Loading...
37-092 Job ; Truss I Truss Type Qty Ply I NEFH / POWERS 08030 T6GE 1ROOFTRUSS 1 1 I I I _ _ _ ; Job Reference (optional) - - n ---- - - i -- -- Truss Engineering Indian Corp., Indian n Orchard, MA 01151 5.200 s Dec 2 2003 MiTek Industries, Inc. Mon Apr 1211:12:24 2004 Page 1 ' -1 -0-0 1 6-6-0 � 13 -0-0 14 -0-0 � 1 -0-0 6-6-0 6-6-0 1 -0-0 3x4 = Scale = 1:31.1' • 5 Kg 4 10.00 12 1 6 7 3 2 1Ii iii,A 9 . ...................... ....................... ................. 0 ;:... . ∎•• ∎∎• ....... ........ AVO ANNA ........................ ANW . . ................................................. N . ..... .. ... ............... : : . : : : : : : . : . : . : . : . : . . 11 ,4 0 : . : . : . : . : . : . : . : . . 0 . 11 : . : . : . : . : 11 . 11 ... ,. : . : . : . : . ::: . :: . :. : : : : : : : 1 : 4,11 : 3x6 11 3x6 11 13 -0-0 , 13 -0-0 H Plate Offsets (X Y) 110:0- 2- 5,0 -1 -81 [16:0 -3- 12,0 -1 -8] _. i LOADING (psf) SPACING 2 -0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.24 ! Vert(LL) n/a - n/a 999 MI120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.12 Vert(TL) 0.01 1 >999 180 BCLL 0.0 * Rep Stress Inc: NO WB 0.10 Horz(TL) 0.00 10 n/a n/a BCDL 10.0 Code IRC2000/TPI2002 (Matrix) Weight: 58 Ib LUMBER - TOP CHORD 2 X 4 SPF No.2 Max Uplift WEBS BOT CHORD 2 X 4 SPF No.2 14 = - 116(load case 4) 4-14 = - 173/143 3-15 = - 177/187 6-12 = - 173/142 WEBS 2 X 4 SPF Stud 15 = - 191(load case 4) 7 -11 = - 177/185 OTHERS 2 X 4 SPF Stud 12 = - 116(load case 5) 11 = - 183(load case 5) NOTES (12) BRACING Max Gray 1) Unbalanced roof live loads have been considered for this design. TOP CHORD 16 = 243(load case 1) 2) Wind: ASCE 7 -98; 100mph; h =25ft; TCDL= 4.2psf; BCDL= 5.Opsf; Category 11; Exp C; Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. 10 = 243(Ioad case 1) enclosed; MWFRS gable end zone; cantilever left and right exposed ; end vertical left BOT CHORD 13 = 181(load case 1) and right exposed; Lumber DOL =1.33 plate grip DOL =1.33. Rigid ceiling directly applied or 10-0 -0 oc bracing. 14 = 212(Ioad case 6) 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to 15 = 218(Ioad case 6) wind (normal to the face), see MiTek "Standard Gable End Detail" REACTIONS (lb /size) 12 = 212(load case 7) 4) As requested, plates have not been designed to provide for placement tolerances or 16 = 243/13 -0-0 11 = 218(load case 7) rough handling and erection conditions. It is the responsibility of the fabricator to increase; 10 = 243/13 -0-0 plate sizes to account for these factors. 13 = 181/13 -0-0 FORCES (lb) - Maximum Compression /Maximum Tension 5) All plates are 1.5x4 MI120 unless otherwise indicated. 14 = 205/13 -0-0 TOP CHORD 6) This truss requires plate inspection per the Tooth Count Method when this truss is 15 = 218/13 -0-0 2 -16 = - 218/91 1 -2 = 0/62 2 -3 = - 159/136 chosen for quality assurance inspection. 12 = 205/13 -0-0 3-4 = - 77/141 4-5 = - 75/192 5-6 = - 75/172 7) Gable requires continuous bottom chord bearing. 11 = 218/13 -0-0 6-7 = - 77/110 7 -8 = -112/89 8-9 = 0/62 8) Truss to be fully sheathed from one face or securely braced against lateral movement Max Horz 8-10 = - 218/79 (i.e. diagonal web). 16 = - 238(load case 2) BOT CHORD 9) Gable studs spaced at 2 -0-0 oc. Max Uplift 15-16 = - 54/180 14-15 = - 54/180 13-14 = - 54/180 10) *This truss has been designed for a live load of 20.0psf on the bottom chord in all 16 = - 98(load case 2) 12 -13 = - 54/180 11 -12 = - 54/180 10-11 = - 54/180 areas where a rectangle 3-6-0 tall by 1 -0-0 wide will fit between the bottom chord and any 10 = - 61(load case 3) WEBS other members. Continued on page 2 5-13 = -151/0 Job Truss Truss Type - - Qty 1 PIy 1 NEFH / POWERS 08030 T5 ROOF TRUSS 7 1 1 1 I Job Reference optional) _ Truss Engineering Corp., Indian Orchard, MA 01151 5.200 s Dec 2 2003 MiTek Industries, Inc. Mon Apr 12 11:12:23 2004 Page 1 3 -1-4 6 -6-3 10 -1 -12 13-9-5 17 -2-4 1 20 -0-0 � 3 -1-4 3 -4-15 3 -7 -9 3 -7 -9 3 -4-15 2 -9 -12 4x5 I I Scale: 1/4 "1 4 II 1.5x4 I1 1.5x4 11 10.00112 5 • i i 4x4.2 4x4 Q 2 8 3x4 I I 3x4 1 I 11 10 12 13 9 8 4x5 = 4x9 = 4x9 = 3x5 = 1 6-6-3 1 13 -9-5 1 19 -10-8 20 6-6-3 7 -3 -2 6 -1 -3 0 -1-8 • LOADING (psf) SPACING 2 -0-0 CSI DEFL in (loc) l/defl Lid PLATES GRIP TCLL 70.0 Plates Increase 1.15 TC 0.35 Vert(LL) -0.20 9-10 >999 240 M1120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.66 Vert(TL) - 0.29 9-10 >807 180 - BCLL 0.0 1 Rep Stress Ina YES 1 WB 0.73 I Horz(TL) 0.04 8 n/a n/a BCDL 10.0 Code IRC2000/TPI2002 1 (Matrix) 1 Weight: 110 Ib LUMBER 7) Bearing at joint(s) 11 considers parallel to grain value using ANSI/TPI 1 -1995 angle to TOP CHORD 2 X 4 SPF No.2 TOP CHORD grain formula. Building designer should verify capacity of bearing surface. BOT CHORD 2 X 4 SPF No.2 5-6 = - 1808/293 6-7 = - 264/88 1 -11 = - 417/125 8) Provide mechanical connection (by others) of truss to bearing plate capable of WEBS 2 X 4 SPF Stud *Except* 7 -8 = - 278/94 withstanding 223 Ib uplift at joint 11 and 219 Ib uplift at joint 8. W5 2 X 4 SPF No.2, W5 2 X 4 SPF No.2, W1 2 X 4 SPF No.2 BOT CHORD 9) All Plates 20 Gauge Unless Noted W7 2 X 4 SPF No.2 10-11 = - 308/1365 10-12 = - 122/979 12 -13 = - 122/979 9-13 = - 122/979 8-9 = - 116/1199 BRACING WEBS TOP CHORD 4-10 = - 357/978 3-10 = - 582/286 2 -10 = - 146/173 Structural wood sheathing directly applied or 4-0-11 oc purlins, except end verticals. 4-9 = - 342/885 5-9 = - 586/288 6-9 = - 45/172 BOT CHORD 2 -11 = - 1741/222 6-8 = - 1825/228 Rigid ceiling directly applied or 10-0 -0 oc bracing. NOTES (9) REACTIONS (Ib /size) 1) Unbalanced roof live loads have been considered for this design. 11 = 1780/0 -3-8 2) Wind: ASCE 7 -98; 100mph; h =25ft; TCDL= 4.2psf; BCDL= 5.Opsf; Category 11; Exp C; 8 = 1784 /Mechanical enclosed; MWFRS gable end zone; cantilever left and right exposed ; end vertical left i Max Horz and right exposed; Lumber DOL =1.33 plate grip DOL =1.33. I 11 = 381(load case 3) 3) As requested, plates have not been designed to provide for placement tolerances or Max Uplift rough handling and erection conditions. It is the responsibility of the fabricator to increase 11 = - 223(load case 4) plate sizes to account for these factors. 8 = - 219(load case 5) 4) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection. FORCES (Ib) - Maximum Compression /Maximum Tension 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all TOP CHORD areas where a rectangle 3-6-0 tall by 1 -0-0 wide will fit between the bottom chord and any 1 -2 = - 438/117 2 -3 = - 1866/299 3-4 = - 1868/483 other members. 4-5 = - 1812/475 6) Refer to girder(s) for truss to truss connections. Job Truss Truss Type Qty Ply NEFH / POWERS 08030 1T4GE ROOF TRUSS 1 1 Job Reference (optional) Truss Engineering Corp., Indian Orchard, MA 01151 5.200 s Dec 2 2003 MiTek Industries, Inc. Mon Apr 1211:12:22 2004 Page 2 NOTES (13) 2) Wind: ASCE 7 -98; 100mph; h =25ft; TCDL= 4.2psf; BCDL= 5.Opsf; Category 11; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL =1.33 plate grip DOL =1.33. 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable End Detail" 4) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 5) All plates are 1.5x4 MI120 unless otherwise indicated. 6) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection. 7) Gable requires continuous bottom chord bearing. 8) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 9) Gable studs spaced at 2 -0-0 oc. 10) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1 -0-0 wide will fit between the bottom chord and any other members. 11) Bearing at joint(s) 22, 12 considers parallel to grain value using ANSI/TPI 1 -1995 angle to grain formula. Building designer should verify capacity of bearing surface. 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 205 Ib uplift at joint 22, 149 Ib uplift at joint 12, 112 Ib uplift at joint 18, 156 Ib uplift at joint 19, 100 Ib uplift at joint 20, 277 Ib uplift at joint 21, 111 Ib uplift at joint 16, 155 Ib uplift at joint 15, 104 Ib uplift at joint 14 and 263 Ib uplift at joint 13. 13) All Plates 20 Gauge Unless Noted Job Truss I Truss Type Qty Ply NEFH / POWERS 08030 T4GE �ROOFTRUSS 1 1 I I - 1 Job Reference (optional) Truss Engineering Corp., Indian Orchard, MA 01151 5.200 s Dec 2 2003 MiTek Industries, Inc. Mon Apr 12 11:12:22 2004 Page 1 10 -1 -12 I 20 -3-8 10 -1 -12 10 -1 -12 1 3x4 = Scale; 1/4" =11 6 5 7 i i 10.00 1 4 ST5 8 . , 3 i 11119 2 1 2x4 II 2x411 11 1 ' • !:!:!:!:!:! :! :! :! :lQ:l:l:iSSl:iSIO_:SIO.:I:IQQ:!i :!x!xzz i !:l :il :l:l:lHl:l:l:l:l:l:l:l:l:l:l:!:! O_ QQQQ:I:I:l :l :l O_ :i! :! :! :! *:! :!:!Q:!:!:!:!:!:!:!:!:!:!:!:!:! 22 21 20 19 18 17 16 15 14 13 12 3x4 = 3x4 = 20 -3-8 . 20-3 -8 Plate Offsets (X,Y) [7 -0-0 0- 0- 0];18 :0 -0- 0,0-0-0], [9:0- 0- 0,0 -0-0], [10:0 -0-0,0 -0-0], 113_0- 0- 0,0 -0-0], [14:0- 0- 0,0 -0-0], [15:0- 0- 0,0 -0-0] [16:0-0-0,0-0-0] _ ____ _ LOADING (psf) SPACING 2 -0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP . TCLL 70.0 Plates Increase 1.15 TC 0.24 Vert(LL) n/a - n/a 999 MI120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.24 Vert(TL) n/a - n/a 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.38 Horz(TL) 0.01 12 n/a n/a BCDL 10.0 Code IRC2000/TPI2002 (Matrix) Weight: 110 Ib LUMBER TOP CHORD 2 X 4 SPF No.2 14 = 386/20-3 -8 Max Grav BOT CHORD 2 X 4 SPF No.2 13 = 349/20-3 -8 15 = 436(load case 1) WEBS 2 X 4 SPF No.2 Max Horz 14 = 386(load case 1) OTHERS 2 X 4 SPF Stud `Except* 22 = - 374(load case 2) 13 = 366(load case 7) ST5 2 X 4 SPF No.2 Max Uplift 22 = - 205(load case 2) FORCES (Ib) - Maximum Compression /Maximum Tension BRACING 12 = - 149(load case 3) TOP CHORD TOP CHORD 18 = - 112(load case 4) 1 -2 = - 277/233 2 -3 = - 171/188 3-4 = - 170/225 Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. 19 = - 156(load case 4) 4-5 = - 172/294 5-6 = - 167/338 6-7 = - 167/318 BOT CHORD 20 = - 100(load case 4) 7 -8 = - 172/268 8-9 = - 170/199 9-10 = - 171/137 Rigid ceiling directly applied or 10-0-0 oc bracing. 21 = - 277(load case 4) 10-11 = - 218/174 1 -22 = - 192/159 11 -12 = - 192/115 WEBS 16 = - 111(load case 5) BOT CHORD 1 Row at midpt 6-17 15 = - 155(load case 5) 21 -22 = - 138/195 20-21 = - 138/195 19-20 = - 138/195 14 = - 104(load case 5) 18-19 = - 138/195 17 -18 = - 138/195 16-17 = - 138/195 REACTIONS (Ib /size) 13 = - 263(load case 5) 15-16 = - 138/195 14-15 = - 138/195 13-14 = - 138/195 22 = 216/20-3 -8 Max Gray 12 -13 = - 138/195 12 = 216/20-3 -8 22 = 266(load case 3) WEBS 17 = 346/20-3 -8 12 = 216(load case 1) 6-17 = - 325/0 5-18 = - 318/134 4-19 = - 311/170 18 = 420/20-3 -8 17 = 346(load case 1) 3-20 = - 305/140 2 -21 = - 324/223 7 -16 = - 318/132 19 = 436/20-3 -8 18 = 437(load case 6) 8-15 = - 311/171 9-14 = - 305/142 10-13 = - 324/217 1 20 = 386/20-3 -8 19 = 436(load case 1) 21 = 349/20-3 -8 20 = 386(loadcase 1) NOTES (13) i 16 = 420/20-3 -8 21 = 366(load case 6) 1) Unbalanced roof live loads have been considered for this design. ' 15 = 436/20-3 -8 16 = 437(load case 7) Continued on page 2 Job Truss Truss Type City Ply NEFH / POWERS ' 08030 T4 ROOF TRUSS 3 1 Job Reference (optionally Truss Engineering Corp., Indian Orchard, MA 01151 5.200 s Dec 2 2003 MiTek Industries, Inc. Mon Apr 1211:12:21 2004 Page 1 3 -1-4 6-6-3 10 -1 -12 13 -9-5 17 -2-4 , 20 -3-8 3 -1-4 3 -4-15 3 -7 -9 3 -7 -9 3 -4-15 3 -1-4 4x5 I I Scale: 1/4 " =1i 1 4 1 E: 10.00 12 1.5x4 I1 1.5x4 5 I1 3 i i • 4x4 -',/ • 4x4 2 6 • 3x411 3x411 Aiiiii 7 . 