d. Landing at each door 36" out and the width of the door minimum 36 ", maximum step 7 %" from
the top of the threshold and only in- swinging doors. 780 CMR R311.3
13. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9 ",
maximum riser 8 % ", maximum overall variance for the run is 3/8 ", 4" sphere rule on risers, 4 3/8" on
balustrade, 6" in the triangle. Graspable rail 1 %" minimum and 2" maximum rail, height minimum 34"
maximum 38 ", required for 4 or more risers. Landing to landing constitutes a new run. Minimum 6'8"
ceiling height from nosing. 780 CMR R311.7.
14. Guards 36" minimum height above walking surface, a bench is a walking surface, required for more than
30" above floor or grade within 36 ", 4" sphere rule. 780 CMR R312.1.
15. Educate the plumber and electrician about maximum notch and hole sizes, and placement. 780 CMR
R502.8 and R602.6. In bearing studs holes not larger than 40% of a stud no closer than 5/8 to the edge,
In interior non - bearing studs holes not larger than 60% of a stud no closer than 5/8 to the edge, in
bearing walls if more than 50% of a plate is cut or notched a 1 1/2" 16ga. strap must extend a minimum of
6" past the cut both directions and be nailed with 8 -10d per side, or holes in joist are a maximum 1/3
the depth not closer than 2" from the top or bottom. Notches are different.
16. Fire and draft stopping shall be completed before rough inspection. 780 CMR R302.
17. Ignition barriers in place before final. 780 CMR R316.
18. Energy aspects shall comply with the stretch energy code. 780 CMR Appendix 115AA and 2009 IECC.
a. An initial HERS evaluation is required including insulation levels anticipated.
b. A final HERS evaluation confirming code requirements have been met including duct testing.
c. Energy information including mechanical equipment posted on the electric panel.
d. Remodeling and Additions can be completed in accordance with IECC 2009 with Energy Star
Building Option Package.
19. Vapor retarders. Although these are still in the code there are exceptions, one must understand that
there is a difference between a vapor retarder or barrier and an air barrier. An air barrier is intended to
stop air flow (convection) a vapor retarder or barrier is intended to stop molecular moisture transfer
(diffusion). A vapor retarder or barrier is effective even if there are some holes or gaps, however an air
barrier has to be absolute and complete. If air can leak through an electrical device or through a crack it
follows the path of least resistance and carries 99% of the moisture in a structure. This is evident every
time one exposes fiberglass insulation and finds black insulation, which is dirt filter out of the air moving
through the insulation. 780 CMR R601.2 for vapor retarders and Table N1102.4.2 for air sealing
requirements.
20. Unvented attic assemblies. Hot roofs are allowed, but have specific requirements 780 CMR R806.4.
21. Deck ledgers and post must be appropriately attached, bolts or lags. 780 CMR R502.2.2.1 Note: ThruLoks
are engineered for post attachment supporting a railing.
22. Smoke and CO detectors as required. 780 CMR R314 and R315.
23. Closets beneath stair which have doors must be drywalled with %'. 780 CMR R302.7
Relevant items must be submitted to the building department for approvals before inspections and or CO can be
signed. Other items are intended to avoid costly issues at inspections.
Feel free to call if you have any questions. My telephone number is 587 -1240 and office hours are Monday
through Friday, 8:30 am to 4:30 pm, excepting we close for walk -ins at 12:00 noon on Wednesdays. My email
address is: cmiller
Thank you for your cooperation on • - - tt-rs. Chuck Miller - City of Northampton - Assistant Commissioner
and Zoning Enforcement
City of Northampton
Massachusetts _ �/
# ,
DEPARTMENT OF BUILDING INSPECTIONS
' r 212 Main Street • Municipal Building
Northampton, MA 01060 z
INSPECTOR
Richard Ahlstrom
215 Madison Avenue
Holyoke, MA 01040
December 13, 2011
Subject Location: 15 Washington Avenue
Map Block: 31A - 178
Mr. Ahlstrom,
These are some items that will require attention:
1. Closets with doors under stairways must be drywalled.
2. Minimum tread for winders is 3" and 10" at 12" in.
3. Windows 72" AFG within 24" of FF fall under 4" sphere rule
As of August 4th 2011 the 8 Addition MA code is the 2009 IRC with MA amendments.
