (Sq. Ft.)' Maximum 4 Height Number (In.) (In.) (In.) (In.) (In.) Length (In.) (Lbs.) At Polo Top 2' Above Polo Top Load (Lbs_) • PI MN S BC BP B D x AB x H 70 80 90 100 70 80 90 100 8 SSS4A08SF .120 10 1/2 11.0 4 1/2 4 3/4 x 25 x 3 70 55.2 41.8 32.6 26.0 43,9 33.2 25.9 20.7 150 10 SSS4A1OSF .120 10 1/2 11.0 4 1/2 4 3/4 x 25 x 3 96 39.8 29,9 23.2 18.4 33.0 24.8 19.3 15.3 150 12 SSS4Al2SF 120 10 1/2 11.0 4 1/2 4 3/4 x 26 x 3 106 34.7 25.9 19.8 16.4 29.6 22.1 16.9 13.2 150 14 SSS4A14SF .120 10 1/2 11.0 4 1/2 4 3/4 x 25 x 3 123 28,7 21.1 15.9 12.2 20.0 14.7 11.1 8.5 150 3 15 SSS4A15SF • .120 10 1/2 11.0 41/2 4 3/4 x 25 x 3 133 19,6 14.4 10.8 8.2 17.2 12.7 9.5 7.3 150 16 SSS4A16SF .120 10 1/2 11.0 4 1/2 4 3/4 x 25 x 3 137 19.1 13.9 10.3 7.7 16.9 12.3 9.1 6.8 150 0 18 SSS4A18SF .120 10 1/2 11.0 4 1/2 4 3/4 x 25 x 3 142 16.2 11.6 8.3 6.0 14.4 10.3 7.4 5.4 160 20 SSS4A2OSF' .120 10 1/2 11.0 41/2 4 3/4 x 25 x 3 152 12.9 9.1 6,5 4.6 11.7 82 5.9 4.2 200 20 SSS5A2OSF .120 10 1/2 11,0 4 1/2 5 3/4 x 25 x 3 202 21.9 15.7 11.6 8,5 19.9 14.3 10.5 77 200 ` ; 22 SSS4A22SF .120 10 1/2 11.0 41/2 4 3/4 x 25 x 3 174 11.6 7.8 6.3 3.4 10.5 7.1 4.8 3.1 200 24 SSS4A24SF .120 10 1/2 11,0 4 1/2 4 3/4 x 26 x 3 190 9,8 6.4 4.0 2.3 9,0 5.8 3.7 2.1 200 25 SSS4A25SF ° .120 10 1/2 11.0 41/2 4 3/4 x 25 x 3 208 8.7 5.6 3.6 2.1 8.0 52 3.3 2.0 200 25 SSS5A25SF .120 101!2 11.0 4112 5 314x26x3 248 15.E 10.5 7.2 4,8 14.3 9.8 6.6 4,4 200 25 SSS6A25SF .120 12 1/2 12.5 5 6 1 x 36 x 4 295 24.1 16.8 12.0 8.5 22.2 15.6 11.1 7.8 200 ii i 30 SSS5A3OSF • .120 10 1/2 11.0 41/2 5 3/4 x 25 x 3 293 8.2 4.8 2.1 -- 77 4.3 2.0 - 300 30 SSS5M30SF .188 10 1/2 11.0 4 1/2 5 3/4 x 25 x 3 369 16.2 9,5 5.8 3.1 14.2 9.0 6.4 2,9 300 30 SS56A3OSF .120 12 1/2 12.5 5 6 1 x 36 x 4 347 14.0 8.7 5.0 2,5 13.1 8.2 4.7 2.3 300 30 SSS6M3OSF .188 12 1/2 12.5 5 6 1 x 36 x 4 505 26.4 18,1 12,5 8.4 24.7 16.9 11.6 79 300 35 SSSSM35SF .188 10 1/2 11.0 4 1/2 5 3/4 x 25 x 3 480 11.8 7.1 3.8 1.5 11.1 6.6 3.6 1.4 300 35 SSS6M35SF .188 12 1/2 12.5 5 6 1 x 36 x 4 584 19,7 12.7 7.9 4.4 18,6 12.0 7.6 4.2 300 35 SS56X35SF .250 12 1/2 12.5 5 6 1 x 36 x 4 696 28.9 19,7 13,4 8,9 8.7 18.6 12.7 8.4 300 39 SSS6M39SF .188 12 1/2 12.5 5 6 1 x 36 x 4 647 15.4 9.1 4,8 1.8 14.6 8.7 4.6 1,7 300 39 SSS6X39SF .250 12 1/2 12.5 5 6 1 x 36 x 4 822 23.6 15.4 9.8 5.7 22.4 14.6 9.3 6.4 300 NOTES: 1 Catalog number done ltct include anchor bolls (BEFORE INSTALUNG ANCHOR BOLTS MAKE SURE PROPER ANCHOR 00LT TEMPLATE; IS OBTAINED FROM COOPER LIGHTING). 2 Tonon elm ar modtlning for rocrunguler arms must be specified hondholo Is iocokod 180' from single arm. 3 Shea slue, hate plata. anchor bolts and probations may vary slightly -all dimension nominal, 4 EPA's Wised on MDR prepodlee with wind normal to fiat. EPA's calculated using boss wlod notedly as Indicated plus 30% gust factor.5 Mtelrnum polo load Including Holmes and bredcota.e lmutock 036 polo logic ships a Irerdworo kid Includin0 plugs and a bronze psintrd polo cut to length and drilled on 4 sides with the M drill pattorn from a roalonal lHdbutlon senor- SSSAAISSPMa, 553442OSFMS, BSS44255FM4 and SSStA3OSPM4 available. 4 FIXTURE MOUNTING p DRILL PATTERN FIXED TENON . .t Type "M" Typo "Z° 0.0. Designation O.D. Length Number (In.) (In,) j ) ________I "-- 2378_ 4 ._ 25/16 "(58mml 4'1102mm) 3 31/2 6 6 pm__ � - 3/4" 158mm) - _ Len c gth 9 3 ...- ...... 4 - -._._ S die, holy , 2 7/16" (62mm) 2 7 /1G "(62mm) •, , , i , 4718" {124mm) V. 4 7/8" (124mm) n O , 3/4" (20mm) die, holo 11) IZ) 16mm) dia. 5/8" (16mm) die, hole (2) holes g NUMBER AND LOCATION OF ARMS (Note handholo position relative to drill locations) 1 M1 M2 M3 M4 M5 21 Z2 23 Z4 25 NOTE: SpnrIllralMns and ilk»anslons Duhloct to druerge irritants notice. a Visit our web site at www.caoperlEghting.com COOgit Lighting Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.485.4800 FAX 770.486.4801 ADHOS1780 1 r i .. • ii a COOPER LIGHTING SSS SQUARE STRAIGHT STEEL cl[aIG1I ++ SSS its m Type 11 11111111111•111011111111 70' -39' Mounting Height Project / A 4 -Bolt Anchor Base Date Comments Comments o 7 1. Prepared by ME 0 3 SPECIFICATION FEATURES . _,_ _._ -. ,_,,,,_,_ „_�._�- _ a Fixture Mounting Base Drilled or Tenon (Must specify. See fixture mounting). ASTM Grade steel base plate with ASTM A366 boas I -) - -- Fisodmonon Cover. or Drilled Shaft ASTMA500grade "B" steel shaft. Shot blasted Anchorage (Four Bolt) and painted with polyester powder coat. Anchor bolt per ASTM A578 with (2) nuts, (2) fiat washer, and (1) lodt washer. Nuts, washers and HandhoIe threaded portion of bolt are hot dip galvanlzod F HandhoIe assembly 3" x 5" on 5" and 6" poles; and 3" hook for 314" bolt, 4" hook for 1" bolt. 2" x 4" on 4" pole. 1 s i POLE COMPATIBILITY MATRIX DRILL EPA ♦ MOUNTING CONFIGURATIONS I PATTERN Sinplo 20180' 2090' 3996' 3 ®120' 4090' ', Mounting 1 PRODUCT TENON w /Ann in [21 [91 (31 (0) [4] Haight z (MH) TALON MEDIUM *mud Ow) M 1.22 2,44 2.44 3.23 3.23 3.63 E ; TALON MEDIUM (Deee Door) M 1.45 2.60 2.90 3,92 9.92 4113 I i TALON LARGE M 2.51 5.02 5.02 0.85 0.55 7.77 1- ; , IWLLERIA SQUARE SMALL ARM MOUNT' M 17 3.4 3.4 4.6 4,0 5.2 , GALLERIA SQUARE SMALL SPIDER MOUNT 2 3/8" 1.04 •• • • • - - - g GALLERIA SQUARE MEDIUM ARAI MOUNT' M 2.9 5.11 6.8 9.2 9.2 16,4 GALLERIA SQUARE MEDIUM SPIDER MOUNT 3" or 3112` 2.22 -- -• "• •• a GALLERIA SQUARE LARGE ARM MOUNT' M 4.4 8.8 9.6 13.7 13.7 15.85 6 si GALLERIA SQUARE LARGE SPIDER MOUNT 3" 01'3 1/2' 3.7 -- •• •• • • ..,. GALLERIA ROUND MEDIUM ARM mourn* N 22 4.4 5.4 7.1 7.1 7.f4 jAOndholo GALLERIA ROUND MEDIUM SPIDER MOUNT 3' 2'.. 12 6/16 " GALLERIA ROUND LARGE ARM MOUNT M 3 8 7 9.5 9.5 10.75 ) ) "'� 1 j GALLERIA ROUND LARGE SPIDER MOUNT 3" 2.8 -- -- • - -- .. o o Raw Square TRIBUTE M 1.92 3.24 3.24 4.43 4.43 6.03 o I I o (S) 0 p.M/GMLSQUARE M 3 8.2 7.2 9 9 11 .") LANDAU' M 2.7 5.4 0 0.5 8.5 9.75 Shaft Sim r (B) i CRIiUJS SMALL ARM MOUNT 2 1.19 2.38 2.313 3.57 3.57 4.17 6. CIRRUS SMAU. YOKE/SWD9t MOUNT 4" (CIS), 5" (G16) 1.13 -- •- -- "" ry �� (BC) C*RRUSMFAIIJM Z 1.7 3A 3.4 5.1 5,1 5,95 C IRRUS MEDIUM YOKE /SPIDER MOUNT 5 1 .52 -• •- -• •• •• i� P CIRRUS LARGE ARM MOUNT Z 2.36 4.72 4.72 7.08 7.08 8.26 '"'7" = }IBPI P CIRRUS LARGE YOKE/SPIDER MOUNT 6" 2.1 -. -- -. '• . 4{, i l PA CREDENZA SMALL ARM MOUNT 2 1.19 2.38 2.38 3.57 3.57 4.17 - )f l ) (AB) 1 ! 7 CREDENZA SMALL YOKE /SPIDER MOUNT 4" (WS), 5" (ZOO 1.13 - •• •- « �` ` • J r CREDENZA M EDIUM ARM MO1N4T 2 1.7 3.4 3.4 5.1 5.1 5.05 kitt F 2 4F F.•- moetS� CREDENZA MEDIUM YOKE/SPIDER MOUNT 5" 152 -- •• •• •• 11141] EI 6 CREDENZA LARGE ARM MOUNT Z 2.38 4.72 4.72 7.08 7.08 8,26 0 CREDENZA LARGE YOKE/SPIDER MOUNT 6' 2.1 -- -- •• •• •• FOUR DOLT ANCHORAGE 1 60151 Alamos 8 "wm lo/ ea" aad120' minting wdip, IatIons9" foraRIe, SAssumsla' oral IDr e0' and t20 'roaWEoca1Bpualhm.e'forallelse. (see ordering information) 3 Ammon 12" ore For 00' rid 128' mas4YWadl :Brro9wls. 0" for 31 else. IN FIN= Noontina Ballsas. 