5/ . - 11 10 12 13 9 8 4x5 = 4x9 = 4x9 = 4x5 = 1 6-6-3 13 -9-6 1 20-3 -8 6-6-3 7 -3-2 6-6-3 LOADING (psf) SPACING 2 -0-0 CSI DEFL in (loc) Udell Lid PLATES GRIP TCLL 70.0 Plates Increase 1.15 TC 0.36 Vert(TL) - 0.21 9-10 >999 240 M1120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.67 Vert(TL) - 0.30 9-10 >799 180 - BCLL 0.0 - Rep Stress Incr YES WB 0.75 Horz(TL) 0.04 8 n/a n/a BCDL 10.0 Code IRC2000/TPI2002 1 (Matrix) Weight: 110 Ib LUMBER 7) Provide mechanical connection (by others) of truss to bearing plate capable of TOP CHORD 2 X 4 SPF No.2 TOP CHORD withstanding 228 Ib uplift at joint 11 and 228 Ib uplift at joint 8. BOT CHORD 2 X 4 SPF No.2 5-6 = - 1916/305 6-7 = - 443/117 1 -11 = - 421/125 8) All Plates 20 Gauge Unless Noted , WEBS 2 X 4 SPF Stud *Except* 7 -8 = - 421/125 W5 2 X 4 SPF No.2, W5 2 X 4 SPF No.2, W1 2 X 4 SPF No.2 BOT CHORD W1 2 X 4 SPF No.2 10-11 = - 303/1398 10-12 = - 114/1020 12 -13 = - 114/1020 9-13 = - 114/1020 8-9 = - 140/1398 BRACING WEBS TOP CHORD 4-10 = - 356/975 3-10 = - 582/286 2 -10 = - 143/172 Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. 4-9 = - 356/975 5-9 = - 582/285 6-9 = - 143/173 BOT CHORD 2 -11 = - 1787/229 6-8 = - 1787/228 Rigid ceiling directly applied or 10-0 -0 oc bracing. NOTES (8) REACTIONS (Ib /size) 1) Unbalanced roof live loads have been considered for this design. 11 = 1818/0-3-8 2) Wind: ASCE 7 -98; 100mph; h =25ft; TCDL= 4.2psf; BCDL= 5.Opsf; Category II; Exp C; 8 = 1818/0 -3-8 enclosed; MWFRS gable end zone; cantilever left and right exposed ; end vertical left Max Horz and right exposed; Lumber DOL =1.33 plate grip DOL =1.33. 11 = - 374(load case 2) 3) As requested, plates have not been designed to provide for placement tolerances or Max Uplift rough handling and erection conditions. It is the responsibility of the fabricator to increase ' 11 = - 228(load case 4) plate sizes to account for these factors. 8 = - 228(load case 5) 4) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection. FORCES (Ib) - Maximum Compression/Maximum Tension 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all TOP CHORD areas where a rectangle 3-6-0 tall by 1 -0-0 wide will fit between the bottom chord and any 1 -2 = - 443/117 2 -3 = - 1916/306 3-4 = - 1919/489 other members. 4-5 = - 1919/489 6) Bearing atjoint(s) 11, 8 considers parallel to grain value using ANSI/TPI 1 -1995 angle to grain formula. Building designer should verify capacity of bearing surface. Job Truss Truss Type Oty [ Ply NEFH / POWERS 08030 T3GE ROOF TRUSS !1 1 1 ■ ___ ! Job Reference (optional) Truss Engineering Corp., Indian Orchard, MA 01151 5.200 s Dec 2 2003 MiTek Industries, Inc. Mon Apr 1211:12:20 2004 Page 1 � -1 -0-0 � 7 -0-0 , 14 -0-0 1 -0-0 7 -0-0 7 -0-0 3x4 = Scale = 1:20.4 5 /1 6 4 6.00 12 1 7 , 1 3 1 a —.41411111111 III C 2 : C 4 : C \ I o I I I l 1 '1' '1'1'1'1'1'1'1'1'1'1'1'1'11''1' 1'1'1'1'1'1'1'1'1'1'11 ''1'1'11 '' 1' 1' 1'11111111 ''''''' 1' 1'1' ,- ;ct -1'1'1'1'1'1'1'1'1'''1'1 '1'1'1'1'1'1'1'1'1'1'.1.1.1.1. 1.1.1.1.1.1.1.1.1.1.1.1.1.1.1.1 .1.1. ,- 9 ,1.1.1.1.1.1.1.1.1.1. 1.1.1.1.1.1.1.1.1.1.1.1.1.1.1.1 .1.1.1.1..1.1.1.1.1.11 ..1.1.1• .11111111. i11111i111111111111111111111 1111111111111111111111i1111111111111111111111111. 1ii11111111111111� . 1 111111 1111111111 1111 1111 11111 1111 1111 1111111111111111111111111111111111111111111111111111� 1111 111111 11111111111111111111111111111 i X1111111111111 111111111111 111111 1111 11111111 11111111111111111111111 11111 111111111111111111111Y• 1111111111111111111111111111111111111111111111111111111111111111111111111111111111111 11111111111 11111111111 111111111111 11111111111 11111 1111 111111111111 1111 111111111111111111111111 1111111 1111 1111111111111111111111111111 1111111111111111111111111111111 �111�111��111111111111111111111111111111111111111111111111�. � .1.1111 �1111111111111111111111111111111111 .1. �1111111111111111111111111111����1111 <1�1111���1111111 �1� 111111111111111111111111111111111 • 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 1 1 1 1111 1 1 1 11 11 111 1M1111111111111111111111111111 11111 11111111111 111111 111111 111111 i 1 1 1 :111 � ! �.1.� 1.1.1.1.1.1.1.1.1.1�1.1.1�1�1 �.1.1�1�1 �. 1�1�1�1�1�1�1�1�1�1�1�1 .1�1�1�1.1� �1�1.1�� 1�1.1�1�1�1.� 1�1�1�F1 ��1�1�1�1�1�1�1�1�1�1�1�1�1�1�1�1�1�1�1�1�1�1�1�1�1�1�1�1�1�1�1�1�1 � � ��1�1�1�1.1�1�� � 1 ��1�1�1�1 ��1�1�1�1�1 � ��1�1�1�1�1.1 � ��1�1�1�1 ��1�1�1�1 ��1�1 ��1�1�1�1�1�1�1�1�1�1 ��1�1�1�1 �!: 3x4 = 3x4 = ` 14 -0-0 14 -0-0 __Plate Offsets (X _[2:0- 0- 0,0 -0-0], [6:0- 2 -0,0- 0-11], P_0- 2 -0,0- 0-11], [9:0- 2- 0,0 -1 -1], [10:0-2-0,0-1-11___ - ___ — LOADING (psf) SPACING 2 -0-0 CSI DEFL in (loc) 1/defl Lid PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.16 Vert(LL) n/a - n/a 999 [ MI120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.09 Vert(TL) 0.00 1 >999 180 BCLL 0.0 * Rep Stress Incr NO j VVB 0.06 Horz(TL) 0.00 8 n/a n/a BCDL 10.0 Code IRC2000/TP12002 (Matrix) Weight: 47 Ib LUMBER TOP CHORD 2 X 4 SPF No.2 Max Uplift WEBS BOT CHORD 2 X 4 SPF No.2 13 = - 119(load case 4) 7 -9 = - 239/156 OTHERS 2 X 4 SPF Stud 10 = - 73(load case 5) 9 = - 144(load case 5) NOTES (11) BRACING Max Gray 1) Unbalanced roof live loads have been considered for this design. TOP CHORD 8 = 137(load case 1) 2) Wind: ASCE 7 -98; 100mph; h =25ft; TCDL= 4.2psf; BCDL= 5.Opsf; Category 11; Exp C; Structural wood sheathing directly applied or 6-0-0 oc purlins. 2 = 240(load case 1) enclosed; MWFRS gable end zone; cantilever left and right exposed ; end vertical left BOT CHORD 11 = 205(load case 1) and right exposed; Lumber DOL =1.33 plate grip DOL =1.33. Rigid ceiling directly applied or 10-0 -0 oc bracing. 12 = 186(load case 6) 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to 13 = 295(load case 1) wind (normal to the face), see MiTek "Standard Gable End Detail" REACTIONS (lb /size) 10 = 175(load case 7) 4) As requested, plates have not been designed to provide for placement tolerances or 8 = 137/14 -0-0 9 = 321(load case 1) rough handling and erection conditions. It is the responsibility of the fabricator to increase 2 = 240/14 -0-0 plate sizes to account for these factors. 11 = 205/14 -0-0 FORCES (Ib) - Maximum Compression/Maximum Tension 5) All plates are 1.5x4 MI120 unless otherwise indicated. 12 = 176/14 -0-0 TOP CHORD 6) This truss requires plate inspection per the Tooth Count Method when this truss is 13 = 295/14 -0-0 1 -2 = 0/35 2 -3 = - 79/46 3-4 = -67/86 chosen for quality assurance inspection. 10 = 166/14 -0-0 4-5 = - 57/113 5-6 = - 57/102 6-7 = -68/53 7) Gable requires continuous bottom chord bearing. 9 = 321/14 -0-0 7 -8 = -75/49 8) Gable studs spaced at 2 -0-0 oc. Max Horz BOT CHORD 9) 1 This truss has been designed for a live load of 20.Opsf on the bottom chord in all 2 = 111(load case 4) 2 -13 = 0/68 12 -13 = 0/68 11 -12 = 0/68 areas where a rectangle 3-6-0 tall by 1 -0-0 wide will fit between the bottom chord and any Max Uplift 10-11 = 0/68 9-10 = 0/68 8-9 = 0/68 other members. 8 = - 22(load case 5) WEBS 10) Provide mechanical connection (by others) of truss to bearing plate capable of 2 = - 88(load case 4) 5-11 = - 158/6 4-12 = - 156/102 3-13 = - 227/144 withstanding 22 Ib uplift at joint 8, 88 Ib uplift at joint 2, 84 Ib uplift at joint 12, 119 Ib uplift 12 = - 84(Ioad case 4) 6-10 = - 152/97 at joint 13, 73 Ib uplift at joint 10 and 144 Ib uplift at joint 9. 11) All Plates 20 Gauge Unless Noted _ Job Truss Truss Type Qty Ply NEFH POWERS 08030 T3 ROOF TRUSS 10 1 -- _ . I__ - . ___ __Job Reference (optional) Truss Engineering Corp., Indian Orchard, MA 01151 5.200 s Dec 2 2003 MiTek Industries, Inc. Mon Apr 12 11:12:19 2004 Page 1 i 1 -1 -0-0 7 -0-0 14 -0-0 1 -0-0 7 -0-0 7 -0-0 Scale =1:20. 5x6 = 3 6.00 12 W1 _ T 1 i I 4 2 N N • • ' 5 1.5x4 11 3x8 = 3x8 = 7 -0-0 I 14 -0-0 7 -0-0 7 -0-0 Plate Offsets (X,Y): [2:0- 8- 2,0- 0- 5],14:0 -8-2,0 -0-51 _ _ ----- _____ LOADING (psf) SPACING 2 -0-0 CSI DEFL in (loc) I /deft Ud PLATES GRIP . TCLL 35.0 Plates Increase 1.15 TC 0.67 Vert(LL) - 0.11 4-5 >999 240 MI120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.58 Vert(TL) - 0.20 4-5 >804 180 BCLL 0.0 * Rep Stress Incr YES WB 0.09 Horz(TL) 0.02 4 n/a n/a BCDL 10.0 Code IRC2000/TPI2002 (Matrix) Weight: 39 Ib LUMBER TOP CHORD 2 X 4 SPF No.2 BOT CHORD BOT CHORD 2 X 4 SPF No.2 4-5 = - 155/842 WEBS 2 X 4 SPF Stud WEBS 3-5 = 0/221 BRACING TOP CHORD NOTES (7) Structural wood sheathing directly applied or 4-10 -2 oc purlins. 1) Unbalanced roof live loads have been considered for this design. BOT CHORD 2) Wind: ASCE 7 -98; 100mph; h =25ft; TCDL= 4.2psf; BCDL= 5.Opsf; Category 11; Exp C; Rigid ceiling directly applied or 10-0 -0 oc bracing. enclosed; MWFRS gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL =1.33 plate grip DOL =1.33. REACTIONS (Ib /size) 3) As requested, plates have not been designed to provide for placement tolerances or 4 = 709 /0-3 -8 rough handling and erection conditions. It is the responsibility of the fabricator to increase 2 = 813/0 -3-8 plate sizes to account for these factors. Max Horz 4) This truss requires plate inspection per the Tooth Count Method when this truss is 2 = 111(load case 4) chosen for quality assurance inspection. Max Uplift 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all 4 = - 177(load case 5) areas where a rectangle 3-6-0 tall by 1 -0-0 wide will fit between the bottom chord and any 2 = - 255(load case 4) other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of FORCES (Ib) - Maximum Compression/Maximum Tension withstanding 177 Ib uplift at joint 4 and 255 Ib uplift at joint 2. TOP CHORD 7) All Plates 20 Gauge Unless Noted i 1 -2 = 0/35 2 -3 = - 1064/247 3-4 = - 1063/238 BOT CHORD 2 -5 = - 155/842 Job Truss I Truss Type I Qty Ply NEFH / POWERS -- 08030 T2GE ROOF TRUSS ;1 1 Job Reference (optional) Truss Engineering Corp., Indian Orchard, MA 01151 5.200 s Dec 2 2003 MiTek Industries, Inc. Mon Apr 12 11:12:18 2004 Page 2 FORCES (Ib) - Maximum Compression/Maximum Tension 1 TOP CHORD 1 -2 = 0/35 2 -3 = - 175/67 3-4 = - 78/104 4-5 = - 54/130 5-6 = - 60/164 6-7 = - 59/198 7 -8 = - 59/224 8-9 = - 59/214 9-10 = - 59/161 10-11 = - 59/102 11 -12 = -55/67 12 -13 = -76/40 13-14 = - 116/68 BOTCHORD 2 -25 = 0/146 24-25 = 0/146 23-24 = 0/146 22 -23 = 0/146 21 -22 = 0/146 20-21 = 0/146 19-20 = 0/146 18-19 = 0/146 17 -18 = 0/146 16-17 = 0/146 15-16 = 0/146 14-15 = 0/146 WEBS 10-18 = - 166/115 11 -17 = - 179/118 12 -16 = - 121/83 13-15 = - 288/193 NOTES (11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7 -98; 100mph; h =25ft; TCDL= 4.2psf; BCDL= 5.0psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL =1.33 plate grip DOL =1.33. 