Loading...
38B-006 (7) May 11, 2009 M.J. Moran Plumbing & heating Attn:Monica 4 South Main Street P.O. Box 278 Haydenville, MA 01039 Re: Operations and Maintenance for: Smith College — Scott Gym — Office HVAC Renovation YTI# 08 -L -1028 To Whom It May Concern: Enclosed please find three (3) complete sets of 0 & M's without asbuilts with pertinent data for the above referenced project. Asbuilts will follow at a later date. If you have any questions, please call. Very truly yours, Brenda L. Gelinas Enclosure Cc: umasslowell- foxhallrenovations 280 ftioody Street, 1 er/lote, MA 0/056 1 412.54 .65 )5 12 4(3.5476657 Automatic tt mpt tature o tro0 ood energ rnmrageotent getern . Final Report of Structural Tests and Inspections For compliance with the 6th Edition of the Massachusetts State Building Code Project: Boiler Plant Renovation Location: Smith College Owner: Smith College Owner's Address: Smith College North Hampton, MA 01063 Architect of Record: Bohlin Cywinski Jackson Structural Engineer of Record: Gibble Norden Champion Brown Consulting Engineers, Inc. To the best of my information, knowledge and belief, the structural tests and inspections itemized in the Program of Structural Tests and Inspections submitted for permit have been satisfactorily completed and all discovered defects have been corrected. Comments: The Program of Structural Tests and Inspections does not relieve the Contractor or its subcontractors of their responsibilities and obligations for quality control of the work, for any design work which is included in their scope of services, and for full compliance with the requirements of the Construction Documents. Furthermore, the detection of, or the failure to detect, deficiencies or defects in the work during testing and inspection conducted pursuant to the Program does not relieve the Contractor or its subcontractors of their responsibility to correct all deficiencies or defects, whether detected or undetected, in all parts of the work, and to otherwise comply with all requirements of the Construction Documents. Respectfully Submitted, % 4E E,011 OF .41 4s _ Structural Engineer of Record 4 4 o JAMES F cy `s� NORDEN N Jamps Norden, P E -- S TRUCTURAL / No. 36558 Type cif print name -$) A FQISTE AE G ; i ss / 6 k Al E t / 9+� f iG1�EE w j / " Yom Si natur ` � w � � !y -Date i 7V Registration Seal GNCB 1• Glbble Norden Chanapior Bro:'n Consulting Engineers. Inc. Structural Engineering Geotechnical Engineering February 26, 2009 Historic Preservation Anthony L. Patillo, CBO 212 Main Street - Rm 100 Northampton, MA 01060 -3189 Re: Boiler Plant Renovation Smith College Northampton, MA Principals Kenneth Gibble. PE. Dear Mr. Patillo: James F. Norden. PE. Laura E Chaq,rpio.1 FE This letter is to state that Gibble Norden Champion Brown Consulting C arles C. Bru,Il PE . Engineers, Inc. has performed the necessary professional services during Geotechnical Associate construction in regards to the structural work associated with the above Da Freed PE project, and that to the best of my knowledge, information, and belief the structural work has been done in conformance with the permit and plans approved by the Building Department and with the provisions of the Massachusetts State Building Code and other pertinent laws and ordinances. Very truly yours, //i / c .