44-052 (2) Now . . . . ........ �N b. Two doors remote as possible at the normal level of travel, opening measured from the fa o f to the stop with door at 90 degrees, one 32" and one 28" minimum 78" high. 780 CMR R311.2 the slab c. Landing at each door 36" out and the width of the door minimum 36 ", maximum step 7 /" from of the threshold and only in- swinging doors. 780 CMR R311.3 the top 13. Stairs have critical standards, make sure you know the floor finishes when planning. Minimu m tread 9 " maximum riser 8 %" / , maximum overall variance for the run is 3/8 ", 4" sphere rule on risers, 4 3/ o , n balustrade, 6" in the triangle. Graspable rail 1 %" minimum and 2" maximum rail, height minim 38 ", required for 4 or more risers. Landing to landing constitutes a new run. Minimum 6'8" ceiling ei maximum nosing. 780 CMR R311.7. 14. Guards 36" minimum height above walking surface, a bench is a walking surface g height from above floor or grade within 36 ", 4" sphere rule. See 780 CMR R312.1. required for more than 30" 15. Educate the plumber and electrician about maximum notch and hole sizes, and placement. See 7 and R602.6. in bearing studs holes not larger than 40% of a stud no closer than 5/8 to the edge, In inte rior bearing studs holes not larger than 60% of a stud no closer than 5/8 to the edge, in bearing wall 80 CMR R502.8 50% of a plate is cut or notched a 1 % "past the cut both d " 16ga. strap must extend a minimum of 6 g irections error non s if more than and be nailed with 8 -10d per side, or holes in joist are a maximum 1/3 the depth not closer than 2" from or bottom. Notches are different. om the top 16. Fire and draft stopping shall be completed before rough inspection. See 780 CMR R302. 17. Ignition barriers in place before final. See 780 CMR R316. 18. Energy aspects shall comply with the stretch energy code. See 780 CMR Appendix 115AA and 200 a. An initial HERS evaluation is required including insulation levels anticipated. 9 IECC. b. A final HERS evaluation confirming code requirements have been met including duct testin . c. Energy information including mechanical equipment posted on the electric panel. g d. Remodeling and Additions can be completed in accordance with IECC 2009 with Energy St Option Package. Star Building 19. Vapor retarders. Although these are still in the code there are exceptions, one must understand th at there is a difference between a vapor retarder or barrier and an air barrier. An air barrier is intended to stop air (convection) a vapor retarder or barrier is intended to stop molecular moisture transfer (diffusion flow retarder or barrier is effective even if there are some holes or gaps, however an air barrier has to be absolu t and complete. If air can leak through an electrical device or through a crack i � A vapor and carries 99% of the moisture in a structure. This is evident every time one expo es fiberrgl h of least resistance pat finds black insulation, which is dirt filter out of the air moving through the insulation. See 780 CMR R601.2 and vapor retarders and Table N1102.4.2 for air sealing requirements. 1.2 for 20. Unvented attic assemblies. Hot roofs are allowed, but have specific requirements See 780 CMR R806.4 21. Deck ledgers and post must be appropriately attached, bolts or lags. See 780 CMR R502.2.2.1 Note: Thr engineered for post attachment supporting a railing. uloks are 22. Smoke and CO detectors as required. See 780 CMR R314 and R315. Relevant items must be submitted to the building department for approvals before inspections and or CO ca Other items are intended to avoid costly issues at inspections. n be signed. Feel free to call if you have any questions. My telephone number is 587 -1240 and office hours are Monda thr Friday, 8:30 am to 4:30 pm, excepting we close for walk -ins at 12:00 noon on Wednesdays. y ough Thank o eratio n these matters. Chuck Miller - City of Northampton Assistant Commissioner and Zoning Enforcement cmiller northam ton ma.aov City of Northampton Massachusetts DEPARTIMNT OF BUILDING INSPECTIONS x: 212 Main Street • Municipal Building Northampton, MA 01060� INSPECTOR Roy Omasta 21 North Street Hatfield, MA 01038 October 25, 2011 Mr. Omasta Subject Location: 1140 Florence Road (addition and two garages) Map Block: 44 - 052 Your electronic plans dated 10 -19 -11 have been approved as noted. 1. Smokes and Cos per code and fire department. 2. Energy criteria must meet the stretch code requirements. 3. Engineering data for all non prescriptive materials. 4. Fire separation required between units. 