3) Truss designed for wind Toads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable End Detail" 4) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 5) All plates are 1.5x4 MI120 unless otherwise indicated. 6) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 2 -0-0 oc. 9) * This buss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1 -0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 Ib uplift at joint 14, 52 Ib uplift at joint 2, 86 Ib uplift at joint 21, 93 Ib uplift at joint 22, 98 Ib uplift at joint 23, 62 Ib uplift at joint 24, 169 Ib uplift at joint 25, 82 Ib uplift at - joint 19, 94 Ib uplift at joint 18, 99 Ib uplift at joint 17, 57 Ib uplift at joint 16 and 183 Ib uplift at joint 15. 11) All Plates 20 Gauge Unless Noted Job Truss Truss Type Qty Ply I NEFH / POWERS I 08030 T2GE ROOF TRUSS 1 1] I Job Reference (optional) Truss Engineering Corp., .200 s Dec 2 2003 MiTek Industries, Inc. Mon Apr 12 11:12:17 2004 Page 1 g g orp., Indian Orchard, MA 01151 � -1 -0-0� 14 -0-0 27-8 -8 1 -0-0 14 -0-0 13-8 -8 3x4 = Scale = 1:37. • 8 7 9 1 6 10 6.00 1 6 11 ■ ST T ■ 12 4 S 3 T'S 13 i illiillk il 2 1 '..DD . � O• . .O . OO• J•• 4••.•••`•'•' hD O.DDDDDDD.4••D•v••••'.DV•. J• DDOTOOOOO. D•.•••••• 4 ••••44••D.•••••••DDOD. JOO. � � .DDDDDDO� � O• DD4• J. D••••`•'••••• D••'•'•'•'•'•••V•••O•'•'.'•OD'. •OD4'� •VD•O•••D44'.'•••V••D4D•.•o 0 3x4 = iv . .... 3x4 = 5•5 = 5•5 = 27-8 -8 27-8 -8 Plate Off sets (X,Y): [18:0 -2- 8,0.3 -0], [22:0- 2- 5,0 -3-0] - - -__ - -- --- ----- - - - -_- — _ -- - - -- LOADING (psf) SPACING 2 -0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP - ! TCLL 35.0 Plates Increase 1.15 TC 0.22 Vert(LL) n/a - n/a 999 MI120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.10 Vert(TL) 0.02 1 >789 180 BCLL 0.0 • Rep Stress Incr YES WB 0.15 Horz(TL) 0.01 14 n/a n/a BCDL 10.0 Code IRC2000/TPI2002 (Matrix) Weight: 120 Ib LUMBER -- - -_ - -- -- - - -- TOP CHORD 2 X 4 SPF No.2 15 = 392/27 -8-8 Max Gray BOT CHORD 2 X 4 SPF 1650F 1.5E *Except* Max Horz 25 = 402(Ioad case 6) B2 2 X 4 SPF No.2 2 = 189(load case 4) 19 = 216(load case 7) OTHERS 2 X 4 SPF Stud Max Uplift 18 = 204(load case 1) 14 = - 4(load case 4) 17 = 226(load case 7) BRACING 2 = - 52(load case 5) 16 = 133(load case 1) TOP CHORD 21 = - 86(load case 4) 15 = 392(load case 7) Structural wood sheathing directly applied or 6-0-0 oc purlins. 22 = - 93(load case 4) BOT CHORD 23 = - 98(Ioad case 4) FORCES (lb) - Maximum Compression /Maximum Tension Rigid ceiling directly applied or 10-0-0 oc bracing. 24 = - 62(load case 4) TOP CHORD ' 25 = - 169(load case 4) 1 -2 = 0/35 2 -3 = - 175/67 3-4 = - 78/104 REACTIONS (lb/size) 19 = - 82(load case 5) 4-5 = - 54/130 5-6 = - 60/164 6-7 = - 59/198 14 = 168/27 -8-8 18 = - 94(load case 5) 7 -8 = - 59/224 8-9 = - 59/214 9-10 = - 59/161 2 = 277/27 -8-8 17 = - 99(load case 5) 10-11 = - 59/102 11 -12 = -55/67 12 -13 = -76/40 20 = 189/27 -8-8 16 = - 57(load case 5) 13-14 = - 116/68 121 = 209/27 -8-8 15 = - 183(load case 5) BOT CHORD 22 = 204/27 -8-8 Max Gray 2 -25 = 0/146 24-25 = 0/146 23-24 = 0/146 23 = 228/27 -8-8 14 = 168(load case 1) 22 -23 = 0/146 21 -22 = 0/146 20-21 = 0/146 24 = 127/27 -8-8 2 = 277(loadcase 1) 19-20 = 0/146 18-19 = 0/146 17 -18 = 0/146 25 = 402/27-8 -8 20 = 189(load case 1) 16-17 = 0/146 15-16 = 0/146 14-15 = 0/146 19 = 209/27 -8-8 21 = 216(load case 6) WEBS 18 = 204/27 -8-8 22 = 204(load case 1) 8-20 = -149/0 7 -21 = - 175/106 6-22 = - 166/113 17 = 226/27 -8-8 23 = 228(load case 6) 5-23 = - 180/118 4-24 = - 115/82 3-25 = - 300/191 16 = 133/27 -8-8 24 = 127(load case 1) 9-19 = - 175/102 ! Continued on page 2 Job Truss Truss Type Qty Ply NEFH / POWERS 08030 T2 ROOF TRUSS 6 I 1 j — _ Job Reference (optional) Truss Engineering Corp. Indian Orchard, MA 01151 5.200 s Dec 2 2003 MiTek Industries, Inc. Mon Apr 12 11:12:16 2004 Page 1 1 -1 -0-0 7 -3-2 1 14 -0-0 1 20 -8 -14 1 27-8 -8 1 -0-0 7-3 -2 6-8 -14 6-8 -14 6 -11 -10 ICI 4x6 = Scale = 1:37. 4 Pi I . 1 4 l b 1 - 1 1 4 i iiiiii 4 4 4 i 4 • 4 iiiii• 6.00 12 1.5x4 1.5x4 O 3 5 ' 1, \ / 411111111111 440 6 2 1 B1 MI —B2 Mil B3 iii IIIMI IIII 3x8 = 8 9 10 7 5x5 = 6x6 = 6x6 = 1 10 -0-0 1 18 -0-0 1 27-8 -8 1 10 -0-0 8 -0-0 9-8-8 -------- ------ - - - - -- Plate Offsets (X,Y): [2:0- 8- 2,0- 0- 51,.[6:0- 0- 2,0 -1 -9], [7:0- 3- 0,Edge], [8:0- 3- 0,Edge] LOADING (psf) SPACING 2 -0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP . TCLL 35.0 Plates Increase 1.15 TC 0.79 Vert(LL) -0.29 7 -8 >999 240 MI120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.79 Vert(TL) -0.54 2 -8 >605 180 BCLL 0.0 * Rep Stress Incr YES WB 0.36 Horz(TL) 0.10 6 n/a n/a BCDL 10.0 Code IRC2000/TPI2002 (Matrix) Weight: 96 Ib LUMBER 8) NI Plates 20 Gauge Unless Noted TOP CHORD 2 X 4 SPF No.2 TOP CHORD BOT CHORD 2 X 4 SPF 1650F 1.5E `Except* 5-6 = - 2633/604 B2 2 X 4 SPF No.2 BOT CHORD WEBS 2 X 4 SPF Stud 2 -8 = - 595/2267 8-9 = - 252/1537 9-10 = - 252/1537 7 -10 = - 252/1537 6-7 = - 433/2219 BRACING WEBS TOP CHORD 3-8 = - 574/366 4-8 = - 239/846 4-7 = - 237/810 Structural wood sheathing directly applied or 2 -2 -0 oc puffins. 5-7 = - 536/357 BOT CHORD Rigid ceiling directly applied or 8 -11 -13 oc bracing. NOTES (8) 1) Unbalanced roof live loads have been considered for this design. REACTIONS (Ib /size) 2) Wind: ASCE 7 -98; 100mph; h =25ft; TCDL= 4.2psf; BCDL= 5.Opsf; Category 11; Exp C; 6 = 1496 /Mechanical enclosed; MWFRS gable end zone; cantilever left and right exposed ; end vertical left 2 = 1595/0 -3-8 and right exposed; Lumber DOL =1.33 plate grip DOL =1.33. Max Horz 3) As requested, plates have not been designed to provide for placement tolerances or 2 = 189(load case 4) rough handling and erection conditions. It is the responsibility of the fabricator to increase Max Uplift plate sizes to account for these factors. 6 = - 355(load case 5) 4) This truss requires plate inspection per the Tooth Count Method when this truss is 2 = - 433(load case 4) chosen for quality assurance inspection. I 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all FORCES (Ib) - Maximum Compression /Maximum Tension areas where a rectangle 3-6-0 tall by 1 -0-0 wide will fit between the bottom chord and any TOP CHORD other members. 1 -2 = 0/35 2 -3 = - 2672/608 3-4 = - 2298/564 6) Refer to girder(s) for truss to truss connections. 4-5 = - 2274/564 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 355 Ib uplift at joint 6 and 433 Ib uplift at joint 2. Job Truss Truss Type I Qty Pty NEFH / POWERS 08030 T1 GE ROOF TRUSS 1 1 Job Reference _(9 tA)n01 _ -- _ -- Truss Engineering Corp., Indian Orchard, MA 01151 5.200 s Dec 2 2003 MiTek Industries, Inc. Mon Apr 1211:12:15 2004 Page 2 FORCES (Ib) - Maximum Compression /Maximum Tension TOP CHORD 1 -2 = 0/35 2 -3 = - 171/67 3-4 = - 77/118 4-5 = - 53/143 5-6 = - 59/177 6-7 = - 58/211 7 -8 = - 58/237 8-9 = - 58/227 9-10 = - 58/174 10-11 = - 59/115 11 -12 = -53/71 12 -13 = -77/45 13-14 = -98/67 14-15 = 0/35 BOTCHORD 2 -26 = 0/167 25-26 = 0/167 24-25 = 0/167 23-24 = 0/167 22 -23 = 0/167 21 -22 = 0/167 20-21 = 0/167 19-20 = 0/167 18-19 = 0/167 17 -18 = 0/167 16-17 = 0/167 14-16 = 0/167 WEBS 10-19 = - 166/115 11 -18 = - 180/118 12 -17 = - 115/82 13-16 = - 300/190 NOTES (11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7 -98; 100mph; h =25ft; TCDL= 4.2psf; BCDL= 5.Opsf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL =1.33 plate grip DOL =1.33. 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable End Detail" 4) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 5) All plates are 1.5x4 MI120 unless otherwise indicated. 6) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 2 -0-0 oc. 9) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 1 -0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 58 Ib uplift at joint 2, 84 Ib uplift at joint 14, 85 Ib uplift at joint 22, 94 Ib uplift at joint 23, 98 Ib uplift at joint 24, 62 Ib uplift at joint 25, 168 Ib uplift at joint 26, 81 Ib uplift at joint 20, 95 Ib uplift at joint 19, 98 Ib uplift at joint 18, 62 Ib uplift at joint 17 and 168 Ib uplift at joint 16. 11) All Plates 20 Gauge Unless Noted j I 1 Job Truss Truss Type Qty Ply NEFH / POWERS 08030 T1 GE ROOF TRUSS . 1 1 1 1 Job Reference (optional) Truss Engineering Corp., Indian Orchard, MA 01151 5.200 s Dec 2 2003 MiTek Industries, Inc. Mon Apr 1211:12:15 2004 Page 1 � -1 -0-0� 14 -0-0 � 28 -0-0 X 29 -0-0 1 -0-0 14 -0-0 14 -0-0 1 -0-0 -. Scale 1:38.4 3x4 = 8 7 9 6 10 6.00 12 6 11 111 4 12 ill 3 13 i i 2 ■ , r� ■ 1 Ill ■14 *:1 IF ' ' 1 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1'N'1'1'1'1'1'1'1'1'1'1'1'1'1'1 '1'1'1'1'1'1'1'171'1'1'1'1'1'1' 1'1'1'1'1'1'1'1'1'1'1'1'1'11'1 1'1'1'1'1'1'1'1'1'1'1'1' 1'1'1'1'1'1'1'1'1'1'1'1'1'1'1'1 "1'1'1'1'1'1'1'1''1'1'1'1'1' 1'1'1'1'1'1'1'1'1'1'1'1'1'1' 15 I 1'1 O 1 111111111111111 111111 1111111 111: 11111111111111111111111111111 11111111111111 111111 1111111111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 .. 1 1 11 1 1 1 1 1 1 1 11 1 1 1 1 1 _ 11 1 " 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1. 1 1 1 1 1 1 1 1 1 1.1 1 1 1 1 1 1.1 1 1 1 1 1 11 1 1 1 1 1 .1 1 .1 1 1 1 ..1 1 1 1 1 1 1 1 1 1 �- 1.1.1.1.1- 1.1.1.1.1.1,1.1.1 - 1.1,1.1.1.1.E 1. 1. 1. 1- 1- 1- 1- 1- 1- 1.1.1.1 -1.1- 1.1.1.1.1,1.1, 1.1,1.1.1.1.1,1.1.1.1,1.1.1.1.1 1 -1 � �.1- ♦ -1.1 -� 1- 1.1- 1- 1.1.1.1.1.1.1 -1- 1.1.1. 1.1,1.1.1.1.1.1.1, 1.1.1.1.1.1.1. 1,1,,1. 1.1.1.1 -t 1. 1,1,1.1.1.1.1.1 -1 -t 1.1.1.1,1.1.1,1.1. 1.1,1.1,1 -t 1.1.1.1.1.1.1.1.1 t- 1.1.1.1. 1.1.1.1.1.1.1.1.1.1.1.1.1.1.1.1 3x4 = Y 3x4 = 5x5 = 5x5 = 28 -0-0 1 28 -0-0 Plate Offsets ±X,Y): [19:0-2-8,0-3-0],[23:0-2-8,0-3-0] LOADING (psf) SPACING 2 -0-0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP - TCLL 35.0 Plates Increase 1.15 TC 0.22 Vert(LL) n/a - n/a 999 MI120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.09 Vert(TL) 0.02 15 >789 180 BCLL 0.0 * Rep Stress Incr YES WB 0.16 Horz(TL) 0.01 14 n/a n/a BCDL 10.0 Code IRC2000/TP12002 (Matrix) Weight: 122 Ib LUMBER TOP CHORD 2 X 4 SPF No.2 16 = 402/28 -0-0 Max Gray BOT CHORD 2 X 4 SPF 1650F 1.5E *Except` Max Holz 26 = 402(load case 6) 132 2 X 4 SPF No.2 2 = - 179(load case 5) 20 = 216(load case 7) OTHERS 2 X 4 SPF Stud Max Uplift 19 = 204(load case 1) 2 = - 58(load case 5) 18 = 228(load case 7) BRACING 14 = - 84(load case 5) 17 = 127(load case 1) TOP CHORD 22 = - 85(load case 4) 16 = 402(load case 7) Structural wood sheathing directly applied or 6-0-0 oc purlins. 23 = - 94(load case 4) BOT CHORD 24 = - 98(load case 4) FORCES (lb) - Maximum Compression/Maximum Tension Rigid ceiling directly applied or 10-0 -0 oc bracing. 