> James F. Norden Mass. Registration No. 36558 cc: Dave Chiovoloni, VZHS Engineers dchiovoloni@vanzelm.com 130 Elm Street PO. Box 802 Old Saybrook. CT 06475 Tel 860.388.1224 Fax 860.388.4613 lastnameCg ncbengineers.com gncbengineers.com so n Peter Q. Bohlin, FAIA Bernard J. Cywinski, FAIA Jon C. Jackson, FAIA W. Dan Haden 111, AIA Frank W. Grauman, AIA William D Loose, AIA Cornelius J. Reid 111, AIA Karl A. Backus, AIA Gregory R. Mottola, AIA C. Roxanne Sherbeck, AIA Robert Miller, AIA July 8, 2009 Mr. Anthony L. Patillo, CBO City of Northampton 212 Main Street - Rm 100 Northampton, MA 01060 -3189 Re: Co -Gen Facility Smith College Northampton, MA Dear Mr. Patillo: This letter is to state that Bohlin Cywinski Jackson has performed the necessary professional services during construction in regards to the architectural work associated with the above project, and that to the best of my knowledge, information, and belief the architectural work has been done in conformance with the permit and plans approved by the Building Department and with the provisions of the Massachusetts State Building Code and other pertinent laws and ordinances. Very truly yours, \ Wm s i/4/44 0 ,........ 4 1 Jon C. Jackson, FAIA Massachusetts Registration No. 30157 cc: Dave Chiovoloni, VZHS Engineers Architecture Pianning intehoi Design 307 Rehth Avenue, e, S ite 'i30 i i +..r-B rr ;fp p ..,iungh Phiia. ieip'shi siSeeni r a Francisco Pinsburicin. Pdrinsyly i a 15222-2 123 4,12 x 7'3 „ ,iii *'€ :3x 41 2-769-2209 2fJ09 E N G I N E E R S July 15, 2009 Mr. Anthony L. Patillo, CBO City of Northampton, MA — Office of the Building Commissioner 212 Main Street — Room 100 Northampton, MA 01060 -3189 Re: Smith College Boiler Plant Renovation (Cogeneration) Final Report — Satisfactory Completion van Zelm Project 2005116.00 Dear Mr. Patillo: van Zelm Heywood & Shadford, Inc., Mechanical and Electrical Engineers, has performed the necessary professional services during construction of the Smith College Boiler Plant Renovation (Cogeneration) Project. To the best of my knowledge, information, and belief the mechanical, electrical, and fire protection work has been completed in conformance with the construction documents and permit approved by the Office of the Building Commissioner and with the provisions of the Massachusetts State Building Code and other pertinent laws and ordinances. Very truly yours, VAN ZELM HEYWOOD & SHADFORD, INC. .1 Joseph F. Camean, P.E. Vice President Massachusetts Registration No. 36989 • Attachments: Architect's Final Report - Bohlin Cywinski Jackson (1 page) Structural Engineer's Final Report - Gibble Norden Champion Brown (2 pages) cc: Mr. Gary J. Hartwell, Smith College van Zelm Project File U:\200512005116.00 \Letters \090715 Letter to Anthony L Patillo (Final Report to Northampton Building Commissioner).doc V'.AA 71 1\1 11.,Vwool) & 711. )it D. 1AC. 10 TALCOTT NOTCH FARMINGTON CT 06032 -1800 P• (860)284 -5064 F (860)284 -5098 'va nzelm e an 126 WEST ST BP- 2007 -0782 GIs #: COMMONWEALTH OF MASSACHUSETTS Map:Block: 38B - 006 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: Non structural interior renovations BUILDING PERMIT Permit # BP- 2007 -0782 Project # JS- 2007- 000203 Est. Cost: $8404301.00 Fee: $42021.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: VANZELM HEYWOOD & SHADFORD INC36989 Lot Size(sq. ft.): 9365.40 Owner: Smith College Zoning: SI Applicant: THE PIKE CO AT: 126 WEST ST Applicant Address: Phone: Insurance: 2 PENN PLAZA SUITE 1500 (212) 292 - 5135 NEW YORKNY10121 ISSUED ON:3/15/2007 0:00:00 TO PERFORM THE FOLLOWING WORK:INSTALL GAS TURBINE /HRSG & MISC EQUIP IN EXISTING STRUCTURE (COGEN) POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Driveway Final: Final: / f 'I Q (� Final: / / / / //d� �� "" Rough Frame: Gas: Fire Department Fireplace /Chimney: Rough: Oil: Insulation: Final:y i 10.--(21.3 4 - Final: THIS PERMIT MAY BE REVOKED BY TIICITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGUL IONS . Certificate of Occu•anc' Aa" Signature: s "' FeeType: - Date aid: Amount: Building 3/15/2007 0:00:00 $42021.00643582 212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272 Building Commissioner - Anthony Patillo