5. Separate and independent electric panels accessible to the unit. 6. Braced wall details must be followed without exception. As of August 4 2011 the 8 Addition MA code is the 2009 IRC with MA amendments. In the following are some generic requirements which seem to be problematic. This is not a substitute for purchasing and reading the MA codes. 1. Structures shall conform to 780 CMR 8 addition 1 and 2 family building codes with MA amendments. 2. Grading plan for structures being constructed required. See 780 CMR R401.3 for drainage requirements. 3. Where ceiling joist are not directly connected to the rafters, rafter ties are required and must be in the bottom 1/3` . See 780 CMR R802.3.1. Minimum 2x416" OC nailed per 780 CMR Table R802.5.1(9) 4" slope 8 -16nd common at each connection. 4. Steel straps over the ridge or 1x4 minimum collar ties are required 4' OC in the upper 1/3` CMR R802.3.1 5. Ridge boards must be the full depth of the cut 780 CMR R802.3. 6. A complete window and header schedule is required. See 780 CMR Table R502.5 for header sizing and number of jack studs required. 7. All framing materials which are not code prescriptive must have stamped engineering. a. LVIs b. [-joist and or Floor Truss c. Roof truss 8. A braced wall plan identifying appropriate braced wall areas and braced wall method being used. See 780 CMR 602.10. a. Garage corners and large corner window /door layout may require special solutions. b. All corners must be appropriately attached to the foundation. 9. Ceiling heights minimum 7' for habitable spaces, 6'8" for bathrooms includes tub /shower area if a shower head is used, 6'8" for basement without habitable space, 6'4" at beams /ducts. 780 CMR R305.1. 10. Hazardous glazing locations, within 24" of a door, or within 60" of a stair, or across from hot tubs, spas, bathtubs within 60" if not 60" above the walking surface, and other locations. See 780 CMR R308.4 11. Windows over 72" above grade with the opening less than 24 above the finished floor shall meet the 4" sphere rule. See 780 CMR R612.2 12. Egress and emergency escape requirements shall be strictly met. a. Windows within 44" of floor, DH 3.3 sqft min window size, Casement 20 "x41" exception 5 sqft at 1st floor. Minimum clear opening 20 "x24" or 24 "x20 ". 780 CMR R310.1.1 EaYM M rWr fYe r.w III uP.nSd ........ eti Ww1bn '. I C v o v n Ih r � O-VY tit Iwrr IYWr rill emr SS r► M wll I � Iur/.� b SM Imo' '. 1�1e IS11� X1111 fW W� iW� ti �rww •nom ti f ti n� N W /rM. 4Y✓. bP m r rr.- e.- ,he�rr .ay eon rr..r ey.rp wwP m r r.rr- s�yo-.r .ty A MMNrM wra'L M .J 1A WwW V'r'hMiO uTMO Y rS.IS� b S� W.L L low C b W tlYYr� tlS110 Ifnc1.Y PP •wtl0. Ir rr u Y rah � �N �gbNM� � Pr' Yi1F Isr nrpw N rh Ia' � K I.rFL Iti m rN Sp Iln M }dt IWY Pn` TWe w. IiIO.' rr Pr llO.li TM — i 0%!4T a [-W n Sow pnr N o c Q) 0 CL (D LU 4 cn - Z r O C) is ' i = -- O � -- N C=h > � Q LU fl ui Q) -------- -- C: ------------- w CD CD Charles Miller From: danielgomez@comcast.net Sent: Thursday, October 20, 2011 4:37 PM To: Charles Miller Subject: Re: Revision to drawings for 1140 Florence Road, Powers Residence Renovation Attachments: Revision101911 Garage Plans 32x32.pdf; APA_NWB_Bracing- Method- PFG2[1].pdf Hi Mr. Miller, In answer to your inquire and based on the 2009 IRC 602.10.5 section and the APA wall bracing guidelines , please find below a description of my wall bracing calculations for the front of both of these garage buildings. A) Attached Garage 29'x29' . There are 2 wall brace lines proposed. #1 across the back of the building, and #2 to the front of the building where the Two 10'w x 7' h overhead doors are planned. Wall bracing lines separation of 28'- 6" to be below the 35' allowed for this type of building height considering winds below 110 m /h, per IRC 602.10.1 Regarding specifically to the # 2 front line, there are 3 wall bracing panel segments proposed , one at each end, and one at the center of the wall bracing line. Each segment to be min of 32" wide. Following the Continuous Wood Structural Sheating Panels Method per IRC 602. 10. 