5 DC_Boit Circle "1 BP.Bolt Projection ABoAnchor Bolt D.Belt Diameter 3 Holt Dimensions i WARRING: THE USE OF UNAUTHORIZED ACCESSORIES SUCH AS BANNERS, SIGNS, CAMERAS OR PENNANTS FOR WHICH THE POLE WAS NOT DESIONED 0, VOIDS TiIE COOPER UGHTING POLE WARRANTY AND MAY RESULT IN POLE FAILURE CAUSING SERIOUS INJURY OR PROPERTY DAMAGE. UPON L REOUFST, COOPER LIG!1TING WILL SUPPLY INFORMATION REGARDING 107AL LOADING CAPACITY. COOPER UGHTING'S POLE WARRANTY IS VOID 7 UNLESS POLES ARE USED AND INSTALLED AS A COMPLETE POLE/LUMINAIRE COMBINATION. THIS WARRANTY SPECIFICALLY EXCLUDES FAILURE i AS THE RESULT OF A THIRD PARTY ACT OR OMISSION, MISUSE, UNANTICIPATED USES, FATIGUE FAILURE OR SIMILAR PHENOMENA RESULTING FROM INDUCED VIBRATION, HARMONIC OSCILLATION OR RESONANCE ASSOCIATED WITH MOVEMENT OF AIR CURRENTS AROUND THE PRODUCT. „tea A I)H081780 114111 COOPER LIGHTING o`^_ I 1 ii 3 ii 9 ' ;1 TR TRIBUTE ORDERING INFORMATION J Sample Number. MITR- SL- 400 -MT-U. 1 �( : i , j if ii I I Lamp Type Distribution Lamp Wattage 4 Options Acceewrles " 5,4p Start Metal 2F =Type II Formed MP F1 =Singlo Fuse (120, 277 or 347V MAl201 xxeD1roal Well Mount Kilt Fi Halide 2S = Type II 70 =70W only) MA7273- %XaDlracl Moral for Polo MH =Metal Halide Segmented 1004100W F2 =Double Fuso (208, 240 or480V MAl2104XCWM Mainland Pinto .. HP=High Pressure Sodium 3F =Type III Formed is0 =150W only} OAietto.XX°whotahlo o0plOa' Ann for Tonon Mount 2 3/6' 0,01 `r- 3S• Type 111 41' Quartz Rosldko (Hot Strike Only)• 'EPA. 0.381 200: 200W ham zai -xx Emoting Homo Side Milord KR E Series' Segmented EM' quartz RoaVNca with "Daley a Imp pay kdonal Houa' Sid* Shield tat for 260$ 260. 250W Relay' (Quartz lam Strikes 0 TR' Tribute (Arm included) 4F Type IV Formed p MAl223' know' Homo Sk10 Sldokd lot AS 320° 320W both hot and cold starts) qs: Type IV MA1 SS4r internal ileuav Shield Kit for 2F--/3F 3 Segmented 360' 350W EM /SC' Emorgoncy Separate. 9 MA4220' Miami Houoa Silo Mitch' Ka for AP 11 6F' Type V Funned 400W2 Circuit Mil LL' La Includod MA1010 %Xr 9k1pla7onon Adaptor fa 3 112 0.0. Tinton 6S' Seated 176' 175W S' 1 1/4" - 2 3/8" Internal Mast Arm MA1011•c *' 2 (D 190 dapreae Tonal Adayle for 312' 0.0.Tehon h SL' Spill Light 260. 250W4 Mount MA•0124X' 3 ® 120 dogrooa Teton Adaptor for 312" OA. Tanon Eiimineior 400: 400Wa• 4 TM' Trunnion Mount MA1e13•XX' 4 Q 100 dowses Tanon Adaptor la 3 117 on, Tenon iii pT' Electrical Power Tray MA1014 -%X' 2 WOO daproos Tenon Adapter lot 3 1170.D, Tan on HP.S. MA 1010 •XX' 211 120 daemon Tenon Adopter for 3 12" O.U. Talon , 70' 70W PER' NEMA Twletlock Photocontrol 100'100W R00np10do NI GOO dogma' ninon Adaptor for 312" 0.D. loran PC' Button Typo PhotoconlroN MA1047 -XX' Slnplo Town Adapter for 2 3/8'011 Tate, et 180' 150W NS* HOUSO Side Cutoff» M ea AS01a - %X' 2 ® 160 dopro Triton Adapter Mr 23/0'0.D. Tarot, 5 260' 250W MA1011i -7t %• 3 AP 120 tapes Taran Adapter for 2310 "O,0, Tenon 400: 4001A/a LA' Loss Arm (Order Mounting Sopar0101y} MA104a - %x' 4 by 00 dniaae Tone. Adaptor 101 3/8" O.D. lotion MA7040 -XXa2 WOO dylrooe Tanon Adgtwr leas 2 air O.o.Ta,at Voltam, a MA104e - XXe3 QD 00 do0,oee Tattoo Adaptor for 2 3/0' 0.0. Ta,en 1 120V =120V OA/RA1013=Shorlir0 Cep I 200v'208V OMtA101eePhQMelosaie Control t05 -285V NEMA Typo 240124DV OARIA1o27oPhotoolocalc Coasts 400V NC-MA T1rPo 277V =277V ON to RA7201oPhoolocllc Connor 347V NEMA Typo 3471/.347V. TIWSaFk'Id krocelled Vandal Windt: 11: 4801 •4861 r3 §i DT=Dual•Tep ri MT=Mutt "Tap, 0 wired 277V TT =Tripio -Tap, o wired 347V 6T =5 Tap Wired¢ 480V H P th 1 e Inds Arm and pole adaptor Included with fixture, Specify Laser Arm 'LA' option when ma'ndne ecuoaaory le ordered 'taperingly. 2 100W and below In Motel Ratdo are medium beas aoakote. All other winnow) a mogul base. 3 Roquiroe roduced onvalopo lamp. 4 176W, 260W, and 400W MN evotlablo In non -U.S. market, only, 0 Products also avallablo In non -US volumes and OW12 for Intanatlonal manias. Commit your Cooper Rep rtaentadve for averkbltny and ordevin0 IMormadon. 6T only available In 400W Mli. 0 00% efficient EISA Compkom MP 9xaraa not available In 347V or TT Voltage*. 7 Must enmity voltage. 0 0ua,10 options not ovahlablo with SL optics. 0 PC not available In 480V. 10 Nouao ddo Witold not available on OS, 6F, or SL apnea. 11 Order aeperotoly /remoter %x with actor apedteallon, 12 Not aveltnbio with SLE or i l House Silo Shdld, STOCK SAMPLE NUMBER (Lamp Included) SAMPLE NUMBER: MPTR2340 MP j TR r 23 j� /�� J a Lamp Typo odes' f Distribution Lamp Wattage MP =Pulse Start Metal Halide TR =Trihuto 23 : :Typo 11411 15=150W a HP=FIigh Pressure Sodium 2 Formed 32 2 40=400W g NOTES: 3 'Short Iodic Ilxturas are finished bronco InCludn multi -041 bailout, tamp, arm and round polo adaptor. Other ' options not mailable. Refer to elendnrd ordering topic. a Avnllebto In 150, 250 and 400 Wen. Itofor loin Stock Gukte for availability. f 1 1 i VOLTAGE CHART LAMP TYPE WATTAGE 1 DT=Dual -Tap 120277 (wired 277VI Pulse Start Metal Hallde 70,100, 150, 250, 320, 350, 400W MTuMullbTap 12012087240/277 (wired 277V1 Motel Halide 176, 250,400W Tr.Trlpls -Tap 120/277/347 (wired 347V) High Pressure Sodium 70, 100,150, 250, 400W 6T=5-Top 120/208. (wired 48011 8 1 COOR Lighting Specifications and Dimensions subject to change without notice. ADH082320 www.cooperflrrhing.torn Lumark • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30289 • TEL 770,485.4800 • FAX 770,488.4001 10/14/200912:32 :46 PM 1 t 1, diid ......_ ;,, ..... /9 ,J ® COOPER LIGHTING - LUMARI y ,,,r,�r�,l. DESCRIPTION The Lumark Tribute is the most versatile, functionally designed, universally yv� /� Y e Y Catalog ` , /�t f" 2 3/ - 5E , adaptable outdoor luminaire available. The Tribute brings outstanding performance to walkways, parking lots, roadways, loading docks, building r r areas, and any security lighting application. U.L. listed and CSA certified for i Project . I y/n c 4, o wet locations. Ea ' 'r { Giamments ✓, 4 r , 0 2 1 2010 p repared b 0 0LI f E :r . . l SPECIFICATION FEATURES c Construction field rotatable in 90° increments Standard single carton packaging ,e, . and offered standard with of housing, square pole arm and Rugged one -piece die -cast gr q P aluminum housing and door mogul -base lampholders for round pole adapter allow for , 200-400W assemblies or consolidated product arrival to site. r� ° e frame. One -piece silicone gasket protects the optical chamber from medium -base lampholders for Optional Internal mast arm mount w performance degrading contami- 150W and below. accepts a 1 1J4" to 2 3/8' O.D. ! pants. One (1) stainless spring horizontal tenon, while a 4 -bolt in Electrical clam latch and two (2) stainless hinges clamping mechanism secures ;: Bllt d ltd l l Ballast and related electrical cl allow toolless opening and fixture. Cast -in leveling guides removal of door frame. componentry are hard mounted to provide +1 -5° vertical leveling die -cast housing for optimal heat adjustment. C Reflector transfer and operating efficiency. Choice of nine (9) high efficiency Optional swing -down galvanized Finish - 0 optical distributions, including five steel power tray with integral Housing and arm finished In a 5 '0 (5) segmented optical systems handle and quick disconnects stage premium TGIC bronze TR constructed