In the following are some generic requirements which seem to be problematic.
This is not a substitute for purchasing and reading the MA codes.
1. Structures shall conform to 780 CMR 8 addition 1 and 2 family building codes with MA amendments.
2. Grading plan for structures being constructed required. 780 CMR R401.3 for drainage requirements.
3. Ceiling joist are intended to prevent spread, once raised above the wall plate they become rafters ties
and may require up sizing of rafters and increased nailing for example with a 4" slope 8 -16nd common
are required at each connection. 780 CMR R802.3.1.
4. Steel straps over the ridge or 1x4 minimum collar ties are required 4' OC in the upper 1 / 3rd 780 CMR
R802.3.1
5. Ridge boards must be the full depth of the cut. 780 CMR R802.3.
6. A complete window and header schedule is required. 780 CMR Table R502.5 for header sizing and
number of jack studs required.
7. All framing materials which are not code prescriptive must have stamped engineering.
a. LVLs
b. I -joist and or Floor Truss
c. Roof truss
8. A braced wall plan identifying appropriate braced wall areas and braced wall method being used. 780
CMR 602.10.
a. Garage corners and large corner window /door layout may require special solutions.
b. All corners must be appropriately attached to the foundation.
9. Ceiling heights minimum 7' for habitable spaces, 6'8" for bathrooms includes tub /shower area if a
shower head is used, 6'8" for basements, 6'4" at beams /ducts. 780 CMR R305.1. MA amended
10. Hazardous glazing locations, within 24" of a door, or within 60" of a stair, or across from hot tubs, spas,
bathtubs within 60" if not 60" above the walking surface, and other locations. 780 CMR R308.4
11. Windows over 72" above grade with the opening less than 24 above the finished floor shall meet the 4"
sphere rule. 780 CMR R612.2
12. Egress and emergency escape requirements shall be strictly met.
a. Basements, habitable attics, and all sleeping rooms require emergency escape. 780 CMR R310
b. Windows within 44" of floor, DH 3.3 sqft min window size, Casement 20 "x41" exception 5 sqft
at 1 floor. Minimum clear opening 20 "x24" or 24 "x20 ". 780 CMR R310.1.1
c. Two doors remote as possible at the normal level of travel, opening measured from the face of
the slab to the stop with door at 90 degrees, one 32" and one 28" minimum 78" high. 780 CMR
R311.2
The Commonwealth of Massachusetts
Department of Industrial Accidents
Office of Investigations
i "°' f - . '`' 600 Washington Street
a ,
4 . ;
Boston, MA 02111
-, www.mass.gov /dia
Workers' Compensation Insurance Affidavit: Builders /Contractors/Electricians /Plumbers
Applicant Information �] Please Print Legibly
Name (Business /Organization/Individual): I t(\ 1 - 6_ . `Te . t . ` ..„ 1 5eru i CeS
Address: `iO3 \ .....? -c_ •-- - •
City /State /Zip: eta Phone #: 653-1906
Are u an employer? Check t h appropriate box:
Type of project (required):
1. LE I am a employer with 3 4. ❑ I am a general contractor and I
employees (full and/or part- time).* have hired the sub - contractors 6. El New construction
2. ❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling
ship and have no employees These sub - contractors have 8. ❑ Demolition
working for me in any capacity. employees and have workers'
[No workers' comp. insurance comp. insurance.: 9. El Building addition
required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions
3. ❑ I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions
myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs
insurance required.] t c. 152, § 1(4), and we have no
employees. [No workers' 13. ❑ Other
comp. insurance required.]
*Any applicant that checks box #1 must also fill out the section below showing their workers' compensation policy information.
t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such.
tContractors that check this box must attached an additional sheet showing the name of the sub - contractors and state whether or not those entities have
employees. If the sub - contractors have employees, they must provide their workers' comp. policy number.