25 = - 62(load case 4) TOP CHORD 26 = - 168(load case 4) 1 -2 = 0/35 2 -3 = - 171/67 3-4 = - 77/118 REACTIONS (lb/size) 20 = - 81(loadcase 5) 4-5 = - 53/143 5-6 = - 59/177 6-7 = - 58/211 2 = 277/28 -0-0 19 = - 95(load case 5) 7 -8 = - 58/237 8-9 = - 58/227 9-10 = - 58/174 14 = 277/28 -0-0 18 = - 98(load case 5) 10-11 = - 59/115 11 -12 = -53/71 12 -13 = -77/45 21 = 190/28 -0-0 17 = - 62(load case 5) 13-14 = -98/67 14-15 = 0/35 22 = 209/28 -0-0 16 = - 168(load case 5) BOT CHORD 23 = 204/28 -0-0 Max Gray 2 -26 = 0/167 25-26 = 0/167 24-25 = 0/167 24 = 228/28 -0-0 2 = 277(load case 1) 23-24 = 0/167 22 -23 = 0/167 21 -22 = 0/167 25 = 127/28 -0-0 14 = 277(load case 1) 20-21 = 0/167 19-20 = 0/167 18-19 = 0/167 26 = 402/28 -0-0 21 = 190(load case 1) 17 -18 = 0/167 16-17 = 0/167 14-16 = 0/167 20 = 209/28 -0-0 22 = 216(load case 6) WEBS 19 = 204/28 -0-0 23 = 204(load case 1) 8-21 = -150/0 7 -22 = - 176/105 6-23 = - 166/114 18 = 228/28 -0-0 24 = 228(load case 6) 5-24 = - 180/118 4-25 = - 115/82 3-26 = - 300/191 17 = 127/28 -0-0 25 = 127(load case 1) 9-20 = - 176/101 Continued on page 2 ;Job I Truss Truss Type Qty 1 Ply NEFH / POWERS 108030 171 ROOF TRUSS 6 11 1 ____ i Job Reference (optional) Truss Engineering Corp., Indian Orchard, MA 01151 5.200 s Dec 2 2003 MiTek Industries, Inc. Mon Apr 1211:12:14 2004 Page 1 � -1 -0-0� 7-3 -2 1 14 -0-0 - 20 -8 -14 28 -0-0 1 29 -0-9 1 -0-0 7-3-2 6-8 -14 . 6-8 -14 7-3 -2 1 -0-0 4x6 = . Scale = 1:38.4 4 e 1 i 6.00 FlY 1.5x4 \ 1.5x4 /i 3 5 ' \ a . 2 6 _16\ 1 NW NIP II o al a 3x8 = 9 10 11 8 3x8 = 6x6 = 6x6 = 10 -0-0 I 18 -0-0 1 28 -0-0 10 -0-0 8 -0-0 10 -0-0 _Plate Offsets (X,Y): [2:0- 8- 2,0 -05], [6:0 -8-2,0 -0.51, [8:0- 3- 0,Edge], [9:0- 3- 0,Edge] __ - -_ _ __ _ _ ___ LOADING (pst) SPACING 2 -0-0 CSI 1 DEFL in (loc) I/defl Ud PLATES GRIP - TCLL 35.0 Plates Increase 1.15 TC 0.79 Vert(LL) - 0.30 8-9 >999 240 MI120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.79 Vert(TL) -0.55 2 -9 >605 180 BCLL 0.0 Rep Stress Incr YES WB 0.36 I Horz(TL) 0.10 6 n/a n/a BCDL 10.0 1 Code IRC2000/TPI2002 (Matrix) 1 Weight: 98 Ib LUMBER TOP CHORD 2 X 4 SPF No.2 TOP CHORD BOT CHORD 2 X 4 SPF 1650F 1.5E 'Except* 5-6 = - 2698/613 6-7 = 0/35 B2 2 X 4 SPF No.2 BOT CHORD WEBS 2 X 4 SPF Stud 2 -9 = - 589/2291 9-10 = - 246/1560 10-11 = - 246/1560 8-11 = - 246/1560 6-8 = - 410/2291 BRACING WEBS TOP CHORD 3-9 = - 574/366 4-9 = - 239/845 4-8 = - 240/845 Structural wood sheathing directly applied or 2 -2 -0 oc purlins. 5-8 = - 574/366 BOT CHORD Rigid ceiling directly applied or 9-0-6 oc bracing. NOTES (7) 1) Unbalanced roof live loads have been considered for this design. REACTIONS (Ib /size) 2) Wind: ASCE 7 -98; 100mph; h =25ft; TCDL= 4.2psf; BCDL= 5.0psf; Category 11; Exp C; 2 = 1607/0 -3-8 enclosed; MWFRS gable end zone; cantilever left and right exposed ; end vertical left 6 = 1607/0 -3-8 and right exposed; Lumber DOL =1.33 plate grip DOL =1.33. Max Horz 3) As requested, plates have not been designed to provide for placement tolerances or 2 = 179(load case 4) rough handling and erection conditions. It is the responsibility of the fabricator to increase Max Uplift plate sizes to account for these factors. ' 2 = - 435(load case 4) 4) This truss requires plate inspection per the Tooth Count Method when this truss is 6 = - 435(Ioad case 5) chosen for quality assurance inspection. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all FORCES (Ib) - Maximum Compression /Maximum Tension areas where a rectangle 3-6-0 tall by 1 -0-0 wide will fit between the bottom chord and any ' TOP CHORD other members. ' 1 -2 = 0/35 2 -3 = - 2698/613 3-4 = - 2324/569 6) Provide mechanical connection (by others) of truss to bearing plate capable of 4-5 = - 2324/569 withstanding 435 Ib uplift at joint 2 and 435 Ib uplift at joint 6. 7) All Plates 20 Gauge Unless Noted Job I Truss Truss Type Qty Ply NEFH / POWERS 1 08030 M2 MONO TRUSS 7 1 Job Reference (optional) Truss Engineering Corp., Indian Orchard, MA 01151 5.200 s Dec 2 2003 MiTek Industries, Inc. Mon Apr 1211:12:13 2004 Page 1 5 -0-0 2 -10 -7 1 -0-0 2 -10 -7 2 -1 -9 5 • Scale = 1:14.3 2x3 Q 6.00 4 � � ,': Aiiiiiiiill r m /gi oeio000.00iim -1-0-0 11 . 10 ..41° A B1 3x4 -'/ Io '/ . ,� 1 6 3x6 /i 3x6 H 4 -10-4 5 4 -10-4 0 -1 -12 Plate Offsets (X,Y): [2:0- 2- 0,0- 0- 6],[6:0 -2- 12,0 -1 -0] _ -,___ - -- - - - --- LOADING (psf) SPACING 2 -0-0 CSI DEFL in (loc) Udefl Lid PLATES GRIP TCLL 70.0 Plates Increase 1.15 TC 0.17 Vert(LL) n/a - n/a 999 MI120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.20 Vert(TL) -0.05 2 -6 >999 180 BCLL 0.0 • Rep Stress Incr YES WB 0.09 Horz(TL) 0.00 6 n/a n/a BCDL 10.0 Code IRC2000/TP12002 (Matrix) Weight: 21 lb LUMBER 8) All Plates 20 Gauge Unless Noted TOP CHORD 2 X 4 SPF No.2 TOP CHORD BOT CHORD 2 X 4 SPF No.2 2 -3 = - 444/60 3-4 = - 288/69 4-5 = -86/44 WEBS 2 X 4 SPF Stud 5-6 = - 131/38 SLIDER BOT CHORD Left 2 X 4 SPF No.2 1-11-3 2 -6 = - 101/257 WEBS BRACING 4-6 = - 343/142 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins, except end verticals. NOTES (8) BOT CHORD 1) Wind: ASCE 7 -98; 100mph; h =256; TCDL= 4.2psf; BCDL= 5.Opsf; Category II; Exp C; Rigid ceiling directly applied or 10-0 -0 oc bracing. enclosed; MWFRS gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL =1.33 plate grip DOL =1.33. REACTIONS (Ib /size) 2) As requested, plates have not been designed to provide for placement tolerances or 2 = 592/0 -3-8 rough handling and erection conditions. It is the responsibility of the fabricator to increase 6 = 406/0 -1 -8 plate sizes to account for these factors. Max Holz 3) This truss requires plate inspection per the Tooth Count Method when this truss is 2 = 153(load case 3) chosen for quality assurance inspection. Max Uplift 4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all 2 = - 129(load case 4) areas where a rectangle 3-6-0 tall by 1 -0-0 wide will fit between the bottom chord and any 6 = - 95(load case 4) other members. 5) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 -1995 angle to FORCES (Ib) - Maximum Compression /Maximum Tension grain formula. Building designer should verify capacity of bearing surface. TOP CHORD 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6. 1 -2 = 0/3 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 129 Ib uplift at joint 2 and 95 Ib uplift at joint 6. ! Job Truss I Truss Type 1 Qty I Ply ' NEFH / POWERS 08030 9 g M1 MONOTRUSS L? 1 I Job Reference (optional__..______ Apr 12 — Truss En ineerin Co 1 1 1.12:12 2004 Pa Indian Orchard, MA 01151 5.200 s Dec 2 2003 MiTek Industries, Inc. Mon ge 1 1 -1 -0-0 � 3-5-10 6 -0-0 1 -0-0 3 -5-10 2-6-6 2x3 f I Scale = 1:18.T 5 i 2x3 - 6.00 12 4 IIP N 3 2 111 I I. B1 I ' 1" o ■ 3x4 6 3x6 ii 3x6 11 5 -10-4 6 5 -10-4 0 -1 -12 Plate Offsets (X,Y): [2:0- 2- 0,0-0- 6],_[6:0- 2- 7,0 -1 -1] __ -_ _ _ -_ _ ---- - - - - -- - - - - - -- LOADING (psf) SPACING 2 -0-0 CSI DEFL in (loc) 1 /deft Ud PLATES GRIP - TCLL 70.0 Plates Increase 1.15 1 TC 0.24 Vert(LL) n/a - n/a 999 MI120 197/144 TCDL 7.0 Lumber Increase 1.15 , BC 0.28 Vert(TL) -0.11 2 -6 >665 180 1 BCLL 0.0 * Rep Stress Incr YES WB 0.13 Horz(TL) 0.00 6 n/a n/a ! BCDL 10.0 Code IRC2000/TPI2002 (Matrix) Weight: 25 Ib LUMBER 8) All Plates 20 Gauge Unless Noted TOP CHORD 2 X 4 SPF No.2 TOP CHORD BOT CHORD 2 X 4 SPF No.2 2 -3 = - 551/80 3-4 = - 375/89 4-5 = - 106/50 WEBS 2 X 4 SPF Stud 5-6 = - 150/43 SLIDER BOT CHORD Left 2 X 4 SPF No.2 1 -11 -3 2 -6 = -123/335 WEBS BRACING 4-6 = - 442/179 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. NOTES (8) BOT CHORD 1) Wind: ASCE 7 -98; 100mph; h =25ft; TCDL= 4.2psf; BCDL= 5.0psf; Category II; Exp C; Rigid ceiling directly applied or 10-0 -0 oc bracing. enclosed; MWFRS gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL =1.33 plate grip DOL =1.33. REACTIONS (Ib /size) 2) As requested, plates have not been designed to provide for placement tolerances or 2 = 676/0 -3-8 rough handling and erection conditions. It is the responsibility of the fabricator to increase 6 = 496/0 -1 -8 plate sizes to account for these factors. Max Horz 3) This buss requires plate inspection per the Tooth Count Method when this truss is 2 = 179(load case 3) chosen for quality assurance inspection. Max Uplift 4) ' This truss has been designed for a live Toad of 20.Opsf on the bottom chord in all 2 = - 142(load case 4) areas where a rectangle 3-6-0 tall by 1 -0-0 wide will fit between the bottom chord and any 6 = - 115(Ioad case 4) other members. 5) Bearing at joint(s) 6 considers parallel to grain value using ANSUTPI 1 -1995 angle to FORCES (Ib) - Maximum Compression/Maximum Tension grain formula. Building designer should verify capacity of bearing surface. TOP CHORD 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6. 1 -2 = 0/3 7) Provide mechanical connection (by others) of truss to bearing plate capable of L withstanding 142 Ib uplift at joint 2 and 115 Ib uplift at joint 6. Job I Truss Truss Type i Qty Ply I NEFH / POWERS I 08030 i G6 ROOF TRUSS 1 (optional) - _ i ! � !Job Reference I Truss Engineering Corp., Indian Orchard, MA 01151 5.200 s Dec 2 2003 MiTek Industries, Inc. Mon Apr 1211:10:58 2004 Page 1 3 -9 -11 6-6-0 9 -2-5 13 -0-0 3 -9 -11 2-8-5 2-8-5 3 -9 -11 4x5 I I Seale: 3/8 " =V 3 3x6-- 10.00 12 3x6 1 4 2 'i /b • 5 I A • Ems E ► ∎, N '61111111111111 a !��IIIMIII■:■III�111► I . 9 8 10 7 11 6 12 13 �� 5x6 i MSH29 4x9 7x8 = MSH29 4x9 MSH29 MSH29 • MSH29 MSH29 3 -9 -11 � 6-6-0 9-2-5 13 -0-0 3 -9 -11 2-8-5 2-8-5 3 -9 -11 Plate Offsets (X,Y): 16:0 -4-8,0 -0-41, 17:0 -4-0,0 -4-12] -- -- - --- - — _ -- - -- -- LOADING (psf) SPACING 2 -0-0 CSI DEFL in (loc) 1 /deft Lid PLATES GRIP _ TCLL 35.0 Plates Increase 1.15 TC 0.33 Vert(l.l.) -0.06 7 >999 240 MI120 197/144 TCDL 7.0 Lumber Increase 1.15 BC 0.37 Vert(TL) - 0.09 6-7 >999 180 BCLL 0.0 * Rep Stress Incr NO WB 0.60 Hcrz(TL) 0.02 5 n/a n/a BCDL 10.0 Code IRC2000liP12002 (Matrix) 1 Weight: 164 Ib LUMBER 5) As requested, plates have not been designed to provide for placement tolerances or TOP CHORD 2 X 4 SPF No.2 TOP CHORD rough handling and erection conditions. It is the responsibility of the fabricator to increase BOT CHORD 2 X 8 SYP DSS 1 -2 = - 5657/1386 2 -3 = - 4075/1084 3-4 = - 4075/1085 plate sizes to account for these factors. WEBS 2 X 4 SPF Stud *Except* 4-5 = - 5677/1395 6) This truss requires plate inspection per the Tooth Count Method when this truss is W3 2 X 4 SPF No.2 BOT CHORD chosen for quality assurance inspection. WEDGE 1 -9 = - 1032/4084 8-9 = - 1032/4084 8-10 = - 1032/4084 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all Left: 2 X 4 SPF Stud, 7 -10 = - 1032/4084 7 -11 = - 968/4116 6-11 = - 968/4116 areas where a rectangle 3-6-0 tall by 1 -0-0 wide will fit between the bottom chord and any Right: 2 X 4 SPF Stud 6-12 = - 968/4116 12 -13 = - 968/4116 5-13 = - 968/4116 other members. WEBS 8) Provide mechanical connection (by others) of truss to bearing plate capable of BRACING 2 -8 = - 520/2203 2 -7 = - 1608/530 3-7 = - 1277/4855 withstanding 1587 Ib uplift at Joint 1 and 1336 Ib uplift at joint 5. TOP CHORD 4-7 = - 1660/545 4-6 = - 538/2267 9) Use USP MSH29 (With 10d nails into Girder & 10d nails into Truss) or equivalent Structural wood sheathing directly applied or 5-0-0 oc purlins. spaced at 2 -0-0 oc max. starting at 2 -0-12 from the left end to 12 -0-12 to connect BOT CHORD NOTES (13) truss(es) T2 (1 ply 2 X 4 SPF) to back face of bottom chord. Blocking required above the Rigid ceiling directly applied or 10-0 -0 oc bracing. 