of premium 95% allows tray to be completely polyester powder coat paint. ' reflective anodized aluminum removed from housing providing Optional colors include black, grey, TRIBUTE sheet Optical segments are rigidly mounted ample room for fixture installation white, dark platinum and graphite ` "r;: inside a thick gauge and maintenance, metallic. RAL and custom color aluminum housing for superior matches available, 70 - 400W r M protection. All segment faces High Pressure Sodium ¢) Extruded 8" aluminum arm are clean of rivet heads, tabs or Pulse Start Metal Halide fi other means of attachment which features internal bolt guides for Metal Halide may cause streaking in the light easy positioning of fixture during ii........ distribution. Optical modules are installation to pole or wall surface. AREA LUMINAIRE 'F DARK SKY F CC COMPLIANT ?waist F DIMENSIONS Il TECHNICAL DATA D' _ , . ___ --- r __ -. UL Wot Locations Lined 6 I CSA Certified g 0 1/2" EISA Compliant Q tiM 3 —J —W- ENERGY DATA Hl.Reaatance Ballast Input wntta 22" I559mm1 ( a' (203mnt 70W HPS HPF 196 WMIC) 100W HPS HPF (130 Watts) ' 160W HPS HPF 1190 Watts) 150W MP HPF (105 Moto) CWi Ballast input Watts e 16 1/2` t394mml 250W HPS HPF (300 Watts) CWA Ballast Input Watts 176W MH HPF (210 Watts) 200W MP HPF (227 Watts) tg 200W HPS HPF 1260 Walla) 1 DRILLING PATTERNS 260W MH HPF (296 Watts) 250W MP HPF (283 Watts) W i TYPE "M" WALL MOUNT TRUNNION MOUNT 320WMP HPF (305Walta)© 360W MP HPF (397 Watts} 1I 5 18" �9 c I ' 1" 400W MP HPF (452 Watts) ¢J s 1 C 159ntm) 12 " [26mm) l 400W MH HPF (465 Wattol moon 314" 120mm1 s 1305mml U 4coW HPS HPF (465 Wefts} C AI d1'. hold 4716" 2 7116" It2Amml o 1124mm1 EPA e 10 1/2' Effective Projected Area: 1S ti. Fl,) 4 7/9" 1124mm1 1267mm1 Without Arm :1.19 k I 1n6' {12mm) 13/32" x314 " t20mml 111mm1 SHIPPING DATA n {2) 5M [16mmi •9118 il4mml g slot (2) slot Approximate Not WOlght: J� _ die, bolas I 0 1 /2" 165mnH � L J Cie. Hole (A} 39Iba. (17,73 kgs.) 9 L 11,2" 1203n 139mm1 1 3" 177mm) ' 1 Cono �/// tern y ult COOZ Lighting Specifications and Dimensions subject to change without notice. ADH0a2320 wwwceo ir tent your representative for addition? options and (inlatrea. 10/14/2009 12:32;45 PM xJ 9• 1 , ♦ � -.. .ie r te a - V ,. 1 4 .;r t ". t4 5 4 ...e4F. r.4 �, � '' '''''';'1,". .G.. ... o- 5. 1 ,l' . * t r� r ':‘,7,::;74,1i! troy T .spa, Y. yer4 b � n ' `t 4 a 0 c t '.: P. • r n, a p Y W emu" ■ .�, .. at .. - r PHOTOMETRICS (Complete IES files available at www.cooperlighting.com) 4 4 4 4 • FootcandleTable 3 - 3 3 nob. 3 Select mounting height and read across for footcandle values of each isofootcandle line. _i♦�� _� Distance in units of mounting height. -'��,� 2 ��_ ^^ � JJ _— 2 �!\ I Mounting Footcandle Values for �rMMEN 1 �-'11 1 �-•� 1 1 1 Height Isofootcandle Lines ■, III B C D E • E A C D � A / B C D E ABC D E 20' 3.00 1.50 0.75 0.30 0.15 J// ° 0 30' 2.00 1.00 0.50 0.20 0.10 _ % i i !_ /! / ' — %/% 30' 7. 38 1.69 0.34 0.13 0.06 ` mo d JJ_ �� / / /II 7 1.38 ^/, 2 � m• 2 2 v: 2 ••■ 3 3 _ 3 3 4 4 4 4 0 1 2 3 4 5 0 1 2 3 4 5 0 1 2 3 4 5 0 1 2 3 4 5 PFT12523P25 PFT13223P25 PFT14023P25 PFT14023H25 250 —Watt MP 320 —Watt MP 400 —Watt MP 400 —Watt HP 22,000 —Lumen Clear Lamp 30,000 —Lumen Clear Lamp 40,000 —Lumen Clear Lamp 50,000 —Lumen Clear Lamp Type Ill Formed Type Ill Formed Type Ill Formed Type IV COOgIt Lighting Specifications and Dimensions subject to change without notice. ADH0S2319 www.coopedightlng.com Lurk • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 10/14/2009 12:33:28 PM ORDERING INFORMATION PFT TRIBUTE AND POLE COMBO Semple Number. PFT1153H75/N /AI! I I II L I[�I , I I II , II Series Number of Lamp Distribution L Type ' Pole Height Zone Options 5 PFT Tribute Pole Fixtures Wattage 23 =Type li /Ill Pulse Start Metal tg=15' g MPH Wind Zone [Options Anchor Bolts (Used when Combo 1 =1 15=150W 4F= TypelV Halide 2O=2 0 =100 MPH Wind Zone ordered separately) 2=2 25=250W Formed H=High Pressure 25=25. _320VV Sodium 30 =30' 40 =400W Not..: t 8 inch arm and pole adapter included with fixture. Lamp Included with all PFT configurations. 2 N/AB models available by specifying N/AB (lb PFT11523P15WAB). • Note: Supplied with Multi-Tap ballast 120/208/240/277 (wired 277V) with square straight steel shaft, anchor bolt., template, base cover end hardware. Lamp Source /Number of Fixtures Pole Height Wattage Distribution 80 MPH 90 MPH' 100 MPH' HIGH PRESSURE SODIUM (HPS) Single Fixture 150W HPS Type II /III PFT11523H15 PFT11523H15' PFT11523H15' TypelV PFT1154FH15' PFT1154FH15' PFT1154FH15' 20' Pole 250W HPS Type II /III PFT12523H20' PFT12523H20' PFT12523H20' Type IV PFT1254FH2O' PFT1254FH20' PFT1254FH20' 400W HPS Type 11 /111 PFT14023H20 PFT14023H20' PFT14023H20' - I I Type IV PFT1404FH2O' PFT1404FH20 ' PFT1404FH20 ' 25' Pole 250W HPS Type II /III PFT12523H25' PFT12523H25' PFT12523H25' Type IV PFT1254FH25' PFT1254FH25 PFT1254FH25 — 400W HPS TypeIt /III PFT14023H25' PFT14023H25' PFT14023H25' TypelV PFT1404FH25' PFT1404FH25' PFT1404FH25' 30' Pole 250W HPS Type II /III PFT12523H30' PFT12523H30' PFT12523H300' Type IV PFT1254FH30' PFT1254FH30' PFT1254FH300• 400W HPS TypeIt /III PFT14023H30' PFT14023H30' PFT14023H300• Type IV PFT1404FH30' PFT1404FH30' PFT1404FH300' Dual Fixture 15' Pole 150W HPS Type II/111 PFT21523H15' PFT21523H15 PFT21523H15 TypelV PFT2154FH15' PFT2154FH15 PFT2154FH15' 20' Pole 250W HPS Type II /III PFT22523H20' PFT22523H20' PFT22523H20' Type IV PFT2254FH20' PFT2254FH20' PFT2254FH20' — 400W HPS TypeIt /Ill PFT24023H20' PFT24023H20 PFT24023H20' I I_ J I Type IV PFT2404FH2O' PFT2404FH20' PFT2404FH2O' 25' Pole 250W HPS Type I1 /III PFT22523H25' PFT22523H25' PFT22523H250' Type IV PFT2254FH25' PFT2254FH25 PFT2254FH250' — 400W HPS Type 11/111 PFT24023H25' PFT24023H25' PFT24023H250' Type IV PFT2404FH25' PFT2404FH25' PFT2404FH250' 30' Pole 250W HPS Type II /Ill PFT22523H30' PFT22523H309 PFT22523H300' Type IV PFT2254FH30' PFT2254FH309• PFT2254FH300' 400W HPS Type 11/111 PFT24023H30' PFT24023H309 PFT24023H300' PULSE START METAL HALIDE (PSMH) Type IV PFT2404FH30' PFT2404FH309 • PFT2404FH300` Single Fixture 15' Pole 150W PSMH Type II /III PFT11523P15' PFT11523P15 PFT11523P15' Type IV PFT1154FP15' PFT1154FP15' PFT1154FP15' 20' Pole 250W PSMH Type II /III PFT12523P20' PFT12523P20' PFT12523P20' Type IV PFT1254FP20' PFT1254FP20' PFT1254FP20 320W PSMH Type II /III PFT13223P20' PFT13223P20' PFT13223P20' Type IV PFT1324FP20' PFT1324FP20' PFT1324FP20' 400W PSMH Type II /III PFT14023P20' PFT14023P20' PFT14023P20 Type IV PFT1404FP20' PFT1404FP20' PFT1404FP20' ' I 25' Pole 250W PSMH Type II/III PFT12523P25' PFT12523P25' PFT12523P25' Type IV PFT1254FP25' PFT1254FP25' PFT1254FP25' 320W PSMH Type II /III PFT13223P25' PFT13223P25' PFT13223P25 — Type IV PFT1324FP25' PFT1324FP25' PFT1324FP25 400W PSMH Type II /III PFT14023P25' PFT14023P25' PFT14023P25' Type IV PFT1404FP25' PFT1404FP25' PFT1404FP25' 30' Pole 250W PSMH Type II /III PFT12523P30' PFT12523P30' PFT12523P300 • Type IV PFT1254FP30' PFT1254FP30' PFT1254FP300 320W PSMH Type II/III PFT13223P30' PFT13223P30' PFT13223P300' Type IV