I am an employer that is providing workers' compensation insurance for my employees. Below is the policy and job site
information.
Insurance Company Name: A, i .4k4 . Idat,,, t I v1 s Co {`n ,
Policy # or Self -ins. Lic. #: 8 SSW -7o 1 7 Q Oj Expiration Date: 1 I, 't 1 6 t 1
Job Site Address: t.E, yAjG..Tk.n.i . Ao...0 City /State /Zip: �r. -.•.4 V.ti..._- ---- _
Attach a copy of the workers' compensatiod policy declaration page (showing the policy number and expiration date).
Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a
fine up to $1,500.00 and/or one -year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine
of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of
Investigations of the DIA for insurance coverage verification.
I do hereby certify under the pains and penalties of perjury that the information provided above is true and correct.
Signature'�� 46.-- i� L f
Date: /
Phone #: J 35 - 1r'l60
Official use only. Do not write in this area, to be completed by city or town official.
City or Town: Permit/License #
Issuing Authority (circle one):
1. Board of Health 2. Building Department 3. City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector
6. Other
Contact Person: Phone #:
ECTION 8 - CONSTRUCTION SERVICES
8.1 Licensed Construction Supervisor: Not Applicable ❑
Name e • of License Holder: I�\G V�G4 � � CS --- 7S
2 LL I License Number
4 J O� /fit a" !!�]. t,10
Address Expiration Date
Signature Telephone
D. Registered Home Improvement Contractor: Not Applicable ❑
l ✓1 t v�o� �nrw�. -. C V f, C, T 1 1 'jam
Company Name `` Registration Number
10 F.a t 1
vv AAn/' - 51' - Z (Z t ►7r
Address Expiration Date
� \tAAA4tAl& t MA � 0 Telephone
-.% lg06
SECTION 10- WORKERS' COMPENSATION INSURANCE AFFIDAVIT (M.G.L. c. 152, § 25C(6))
Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result
in the denial of the issuance of the building permit.
Signed Affidavit Attached Yes '6a No ❑
11. - Home Owner Exemption
The current exemption for "homeowners" was extended to include Owner occupied Dwellings of one (1) or two(2) families
and to allow such homeowner to engage an individual for hire who does not possess a license, provided that the owner acts
as supervisor. CMR 780, Sixth Edition Section 108.3.5.1.
Definition of Homeowner: Person (s) who own a parcel of land on which he /she resides or intends to reside, on which there
is, or is intended to be, a one or two family dwelling, attached or detached structures accessory to such use and/ or farm
structures. A person who constructs more than one home in a two - year period shall not be considered a homeowner.
Such "homeowner" shall submit to the Building Official, on a form acceptable to the Building Official, that he /she shall be
• responsible for all such work performed under the building permit.
As acting Construction Supervisor your presence on the job site will be required from time to time, during and upon
completion of the work for which this permit is issued.
Also be advised that with reference to Chapter 152 (Workers' Compensation) and Chapter 153 (Liability of Employers to
Employees for injuries not resulting in Death) of the Massachusetts General Laws Annotated, you may be liable for person(s)
you hire to perform work for you under this permit.
The undersigned "homeowner" certifies and assumes responsibility for compliance with the State Building Code, City of
Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated.
Homeowner Signature
SECTION 5- DESCRIPTION OF PROPOSED WORK (check all applicable)
New House ❑ Addition ❑ Replacement Wj Bows Alteration(s) Roofing n
Or Doors
Accessory Bldg. ❑ Demolition ❑ New Signs [D] Decks [p Siding [D] Other [D]
Brief Description of Propose
Work: ' e✓A0 \r a. r 7V S4-1 vl 1 bar ✓t .jf t,.dh t 0 — t rIc4.^ r1 4.^ (I 'SCV e,1 re plAczwtro w'� �N oO t ✓U a S.
Alteration of existing bedroom Yes X No Adding new bedroom Yes / ` No 1
Attached Narrative Renovating unfinished basement Yes No
Plans Attached Roll CS
5a. If New house and or addition to existing housing, complete the following:
i a. Use of building : One Family Two Family Other
5. Number of rooms in each family unit: Number of Bathrooms
c. Is there a garage attached?