1) 2 -ply truss to be connected together with 10d Common(.148 "x3 ") Nails as follows: heel of the tamed truss to reach full uplift capacity. (See MiTek's "Hanger Blocking Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc. Detail" for blocking installation.) REACTIONS (Ib /size) Bottom chords connected as follows: 2 X 8 - 2 rows at 0-7 -0 oc. 10) Fill all nail holes where hanger is in contact with lumber. 1 = 6334/0 -3-8 Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc. 11) WARNING: The following hangers are manually applied but fail due to geometric 5 = 5619/0 -3-8 2) All loads are considered equally applied to all plies, except if noted as front (F) or back considerations: MSH29 on back face at 4-0-12 from the left end, MSH29 on back face at Max Horz (B) face in the LOAD CASE(S) section. Pry to ply connections have been provided to 6-0-12 from the left end. 1 = - 217(load case 2) distribute only Toads noted as (F) or (B), unless otherwise indicated. 12) Special hanger(s) or other connection device(s) shall be provided sufficient to support ! Max Uplift 3) Unbalanced roof live loads have been considered for this design. concentrated load(s) 1607.21b down and 434.91b up at 0 -1 -12, and 167.71b down and 1 = - 1587(Ioad case 4) 4) Wind: ASCE 7 -98; 100mph; h =25ft; TCDL= 4.2psf; BCDL= 5.Opsf; Category 11; Exp C; 4.31b up at 12 -10-4 on bottom chord. The design /selection of such special connection 5 = - 1336(load case 5) enclosed; MWFRS gable end zone; cantilever left and right exposed ; end vertical left device(s) is the responsibility of others. and right exposed; Lumber DOL =1.33 plate grip DOL =1.33. 13) All Plates 20 Gauge Unless Noted FORCES (Ib) - Maximum Compression/Maximum Tension * * * ** IMPORTANT NOTE * * * ** It is the sole responsibility of the retailer to supply all attached drawings and information to their customer for review and approval. Any and all changes must be received by Truss Engineering prior to the cancellation date. Any changes received after cancellation date may result in added charges and delay of order. No response before cancellation date will be perceived as a full approval of order. Truss Engineering is responsible for supplying only the material as listed on the order. SUB-TOTAL Deliveries are F.O.B. our truck to jobsite. Inability to access the jobsite or take delivery of order may result in additional charges. GRAND TOTAL Contractor Copy of Order 3 7 � R a /S�Q � WORK ORDER #08030 ORDER DA E: 04/12/04 TRUS , 181 GOODWIN ST Deliver Week Ending: 05/01/04 ENGINEERING PO BOX 51027 CORPORATION INDIAN ORCHARD, MA 01151 Cancellation Date:04 /16/04 r ∎ ∎ ∎ ∎ ∎ ∎ ∎/ Job: NEFH / POWERS MANUFACTURERS OF ROOF & FLOOR TRUSSES POWERS Phone (413) 543 -1298 Fax (413) 543 -1847 Toll Free (800) 456 -0187 NORTHAMPTON, MA Sold To:A. Boilard Sons, Inc. P.O. Box 51065 P0:45487 Indian Orchard, MA 01151 Ordered By: John Bolduc Attn:John Bolduc Phone: (413)- 543 -4100 Our Salesman: John Goodrich Requested Delivery: / / LOADING TCLL- TCDL- BCLL -BCDL ROOF TRUSSES INFORMATION 35.0,7.0,0.0,10.0 ROOF TRUSS SPACING:24.0 IN. O.C. (TYP.) LAYOUT BYJFG ON: 04/12/04 PROFILE QTY PITCH TYPE BASE O/A LUMBER OVRHG / CANT I SHIPPING I UNIT UNIT TOTAL PLY TOP 1 BOT TRUSS ID SPAN SPAN TOP BOT LEFT � RIGHT WIDTH WEIGHT PRICE PRICE 1 GIRDER ® 06 -01 -05 � 82 2 Ply 10.001 0.00 G6 113 - 00_00 13 - 00 - 00 2 X 4 2 X 8 I _ - MONO TRUSS 01 -00 -00 03 - - 25 AA 7 6.00 0.00 M1 06 -00 -00 06 -00 -00 2 X 4 2 X 4 05 -00 -00 05 -00 -00 2 X 4 2 X 4 7 1 s.00 0.00 MONO A 2RUSS 01-00-00 4 03 21 6 6.00 0.00 Ti N 28-00-00 28 -00 -00 1 L2 X 4 2 X 4 01 -00 -00 01 -00 -00 07 98 - - — - 1 2 X- -- 1 6.00 0.00 T1 GE 28 -00 -00 28 -00 -00 12 X 4 2 X 4 07 -09 -15 121 _ L GABLE � 01 -00 -00 01- SPECIAL 01 -00 -00 6 6.00 0.00 T2 28 -00 = 00 27 -08 -08 2 X 4 2 X 4 07 _ T 96 GABLE 01 -00 -00 ((((j��� j �� -III 1 6.00 0.00 T2GE 28 -00 -00 27 -08 -08 2 X 4, 2 X 4 07 - - 119 10 6.00 0.00 SPECIAL 14 -00 -00 14 -00 -00 2 X 4j 2 X 41 101 -00 -00 T3 04 - 03 - 15 39 GABLE 01 -00 -00 04 - - 47 1 6.00 0.00 T3GE 14 -00 -00 14 -00 -00 2 X 4� 2 X 4 ® SPECIAL 09 110 3 10.00 0.00 T4 20 -03 -08 20 -03 -08 2 X 4 2 X 4 ® 1 GABLE 09 109 1 10.00 0.00 T4GE 20 -03 -08 20 -03 -08 2 X 4 2 X 4 ® SPECIAL 09 -06 -14 109 7 10.00 0.00 T5 20 -03 -08 20 -00 -00 2 X 4 2 X 4 -- --- -- -- -- GABLE 01 -00 -00 01 -00 -00 06 -07 -09 58 i 1 1 10.00 0.00 T6GE 13 -00 -00 13 -00 -00 2 X 412 X 4 ROOF SUB - TOTAL: ITEMS QTY ITEM NAME ITEM TYPE 1 NOTES 1 IT TA L PRI P 6 MSH29 Hanger I I l ITEMS SUB - TOTAL: i - 4 ow $11.9A I TiA 311612 - P.7 ... q c;7 -.4 4 ........??. .1 1 -1 -- -2 r,...1 .... 1-4-,1 0 ,,e),„-rf 7 ,- ) ?tivy 01 .47d (y-754 ) 5(':i .. r.((fl _ 1 . II' 1 /1 I -'''' 0/ 9 2 / \in-P-2 Y 4 ti — 1 .i,....j, ?....7 gi 5 N4. t . D6' ), , , , . il 6 i °/,± '"'''`/"',,w,L, s '', i •.7 gni 1 ia li 5 ) 6 1 , I . 1 1 111111111E1111111MV s - I 1 t t i 1 1111 ql I I I II I k 1 11111 1 - - — - 1 . ! ME 1 li 1 i \\ - 1 t I 1 t 1 . 1 , \ W "A 11111111 17SEMIIINIIIINFATI11 II INNSIMIIINMINIIMINIIIIIIIIIIIIIN INO il - 6 11 IP 01111 r \ 1 1 --.... op _....,...............____ , , _..c., , 4 ini .. . ..... ..... _ . Il 1 ,, • . ‘,‘ , .., ,,.., . .. _____ . • , ,.... 1,, ("1 )17 d-r) 1 .. `"'d , 'A 2.-- ? S -Vg ¢ fit fPT - (City riff dortip tpinn • 11" = � .. r 9. ' �' r i =y.i :ail ► 1855AChliStttB "' i � . DEPARTMENT OF BUILDING INSPECTIONS I -=-7---E= =E _ =i_ INSPECTOR 212 Main Street • Municipal Building ',-- , Northampton, MA 01060 pi S`,y e HOME OWNER EXEMPTION ACKNOWLEDGEMENT The State of Massachusetts allows the homeowner the right under 780CMR 108.3.4 to act as his /her construction supc :.' sor. The state defines "Homeowner" as, " Person(s) who owns a parcel on which he /she resides or intends to be, a one or two famil dwelling, attached or detached structures accessory to such use and/or farm structures. A person who constructs more than one home in a two -year period shall not be considered a home owner." The building department for the City of Northampton wants any person(s) who seek to use the, home owner exemption, to act as their own construction supervisor, to be aware that by doing so you become responsible for compliance with state building codes and regulations. The inspection process requires that the building department be called to inspect work at various stages, which include foundation/footings (before backfill), sonotube holes (before Dour), a rough building inspection (before work is concealed), insulation inspection (if required) and a final building inspection.;The building department requires these inspections before the work is concealed, failure to secure these inspections can result in failure to obtain a certificate of occupancy until the work can be inspected. If the homeowner hires other trades to perform work (electrical, plumbing & gas) the homeowner will be responsible to make sure that the trades hired secure their proper permits in conjunction to the building permit issued, and that they get their required inspections. Failure of the individual trades to secure the permits and inspections as required can DELAY the project until such time as the proper permits and inspections are J ade J 1 4 f . ' .� 1 understand the above. (Home owner /residents signature requesti g exemption) I will call to schedule all required building inspections necessary for the building permit issued to me. Date V / t D5 Address of work location 4 / ) C f 701/4 — Pr i v -� - (c1- c ✓Af bl0L a 1 - ttntr p f • / �-\ v- }C o� GIN of �QZ"fl ! i f WV, N "3 I ..61 s31;cllnsr1!a' � !- @ te ter/►! • to" --4--""--•,••• DEPARTMENT OP IIUILD1NG INSPECTIONS • 212 Main Street. ' Municipal Building Northampton, Mass. 01060 r ' ' WORKERS COMPENSATION NSI RACE AFFIDAVIT 1, __ _�.._.c47 _ ` b - C 4_ - - - -- - - -- ............... - - -- (liccnsxJpermittcc) with a principal place of business/residence at: — ` I e T ` p r e ve leru2- -e-c_. Pt it (l:hone') /: git 6 7 37 (sa rt/c ty /s p) do hereby certify, under the.pains and penalties of perjury, that ( ) I am an employer providing tile followineworker's compensation coverage For my employees worldng on this job: - r • (Lnsur-_-n= Co car r•) (Policy Nu_nbcr) C'' :pimtion Dat.e) - ( ) I am a sole proprietor, general contractor or homeowner (cistie orie) and have hired the connactprs listed below wbo have the following worker's coDpensation policies: Mame of Contractor) (Insuranc;: Cornoanyi ?oucr Numlc:) ( xpiriuoi? Dntc) (N: me of Contranor) (1n_sarancc Company/Policy Number) (11 Date) (Name of Conlydelo;) (1.nsur Compa.oy/Policy Namb -r) (Expi scion Date) - f (Name of Contractor) (Lasuran Company/Policy Numb :r) (Expiration DaLL) - (anxh ad'Srt:ocn! elect . ifncc. -- to a,GUd_ infortnanoa pc-uaniott to all occc— _C.o:-o) • {) 1 am a sole proprietor and have no one worEng for me- I am,a home owner perforrning all the work myself. NOTE: p! bc ccryrc t1:at w'Iz.Ic bcmr-0w-acra wbo ccaplcy pecoas to do m-r•.te,co c rupair work txi . d "T-u - "o of Dot tnoce th_a tb h.3 in u'1ieb the bocnoowocr mild= or co th.c prow s,-tpurtan tbcoo a.-t ooc t-), -.1.1y eecd, •ni to bc ttxployes ,,re-- the wca-1; cta Act (G1.1I52s 1(5)). e.ppticatico by a bomeoa»e for c lieo±_ cc porrnit tr=y e•ideaoc the legal ctanu of en •=vloyx ueder tho Wor4.ort Cec ..lion Act_ 1 undo mktard dux a copy of this alt ®cat ra.y be forwarded to the pcganmma of 1 • ilacdcaU' C45... of ism "o.- rot t6. covtn vci6 pupa AM [hot L-iha-c to saauc =tics Sc oa 25 A of MOL 152 cm I4 to the to:politico of citniaal po.altia coos:airs of a floc of up to S1,100.00 and/or jarpriscsozoe=d of up to ooc yev end civil pcoal'ua to the focal of a Stop Work Ord• .ad a • firm 0(5100.00 a thy ag josi tnc _____ • For dcp<rta.�� use only . — 1 � V2 l t`Itirnl) vt, 10 Si 10•A , f L . — crmittt c -- . , , , SECTION 8 -I CONSTRUCTION SERVICES , 8.1 Licensed Construction Supervisor: Not Applicable ❑ ` Name of License Holder : License Number Address Expiration Date Signature Telephone Kilec ete E or r pre `ne ® } _ �._ < - ° .