PFT1324FP30' PFT1324FP30' PFT1324FP300' 400W PSMH Type I1 /III PFT14023P30' PFT14023P30' PFT14023P300' Type IV PFT1404FP30' PFT1404FP30' PFT1404FP300' Dual Fixture 15' Pole 150W PSMH Type II /III PFT21523P15' PFT21523P15' PFT21523P15 Type IV PFT2154FP15' PFT2154FP15' PFT2154FP15 20' Pole 250W PSMH Type II /III PFT22523P20' PFT22523P20' PFT22523P20' Type IV PFT2254FP20' PFT2254FP20' PFT2254FP20' 320W PSMH Type II /III PFT23223P20' PFT23223P20' PFT23223P20' Type IV PFT2324FP20' PFT2324FP20' PFT2324FP20' 400W PSMH Type ll /III PFT24023P20' PFT24023P20' PFT24023P20' Type IV PFT2404FP20' PFT2404FP20' PFT2404FP20' — 25' Pole 250W PSMH Type II /III PFT22523P25' PFT22523P25' PFT22523P250' I I___ _1 I Type IV PFT2254FP25' PFT2254FP25' PFT2254FP250' 320W PSMH Type II /III PFT23223P25' PFT23223P25' PFT23223P250' Type IV PFT2324FP25 PFT2324FP25' PFT2324FP250' 400W PSMH Type I1 /III PFT24023P25' PFT24023P25' PFT24023P250' Type IV PFT2404FP25' PFT2404FP25' PFT2404FP250 30' Pole 25OW PSMH Type I /III PFT22523P30' PFT22523P309' PFT22523P300' Type IV PFT2254FP30' PFT2254FP309• PFT2254FP300' 320W PSMH Type II/III PFT23223P30' PFT23223P309 • PFT23223P300 • Type IV PFT2324FP30' PFT2324FP309• PFT2324FP300• Refer to In Stock Guide for availabilty. 400W PSMH Type II /III PFT24023P30' PFT24023P309 • PFT24023P300 ° NOTES: 1 0 or 9 are noted where needed to designate a heavier gauge pole. Type IV PFT2404FP30' PFT2404FP309' PFT2404FP300' 2 Supplied with 4A Square Straight Steel shaft (SSS), anchor bolts (A81 I, template (TMP1) Hardware and base cover. 15' combo SSS4A15SFM4, 20' combo SSS4A2OSFM4 and 25' combo SSS4A25SFM4. 3 Supplied with 5A Square Straight Steel shaft ISSSI, anchor bolts IAB1), template ITMP1) Hardware and base cover. 25' combo SSS5A25SFM4 and 30' combo SSS5A3OSFM4. 4 Supplied with 5M Square Straight Steel shaft (SSS), anchor bolts (A81 I. template (TMP1) Hardware and base cover. 30' combo SSS5M3OSFM4. 5 Supplied with 6M Square Straight Steel shaft ISSS), anchor bolts (A83), template ITMP2) Hardware and base cover. 30' combo SSS6M3OSFM4. Lighting Specifications and Dimensions subject to change without notice. ADH082319 www.cooperilghdng.com Lumark • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 90289 • TEL 770A86.4800 • FAX 770.486A801 10/14/2009 12:33:28 PM QE COOPER LIGHTING - LUMARK® DESCRIPTION The Lumark Tribute Pole/Fixture Combo features all you need for easy Catalog # -■ Type selection and installation for poles and fixtures. Including the quality, • die -cast Triubte area luminaire and 8° arm complete with lamp, square straight steel pole and necessary anchorage. Available in single or dual Project fixture combinations. The Tribute/Pole Combo is ideal for parking areas, access roadways and Comments Date other general off street area/site lighting applications. Prepared by SPECIFICATION FEATURES Construction Electrical Pole Rugged one -piece die -cast alumi- Ballast and related electrical Shaft is one piece construction ' num housing and door frame componentry are hard mounted to ASTM A500 grade "B" steel, shot ,; V 1 ,, finished in dark bronze polyester die -cast housing for optimal heat blasted and finished in dark bronze z.- . �'° powder paint. One -piece silicone transfer and operating efficiency. polyester powder coat. Anchor '' gasket protects the optical base is fabricated from ASTM chamber from performance Mounting grade steel. ASTM A366 steel full , degrading contaminants. One (1) Extruded 8" aluminum arm base cover is provided to enclose stainless spring latch and two (2) features internal bolt guides for base plate and anchor bolts. stainless steel hinges allow easy positioning of fixture during Anchor bolts are per ASTM A576 toolless opening and removal of installation to pole. with (2) nuts, (2) flat washers, and door frame. U.L. Listed and CSA (1) lock washer. Hardware and certified for wet locations. Finish threaded portion of bolt are hot dip Housing and arm finished in a galvanized. 3" hook for 3/4" bolt. 4" Reflector 5 stage premium TGIC bronze hook for 1" bolt. PFT Hydroformed anodized aluminum polyester powder coat paint. reflector offered in an adjustable TRIBUTE AND Type II/III or a Type IV distribution. Optical modules are field rotatable POLE COMBO in 90° increments and offered standard with medium or DARK SKY C • mogul -base lampholders. COMPLIANT Full 150 - 400 W High Pressure Sodium Pulse Start Metal Halide 15' -30' LAMP TYPE WATTAGE Square Straight Pulse Start Metal Halide (MP) 150, 250,320, 400W Steel Pole High Pressure Sodium (HP) 150, 250, 400W 11•11111111•111•■• POLE AND FIXTURE COMBO DIMENSIONS e I 812' ° (165mm1 .i TECHNICAL DATA (Fixture) 22' (559mm] 1 8' (203mmp U.L. Wet Location Listed CSA Certified EISA Compliant IT 1512' [384mm] ENERGY DATA Hi- Reactance Ballast Input Watts 150W HPS HPF (190 Watts) 150W MP HPF (185 Watts) CWA Ballast Input Watts 250W MP HPF (283 Watts) DRILLING PATTERNS 250W HPS HPF (295 Watts) 320W MP HPF (365 Watts) QE TYPE °M" 400WMPHPF(452 400W HPS HPF (465 Watts) 2 5/16" (59mm] EPA mum 3/4" (20mm) � Effective Projected Area: (Sq. Ft.) dia. hole I 2 7/16" (124mm] ° ° O Single:1.62 I Dual: 3.24 4 7/8[124mm] Base View ° ° I ] SHIPPING DATA (2) 5/8" [16mm) Approximate Net Weight: dia. holes 39 lbs. (17.73 kgs.) ,° t . /Pi II ° CIMIeR Lighting Specifications and Dimensions subject to change without notice. ADH082319 www.cooperlighting.com Gamin your representative for additional options and finishes. 10/14/2009 12:33:28 PM CIMARNEY ELECTRICAL SERVICES !r�C, 660 Riverside Drive, P.O. Box 60453, Florence, MA 01062 413- 584 -0737 Fax: 413 -587 -0737 www.marneyelectric.com August 4, 2010 YMCA Proposed Sidewalk Light PHOTOMETRIC FILENAME : CSB3- 70PS -XXX CLEAR (6692),IES DESCRIPTIVE INFORMATION (From Photometric File) AccuLite, Juno Lighting Group, Inc. CSB3- 70PS -)00( AccuLite Quasar General Purpose Area Luminaire, Type III Distribution One Piece Die Cast Aluminum Housing, High- Performance Segmented Reflector, Clear Flat Tempered Glass Lens, Dark Sky Association Seal of Approval TEMPLATE SPECIFICATION Horizontal Footcandles Scale: 1 Inch = 10 Ft. Light Loss Factor = 0.75 Lumens Per Lamp = 5040 Total Lamp Lumens = 5040 Mounting Height = 16.00 Ft Maximum Calculated Value = 3.11 Fc Arrangement: Single LUMINAIRE LAYOUT INFORMATION X Y Z Orient Tilt Roll Spin Tilt Correction 1 0.00 0.00 16.00 0.00 0.00 0.00 0.00 1.00 Photometric Toolbox Professional Edition (c) copyright 1995 -2009 by Lighting Analysts, Inc. Page 2 Calculations based on published IES Methods and recommendations. Results derived from content of manufacturers photometric file. 0 111. COOPER Lighting Photometric Toolbox .5 1 2 } 1> \ 1 1 .2 AccuLite, Juno Lighting Group, Inc. Horizontal Footcandles CSB3- 70PS -X0X Scale: 1 Inch = 10 Ft. AccuLite Quasar General Purpose Area Luminaire, Type Light Loss Factor = 0.75 III Distribution Lumens Per Lamp = 5040 One Piece Die Cast Aluminum Housing, Total Lamp Lumens = 5040 High- Performance Mounting Height = 16.00 Ft Segmented Reflector, Clear Flat Tempered Glass Lens, Maximum Calculated Value = 3.11 Fe Dark Sky Association Seal of Approval Arrangement: Single Photometric Toolbox Professional Edition (c) copyright 1995 -2009 by Lighting Analysts, Inc. Page 1 Calculations based on published IES Methods and recommendations. Results derived from content of manufacturers photometric file. r H3.2 Dimensions L W H 70W - 400W 16 3/8" 16 3/8" 7 3/8" Pole Drilling Pattern - Bracket Mounted Luminaires 875W - 1000W 23 3/4" 23 3/4" 10 1/4" 875W & 100CW 70W - 400W bracket mount bracket mount + 1- 3/4 "-• 0 13/32" Wall Brackets 0 1/2" - 05/8" [1w8-1 -Colo 2 (x4) 3" " Tenon, 2 3/8" 0 . D . rd t^ MIN I ..1�1 2" . 