1 :. Proposed Square footage of new construction. Dimensions
e. Number of stories?
f. Method of heating? Fireplaces or Woodstoves Number of each
g. Energy Conservation Compliance. Masscheck Energy Compliance form attached?
h. Type of construction
i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No
j, Depth of basement or cellar floor below finished grade
k. Will building conform to the Building and Zoning regulations? Yes No .
I. Septic Tank City Sewer Private well City water Supply
SECTION 7a - OWNER AUTHORIZATION - TO BE COMPLETED WHEN
OWNERS AG NT OR CONTRA TOR APPLIES FOR BUILDING PERMIT
1
1, / —X.... t1L4A., a flit e S . Q ' , , as Owner of the subject
property �� 4
hereby - horiz• "n/l ..... f !`�'�`� i'7 �6� "'�2 �rr�(B! -�
to act on �' . -half, in all ma to - relative to w s7 authorized by this building permit application.
L l_z � - 10
Signa re of 0 ner Al Date
1, ..'R1 es. 1--- Nt,‘ '•\n - cr-w-, , as Owne Authorized '
Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of m w edge
and belief.
Signed under the pains and penalties of perjury.
G1'1. ov--S ACL% l S ,...„.
.. Print Name
Signature of Owner/ ent Date
L
a
Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information
Existing Proposed Required by Zoning
This column to be filled in by
Building Department
Lot Size
Frontage
Setbacks Front
• Side L: R: L: R:
Rear
Building Height
Bldg. Square Footage %
Open Space Footage
(Lot area minus bldg & paved
parking)
# of Parking Spaces
Fill:
(volume & Location)
A. Has a Special Permit /Variance /Finding ever been issued for /on the site?
NO 0 DONT KNOW 0 YES 0
IF YES, date issued:
IF YES: Was the permit recorded at the Registry of Deeds?
NO 0 DONT KNOW 0 YES 0
IF YES: enter Book Page and /or Document #
B. Does the site contain a brook, body of water or wetlands? NO 0 DONT KNOW 0 YES 0
IF YES, has a permit been or need to be obtained from the Conservation Commission?
Needs to be obtained 0 Obtained , Date Issued:
C. Do any signs exist on the property? YES 0 NO 0
IF YES, describe size, type and location:
D. Are there any proposed changes to or additions of signs intended for the property ? YES 0 NO 0
IF YES, describe size, type and location:
E. Will the construction activity disturb (clearing, grading, excavation, or filling) over 1 acre or is it part of a common plan
that will disturb over 1 acre? YES 0 NO 0
IF YES, then a Northampton Storm Water Management Permit from the DPW is required.
Department use only
City of Northampton Status of Permit:
Building Department Curb Cut/Driveway Permit
212 Main Street Sewer /Septic Availability
Room 100 WaterlWel ay. • � _ a
Northampton, MA 01060 Two Sets o Struct ` . . - - - J.
phone 413 - 587 -1240 Fax 413 - 587 -1272 Plot/Site Pl. ns
Other Speci ■ .. — 5 N` t
APPLICATION TO CONSTRUCT, ALTER, REPAIR, RENOVATE OR DEMOLISH •l OR TWO FAMILY DWE LINt
pEpr OF BUiU)Ih'G iN
. ,LM*
�,�ppTHAt�PTCN, MFa 01060
SECTION 1 - SITE INFORMATION
1.1 Property Address: This section to be completed by office
e5 w 4,,s -- ‘ 4-v-. , Map Lot Unit
WO A`. / A Zone Overlay District
Elm St District CB District
SECTION 2 - PROPERTY OWNERSHIP /AUTHORIZED AGENT
2.1 Owner of Record:
�-�-es 44 / -5 bt/A 5.4' 7 z Air.