5 (See attached pdf detail) . We provide each segment with a min of 32" widht by the 8' -6" of total ceiling height , which next to a 7 ' high door openings mantains their bracing capabilities (below the 85% max height), also allowing to keep continuos 12" header across the entire wall bracing line . These 3 segments added constitute a wall bracing total of 8', which represents 27% of the 29' total of our wall bracing line. This percentaje is above the 20% min required for wall bracing built under these conditions. Table IRC602.10.1 Therefore: 3 x 32" = 96" = 8' (total wall bracing) x 100/29'= 27% > 20% min required. B) Unattached Garage 32'x32' . As the previous building, There are also 2 wall bracing lines, in this case set apart 31' -6 ", still below the 35' max distance allowed between wall bracing lines under similar building conditions. (This building is rotated 90 degrees in relation to the other). The front wall bracing line in this case has 4 wall bracing panel segments ( continuos wood structural sheating method also ) not less than 36 "wide x 8' -6" total ceiling height . One at each end and another two in between the overhead doors. In this particular case, we are proposing to add a single 36'x 80" door at the center of the wall line additional to the two 8'x 7' overhead garage doors at each side. These door openings also are below the 85" max heihht allowed, contributing to maintain the wall bracing capability of each segment and provide the 12" continous header. These 4 segments added account for 13' , which represents 40% of the total 32' wall bracing line, which is above the 20% min under these circunstances per IRC 602.10.5 permited mostly . Therefore: ( 2x 36) +(2x42)= 13' (total wall bracing) x100/32 = 40% > 20% min required. Hoping this description assist to clarify the issue, I'm attaching a revised drawing A.6 adding a floor section plan of the unattached garage front part in order to illustrate our intention. (See F /A6) i F Y I HOME OWNER EXEIWIPTION ACKNOWLEDGEMENT The State of Massachusetts allows the homeowner the right under 780CMR 108.3.4 to act as his/her construction supervisor. The state defines "Homeowner". as, " Person(s) who owns a parcel on which he/she resides or intends to be, a one or two family dwelling, attached or detached structures accessory to 'such use and/or farm structures. A person who constructs more than one home in a two-year period shall not be considered a home owner." The building department for the City of Northampton wants persons) who,,seek to use the home owner exemptron;-ta act" as their own constraz rgn'sagervisor to bo `aware that by doing so you become responsible for compliance with state budding codes and regulations. The inspection process requires, that the.building department be called to inspect work at various stages, which ince lud foundation /footings (before backrdl), sonotube holes (before-your), a rough building-insuection (before work is concealed), insulation inspection (if reauired) and *final building inspection. The boil ding departm re quires the ins b efore the work is concealed, failure to secure these inspections can- result in. Mire 'to obtain a certificate of occunancv until. the work can be `inspected. If the homeowner hires other trades. to perform work (electrical, plumbing & gas)-the homeowner wiff be responsible to make sure that the trades hired secure their proper �ermits in conjunction to the building permit issued, and that they get their required inspections. Failure of the individual trades to secure the permits and inspections as required can DELAY the project until such time as the proper permits and inspections are made I, understand the above .(Home owner /resident's signature requesting exemption) I will call to schedule all required building inspections necessary for the building permit issued to `ine: Date Address of work location The Commonwealth of Massachusetts Department of Industrial Accidents. ' Office of Investigations 600 Mishington Street w Boston, MA 02111 www.massgov/dia -Workers' Compensation Insurance Affidavit: Builders / Contractors /Electricians/PIumb.ers APPUcant Information Please Print Le 'bl Name ( Business /Organiiat on/Individual): F.//��� � ' ; e S (' Address: City /State/Zip: VW Yom K , `o /v g Phone. #: ? _S C6 J6 Are you -an employer?. Check the appropriate'box: . T yP e of P ro ect (r uir ed): 1. ❑ I am a employer with 4.. [J I am a general contractor and I .y 6_ ew co nstruction `— - - - - - - -- employees hill and/or part-time). * have- hired- thc-sub contractors— emp y -( — — - --- - -- 2.. ❑ I am' a sole proprietor or partner- listed on the attached sheet. 7. [ odeling - - - - ° These sub-contractors- �� and have. no - - 8. ❑ Demolition working . for me in any capacity. employees and have workers' 9: Building addition [No workers' comp: insurance tromp. in surance $ Q _ re ecL 5. E] We area corpoiation and its 10.E] -Electrical repairs or additions - 3. El I am a m a ) .• officers hUercised their Plumbi n g r eP arcs or additions homeowner doing all work ave .r 11 . � . myself [No workers' comp. right of exemption per MGL 12.Q.Roof repairs insurance required.) t c. 152, § 1(4) and we have no employees. [No workers'a 13.0 Other comp. insurance regtiired.