1" MIN 2" CSB -WB -Color For bracket mounted T luminaires i 0 Max.400W 0 EPA & Weight Includes 1.2 drag factor and brackets ■ ■ 'l ■ ■ •... III ■ �_■ ■ 400W EPA 1.51 sq.ft. 3.02 sq.ft. 3 02 sq.ft. 3.84 sq.ft. 5.12 soft. Weight 36 lb. 72 lb. 72 lb. 108 IL 144 lb. 1000W EPA 2.90 sq .ft. 5.80 sq.ft 5.80 sq.ft. 8.70 sq.ft. 11.6 sq.ft. Weight 781b. 1 551b 1551b. 233 lb. 3101b. n 0CCCCCCCC Optical Assembly CSB2 CSB3 CSB3 CSB4 FT FT _ Lamp 400PS 400PS 1000MH 400PS 400PS 1000MH 90° .\ FVH g0 Forward Light FH Luminaire Lumens 14,762 17,236 42,004 19,356 18,533 49,034 ,, FM 60° % Lamp Lumens 36.9% 43.1% 39.0% 48.4% 46.3% 45.5% FL \ Low FL (0' - 30 °) 8.0% 8.8% 7.6% 8.9% 8.0% 9.0% 30° Mid FM (30° - 60 °1 19.2% 73.0% 18.8% 23.3% 23.8% 28.1% 0° -nadir High FH (60' -80 °) 9.6% 11.1% 12.5% 15.3% 14.3% 8.3% Very High FVH (80° - 90°) 0.1% 0.1% 0.1% 0.8% 0.2% 0.1% Back Light 90° 8VH �. Luminaire Lumens 71,381 11,631 25,261 9,487 3,839 11,471 B0° BH % Lamp Lumens 28.5% 29.1% 23.4% 23.7% 9.6% 10.6% 60° BM / ' Low EL (0' -30 °) 7,7% 8.5% 7.1% 7.9% 4.6% 5.5% BL Mid BM (30 ° -60 °) 16.0% 17.0% 117% 138% 4.5% 4.6% 30° High BH (60' -80 °) 4.6% 3.5% 2.6% 2.0% 0.4% 0.6% 0° -nadir Very High BVH (80 ° -90 °) 0.1% 0.0% 0.0% 0.0% 0.0% 0.0% Up Light 100" OH 100° Luminaire Lumens 0 0 0 1 0 0 90' ur r 90' % Lamp Lumens 0.0% 00% 0.0% 0.0% 0.0% 0.0% Low UL (90° - 100') 00% 0.0% 0.0% 0.0% 0.0% 0.0% High UH (100' - 180 °) 0.0% 0.0% 0.0% 00% 0.0% 0.0% 0" (nadir) Trapped Light Luminaire Lumens 13,857 11,133 40,534 11,156 17,628 47,295 % Lamp Lumens 34.6% 27.8% 37.6% 27.9% 44.1% 43.9% • 11 1300 S. Wolf Road • P.O. Box 5065 • Des Plaines, IL 60017 -5065 • Phone (847) 827 -9880 • Fax (847) 827 -2925 s � 220 Chrysler Drive • Brampton, Ontario • Canada L6S 6B6 • Phone (905) 792 -7335 • Fax (905) 792 -0064 :,,Sd+ne.der.,“., Visit us at www.junolightinggroup.com Printed in U.S.A. ©2006 Juno Lighting, Inc. H7.3.1 AccuLite QUASAR' Project: PARKING, ROADWAY Fixture Type_ & AREA LIGHTING Location: CSB and FT Series, Magnetic Ballast Contact/Phone: Cat. No.: PRODUCT DESCRIPTION Tt t rubnq cbrrotu Nit/ Pq of Engineered to provide a rugged, high performance Accessories: luminaire that is both attractive and affordable. The Quasar'" luminaire provides the light control demanded by the specifier, while offering the end user reliability and long term economy. The Quasar'" luminaire is ideal for installation in a wide variety of facilities ranging from large shopping malls to small plazas; business parks, ommercial ' complexes and office buildings; college and university campuses; and high or low rise apartment buildings. Ballasts Cool operating, the ballast is mounted PRODUCT SPECIFICATIONS directly to the cast housing for maximum heat dissipation • HPF ballasts are suitable for low "Dark Sky" Cut -Ofir Listed with the International Dark temperature starting • Probe Start MH -30° C, Sky Association as a full cut -off luminaire Pulse Start MH -40° C, HPS -40° C Optics High - performance, segmented reflector • IES Finish Baked polyester powder coat Type II, Ill, IV and forward throw distributions • Clear flat EISA AccuLite 175W 400W Pulse Start MH tempered glass lens luminaires are designed and built to Energy Construction One piece die cast aluminum housing Independance & Security Act standards • Permanently attached hinged door is secured with four bolts for maximum weather -proof integrity Lampholder Specification grade porcelain, mogul • Gasketed lens base Mounting Square pole bracket, yoke and slipfitter Certification Certified to UL1598 /CSA C22.2 250 • IDA Full Cut -Off • Suitable for wet locations PRODUCT CODES Series Lamp Options Distribution (Watts/Types) Ballast Mounting Accessories Max 400W Pulse Start Metal Halicfet Magnetic Ballast Square Pole Bracket Lamp CSB2- IFS Type II Mogul Base - art Quad Tap Max 400W - CL Coated HID lamp CSB3- IES Type III 70PS, 100PS, 150PS ED28 120V, 208/ 240V 277V No suffix included - L Clear HID lamp CSB4- IES Type IV Photocontrol r200PS, 250P5, 320P5 ED28 TT Tr' Tap 8 /5-t000W FT Forward Throw ® 120V, 277V, 347V No suffix Order bracket Replace suffix " -OT" and " -TT" 350P5, 400PS ED28 with the line voltage (Max 347V) 1000W - 480# 480V separately - See Accessories CSB3- IES Type III 875PS, 1000PS BT37 - PC Button type Round Pole Bracket FT Forward Throw Probe Start Metal Halide - R Indicate pole diameter Photocontrol Receptacle Mogul Base Photocontrol supplied by others r {175MH, 250MH, 400MH ED28 - SF - Slipfitter - PCR 480V, receptacle only 2" Tenon, 2 3/8" O.D. Fuse Holder 1000MH BT56 - TRN - Yoke Supplied with fuse High Pressure Sodium On multi -tap ballasts indicate Mogul Base line voltage 150HP ED23.5 - F1 Single pole - Line to neutral 250HP, 400HP ED13 - F2 Two pole - Line to line 1000HP E25 Color No Suffix Bronze, standard - BL Black ACCESSORIES - SL Silver Order separately - WH White Hron',e finish, mange "-a7" black ' -BL" or w -oe " -WH" Designer Colors Consult Factory Description Cat. No. Description Cat. No. Mounting Arm - 875W & 1000W Wall Mounting Brackets t Metal Halide • IES Type III, bronze CSB3- 1000AM -BZ For slipfitter mounted luminaires EISA: 200W - 400W Pulse Start MH meets Energy Forward Throw, bronze FT- 1000AM -BZ 2" IPS (2 3/8" OD) WB -1 -BZ Independence Security Act (EISA) requirements. Vandal Shield For bracket mounted luminaires 150W wet location luminaires are EISA exempt. Max 400W Models CSB -LS400 Max 400W CSB -WB -BZ # Lamp Socket Protector: 1000W Models CSB- LS1000 House Side Shield - External Required in Canada when using 208V, 240V & 480V - add suffix " - LSP." For CSB2, CSB3 & CSB4 models 70W thru 400W CSB H55400 • ITEMS MARKED WITH A MAPLE LEAF ARE 0). ONLY AVAILABLE IN CANADA 875W & 1000W CSB HSS1000 4C0W Probe Start MH lamps do not meet the Juso Lrcnnmr Greoua EISA standard. s�neeraer,i . 0 Lumen Essentials Date : 27 Sep 2010 Luminaire Title : YMCA. Springfield IES Filename : CSB3- 70PS -XXX Clear.IES Desc : Cut off Description : CSB3- 70PS -XXX AccuLite Quasar General Purpose Area Luminaire, Type Ill Distribution (1) - Horizontal 70W Clear ED 17 Pulse Start MH For : Rick Light Loss Factor : 0.75 By : Langlais Number of Lamps : 1 Lamp Lumens : 5040 Ims Luminaire Watts : 90 VV If19°' 0 18 36 Scale: feet Arrangement Magnification: 100 % I i I i 1 Visible Area - -52 Avg: 0.16 Max: 3.67 Min: 0 --34 . • - -16 — 2 E _ ___20 - -38 -56 -4 -16 ? 