16A-001 (2) Gougeon 11 -10 -11 eye Leeds Ma 4:27pm 1 of 1 KeyBeam® 4.507f kmBeamEngine 4.509s Materials Database 1307 Member Data Description: Member Type: Beam Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: None Standard Load: Moisture Condition: Dry Building Code: IBC / IRC Dead Load: 10 PLF Deflection Criteria: L/360 live, L/240 total Live Load: 40 PLF Deck Connection: Nailed Member Weight: 11.7 PLF Filename: KYB1 Other Loads Type Trib. Dead Other (Description) Side Begin End Width Start End Start End Category Replacement Uniform (PSF) Top 0' 0.00" 18' 4.00" 12' 7.00" 10 0 Live Additional Uniform (PLF) Top 0' 0.00" 18' 4.00" 0 136 Live +;C 3 �5 .- r i 1 , f B i �r Vg 4� L y s ��' n- re ,� v z, �*� 4 ^ � s r� h��! � t ; x'� 14 y f K a�.; T ` . ., e a ` 4 a s ,,, 1, }: 0 ' . , 3 t -, n . $6 s {4 v � �� r • i IT 41' 18 4 O P 18 4 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall Spruce- Pine -Fir 3.500" 1.645" 2448# -- 2 17' 10.750" Wall Spruce- Pine -Fir 3.500" 1.645" 2448# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Dead Live 1 1231# 1217# 2 1231# 1217# Design spans 17 10.750" Product: 1- 314x11 -718 VERSA -LAM 2.0 3100 SP 2 ply Component Member Design has Passed Design Checks.** Design assumes continuous lateral bracing along the top chord. Design assumes no lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 10950.'# 21275.'# 51% 8.95' Total load D +L Shear 2177.# 7897.# 27% 0.01' Total load D +L Max. Reaction 2448.# 5206.# 47% 0' Total load D +L TL Deflection 0.6462" 0.8948" L/332 8.95' Total load D +L LL Deflection 0.3213" 0.5965" U668 8.95' Total load L Control: TL Deflection DOLs: Live =100% Snow=115% Roof =125% Wind =160% Manufacturers installation guide MUST be consulted for multi -ply connection details and altematives All product names are trademarks of their respective owners - a s a : - . =Copyright (C)1987 -2011 by Keymark Enterprises, LLC. ALL RIGHTS RESERVED. t t:It PILISr.I LL "Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer's specifications.