} _ *Any applicant •that checks box 3{_l_ mu also fill out the section below showing their workers' h information. coraperssati policy . - t Homeowners who submit this affi davit indicating they are doing ail work and then flue outsidecontrrctm must submit a new affidavit indicating such. tContractors that check this box must.attached an additional sheet showing the name of the sub - contractors and state whether or not those entities have employees. 'If the sub—contractors have employees, they must provide their workers' comp. policy number I am an employer that is providing workers' compensation insurance for my employees. Below is the policy and job site information. Insurance Company Policy # orSelf- -ins. Ltc #: S l r + Expiration Date: 7/ Job Site Address: 0 1 � ���= " City /Staw ip C�TIi!t�n 'p!v d/d 6 C� Attach a copy of the workers" compensation policy declaration page (showing the policy number and expiration date). Failure. to secure coverage.as required under Section 25A of MGL C. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or owe -year imprisonment; as well as civil penalties in the form o£ a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investieations of the DIA for insurance coveraee verification. Ida. hereby ceqp under the ' and penalties of perjury that the information provided above is true and correct = - -Si fume: -- - Phone #: Kl3 '-?'f 7 -- S:16 &-4 Official use only. Do not write in this area, lobe completed by city or town officiaL City or Town: Permit/License_ # Issuing Authority (circle one): J. Board of Health 2. Building Department 3. City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector 6. Other r Contact Person: Phone #: SECTION 8 - CONSTRUCTION. SERVICES 8.1 Licensed Construction Supervisor Not Applicable; ❑ Name of License Holder �CD(,� (//t't s */� ' 1, 7 42 License Number Address / Expiration Date Signatur Telephone " Not Applicable ❑ �i�9S� Imo' 460 S . �� -- D, -rrys 7 d /533 Company Name Registration Number ev Address Expiration Date Telephone SIr+CTION 10- 1NQRKERS'. QMPENSATIQN [NSURANCE pFE f3l 1fIT (Ills G L x. 152, §'"51r { &)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the buildingpermit. Signed Affidavit Attached Yes....... No...... ❑ k _ n The current exemption for "homeowners" was extended to include Owner - occupied Dwellings of one (1) or two(2) families and to allow such homeowner to engage an individual for hire who does not possess a license, provided that the owner acts as supervisor. CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner Person (s) who own a parcel of land on which he/she resides or intends to reside, on which there is, or is intended to be, a one or two family dwelling, attached or detached structures accessory to such use and/ or farm structures. A person who constructs more than one home in a two-year period shall not be considered a homeowner Such "homeowner" shall submit to the Building Official, on a form acceptable to the Building Official that he /she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time, during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152 (Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death) of the Massachusetts General Laws Annotated, you may be liable for person(s) you hire to perform work for you under this permit. The undersigned "homeowner" certifies and assumes responsibility for compliance with the State Building Code, City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature SECTION: 5- DESCRIPTION OE PROPOSED WORK (check all aaaltcable) � Y .•w New House ❑ Addition Replacement Windows Alteration(s) Roofing ❑ Or Doors D Accessory Bldg. L_( Demolition ❑ New Signs [0] Decks [Q Siding [0] Other [[] ti scri Brief D Qn o Pro sed Work: es A V4 1 1e t� I '� � �' ° 15�1 t, 1'8 � fit C7 4/!AY` Alteration of existing bedroom Yes No Adding new bedroom Yes l i. , No Attached Narrative Renovating unfinished basement Yes V No Plans Attached Roll - Sheet a. Use of building: One Family Two Family v Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? c d. Proposed Square footage of new construction. Dimensions e. Number of stories? / ,Q f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Ty f construction e i. Is construction within 100 ft. of wetlands? Yes _/No. Is construction within 100 yr. floodplain Yes /No j. Depth of basement or cellar floor below finished grade k. Witfbuilding conform to the Building and oning regulations? I V - Yes NO. I. Septic Tank City Sewer Private well City water Supply SECTION 7a - OWNER AUTHORl7iTION T4 BE COMPLETED WHEN OWNERS AGENT CR CONTRA.CTOR APPLIES FaR BUILT 10I PERMIT as Owner of the subject