10 38 56 74 FlashOutdoor 1 .33 Build: 721 -3070 I 02004 -2010 Lighting Analysts, Inc. I Calculations based on IESNA methods and recommendations. I Results derived from content of photometric files. It ' H7.8.3 AccuLite WIND MAP BASIC WIND VELOCITIES MILES PER HOUR cl �} ` Y ' 1 04� �'' 70 l � C 70 & 60 9 40 '0 6 70, 50 90 e \ 60 r i � 90 80 f 70 `� 70 • ilikr � 90 r , 50 tic This map is intended as 70 a general guide. Check your so 60 11111 460 X local area for unique 7 50 o 6o 50 6o 60 go j ' wind conditions 1 _ . 60 1 70 United States Values are based 4. -� on annual extreme -mile 30 feet �'� 70 70 above the ground and 50 -year eo i Ale�(; eo 4 ,, mean recurrence interval / Hawaii Hawaii has an 80 MPH -�- ..,,,v-, � l ■ wind velocity , _ / Canada Based on peak mean hourly wind speeds for a 30 -year return peri- • 70 5.11 od, 30 feet above the ground. 70 j ` Caution Caution is advised in using to ! to wind velocity contours in special wind �' 0 0 areas such as mountainous areas and sa _'`J 8 0 '� areas around the Great Lakes � -.�.+ 90 ill, 100 ,i10 110 0 1"" 7 110 EPA & Weight Includes 1.2 drag factor and brackets 1 Luminairet 2 Luminairef 3 Luminairet 4 Luminairef EPA/Weight EPA/Weight EPA/Weight EPA/Weight Alari'" & Alan "+ Al & AP1 175W 0.8 sq. ft. / 28 lb. 1.6 sq. ft. / 56 lb. 2.4 sq. ft. / 84 lb. 3.2 sq. ft. / 112 lb. A2 & AP2 400W 1.2 sq. ft. / 49 lb 2.4 sq. ft. / 98 lb. 3.6 sq. ft. / 147 lb. 4,8 sq. ft. / 196 lb. Quasar CSB & FT 400W 1.51 sq.ft. / 36 lb. 3.02 sq.ft. / 72 lb. 3.84 sq.ft. / 108 lb. 5.12 sq.ft. / 144 lb. 1000W 2.90 sq.ft. / 78 lb. 5.80 sq.ft. / 15516. 8.70 sq.ft. / 233 lb. 11.6 sq.ft. / 310 lb. Aries AVP 400W 3.38 sq.ft. / 55 lb. 6.61 sq.ft. / 104 'b. 9.89 sq.ft. / 154 lb. 13.12 sq.ft. / 203 lb. 13.12 sq.ft. / 259 lb. AVR 400W 2.78 sq.ft. / 48 lb. 5.41 sq.ft. / 90 lb. 8.09 sq.ft. / 133 lb. 10.72 sq.ft, / 175Ib. AVS 400W 2.63 sq.ft. / 80 lb. 5,11 sq.ft. / 160 b. 7.64 sq.ft. / 148 lb. 10,12 sq.ft. / 195 lb. Accuflood FLS Max 175W 0.71 sq. ft. / 16 lb. 2.42 sq. ft. / 53 lb. 3.73 sq. ft. / 82 lb. 5.14 sq. ft. / 108 lb. EFM Max 400W 1.20 sq. ft. / 28 lb. 3.40 sq. ft. / 77 lb. 5.20 sq. ft. / 118 lb. 7.1 sq. ft. / 156 lb. SFL Max 400W 1.90 sq. ft. / 30 lb. 4.80 sq. ft. / 81 lb. 7.30 sq. ft. / 124 lb. 9.9 sq. ft. / 164 lb. NF Max 400W 2.20 sq. ft. / 36 lb. 5.40 sq. ft. / 93 lb. 8.20 sq. ft. / 142 lb. 11.1 sq. ft. / 188 lb. FLM Max 400W 2.30 sq. ft. / 40 lb. 5.60 sq. ft. / 101 lb. 8.50 sq. ft. / 154 lb. 11.5 sq. ft. / 204 lb. FLC Max 1000W 4.70 sq. ft. / 73 lb. 10,40 sq. ft./167 lb. 15.70 sq. ft. /253 lb. 21.1 sq. ft./336 lb. Caribe RBF Max 175W 0.80 sq. ft. / 19 lb. 2.60 sq. ft. / 59 lb. 4.00 sq. ft. / 91 lb. 5.5 sq. ft. / 120 lb. Max 400W 1.98 sq. ft. / 54 lb. 4.96 sq. ft. / 108 lb. 7.54 sq. ft. / 162 lb. 10.22 sq. ft. / 216 lb. Flood -Lux 0.56 sq. ft. / 8 lb. 2.12 sq. ft. / 37 lb. 3.28 sq. ft. / 58 lb. 4.54 s ft. / 76 lb. CF Max 150W q q Sport-Pro • 2.80 sq. ft. / 56 lb. 6.60 sq. ft. / 133 lb. 10.00 sq. ft. / 202 lb. 13.5 sq. ft. / 268 lb. 411). SP Max 1500W q q „ur,o Lis,snnr, C.nu , t Includes bracketry SQUARE 10 H7.8.2 Pole Selection Process 1. Site 1 b. Special Wind Regions 3: Calculate Weight (Lb.) 5: Calculate Pole Suitability: • Installation and local area • Locations such as mountainous Luminaire Cat. #: N: EPA (Line L): 0.0 ft` conditions can dramatically areas and areas surrounding the Bracket Cat. #: P: EPA (Line E): o.o ft' effect lighting pole Great Lakes exhibit wind performance velocities considerably higher F: Luminaire Weight: lb. 0: Weight (Line M): 0.0 lb. • Excessive vibration may result than the surrounding locales from some wind and mounting • Consult local authorities to G: Luminaires /Pole: R: Weiqht (Line K): 0.0 lb. considerations determine maximum wind H: (Multiply F X G) S: Calculate • Only individuals with local velocities and select equipment Luminaire Weight: o.o lb. (Subtract : N - P) 0.0 knowledge who have observed accordingly T: Calculate or inspected the site can lc. Wind velocity J: Bracket Weight: lb. (Subtract : Q - R) 0.0 effectively evaluate site specific ❑ 80 MPH ❑ 90 MPH K: (Add: H + J) issues ❑ 100 MPH Weight (Total): 0 lb. If either Line "5" or Line "T" is la. Wind Speed ❑Other MPH less than zero, the pole selected is • Determine the site location and 2: Calculate Effective Projected 4: To select the correct pole not suitable steady wind velocity. (See Basic Area (EPA) • Use the wind conditions from Caution Wind Velocities map page 869) Luminaire Cat. #: Step 1, then compare the • These selection methods are • If the location falls between the Bracket Cat. #: maximum allowable EPA and guidelines only Isotach bars or on the 70 MPH weight (see catalog) for the • Juno Lighting Group assumes or 90 MPH Isotach bar, use the ft , Luminaire EPA: ft' style, material and height of the no responsibility for selection next highest wind velocity pole required with the EPA and and recommends you consult (i.e., 80 MPH or 100 MPH) B: Luminaires /Pole: weight calculated in steps 2 qualified professionals for • If the wind exceeds 100 MPH, C: EPA (Multiply A X B) (line E) & 3 (line K) verification of overall system consult the factory (all Luminaires): 0.0 ft' • The EPA and weight of the design, site suitability, poles must be equal to, or foundation considerations and D: Bracket EPA: greater than the totals applicable code and regulatory (see below) ft calculated in steps 2 & 3 compliance E: Total EPA (Add: C + D) Pole Cat. #: Overloading (Luminaires & Brackets) 0.0 ft= L: EPA (Max): ft • Do not overload poles by M: Weight (Max): lb. attaching flags, banners or any items that can add excessive wind or mechanical load to designed pole assemblies Tenon Mounting Brackets 1 Luminaire 2 Luminaires 3 Luminaires 4 Luminaires Bullhorn Style @180' @180° @180° Order brackets separately, indicate color _ i.-3 0"_+1 _ I* 2 ' 6"÷I* 2' 6 ” 4 'i _1 6" 6g+14-2' 6"-0-1 1'0 "k j 1'0 " j 1'0 "k 3 lJ Mounts on 2" tenon Arm accepts 2" slipfitter or 2" tenon adapter Ordered with pole PB - 2U - color PB - 3U - color PB - 4U - color EPA - Bracket Size /Max. Size of Luminaire - 1.0 ft` / 7.3 ft 1.6 ft" / 4.7 ft' 2.3 ff (3.4 f) Weight - Bracket Size / Max. Size of Luminaire - 21 lb. / 150 lb. 32 lb. / 150 lb. 44 lb. / 150 lb. 3 Luminaires 4 Luminaires @120° @ 90' / \ 90 1 0 — - ,, — = J Mounts on 2" tenon 120"(TYP, \) '` Arm accepts 2" slipfitter 2' 0" (RAD) 2' 10" / L20URAD) or 2" tenon adapter Catalog Number PB - 3Y - color PB - 4X - color EPA - Bracket Size / Max. Size of Luminaire 1.3 ft' / 4.7 ft' 1.6 ft` / 3 5 ft' Weight - Bracket Size / Max. Size of Luminaire 34 lb. / 150 lb. 44 lb. / 150 lb. Tenon Notes: Pipe Tenon 1:The maximum straight luminaire slipfit length is 4.63" for all Standard 2" Tenon 2 " S chedule 80 factory pp 40 ar m brackets- Consult facto for other tenon applications. y (2.375" O.D.) 2. Total combined weight and EPA of brackets and luminaires cannot exceed that allowed on the poles ordered. 3:Adjacent tenon spacing and fixture dimensions must be Dimensions compared for proper clearance between fixtures. Size 4:Maximum luminaire weight and EPA values are based on a Pole Shaft 100 mph wind speed with a 1.3 gust factor and a maximum O.D. (in) - 2.375 70' mounting height. Length (in) - 5: Material: Center hub is 2 1/2 schedule 40 pipe, arms are Pipe Size - 2.0" Sched 40 2" schedule 40 pipe. 6:Lureinaire EPA and weight is the total of all luminaires to be • mounted on the bracket. 