__ Not Applicable ❑ Company Name Registration Number - _— — Address Expiration Date Telephone - SECTION 10- WORKERS' COMPENSATION INSURANCE AFFIDAViT(M.G.L c. 152, §25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes ❑ No ❑ a, - r The current exemption for "homeowners" was extended to include Owner - occupied Dwellings of one (1) or two(2) families and to allow such homeowner to engage an individual for hire who does not possess a license, provided that the owner acts - as supervisor. CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner: Person (s) who own a parcel of land on which he /she resides or intends to reside, on which there is, or is intended to be, a one or two family dwelling, attached or detached structures accessory to such use and/ or farm structures. A person who constructs more than one home in a two -year period shall not be considered a homeowner. Such "homeowner" shall submit to the Building Official, on a form acceptable to the Building Official, that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time, during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152 (Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death) of the Massachusetts General Laws Annotated, you may be liable for person(s) you hire to perform work for you under this permit. The undersigned "homeowner" certifies and assumes responsibility for compliance with the State Building Code, City of Northampton Ordinances, State and Local Zoning Laws and �of Massachusetts General Laws Annotated. Homeowner Signature 1110,,, i/ P i SECTION 5- DESCRIPTION OF PROPOSED WORK (check all applicable) New House ❑ Addition ❑:; Replacement Windows Alteration(s) ED Roofing Or Doors 0 Accessory Bldg. ❑ Demolition El New Signs [II] Decks [p Siding [I]] Other [E rief Description of Proposed Work: k: po iL5 C w�. nn.l ca V(A- Ptd 17)tR w r 5 r � i 1. L u, t 111111///// Alteration of existing bedroom Yes 'q( No Adding new bedroom Yes )4 No / �� Attached Narrative Renovating unfinished basement X Yes No Plans Attached Roll Sheet � ce, teaµ sa `61ase'a , •.9 d th o�c xtar'n iouslnq, rrmDIet uo t : a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No . I. Septic Tank City Sewer Private well City water Supply SECTION Ta - ' OWNER AUTHORIZATION TO COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING - PERMIT I, , as Owner of the subject property hereby authorize to act on my behalf, in all matters relative to work authorized by this building permit application. Signature of Owner Date L ' v 1.---"(-•...e 1, , as Owner /Authorized Agent hereby declare that the stajements and inform on on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. ' Prin ame II IP P f / /ilk ( o � Gr /6 s- D to / Signature of f / er� a L e tion 4. ZONING All InformatioN Must Be Completed. Permit Can Be Denied Due To Incomplete Information ic Existing Proposed Required by Zoning I t f . - This column to be filled in by Building Department Lot Size Frontage I . ' Setbacks Front 1 I 1 Side L, ' R: L:' i R:i 3 ! Rear Building Height , _.._ , Bldg. Square Footage i % I 1 i Open Space Footage % (Lot area minus bldg & paved I___j 1 f € parking) . # of Parking Spaces f ` Fill: I (volume'* Location) A. Has a Special Permit /Variance /Finding ever been issued for /on the site? NO 0 DON'T KNOW 0 YES 0 IF YES, date issued:` IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DONT KNOW 0 YES 0 IF YES: enter Book Page and /or Document # B. Does the site contain a brook, body of water or wetlands? NO 0 DONT KNOW 0 YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Q Obtained Date Issued: C. Do any signs exist on the property? YES 0 NO 0 IF YES, describe size, type and location: I D. Are there any proposed changes to or additions of signs intended for the property ? YES 0 NO 0 IF YES, describe size, type and location: j E. Will the construction activity disturb (clearing, grading, excavation, or filling) over 1 acre or is it part of a common plan that will disturb over 1 acre? YES 0 ,- NO 0 IF YES, then a Northampton Storm Water Management Permit from the DPW is required. •4 is e . a ..y I .. r City of N ?amp � r ,�� din g Department ' . �iirl `� � i Main Street 4, �» c. : LI t , Room 100 e y F Northampton, MA 01060 �� A� 1b n 3 -587 =1240 Fax 413- 587 -1272 Ala AF icii Y f C + I N, ' �R(JC T, A�TER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 - SITE " INFORMATION 1 1 Property Address: a F This section to be by office � c ^ J 1c e. o J r, Map Lo Unit, �� la F' Pir � �. A 0 a- Z one r Overla Di rElm St D stmt . _ _ CB Dist nct " SECTION 2 - PROPERTY OWNERSHIP /AUTHORIZED AGENT 2.1 Owner of Record: e s ' I i--C) I�q / .,1e( ��,,,4 DI-,ve l Mfl of062 Name (Pr nt 1 Current Maili Ad ress: ss 3 ) 0 �-7/ c��i Telephone Y ( 2 _ , ---- y t-/ _. / 7 '7 1 , mot ,, 2.2 A rized Agent: Name (Print) Current Mailing Address: Signature Telephone SECTION 3 - ESTIMATED CONSTRUCTION? COSTS ` Ite Estimated ) to Official Use Only completed by Cost permit (Dollars applicant be 1. Building ®' d, 3� �� (a) Building Permit Fee 2. Electrical is '1 c ' ! (b) ite T 1 Est Construct ion otal fro Cost (6) of 3. Plumbing Building Permit Fee 4. Mechanical (HVAC) 4 to o 5. Fire Protection / V 6. Total = (1 + 2 + 3 + 4 + 5) (d 3 D y Check Number /'9 6`—' i This Section For Offiicial Use Only Building Permit Num be Issued: r. Date Signature: r Building Commissioner /Inspector of Buildings Date • File # BP- 2005 -1112 APPLICANT /CONTACT PERSON DARLING JEFFREY & BRENDA ADDRESS/PHONE 15 ICE POND DR FLORENCE (413) 584 -6737 0 PROPERTY LOCATION 15 ICE POND DRIVE 7I5le MAP 37 PARCEL 092 001 ZONE SR THIS SECTION FOR OFFICIAL USE ONLY: .._, PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out /(� ii ,c5 Fee Paid / ! ( e ui ,c5/ Typeof Construction: BASEMENT RENOVATION ( PLAYROOM WITH FUTURE BATHROOM) New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/ Statement or License 3 sets of Plans / Plot Plan THE FO LOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFO ATION PRESENTED: pproved Additional permits required (see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND /OR Special Permit With Site Plan Major Project: Site Plan AND /OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received & Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street C 'ssion ,____- e 5" j" Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning & Development for more information. • Z9•432 allh ova vial** Mig .52 . 41<- 74 **It* eat i•At 06, 0 itiv 7;). • M 4117 V 1 • CITY OF NORTHAMPTON, MASSACHUSETTS a, DEPARTMENT OF PUBLIC WORKS UMW t', 125 Locust Street • Northampton, MA 01060 413 -587 -1570 Fax 413 - 507 -1576 Samuel B. Brindis, RE. Director, City Engineer Gullford B. Mooring, P.E. Assistant Director et Public Works BOARD OF PUBLIC WORKS DRIVEWAY PERMIT • GENERAL INSTRUCTIONS AND REGULATIONS 1. A "Driveway Permit" is required in all cases where a new curb cut or an alteration to an existing curb cut is proposed on a City public way. 2. Driveway permits issued by the Board of Public Works (BPW) shall be attached to and become part of the "Building Permit" issued by the Building Inspector. 3. Prior to the issuance of a "Building Permit" the owner of any lot to be serviced by a new driveway shall apply to the BPW for a "Driveway Permit" by completing the pertinent portions of the permit (see attached). Once the location of the driveway is approved by the BPW, a building permit may be issued. 4. The Building Inspector shall not issue an "Occupancy Permit" unless the driveway to the lot has been approved by the BPW. 5. By the issuance of a driveway permit for the stated location, neither the City of Northampton nor the Department of Public Works imply that no drainage problems will result with the driveway when constructed. Properties situated or driveways installed in low lying areas in the path of the natural drainage will be subject to water problems. These problems may include water sheeting across roadways adjacent to the driveway. The City and the DPW assume no responsibility for any such drainage problems. The owner of the property is responsible for constructing and maintaining the driveway with adequate provision for natural • water runoff situations. • ' b'muel B Brindis, P.E. Director of Public Works C:uvlyFiles\Lyn1Driveway Perini( General Instructions • (SUBJECT TO ATTACHED CONDITION 1 & 2) D50 -04 Permit No. Conditions: Driveway Permit In lieu of plan approved by City Engineer I agree to the following added conditions: 1. I will contact the Department of Public Works and have an inspector check and approve the graded gravel base prior to paving to insure compliance with slope and location; 2. I further agree that if in the inspections any of the permit conditions are not met that I will at no expense to the City remove and replace the driveway as directed by the City Engineer. By: Petitioner Jim Powers 413 - 584 -4204 Note: The Public Works Department recommends that you provide a plan showing the proposed driveway with grades and location in the future to avoid possible expense which you will incur by not getting approval of actual plans in advance. cc: Building Inspector Permit No D50 -04 CITY OF NORTHAMPTON, MA \ DRIVEWAY PERMIT YYb Date: March 29, 2004 FEE: $25.00 CHECK #: 884 THE BOARD OF PUBLIC WORKS The undersigned respectfully petitions your honorable body for: Permission to install a driveway at 15 Ice Pond Drive Lot #2 Fifteen (15) foot maximum width at the street line. Gutter drainage not to be disturbed. All drainage shall be directed off the driveway surface to adjacent land and not on the existing roadway. Driveway surface to be paved as soon as possible if the grade of the proposed driveway exceeds 3 % or more. Homeowners will be held responsible for any cost to the City of Northampton in the event of a washout of this driveway. Jim Powers 109 Glendale Road Florence, MA 01061 Telephone #: 413 -584 -4204 Proposed Location Inspected By: Gravel Base Grade ( Inspected By: Final Approval THE BOARD OF PUBLIC WORKS voted that petition be granted. George Andrikidis Director of Public Works ; U 0 -- ;:e. - E•:"T- -f rz• . - - .: • O SL-C ttIP1- cf Norfliquipton .m.,sacht,„rn. -6505strr - DEPARTMENT OF BUILDIRC INSPECTIONS = • SPGC TOP 212 /vfain Sired. unicipal Building 17: Nort.httliptoli, Mns..s. 01 OGO Square Footage Amount • Basement' - $ .15 .Ist Floor @ q . 5-C 2n6 Floor @ $ q 779 30 . 