property hereby authorize to act on be If, in all rs re o it uthorized by this building permit application. ..c E- I — Signat ne, Date d !M/gSr as Owner /Authorized Agent her by declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Print Name Signature o n r /Agent Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomple Information t Existing Proposed Required by birt'irlg W � ', This column to a fill in -+ Building Depa ent « 2{ t Lot Size —�- 0 Frontage Setbacks Front V7__ Side L: RA 10 7 L: R: Sc1 Rear E ght Footage L % Footage - - -% bldg & paved # of Parking Spaces Fill: volume & Location) A. Has a Special Permit /Variance /Finding er been issued for /on the site? NO 0 DONT KNOW YES 0 IF YES, date issued:_ - -� IF YES: Was the permit recorded at the Regi ry of Deeds? NO ® DONT KNO YES 0 IF YES: enter Book Page and /or Document #' B. Does the site contain a brook, body of water or wetlands? NO GY KNOW 0 YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained , Date Issued: C. Do any signs exist on the property? YES ® NO IF YES, describe size, type and location: ___ D. Are there any proposed changes to or. additions -of signs, intended_ for the property? YES 0 NO IF YES, describe size, type and location: E. Will the construction activity disturb (clearing, grading, excavati or filling) over 1 acre or is it part of a common plan that will disturb over 1 acre? YES 0 NO � IF YES, then a Northampton Storm Water Management Permit from the DPW is required. • ' E vEp ity of Northampton uilding Department 212 Main Street SEP 1 2 Room 100 No hampton, MA 01060 � B omu� 1 - 87 -1240 Fax 413- 587 -1272 APPLICATION TO CONSTRUCT, ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION This secLon to be completed by -9 1c e 1.1 Property Address / LN��� Zo�rte� �Oyerlay}rstct s r --4 Etrii SIstrlcC CBt)istr[ct SECTION 2:- PROPERTY OWNERSHI IZED AGENT 2.1 Owner of Record: pq f Name (Print) Current Mailing Address: Telephone J — Signa u 2.2 Aut orized Aoent: Piq G��c�tsfiig c?1 �✓oR S�" f�9t'���l� �rb3 Name ( 'nt) Current Mailing Address: Si aturdl Telephone SECTION 3 ESTIMATED CONS TRUCTIOM'COSTS . _... Item Estimated Cost (Dollars) to be Official Use on #y completed by ermit a pplicant G�iU (a) Building Pemmit Fee 1. Building vj 2. Electrical 1 (� (b). Estimated Total Gost.of Construction from 6 3. Plumbing -7 �(j Building Perntit Fee 4. Mechanical (HVAC) 300 5. Fire Protection er A 6. Total= (1 +2+3+4+5) (�U p U Check Number Tfiis Section For Official Use Onl Date Building Permit Number: Issued: Signature: Building Commissioner /Inspector of Buildings Date l�� File # BP- 2012 -0243 APPLICANT /CONTACT PERSON ROY OMASTA ADDRESS/PHONE 21 North St HATFIELD (413) 247 -5666 PROPERTY LOCATION 1140 FLORENCE RD MAP 44 PARCEL 052 001 ZONE SR(100)/ THIS SECTION FOR OFFICIAL USE ONLY: �� q4 I PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid J Typeof Construction:_ RENOVATE & CONSTRUCT ATT 28 X 29 GARAGE & 32 X 32 DET GARAGE New Construction Non Structural interior renovations Addition to Existing Accessory Structure Buildinp Plans Included: Owner/ Statement or License 006763 3 sets of Plans / Plot Plan - A4" AARII THE FO�LLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INRM � P!ATION PRESENTED: �� Approved Additional permits required (see below) PLANNING BOARD PERMIT REQUIRED UNDER: § Intermediate Project: Site Plan AND /OR Special Permit With Site Plan Major Project: Site Plan AND /OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received & Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management De fit elay ature of Builifm Offic' l Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning & Development for more information. 1140 FLORENCE RD BP -2012 -0243 GIs #: COMMONWEALTH OF MASSACHUSETTS Map:Bloc 44 - 052 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: ADDITION BUILDING PERMIT Permit # BP- 2012 -0243 Project # JS- 2012 - 000377 Est. Cost: $238300.00 Fee: $1430.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: ROY OMASTA 006763 Lot Size(sa. ft.): 165963.60 Owner: SHEEHAN JOHN G Zoning: SR(100)/ Applicant. ROY OMASTA AT. 1140 FLORENCE RD Applicant Address: Phone: Insurance: 21 North St (413) 247 -5666 Workers Compensation HATFIELDMA01038 ISSUED ON :1012512011 0:00:00 TO PERFORM THE FOLLOWING WORK.- RENOVATE & CONSTRUCT ATT 28 X 29 GARAGE & 32 X 32 DET GARAGE POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace /Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Siinature: FeeType: Date Paid: Amount: Building 10/25/20110:00:00 $1430.00 212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272 Louis Hasbrouck — Building Commissioner