0i 1300 S. Wolf Road • P.O. Box 5065 • Des Plaines, IL 60017 -5065 • Phone (847) 827 -9880 • Fax (847) 827 -2925 .hr,vtivunssGaod„ 220 Chrysler Drive • Brampton, Ontario • Canada L6S 6B6 • Phone (905) 792 -7335 • Fax (905) 792 -0064 o Visit us at www.junolightinggroup.com Printed in U.S.A. ©2006 Juno Lighting, Inc. a SQUARE ,* H7.8.1 AccuLite POLES Project: SQUARE STRAIGHT STEEL F ixture Type: Cat. NO.: Location: - -- - - -- -- -- Series Height Mtg. Color Options Contact /Phone: PRODUCT SPECIFICATIONS Shaft Pole shafts are supplied in 11 gauge or 7 gauge Base Plate Fabricated from structural quality hot thickness having a minimum yield strength of 55,000 psi rolled carbon steel plate conforming to ASTM A36 and conforms to ASTM A595 Grade A • Shafts are of one • Circumferentially welded top and bottom, the base piece construction with a full length longitudinal high fre- plate telescopes the pole shaft • The pole chart quency electric resistance weld • Shafts are uniformly information lists the bolt circle ranges for each pole square in cross section with flat sides, rounded corners Base Cover A full base cover is standard with SSS (0.75" per corner) and no taper Series poles Hand Hole Reinforcing hand hole rim welded into the Anchor Bolts Fabricated from carbon steel bar con - pole shaft • Rectangular shaped tubing or oval shaped forming to AASHTO M314 Grade 55 or ASTM F1554 pipe • Hand holes are furnished with attachment bar, Grade -55 • Bolts have an "L" bend on one end • Bolts cover and screws • Hand holes, located 18" above base are galvanized a minimum of 12" on the threaded end Electrical Ground A nut holder is provided near the • Four anchor bolts are furnished per pole. Each anchor hand hole and includes a 1/2 "- 13 UNC hex head bolt bolt is furnished with two hex nuts and two flat washers and nut PRODUCT CODES Height Fixture Series Nom. Mtg. Color Options -'- Specifications Anchor Gust Gust factor - 1.3 Pole Shaft Pole Base Bolts 80 MPH 90 MPH 100 MPH Base Wall Bolt Circle Diameter Max Max Max Max Max Max O.D. Thickness Weight Dia Square Thickness Length EPA Weight EPA Weight EPA Weight (in) (ga) (Ibs) (in) (in) (in) Hook (in) (ft1 (Ibs) (ft') (Ibs) ( ft') (Ibs) SSS4 - 10 - - DUP 4.0 11 75 8.5 *- 0.5 8.25 0.75 .75 X 17 X 3 30.6 765 23.8 595 189 473 - 12 See Provision 4.0 11 90 8.5 ± 0.5 825 0.75 .75 X 17 X 3 24.4 610 18.8 470 14.8 370 - 14 below for duplex 4.0 11 100 8.5 ± 0.5 8.25 0.75 .75 X 17 X 3 19.9 498 15.1 378 11.7 293 - 16 receptacle 40 11 115 8.5 ± 0.5 825 0.75 .75 X 17 X 3 15.9 398 11.8 295 8.9 223 - 4.0 11 125 8.5 ±0.5 825 0.75 .75X17X3 12.6 315 9.2 230 6.7 168 - 20 Colort 4.0 11 140 8.5 ± 0.5 8.25 0.75 75 X 17 X 3 9.6 240 6.7 167 4.5 150 - 25 - B2 Bronze 40 7 245 8.5 ± 0.5 8.25 0.88 .75 X 17 X 3 9.8 246 69 173 48 120 SSS5 - - White 5.0 11 185 11.0 ±1.0 11.00 100 .75X17 X3 97.7 443 '2.7 343 9.4 235 - 25 - BL Black 5.0 7 360 1 1.0 ± 1.0 11.00 1.00 .75 X 17 X 3 18.1 454 13.3 333 9.5 238 - 30 5.0 7 380 1 1 . 0 ± 1.0 11.00 1.00 .75 X 17 X 3 10.7 267 6.7 167 3.9 100 5556 - 30 60 7 520 12.0 ± 1.0 1250 1.00 1.00 X 36 X 4 19 -0 475 1 3.2 330 9.0 225 - 35 6.0 7 540 12.0 ± 1.0 12.50 1 -00 1.00)1 36 )1 4 12.4 310 7.6 190 4.2 ' - 40 6.0 7 605 12.0 ± 1.0 12.50 1.00 1.00 X 36 X 4 7.2 1 80 3.0 75 - - Drilling Pattern* Tenon Mounting Brackets* - Luminaires Bolt Directly to the Pole: Includes Top Cap Slipfitter Mounted Luminaires: Add suffix to order mounting bracket Alai & Alari+ Quasar Quasar (1000W) with 2" (2 3/8" OD) uminaire tenon (All Lamps) (max. 400W) Aries (All Lamps) Description Bracket Suffix To order pole 1 Luminaire - 1U I drilling add suffix El El 2 Luminaires 1 Luminaire AB -1E3 -1E2 -1E34 EPA 1.0 ft' - 21 lb. in line - 2U 2 Luminaires 3 Luminaires W -2C3 -2C2 2C34 EPA 1.6 ft' - 32 lb. in line - 3U i-' -2L3 -2L2 - 2L34 3 Luminaires EPA 1.3 ft' - 34 lb. @ 120° - 3Y -3T3 -3T2 - 3T34 4 Luminaires 4 Luminaires EPA 1.6 ft' - 44 lb. @ 90° - 4X • -4X3 -4X2 - 4X34 EPA 2.3 ft' - 44 lb. in line - 4U l 1 l ) 1j � J'JNO 1.1,1 GGRour lo ' See following pages for Pole Selection Process and tenon mounting bracket dimensions 0 ar"""E t Designer colors are available - consult factory o* • ELECTRICAL cc 3 z SERVICES Pic EnzEsinumexisEmEs 660 Riverside Drive, P.O. Box 60453, Florence, MA 01062 413 -584 -0737 Fax: 413-587-0737 www.marneyelectric.com October 12, 2010 To: Northampton Building Inspector From: Jeffrey Marney RE: Proposed YMCA sidewalk lighting 4 W(1-01 � LAS ��` ovA sAR X `10v) Pucsf R Ae,k�j pAo"Go met, �C BASIS OF DESIGN 1. The Hampshire Regional YMCA at 286 Prospect Street is an existing building with two stories above grade level and a partial basement which is the lowest level of exit discharge. The existing fire alarm system is addressable and provides partial smoke /heat coverage, sprinkler monitoring, and general audible/visual notification. Reporting is provided via digital communications direct to the Fire Department as well as to a U.L. Listed Central Station. The building is presently classified as Use Group A3 per the 7th Edition 780 CMR pg 49, Sec 303.1 (3). Per pg 236 sec 907.2.1 a fire protective signaling system is required. Per pg 236 sec 907.2.1.1. a voice evacuation system is required. 2. Applicable laws, regulations, and standards. • 7th Edition 780 CMR • 780 CMR 907 Required • NFPA 72 2007 Edition • Northampton Fire Department 2007 guidelines 3. The present system will be brought back on line with repairs including replacement of devices damaged by the recent fire. 4. The following changes, additions, and upgrades will be implemented and completed by January 1, 2010; • Provide additional smoke or heat coverage in the basement, locker room areas, and gym /pool corridors. • Upgrade the fire alarm control panel with voice evacuation. • Change all existing horn /strobes to speaker strobes. • Add speakers and strobes to areas not presently covered. • Add manual pull stations within 5 feet of all exit doors not presently covered • Provide an electronic graphic annunciator panel next to the Fire Alarm Control Panel per Northampton Fire Department requirements. JUL.*: A OFFICIAL f a NOTARY PU8UC t) i3_ %> COMMUN`JJEAUNOFMA My Come Expues Mcs -42011 141 SEQUENCE OF OPERATION '. 1 .J An alarm frorn,La systepn smoke detector, heat detector, sprinkler flow, or manual pull station shall cause the f9.Uowifig to occur; 1. Activate building evacuation speakers with required pre -alert tone followed by a recorded evacuation message. 2. Flash building evacuation strobes with a synchronized flash. 3. Indicate in English language text the device type and location of alarm on the fire alarm control panel and remote annunciator. 4. Indicate by L.E.D.'s on the graphic representation the zoned area and type of device in alarm. 