1/2 Floors, Attic. Garage $ _33 L ida • Deck, Porches $ 6 1 TOTAL • = 11( • • • • : • . • . . . , • MAR 18 2004 3:S7PM AMERICAN HOME CONSTRUCTIO 413 - 323 -5583 p.4 100 -1313 0.5 1 0.5 0.5 1.0 - -- -NOTES TO FIELD (BAIding Department Use Only MAR 18 2004 3:56PM AMERICAN HOME CONSTRUCTIO 413 -323 -5583 p. • be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R- values, glazing U- values, and heating equipment efficiency must be clearly marked on the building plans I or specifications. I DUCT INSULATION: E 1 1 Ducts shall be insulated per Table J4.4.7.1. I DUCT CONSTRUCTION: E 3 1 All accessible joints, seams, and connections of supply and return ductwork located outside conditioned space, including stud bays or I joist cavities /spaces used to transport air, shall be sealed using mastic and fibrous backing tape installed according tc the manufacturer's installation instructions. Mesh tape may be omitted where gaps are less than 1/8 inch. Duct tape is not I permitted. The HVAC system must provide a means for balancing 1 air and water systems. TEMPERATURE CONTROLS: E 3 1 Thermostats are required for each separate HVAC system. A manual I or automatic moans to partially restrict or shut off the heating and /or cooling input to each zone or floor shall be provided. HVAC EQUIPMENT SIZING: [ 3 1 Rated output capacity of the heating cooling system is 1 not greater than 125: of the design load as specified I in Sections 780C1"R 1310 and J4.4. E 1 1 SWIMMING POOLS: I All heated swimming pools must have an or /off heater switch and require a cover unless over 20% of the heating energy is from non - depletable sources. Pool pumps require a time clock. E 0 f HVAC PIPING INSULATION: I HVAC piping conveying fluids above 120 F or chilled fluids below 55 F must be insulated to the following levels (in.): PIPE SIZES (in.) I HEATING SYSTEMS: TEMP (F) 2" RUNOUTS 0 -1" 1.25 -2" 2.5 -4" I Low pressure /temp. 201 -250 1.0 1.5 1.5 2.0 Low temperature 120 -200 0.5 1.0 1.0 1.5 Steam condensate any 1.0 1.0 1.5 2.0 COOLING SYSTEMS: Chilled water or 40 -55 0.5 0.5 0.75 1.0 refrigerant below 40 1.0 1.0 1.5 1.5 [ 3 1 CIRCULATING HOT WATER SYSTEMS: 1 Insulate circulating hot water pipes to the following levels (in.): PIPE SIZES (in.) NON - CIRCULATING I CIRCULATING MAINS & RUNOUTS I HEATED WATER TEMP (F): RUNOUTS 0-1" I 0 -1.25" 1.5 -2.0" 2.0 +" 370 -1813 0.5 1 1.0 1.5 2.0 1 140 -160 0.5 1 0.5 1.0 1.5 MAR 18 2004 3 :56PM AMERICAN HOME CONSTRUCTIO 413 - 323 -5583 p,2 MAScheck INSPECTION CHECKLIST Massachusetts Energy Code MAScheck Software Version 2.01 DATE: 3 -18 -2004 81dg.1 Dept.1 Use I CEILINGS: E 7 1 1. R -30 Comments /Location (WALLS: C 7 1 1. Wood Frame, 16" O.C., R -19 Comments /Location I WINDOWS AND GLASS DOORS: C 0 1 1. U- value: 0.49 For windows without labeled U- values, describe features: * Panes Frame Type Thermal Break', C 7 Yes C 1 No I Comments /Location DOORS: C 1 1 1. U- value: 0.37 Comments /Location FLOORS: E D 1 1. Over Unconditioned Space, R -19 Comments /Location HVAC EQUIPMENT: C 1 i 1. Furnace, 89.5 AFUE or higher Make and Model Number C I 1 2. Air Conditioner, 10.0 SEER I AIR LEAKAGE: C 3 I Joints, penetrations, and all other such openings in the building I envelope that are sources of air leakage must be sealed. When installed in the building envelope, recessed lighting fixtures shall meet one of the following requirements: 1. Type IC rated, manufactured with no penetrations between the inside of the recessed fixture and ceiling cavity and sealed or gasketed to prevent air leakage into the unconditioned space. I 2. Type IC rated, in accordance with Standard ASTM E 283, with no more than 2.0 cfm (0.944 L /s) air movement from the the conditioned space to the ceiling cavity. The lighting fixture shall have been tested at 75 PA or 1.57 lbs /ft2 pressure difference and shall be labeled. 1 VAPOR RETARDER: C 3 1 Required on the warm -in- winter side of all non - vented framed I ceilings, walls, and floors. I MATERIALS IDENTIFICATION: 1 3 I Materials and equipment must be identified so that compliance can nassachusetts Energy Code 1 Permit a MAS.check Software Version 2.01 1 I I I I Checked by /Date 1 CITY: Northampton STATE: Massachusetts HDD: b404 CONSTRUCTION TYPE: 1 or 2 Family, Detached HEATING SYSTEM TYPE: Other (N n- Electric Resistance) DATE: 3-18-2004 COMPLIANCE: Required .A = 463 9 vPk Your Hoe = 351 Area or Cavity Cont. Glazing /Door Perimeter R -Value R -Value U -Value UA CEILINGS 993 30.0 0.0 35 WALLS: Wood Frame, 16^ 0.C. 2448 19.0 0.0 147 GLAZING: Windows or Doors 222 0.490 109 DOORS 40 0.370 15 FLOORS: Over Unconditioned Space 955 19.0 0.0 45 HVAC EQUIPMENT: Furnace, 89.5 AFUE HVAC EQUIPMENT: Air Conditioner, 10.0 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the requirements of the Massachusetts Energy Code. The heating load for this building, and the cooling load if appropriate, has been determined using the applicable Standard Design Conditions found in the Code. The HVAC ipment selected to heat or cool the building shall be no greater an 1 ' h- desi•n lo0 as specified in Sections 780CMR 131 and J4 my ; /, :: 1 Builder/Designer 1 � Date 1 `^' - Q y CI_ . LC 3WN, la 01007 MUNICIPAL WATER AVAILABILITY APPLICATION Northampton Water Department 237 Prospect St. Northampton, MA 01060 587 -1098 A Department of Public Works Trench Permit shall be required prior to any construction or connection activity associated with this application. Location: 15 Ice Pond Drive Lot 2 Inquiry Made By: Jim Powers 584 -4204 Date of Inquiry: 03/24/04 Municipal Water Main in Existing service to Front of Location? Yes X No: site? Yes: X No: Size of Water Main: 8" Material: DI Age: 2003 Number of Type of X Single Family Type of X Private Units: 1 Unit(s): Accessory Apart. Ownership: Condo Multi- family Rental Approximate Static Street 65 Flow Test Conducted : Yes: No: X Pressure: If done attach results Size of Service Connection: 1" Comments: The Water Department cannot guarantee adequate water pressure during peak demand times at elevations above 320 feet. The City of Northampton has not accepted responsibility for the maintenance of the water main and service connections as of this date of inquiry. • A corresponding water entrance fee shall be paid prior to making any connection to the municipal water system. • Arrangements of such installation shall be made with the Northampton Water Department with a minimum of 5 working days notification. • ...... work shall con to Northampton Water Department specifications. 1 Arw� G )° C S . -_.. David W. Sparks, Superint ndent of Water cc: Ned Huntley, Asst. City Engineer CITY OF NORTHAMPTON BOARD OF PUBLIC WORKS SANITARY SEWER FORCE MAIN POLICY The purpose of this policy is to establish the guidelines, procedures, specifications and conditions associated with sanitary sewer force mains that will become the responsibility of the Department of Public Works (DPW). The following conditions shall apply: 1. All information associated with the entire force main system shall be submitted by the applicant to the DPW for approval. The information shall include, but not be limited to, technical specifications of every system component, capacity of system, operation of valves, pumps and other controlling mechanisms, installation procedures and detailed testing protocols. 2. If the force main system is part of a proposed subdivision, its installation and inspection shall conform to the City' Subdivision Rules and Regulations in addition to the conditions stated in this policy. In all other cases, its installation and inspection shall conform to applicable Rules and Regulations of the DPW in addition to the conditions of this policy. 3. Force main systems shall be designed so that individual pump chambers shall be located outside the street layout. Curb stops and check valves shall be installed at the property line. 4. No connection to the common force main system shall be allowed unless a "Municipal Sewer Availability" and "Residential or Commercial Building Sewer Application" are submitted and approved by the DPW. Attached to these documents shall be the technical specifications, manufacturer's name, model and rated capacity of the proposed pumping system. 5. Prior to the replacement or upgrade of any .existing pumping system, the information requested in Item 4 above must be submitted to the DPW for approval. 6. Pumping chambers on private property shall be accessible at all times. The DPW has the right to enter said property at any time for the purpose of examining the pumping station for compliance with the regulations stated in this policy. The DPW will not be responsible for damage to any plantings or landscaping placed over or in close proximity to the pumping chamber access. 7. A red light indicating system problems /failure shall be installed outside every structure connected to the force main system. Said light shall be clearly visible from a vehicle traveling on the adjacent roadway. 8. It is the responsibility of every owner of a property/structure that is connected to the common force main to insure that all components of their service line are functioning properly and in accordance with the approved submittals. 9. Any violation to this policy may cause the service line of the structure in question to be shut -off at the curb stop. In addition, if the violation causes damages to either the common force main or to adjacent structures connected to the system, the responsible party shall bear the cost of all repairs and claims associated with said violation. 10. The DPW will become responsible only for the components of a sanitary force main system located within the layout of a City accepted street. Acceptance of a street can only be approved by the Northampton City Council. Adopted by the Board of Public Works on May 14, 2003. C:\ Policies \SanitaryForceMainsApril2003 MUNICIPAL SEWER AVAILABILITY APPLICATION Northampton Streets Department 7 c_ 125 Locust Street � Northampton, MA 01060 587 -1570 ' :" - 6 :1CO4 A Department of Public Works Trench Permit shall be require prior to any construction or connection activity associated with this application. Location: 15 Ice Pond Drive Lot 2 Inquiry Made By: Jim Powers 413 - 584 -4204 Date of Inquiry: 03/24/04 Municipal Sewer Main in Front of Location: Yes X No Municipal Storm Drain Available: Yes No X Size of Sewer Main: 8" Material: P.V.C. Age: New in 2003 Depth of Sewer Main: 8' Size of Service Connection: 6" PVC Confluents: . The City of Northampton has not accepted responsibility for the maintenance of the sewer main and service connections as of this date of inquiry. A corresponding "sewer entrance fee" shall be paid prior to making any connection to the municipal sewer system. Arrangements of such installation shall be made with the Northampton Streets Department with a minimum of 5 working days notification. All work shall conform to Northampton Streets Department specifications. l(rJ.4%.43r S torm Drain Concurrence -T 7) 1-2-01 Joseph Thomas, Superintendent Douglas McDonald, Enviromental Planner Streets Department Engineering Department cc: Ned Huntley, City Engineer Anthony Patillo, Building Inspector 9 _11try r p • - � �� (if12 of �rrt:f ' toil i * _M=- �, '1 _ A 2 t� ..q E �tasartrhntrl(e' � DEPARTMENT OP nuiLorNc INSPECTIONS di : \tt: -, cz> 212 Main Street ' Municipal Building Northampton, Hass. 01060 IMO s'' WOR14;R.S COMPENSATION MSITRANCL AFFIDAVIT (li ccusddpermi tree ) with a principal place of business/residence at: (phone') (str t /city /sta tcizi p) do hereby certify, under the pains and penalties of perjury, :hat ( ) I ain an employer providing the followine worker's compensnon cover for Inv employees NI'or og on this job. ' (Insu-ra c Company-) (Potic: Nu-rabcr) (E: Date) I am a sole proprietor eneral contract() r homeowner (circle one) and have hired tNe contractors listed below who have the following worker's COD DtrlSadon pcticies: 4./A 72 l A.), ,/,....,..