name Current,Nlai r Addre g II _ D t (co 1
.ME , • _ A �4. J Telephone
2 A ill • ized Agent:
GLzA,-- 4-4 /S74--v -, 2/6 41 . "Ive if /-
Name (Print) Current Mailing Address:
.4" Z.-.--------- 1 -1 (3 - . k
Signature Telephone
SECTION 3 - ESTIMATED CONSTRUCTION COSTS
Item Estimated Cost (Dollars) to be Official Use Only
completed by permit applicant
1. Building b D (a) Building Permit Fee
r
2. Electrical (b) (b) Estimated Total Cost of
l a V C O Construction from (6)
3. Plumbing / Building Permit Fee
y. Mechanical (HVAC)
5. Fire Protection /,/
6. Total = (1 + 2 + 3 + 4 + 5) 1 1' d t 6 0 0 , ctc_ Check Number dr0 'r b
This Section For Official Use Only
Building Permit Number: Date
g Issued:
i Signature:
Building Commissioner /Inspector of Buildings Date
File # BP- 2012 -0545
APPLICANT /CONTACT PERSON RICHARD AHLSTROM
ADDRESS/PHONE 903 HAMPDEN ST HOLYOKE (413) 533 -9900 ()
PROPERTY LOCATION 15 WASHINGTON AVE
MAP 31A PARCEL 178 001 ZONE URB(100)/
THIS SECTION FOR OFFICIAL USE ONLY:
PERMIT APPLICATION CHECKLIST
ENCLOSED REQUIRED DATE
ZONING FORM FILLED OUT
Fee Paid
Building Permit Filled out �/ it
Fee Paid F"►
Typeof Construction: RENOVATE BARN STUDIO & INSTALL REPLACEMENT WINDOWS
New Construction
Non Structural interior renovations
Addition to Existing
Accessory Structure
Building Plans Included:
Owner/ Statement or License 073454
3 sets of Plans / Plot Plan
THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON
INFO ION PRESENTED:
Approved Additional permits required (see below)
PLANNING BOARD PERMIT REQUIRED UNDER:§
Intermediate Project: Site Plan AND /OR Special Permit With Site Plan
Major Project: Site Plan AND /OR Special Permit With Site Plan
ZONING BOARD PERMIT REQUIRED UNDER: §
Finding Special Permit Variance*
Received & Recorded at Registry of Deeds Proof Enclosed
Other Permits Required:
Curb Cut from DPW Water Availability Sewer Availability
Septic Approval Board of Health Well Water Potability Board of Health
Permit from Conservation Commission Permit from CB Architecture Committee
Permit from Elm Street Commission _ Permit DPW Storm Water Management
I emolition D - ay
ignature of Building 0 cial Date
Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning
requirements and obtain all required permits from Board of Health, Conservation Commission, Department
of public works and other applicable permit granting authorities.
* Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of
Planning & Development for more information.
15 WASHINGTON AVE BP- 2012 -0545
GIS #: COMMONWEALTH OF MASSACHUSETTS
Map:Block: 31A - 178 CITY OF NORTHAMPTON
Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
Category: renovation BUILDING PERMIT
Permit # BP- 2012 -0545
Project # JS- 2012 - 000914
Est. Cost: $40000.00
Fee: $240.00 PERMISSION IS HEREBY GRANTED TO:
Const. Class: Contractor: License:
Use Group: RICHARD AHLSTROM 073454
Lot Size(sq. ft.): 11325.60 Owner: HAUG JAMES & ALEXANDRA KENNEDY
Zoning: URB(100)/ Applicant: RICHARD AHLSTROM
AT: 15 WASHINGTON AVE
Applicant Address: Phone: Insurance:
903 HAMPDEN ST (413) 533 -9900 () Workers Compensation
HOLYOKEMA01040 ISSUED ON:12/13/2011 0:00:00
TO PERFORM THE FOLLOWING WORK: RENOVATE BARN STUDIO & INSTALL
REPLACEMENT WINDOWS
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter:
Footings:
Rough: Rough: House # Foundation:
Driveway Final:
Final: Final:
Rough Frame:
Gas: Fire Department Fireplace /Chimney:
Rough: Oil: Insulation:
Final: Smoke: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Certificate of Occupancy Signature:
FeeType: Date Paid: Amount:
Building 12/13/2011 0:00:00 $240.00
212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272