5. Transmit alarm signal to the Fire Department and the U.L. Listed Central Station. Activation of any sprinkler tamper switch shall cause the following to occur; 1. Indicate in English language text the device type and location of device on the fire alarm control panel and remote annunciator. 2. Indicate device type by L.E.D. on the graphic representation. 3. Transmit sprinkler supervisory signal to the Fire Department and U.L. Listed Central Station. Any wiring faults such as opens, shorts, or grounds as well as removal of any peripheral devices shall cause the following to occur; 1. Indicate in English language text the device type and location of fault on the fire alarm control panel and remote annunciator. 2. Transmit trouble signal to the U.L. Listed Central Station for owner /occupant notification. Auxiliary Functions; 1. All alarm conditions will release any magnetically held door hold open devices. 2. Alarm conditions at air handling units will cause that respective unit to shut down. PaA4t. J16-6/4, OFFICIAL SEAL x•' • JIi • A. NASSIF s , YARN' PUBLIC ./ comr,t,A f[tauN OF MASS I S - My Corn. Expires M a r . 2011 r OPERATION: ❑ PNEUMATIC ❑ ELECTRIC 0 HYDRAULIC ■ PIPING SUPERVISED Q YES ❑ NO DETECTING MEDIA SUPERVISED? 0 YES 0 NO et//Q DOES THE VALVE OPERATE FROM THE MANUAL TRIP AND /OR REMOTE CONTROL? ❑ YES ❑ NO DELUGE & IS THERE AN ACCESSIBLE FACILITY IN EACH CIRCUIT FOR TESTING? ❑ YES ❑ NO PREACTION IF NO, EXPLAIN: VALVES I Does each circuit operate Does each circuit Maximum time to MAKE MODEL I supervision loss alarm? operate valve release? operate release I YES NO YES NO MIN. SEC. t HYDROSTATIC: Hydrostatic tests shall be made at not less than 200 psi (13.6 bars) for two hours or 50 psi (3.4 bars) above static pressure in excess of 150 psi (10.3 bars) for two hours. Differential dry-pipe valve clappers shall be left open during test to prevent TEST . damage. All aboveground piping leakage shall be stopped. DESCRIPTION PNEUMATIC: Establish 40 psi (2.7 bars) air pressure and measure drop which shall not exceed 1 -1/2 psi (0.1 bars) in 24 hours. Test • pressure tanks at normal water level and air pressure and measure air pressure drop which shall not exceed 1 -1/2 psi (0.1 bars) in 24 hours. ALL PIPING HYDROSTATICALLY TESTED AT 2 00 PSI FOR d., Hrs. IF NO, STATE REASON DRY PIPING PNEUMATICALLY TESTED? ❑ YES • '1 O l./b DM PIPE EQUIPMENT OPERATES PROPERLY? EYES 0 N DRAIN READING OF GAGE LOCATED NEAR WATER SUPPLY TEST PIPE: RESIDUAL PRESSURE 7? VALVE IN TEST PIPE TESTS TEST � p PSI OPEN WIDE / ? PSI Underground mains and lead -in connections to system risers shall be flushed before connection made to sprinkler piping. VERIFIED BY COPY OF THE FORM NUMBER 858? ❑ YES U NO OTHER EXPLAIN OVA eXISfNb LMrntQbrofJUD FLUSHED BY INSTALLER OF UNDERGROUND SPRINKLER PIPING? ❑ YES ❑ NO BLANK NUMBER USED LOCATIONS NUMBER REMOVED TESTING GASKETS I WELDED PIPING? ❑ YES O IF YES /V'A DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING PROCEDURES COMPLY WITH THE REQUIREMENTS OF AT LEAST AWS D10.9, LEVEL AR -3? ❑ YES ❑ NO WELDING DO YOU CERTIFY THAT THE WELDING WAS PERFORMED BY WELDERS QUALIFIED IN COMPLIANCE WITH THE REQUIREMENTS OF AT LEAST AWS D10.9, LEVEL AR -3? ❑ YES ❑ NO DO YOU CERTIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A DOCUMENTED QUALITY CONTROL PROCEDURE TO INSURE THAT ALL DISCS ARE RETRIEVED, THAT OPENINGS IN PIPING ARE SMOOTH, THAT SLAG AND OTHER WELDING RESIDUE ARE REMOVED, AND THAT INTERNAL ^ • DIAMETERS OF PIPING ARE NOT PENETRATED? ❑ YES ❑ NO HYDRAULIC NAMEPLATE PROVIDED? [F'S'ES ❑ NO DATA IF NO EXPLAIN: NAMEPLATE . DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN: . 9-IS . REMARKS NAME OF INSTALLING CONTRACTOR /'1.J • Ail = 0 • tiocN• L6j rn ACTDns TESTS WITNESSED BY SIGNATURES FOR / P • OWN Signe ) TITLE DATE G I / , r / FO` IN LING CONTRAC 0 (Signed) TITLE DATE • L )71,f,a L /�i�,d; I ��! Nto 7 P. 1 9 -1s•67 ADDITIONAL EXPLANATION AND NOTES: M. J. MORAN, INC. Mechanical Contractor 4 South Main Street Haydenville, MA 01039 1 CK 1 CONTRACTOR'S MATERIAL & TEST CERTIFICATE FOR ABOVEGROUND PIPING PROCEDURE: Upon completion of work, inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners and contractor. It is understood the owner's representatives signature in no way prejudices any claim against the contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. PROPERTY NAME DATE NIV/PSN/nc RF_G /D,vf7G Y,/104.A 7- /s PROPERTY ADDRESS 2840 IliosPee r SrntET, NonrNAnProiJ, nn DIObo ACCEPTED BY APPROVING AUTHORITY'IS) NAMES L U ci[ I vr//on l r/ LS ADDRESS PLANS INSTALLATION CONFORMS TO ACCEPTED PLANS [r YES ❑ NO EQUIPMENT USED IS APPROVED (IF NO, STATE DEVIATIONS BELOW) [vrYES ❑ NO HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCATION OF CONTROL "YES ❑ NO VALVES AND THE CARE AND MAINTENANCE OF THIS NEW EQUIPMENT? IF NO, EXPLAIN: INSTRUCTIONS ' HAVE COPIES OF APPROPRIATE INSTRUCTIONS AND CARE AND MAINTENANCE CHARTS BEEN [] YES ❑ NO LEFT ON PREMISES? IF NO, EXPLAIN: LOCATION OF SUPPLIES BUILDINGS SYSTEM CMS /' /L bDr ELi./2 E 3 SES 4,'o BAS,E/1 E,v r� LESS 44E/0 An o�ND Pool MAKE MODEL I YEAR OF TEMPERATURE I Ilj MANUFACTURE ORIFICE SIZE QUANTITY RATING Viebv[.- 1/ 3 mmiir tiocl7DF, 3r i d o09 K=1". S. G. 3 8 a S/ ° SPRINKLERS of a it I 'r „ yB /SS ° Vi ISI Alb- &m. o. it I I' I I i0 / / SS ° k'Ki/J6- tfoucotaEO r1onA i /, t ? if /G,S 41w S. w. DIN SnrwAz.I ,, Kt //. 2. / Loo ° _ PIPE CONFORMS TO /VFP• /3 STANDARD ❑'�rES ❑ NO PIPE AND FITTINGS CONFORM TO A/Fp/ /3 STANDARD QS 0 NO FITTINGS IF NO, EXPLAIN: ALARM ALARM DEVICE MAXIMUM TIME TO OPERATE THROUGH TEST PIPE VALVE OR TYPE MAKE MODEL MIN, ,' , SEC. FLOW ✓19it1g FLOfJ 16 1tE2 ✓S 2 - fr O 38 INDICATOR DRY VALVE a.O:D MAKE MODEL SERIAL NUMBER MAKE MODEL SERIAL NUMBER R 1 TIME TO TRIP WATER AIR ;: TRIP POINT AIR Time' Water ': Alarm Operated eached,Teet DRY PIPE THRU TEST PIPE PRESSURE PRESSURE PRESSURE Properly Outlet OPERATING MIN. SEC. PSI PSI PSI MIN. SEC. MIN. SEC. TEST WITHOUT Q.O.D. WITH Q.O.D. I 1 IF NO, EXPLAIN: .007,1 : 4A M.J. MORAN, INC. LETTER OF TRANSMITTAL FIRE PROTECTION DIVISION 4 SOUTH MAIN STREET TELEPHONE: FAX: r a vy HAYDENVILLE, MA 01039 (413)268 -7251 (413)268 -9375 c TO: Northampton Building Department DATE: 9 -17 -09 I JOB NUMBER: 09 -824 212 Main Street ATTENTION: Mr. Ton y Patillo ` Room 100, Building Dept. RE: Fire Sprinklers at: Northampton, MA 01060 YMCA Attn: Building Commissioner WE ARE SENDING YOU ® ATTACHED ❑UNDER SEPARATE COVER VIA THE FOLLOWING ITEMS: ❑ SHOP DRAWINGS ❑PRINTS ['PLANS ❑SAMPLES ['SPECIFICATIONS ❑COPY OF LETTER ❑CHANGE ORDER ❑ COPIES DATE NUMBER DESCRIPTION One 9 -15 -09 Copy Contractors material and test certificate for above ground piping. THESE ARE TRANSMITTED AS CHECKED BELOW: ❑ For approval ❑Approved as submitted ❑Resubmit copies for approval ❑For your use ❑Approved as noted ❑Submit copies for distribution ❑ As requested ❑Returned for corrections ❑Return corrected prints ['For review and comment ❑ ❑FOR BIDS DUE: , 2002 ❑PRINTS RETURNED AFTER LOAN TO US REMARKS: Copies have been sent to: Fire Department Owner Owner's insurer Please call with any questions. COPY TO: Job File ,p SIGNED: 6nAtutIG �istic 1 Date: 9 - / 7'0