-,,,,... . , . ,_ 0 = c1Y -6Y' (Nam of Co :v.r cior) (If iranc.: CoInoasny /PGUCi Nu - 11Cr) (:"xi)lidtior Date) (Name. of CooQZctor) (insura.ncc Company /PoLiev Nuncrr) xpu tion Date) (Name of Contractor) (Insurancz Company/Policy Ni) umb (Expirdon Date) (Name of Contractor) (I.asurance Company/Policy Numb•J) (Expiration Date) . (atL d3 itiocaJ cScct if noa_-a.' to . mciud; infocay.00 pcstaiaiag to .11 ooa�-_cnr) - i C ( ) I am a sole proprietor and have no one working for me. ( ) I am,a home owner performing all the work myself. Nom: piece lx G4fut tfix• M La7 Khp ccoploy petona to der [^.m1e- lirY-r, ec�.:e.,ro r rcpair Rorie on . dwelling of not atom th:n tt=o.. t".1C.3 to which the bornoowucr rnida or co the grouix..i zppurtot rued()'- oat Eersalty ocesdzcd to be cntployca orv't; the .. xkd croon Act (GL1 S2,-a 1(5)) nppls* by a bomwwver kr c licz _- a permit rr_y evidcocc the I cg'1 rtaaic of m c loyo- under die Wor4.ola Compocna ion Ant_ I understand th.d a Dopy of this mremam may bo for -worded to tbo Dop. rimcot of rndst -riel Aro8t ' Offsoo of lrrsir x . for the oovanc vc iGcaioa and th.t f_i11=c to tocurt bovcr ece tnodk1 a.oa.ioo 25A of MQL 152 cin kid to the imposition of criminal pcwhio coo:Using of a floc of up to S 1 .300.00 ariddor isolorboanocat of up to ooc y- r nod civil pmahio is dx form of a Stop Work Order Lod a find o(S 100.00 a dry a1in0 mc. For d prone- -- use only - ` ' P (� Permit Numb ot.A./TrvL__ h ( p — lot — S'grature of LiccnscrlPc rmi UGC tl3 _ .J • SECT ONiB CONSTRUCTION ( SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder : �+ � C. P A. * i V q30 f 3 License Number 0 ��,�l�. 7 -z -cr Address Expiration Date io irt.n c c , rn A x 0042. Signat e Telephone . I 4/4 ‘re _,_g.� Centracto` Not Applicable ❑ Company Name Registration Number Address Expiration Date Telephone 404 P.`W,0,WO „COJ1PENSATION 1NSll,13AN,C AFFIDAVIT (M G:L: c. 152, § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes ❑ No ❑ The current exemption for "homeowners" was extended to include Owner - occupied Dwellings of one (1) or two(2) families and to allow such homeowner to engage an individual for hire who does not possess a license, provided that the owner acts as supervisor. CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner: Person (s) who own a parcel of land on which he /she resides or intends to reside, on which there is, or is intended to be, a one or two family dwelling, attached or detached structures accessory to such use and/ or farm structures. A person who constructs more than one home in a two -year period shall not be considered a homeowner. Such "homeowner" shall submit to the Building Official, on a form acceptable to the Building Official, that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time, during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152 (Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death) of the Massachusetts General Laws Annotated, you may be liable for person(s) you hire to perform work for you under this permit. The undersigned "homeowner" certifies and assumes responsibility for compliance with the State Building Code, City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature SfCTt�O I 1=S ONSORPROPOSEDMOR check.all °a . ATTaTemelimpaggt New House 11 Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors ❑ Accessory Bldg. ❑ Demolition❑ New Signs [ ] Decks [ j Siding [ j Other [ j Brief Description of Proposed Wor': 1.34-t id n e S /151c. F15 home_ Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative 0 Renovating unfinished basement Yes No Plans Attached Roll 0 • Sheet 0 Ala ;: o • , D . 'agition`to ex 5ti igho�as i 'c f it fohMh1:: a. Use of building : One Family L Two Family Other b. Number of rooms in each family unit: 7 Number of Bathrooms 3 c. Is there a garage attached? its d. Proposed Square footage of new construction. Gsd 2 FhuaDimensions Y t ZOAC 26 G 4.4 e. Number of stories? GAS f. Method of heating? ,r'��' AS I �OET a1 if- Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Mascheck Energy Compliance form attached? "if,S h. Type of construction Lock) o d F- i. Is construction within 100 ft. of wetlands? Yes 1/ No. Is construction within 100 yr. floodpiain Yes V Nc j. Depth of basement or cellar floor below finished grade 7 k. Will building conform to the Building and Zoning regulations? Yes No . I. Septic Tank City Sewer Private well City water Supply i'* SECb �INE�UTI]ORIZATION TO BE COMPLETED WHEN OWNfilsiA ONTRAC irAPP LIES FOR BUILDING tAiptirsigiA I, , as Owner of the subject property hereby authorize _ to act or my behalf, in all matters relative to work authorized by this building permit application. Signature of Owner Date I dt c t • . dc5 , as Owner /.Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed nder the pains and penalties of perjury. - Print Name SQ,411 cs - C_ b)wr Signature of Owner /Agent Date Section 4. - ALL INFORMATION MUST BE COMPLETED, or PERMIT CAN BE DENIED DUE TO LACK OF INFORMATION Existing Proposed Required by Zoning This column to be filled in by t E Building Department Lot size i f } G f sa F / 0 , cm Frontage 29 • Setbacks Front 30 r / s Side L: R: L: 2 Q R: /J Rear 70 9 6 Building Height / 7 Bldg. Square Footage % , 9,50. Open Space Footage (Lot area minus bldg & paved 9,17? parking) ` # of Parking Spaces Fill: (volume & Location) A. Has a Special Permit /Variance /Finding ever been issued for /on the site? NO DON'T KNOW YES IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO DON'T KNOW YES IF YES: enter Book Page and /or Document # B. Does the site contain a brook, body of water or wetlands? NO J' DON'T KNOW YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained , Date Issued: C. Do any signs exist on the property? YES NO t- IF YES, describe size, type and location: D. Are here any proposed changes to or additions of signs intended for the property ?YES No V IF - YES, describe size, type and location: • • City of Northampton p t 4 Building Department a y , --T3 e & F : .- 212 Main Street �° - Room 100 9� ,tt -1ta t _ Northampton, MA 01060 . 4 g y ' phone 413. 587 -1240 Fax 413 - 587 -1272 ®� , � s APPLICATION TO CONSTRUCT, ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY; DWELLING l ■ APR — 6 2004 _y SECTION 1 - SITE INFORMATION 3L( � r l' , Th i .t tti�o o . - omplete . offie : 1.1 Prope rty dress: -, xwit; °�- j /' kr�; � f s Map ® it � . . Zone Overla Dast £ a r-, ,, Of rr . Cc's f r g Elln St�District s.. . , B` istrict ., .:t,� ' - �� • SECTION 2 PROPERTY OWNERSHIP/AUTHORIZED -AGENT 2.1 Owner of Record: W ,I M C., .c C. { C it.,.. ? O q 5 r' » 1 C7 ci i �... 1 2 0„ C i O i' C ri c Name (Print) Current Mailu Address: C °c , J A 4, _ Telephone ignature 2.2 Authorized Agent: Gm e,s L. PoL.�es _S 1 0 d - v\, ^a . t 4 ; -' ^; Name (Print) Current Mailing Address: 9 ✓ ° , - - 3 f �t. , ^61_4_ �J l 2. Signature Telephone SECTJON.3- ESTIMATED CONSTRUCTION 'COSTS Item Estimated Cost (Dollars) to be Official Use!Only completed by permit applicant 1. Building (a) Building Permit Fee 1 2. Electrical (b) Estimated Total Cost of _______%_a00 Construction from (6) 3. Plumbing Building Permit Fee l 01 0 1 4. Mechanical (HVAC) � ! 000 5. Fire Protection 6. Total = (1 + 2 + 3 + 4 + 5) 1 3 , �CiCe Check Number j ( j, o�J g, 1 This Section For Official Use Only Building`Permit.Number: ! //`(1 Date , Building, Commissioner /Inspector of Buildings Date • • File # BP- 2004 -0965 APPLICANT /CONTACT PERSON JAMES POWERS ADDRESS/PHONE 109 GLENDALE RD FLORENCE (413) 584 -4204 PROPERTY LOCATION 15 ICE POND DRIVE . '- MAP 37 PARCEL 092 001 ZONE SR THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out � 1/ yS Fee Paid JOO ,3. T Construction: CONSTRUCT SFH /ATT GARAGE/PORCH New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/ Statement or License 043041 � pa", 3 sets of Plans / Plot Plan ��E1! ��� � 44.0 THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INF PRESENTED: Approved Additional permits required (see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND /OR Special Permit With Site Plan Major Project: Site Plan AND /OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received & Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Stre Commission „<Z. '-' /': 7 ;.-,/r 7/ ' 7-- 6 - ' '' LeCi c Signature of Building Official D. e Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning & Development for more information. �� qt. `a (iizt rd >�rtli &mpten )L . ,0 �/, 4 . 3 1118'35Ril `t � �`., _ 12 `� DEPARTMENT OF BUILDING INSPECTIONS ==: - — INSPECTOR 212 Main Street • Municipal.Building i �� Northampton, MA 01060 CERTIFICATE of OCCUPANCY and USE This is to certify that permission is hereby granted under 780 CMR, sixth edition of the Massachusetts State Building Code, allowing the occupancy or use of the premises or structure or part thereof located at 15 Ice Pond Drive - Lot #2 as shown on the Assessors Page# 37 , Lot# 9 , Zone SR in the City of Northampton, as herein specified: CONSTRUCTION TYPE(780CMR 6) 5B USE GROUP CLASSIFICATION (780 CMR 3 - R4 OCCUPANT LOAD PER FLOOR (780 CMR Table 1008.1.2 40 PSF LIVE LOAD PER FLOOR (780 CMR Table 1606.1) 40 PSF Under the following limitations, special stipulations, and /or conditions of the permits: Specia Permi Issued this 15th day of October , 20 04 Certificate of Occupancy and Use # BP - 0965 Authorized D ra tment P rsonnel J Electric a4-A- -Q_, • LO g � Elevator Fire 5 _ Plumbing <2, f 'j,.�,+.*00 J i / �i J Building ,I ,, , ./' . _, _ � �.. j Gas � /�� •� � v Building Commissioner ��c This certificate shall be posted by the owner, in a permanent manner and in a visible location, on all floors designated as use group H, S, M, F, or B, and in every room where practicable of use group A, I, R -1, or R -2 per requirement of 780 CMR section 120.5 Posting Structures. ( • , 1 - ' f , t i l l-2W 7 hal .16 1 Ilk, 1 , ,-,-,./q . 9 1 I 4 : 'T .47 1 -4 ) %.:. i I of ,:-4,12. =0,--. ■ 7.44g t 5 , , i , ,..., - :;:,,,,, ( , \ i .... -..cx-,0 frw° 15 ICEPOND DRIVE - LOT"` BP- f' -096 5 GIS # ' COMMONWEALTH OF MASSACHU,TTS Map:Block: 37 - 092 CITY 41F° NORTHAMPTON ;` Lot: -001 i . PERSONS CONTRACTING WITq UNREGISTERED CONTRACTORS 4.w Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (!IGL c.142A) Category: BUILT II \ G 1 E ry . g�' , Permit # BP- 2004 -0965 Proj # JS- 2004 -1437 Est. Cost: $132000.00 Fee: $1009.45 PERMISSION IS HEREBY GRANTED TO: `7 Const. Class: 5B Contractor: License: Use Group: R4 JAMES POWERS 043041 > Lot Size(sq. ft.): Owner: JAMES POWERS I zoning: SR Applicant: JAMES POWERS AT: 15 ICE POND DRIVE - LOT 2 Applicant Address: Phone: Insurance: t 109 GLENDALE RD, (413) 584 -4204 FLORENCEMA01062 ISSUED ON :4/26/04 0 :00 :00 f TO PERFORM THE FOLLOWING WORK :CONSTRUCT SFH /ATT GARAGE /PORCH 1 POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service . 0 /t' '/4 Meter: �' ,� ,� i, J Footings: l ( u A' Rough:7'02 ,/ Rough: °7/ , A y n .House # Foundation: [ - t Driveway Final: hi OL.�'S' O AC 7 Vq, Q 1( Final: �j - ,t ( Final: 1;04 ki f- } t, t r / Rough Frame: p k 7 • of 6o- d 1 4 '�:.4 Gas: Fi A gg i rrn t Fireplace /Chimney: Rough: fi) -( - 6 a Oil: Insulation:0 Pt 5)-3, .,a Final: /0 -1.3 _e yar. moke: Finale /62 / / y° .....d&jo i THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULA NS. Certificate of Occupancy Signature: FeeTvpe: Receipt No: Date Paid: Check No: Amount: Building 4/26/04 0:00:00 903 $1009.45 . - 212 Main Street, Phone (413) 5!. 1241, Fax: (413) 587 -1272 ' Dui:ding Commissioner - _ <'_?:,_lo:;y Patill3 1 A iµ3